cone beam ct for dental and maxillofacial radiology
... against the dangers arising from ionising radiation (Basic Safety Standards Directive) Directive 97/43/Euratom, of 3 June 1997, on health protection of individuals against the dangers of ionising radiation in relation to medical exposure (Medical Exposures Directive) Beyond these sources, the detail ...
... against the dangers arising from ionising radiation (Basic Safety Standards Directive) Directive 97/43/Euratom, of 3 June 1997, on health protection of individuals against the dangers of ionising radiation in relation to medical exposure (Medical Exposures Directive) Beyond these sources, the detail ...
Cone Beam Ct for Dental and Maxillofacial Radiology
... Directive 97/43/Euratom, of 3 June 1997, on health protection of individuals against the dangers of ionising radiation in relation to medical exposure (Medical Exposures Directive) ...
... Directive 97/43/Euratom, of 3 June 1997, on health protection of individuals against the dangers of ionising radiation in relation to medical exposure (Medical Exposures Directive) ...
Lecture 8 - Mammography and tomosynthesis
... The X-ray tube • In mammography, to maximise contrast use the lowest kV possible • Typical compressed breast thickness is 40-50 mm, and rarely greater than 80 mm • Ideal mono-energetic X-ray beam would be 1622 keV • Hence, the use of the full range of the Bremsstrahlung spectrum from a tungsten tar ...
... The X-ray tube • In mammography, to maximise contrast use the lowest kV possible • Typical compressed breast thickness is 40-50 mm, and rarely greater than 80 mm • Ideal mono-energetic X-ray beam would be 1622 keV • Hence, the use of the full range of the Bremsstrahlung spectrum from a tungsten tar ...
Mammography and tomosynthesis
... The X-ray tube • In mammography, to maximise contrast use the lowest kV possible • Typical compressed breast thickness is 40-50 mm, and rarely greater than 80 mm • Ideal mono-energetic X-ray beam would be 1622 keV • Hence, the use of the full range of the Bremsstrahlung spectrum from a tungsten tar ...
... The X-ray tube • In mammography, to maximise contrast use the lowest kV possible • Typical compressed breast thickness is 40-50 mm, and rarely greater than 80 mm • Ideal mono-energetic X-ray beam would be 1622 keV • Hence, the use of the full range of the Bremsstrahlung spectrum from a tungsten tar ...
MICHIGAN DEPARTMENT OF PUBLIC HEALTH RADIATION
... (2) "Exposure" means the quotient of dQ by dm where dQ is the absolute value of the total charge of the ions of 1 sign produced in air when all the electrons (negatrons and positrons) liberated by photons in a volume element of air having mass dm are completely stopped in air. The special unit of ex ...
... (2) "Exposure" means the quotient of dQ by dm where dQ is the absolute value of the total charge of the ions of 1 sign produced in air when all the electrons (negatrons and positrons) liberated by photons in a volume element of air having mass dm are completely stopped in air. The special unit of ex ...
American Association of Physicists in Medicine 40th Annual
... This is my last year to serve in the capacity of Program Committee Chairman, and it has been both an honor and a pleasure to serve the association. I am grateful for the experience. Robert G. Gould, Sc.D. Program Committee Chairman ...
... This is my last year to serve in the capacity of Program Committee Chairman, and it has been both an honor and a pleasure to serve the association. I am grateful for the experience. Robert G. Gould, Sc.D. Program Committee Chairman ...
Calculation, verification and monitoring of patient dose in Diagnostic
... carried out on two virtually identical systems that were installed approximately 5 years apart. Results indicated that patient doses were higher on the new lab despite cardiologist technique appearing to have improved (25.1Gy.cm2 for the old lab and 32.2Gy.cm2 for the new lab). The main reason for t ...
... carried out on two virtually identical systems that were installed approximately 5 years apart. Results indicated that patient doses were higher on the new lab despite cardiologist technique appearing to have improved (25.1Gy.cm2 for the old lab and 32.2Gy.cm2 for the new lab). The main reason for t ...
Scatter Correction Method for X-Ray CT Using Primary Modulation
... Abstract—An X-ray system with a large area detector has high scatter-to-primary ratios (SPRs), which result in severe artifacts in reconstructed computed tomography (CT) images. A scatter correction algorithm is introduced that provides effective scatter correction but does not require additional pa ...
... Abstract—An X-ray system with a large area detector has high scatter-to-primary ratios (SPRs), which result in severe artifacts in reconstructed computed tomography (CT) images. A scatter correction algorithm is introduced that provides effective scatter correction but does not require additional pa ...
Cone Beam Computed Tomography (CBCT) Dosimetry
... MC model of the OBI x-ray tube was built into the system and validated by measurements characterizing the cone beam quality in the aspects of the x-ray spectrum, half value layer (HVL) and dose profiles for both full-fan and half-fan modes. Using the validated MC model, CTDICB, dose profile integral ...
... MC model of the OBI x-ray tube was built into the system and validated by measurements characterizing the cone beam quality in the aspects of the x-ray spectrum, half value layer (HVL) and dose profiles for both full-fan and half-fan modes. Using the validated MC model, CTDICB, dose profile integral ...
Radiological Protection in Cone Beam Computed Tomography
... The International Commission on Radiological Protection (ICRP) provides recommendations and guidance on application of principles of radiological protection it establishes. This has been done through specific publications on the various uses of ionising radiation in medicine in various imaging and t ...
... The International Commission on Radiological Protection (ICRP) provides recommendations and guidance on application of principles of radiological protection it establishes. This has been done through specific publications on the various uses of ionising radiation in medicine in various imaging and t ...
LightSpeed™ VCT - Spectrum Medical X
... This manual supports the following configurations: LightSpeed VCT LightSpeed VCT XT LightSpeed VCT XTe © 2011 General Electric Company. All rights reserved. This product is certified as a LightSpeed™ Multislice CT System. The MHLW certified number is 21100BZY00104000 ...
... This manual supports the following configurations: LightSpeed VCT LightSpeed VCT XT LightSpeed VCT XTe © 2011 General Electric Company. All rights reserved. This product is certified as a LightSpeed™ Multislice CT System. The MHLW certified number is 21100BZY00104000 ...
optimisation and establishment of diagnostic
... The development of this thesis would not have been possible without the help of several friends that followed me from the first minute. To all of them my sincere thank you, for sharing outstanding moments and helping me to remove the stones from a long and winding road. To Profess ...
... The development of this thesis would not have been possible without the help of several friends that followed me from the first minute. To all of them my sincere thank you, for sharing outstanding moments and helping me to remove the stones from a long and winding road. To Profess ...
An X-ray Source Model and Characterization Method for Computing
... the software I used in this project. Through our close collaboration, I was able to devise a kv x-ray source characterization method and model that is easy to implement in a clinical medical physics setting. I would then like to thank my supervisor Dr. Mauro Tambasco, who provided the original idea ...
... the software I used in this project. Through our close collaboration, I was able to devise a kv x-ray source characterization method and model that is easy to implement in a clinical medical physics setting. I would then like to thank my supervisor Dr. Mauro Tambasco, who provided the original idea ...
Piranha Reference Manual - English - 5.5G
... Accessory to diagnostic X-ray equipment to be used as an electrometer. Together with external probes it is to be used for independent service and quality control, as well as measurements of kerma, kerma rate, kVp, tube current, exposure time, luminance, and illuminance within limitations stated belo ...
... Accessory to diagnostic X-ray equipment to be used as an electrometer. Together with external probes it is to be used for independent service and quality control, as well as measurements of kerma, kerma rate, kVp, tube current, exposure time, luminance, and illuminance within limitations stated belo ...
Avaliação de sistemas de controle automático de
... Figure 1 – The first generation has a pencil beam translation over the patient to reach an attenuation profile, which makes the imaging reconstruction system capable to distinguish different types of tissues and structures. (source: Hypermedia MS[16])................................................. ...
... Figure 1 – The first generation has a pencil beam translation over the patient to reach an attenuation profile, which makes the imaging reconstruction system capable to distinguish different types of tissues and structures. (source: Hypermedia MS[16])................................................. ...
dual energy computed tomography for proton therapy treatment
... The uncertainties in SPRs estimated using the kV-MV DECT were analyzed further and compared to those using the stoichiometric method. The uncertainties in SPR estimation can be divided into five categories according to their origins: the inherent uncertainty, the DECT modeling uncertainty, the CT im ...
... The uncertainties in SPRs estimated using the kV-MV DECT were analyzed further and compared to those using the stoichiometric method. The uncertainties in SPR estimation can be divided into five categories according to their origins: the inherent uncertainty, the DECT modeling uncertainty, the CT im ...
Imaging dose from cone beam computed tomography in radiation
... includes papers in peer-reviewed publications with complete methods and results sections. In addition to the absorbed dose from CBCT, the use of different quality beams other than the therapeutic megavoltage ones raises questions as to the magnitude of effective dose delivered to patient, and the ut ...
... includes papers in peer-reviewed publications with complete methods and results sections. In addition to the absorbed dose from CBCT, the use of different quality beams other than the therapeutic megavoltage ones raises questions as to the magnitude of effective dose delivered to patient, and the ut ...
Installation of Imaging Modalities
... • A patient ingests or is injected with a small amount of radioactive material. The radioactive material gives off gamma rays that can be detected by a special camera that produces computerized images ...
... • A patient ingests or is injected with a small amount of radioactive material. The radioactive material gives off gamma rays that can be detected by a special camera that produces computerized images ...
Beryllium Detection in Human Lung Tissue using Electron
... beryllium in lung tissue, including electron energy loss spectroscopy (6), laser microprobe mass analysis (7), and secondary ion mass spectrometry (8). Although highly sensitive, these modalities are relatively expensive and not widely available in the clinical setting. At least 1 g of lung tissue i ...
... beryllium in lung tissue, including electron energy loss spectroscopy (6), laser microprobe mass analysis (7), and secondary ion mass spectrometry (8). Although highly sensitive, these modalities are relatively expensive and not widely available in the clinical setting. At least 1 g of lung tissue i ...
Imaging of small amounts of pleural fluid. Part one
... costophrenic sulcus, but only with the presence of coexisting pneumoperitoneum. This is less reliable in practice, so we proposed the finding of a small meniscus sign in the posterior costophrenic angle as the sign of small pleural effusion on lateral views. Some authors13,19 also suggested that the ...
... costophrenic sulcus, but only with the presence of coexisting pneumoperitoneum. This is less reliable in practice, so we proposed the finding of a small meniscus sign in the posterior costophrenic angle as the sign of small pleural effusion on lateral views. Some authors13,19 also suggested that the ...
RADIATION MEDICINE QA
... as a 27-year-old after a serious illness, I thought about what I wanted to do Prof. Wilhelm Hammer, in my future professional life. 1885-1949, inventor of the relay-based Hammer doseI considered qualifying as a meter and founder of PTW university lecturer. But in the end, fate would have it that I m ...
... as a 27-year-old after a serious illness, I thought about what I wanted to do Prof. Wilhelm Hammer, in my future professional life. 1885-1949, inventor of the relay-based Hammer doseI considered qualifying as a meter and founder of PTW university lecturer. But in the end, fate would have it that I m ...
Product Catalogue 2013/2014 Dosimetry and QA
... as a 27-year-old after a serious illness, I thought about what I wanted to do Prof. Wilhelm Hammer, in my future professional life. 1885-1949, inventor of the relay-based Hammer doseI considered qualifying as a meter and founder of PTW university lecturer. But in the end, fate would have it that I m ...
... as a 27-year-old after a serious illness, I thought about what I wanted to do Prof. Wilhelm Hammer, in my future professional life. 1885-1949, inventor of the relay-based Hammer doseI considered qualifying as a meter and founder of PTW university lecturer. But in the end, fate would have it that I m ...
Cone-Beam Computed Tomography Examinations of
... practices should always be based on the principles of justification and optimisation. The afore-mentioned principles essentially state that the benefits of the examination should outweigh the potential detriment caused by the examination as well as that the dose to the patient should be as low as ca ...
... practices should always be based on the principles of justification and optimisation. The afore-mentioned principles essentially state that the benefits of the examination should outweigh the potential detriment caused by the examination as well as that the dose to the patient should be as low as ca ...
Criteria for Acceptability of Medical Radiological Equipment
... Failure to meet a suspension level will establish that the operation of the equipment involved is sufficiently poor to raise an alarm indicating action is required. The assessment up to this point will generally be a matter for the holder1. The equipment failing to meet the suspension level will hav ...
... Failure to meet a suspension level will establish that the operation of the equipment involved is sufficiently poor to raise an alarm indicating action is required. The assessment up to this point will generally be a matter for the holder1. The equipment failing to meet the suspension level will hav ...
KODAK DIRECTVIEW CR Mammography Feature User`s Guide
... The information contained herein is based on the experience and knowledge relating to the subject matter gained by Carestream Health, Inc. prior to publication. No patent license is granted by this information. Carestream Health reserves the right to change this information without notice, and makes ...
... The information contained herein is based on the experience and knowledge relating to the subject matter gained by Carestream Health, Inc. prior to publication. No patent license is granted by this information. Carestream Health reserves the right to change this information without notice, and makes ...
X-ray
X-radiation (composed of X-rays) is a form of electromagnetic radiation. Most X-rays have a wavelength ranging from 0.01 to 10 nanometers, corresponding to frequencies in the range 30 petahertz to 30 exahertz (3×1016 Hz to 3×1019 Hz) and energies in the range 100 eV to 100 keV. X-ray wavelengths are shorter than those of UV rays and typically longer than those of gamma rays. In many languages, X-radiation is referred to with terms meaning Röntgen radiation, after Wilhelm Röntgen, who is usually credited as its discoverer, and who had named it X-radiation to signify an unknown type of radiation. Spelling of X-ray(s) in the English language includes the variants x-ray(s), xray(s) and X ray(s).X-rays with photon energies above 5–10 keV (below 0.2–0.1 nm wavelength) are called hard X-rays, while those with lower energy are called soft X-rays. Due to their penetrating ability, hard X-rays are widely used to image the inside of objects, e.g., in medical radiography and airport security. As a result, the term X-ray is metonymically used to refer to a radiographic image produced using this method, in addition to the method itself. Since the wavelengths of hard X-rays are similar to the size of atoms they are also useful for determining crystal structures by X-ray crystallography. By contrast, soft X-rays are easily absorbed in air and the attenuation length of 600 eV (~2 nm) X-rays in water is less than 1 micrometer.There is no universal consensus for a definition distinguishing between X-rays and gamma rays. One common practice is to distinguish between the two types of radiation based on their source: X-rays are emitted by electrons, while gamma rays are emitted by the atomic nucleus. This definition has several problems; other processes also can generate these high energy photons, or sometimes the method of generation is not known. One common alternative is to distinguish X- and gamma radiation on the basis of wavelength (or equivalently, frequency or photon energy), with radiation shorter than some arbitrary wavelength, such as 10−11 m (0.1 Å), defined as gamma radiation.This criterion assigns a photon to an unambiguous category, but is only possible if wavelength is known. (Some measurement techniques do not distinguish between detected wavelengths.) However, these two definitions often coincide since the electromagnetic radiation emitted by X-ray tubes generally has a longer wavelength and lower photon energy than the radiation emitted by radioactive nuclei.Occasionally, one term or the other is used in specific contexts due to historical precedent, based on measurement (detection) technique, or based on their intended use rather than their wavelength or source.Thus, gamma-rays generated for medical and industrial uses, for example radiotherapy, in the ranges of 6–20 MeV, can in this context also be referred to as X-rays.