Download Test note for DCDC module

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Variable-frequency drive wikipedia , lookup

Alternating current wikipedia , lookup

Rectifier wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Stray voltage wikipedia , lookup

Electromagnetic compatibility wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Portable appliance testing wikipedia , lookup

Voltage regulator wikipedia , lookup

Power electronics wikipedia , lookup

Mains electricity wikipedia , lookup

Voltage optimisation wikipedia , lookup

Tektronix analog oscilloscopes wikipedia , lookup

Metadyne wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Test probe wikipedia , lookup

Opto-isolator wikipedia , lookup

Buck converter wikipedia , lookup

Transcript
Test note for DCDC module
Basic connection on Delta evaluation board
Fig-1
Test note
E-mail: [email protected]
http://www.deltaww.com/dcdc
P1
Test note for DCDC module
General measurement
1. Preparation for test:
1) Press the 4 clips on bottom side to make sure sense+/- terminal good contact with the Vin/Vo Pin;
2) Insert the module as Fig-3;
Fig-2 Bottom view
Fig-3 Top view
2. Output Voltage measurement:
Mesure output voltage between Vo sense+ and Vo sense- as shown on Fig-4.
Fig-4 Vout test point
3. Line/Load Regulation Test:
1) It’s better to have cooling fan beside the module, and measure output voltage at the moment of power
on or loaded, otherwise the temperature of module increases rapidly, and the temperature regulation will
affect the accuracy of the line/load regulation measurements.
2) Mesure output voltage between Vo sense+ and Vo sense- as shown on Fig-4.
Test note
E-mail: [email protected]
http://www.deltaww.com/dcdc
P2
Test note for DCDC module
4. Ripple and noise test:
1) A 20 MHz bandwidth oscilloscope is normally used for the measurement.
2) Use coaxial-cable connect between oscilloscope and BNC connector on evaluation board.
Fig-5 Ripple and noise test point
3) The conventional ground clip on an oscilloscope probe(see Fig-6) should never be used in this kind of
measurement. This clip, when placed in a field of radiated high frequency energy, acts as an antenna or
inductive pickup loop, creating an extraneous voltage that is not part of the output noise of the converter.
Fig-6 Probe
4) Another method is shown in Fig-7 in case of coaxial-cable/BNC is not available. The noise pickup is
eliminated by pressing scope probe ground ring directly against the -Vout terminal while the tip contacts
the +Vout terminal. This makes the shortest possible connection across the output termianls.
Fig-7
 For more detail specification, please refer to product datasheet or contact with Delta’s
technical support team.
Test note
E-mail: [email protected]
http://www.deltaww.com/dcdc