* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 1400-104 Relative Humidity/Air Temperature - LI
Survey
Document related concepts
Ground (electricity) wikipedia , lookup
Control system wikipedia , lookup
Three-phase electric power wikipedia , lookup
Buck converter wikipedia , lookup
Stray voltage wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Rectiverter wikipedia , lookup
Power MOSFET wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Voltage optimisation wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Alternating current wikipedia , lookup
Transcript
000 LI-1 Log ger Data ○ ○ ○ ○ ○ 1400-104 Relative Humidity/Air Temperature Sensor An alo g I/O mo de l LI-1 400 da taL OG G ER Se tup ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Es c View En ter A D 7 B E G J Installation Instructions 4 Q 1 R 0 9 F 5 L 2 Sh I N U C H K M X 8 6 Fc O V S Y W ift 3 T P EE t X Z On/ Off The 1400-104 Relative Humidity/Air Temperature Sensor requires a 7-28 VDC input power source and has a signal conditioned voltage output of 0-1V = -40 °C to 60 °C for air temperature and 0-1V = 0-100% for relative humidity. Mounting the Sensor in the 1400-201 Vented Instrument Enclosure 1. 2. Remove the protective yellow cap from the sensor. Secure the sensor in the mounting hole located in the center of the bottom of the instrument enclosure with the two plastic retaining rings and set screws (Figure 1). Position the end of the sensor so it is even with the bottom of the circular radiation shield under the enclosure. Set screw Interfacing to the LI-1400 Datalogger 1. 2. 3. 4. 5. 1400-201 Vented Instrument Enclosure Retaining rings Connect the brown wire (7-28 VDC power) to one of the two unregulated power supply terminals (UNREG). This terminal supplies the power to the sensor. Connect the blue wire (ground) to any ground (↓) terminal. Connect the narrow gauge black wire (temperature voltage signal) to one of the voltage signal channels (V1-4). Note that there is a second black wire, with a thicker shield, that should be connected to any of the ground (↓) terminals on the terminal strip. Connect the white wire (RH voltage signal) to one of the voltage signal channels (V1-4). Secure the cable to the strain relief slots at the top of the terminal strip, if desired. Humitter Radiation shield Figure 1. Align the end of the sensor with the bottom of the radiation shield. Configuring the LI-1400 Datalogger (Example) Connect the black wire to V1 and the white wire to V2. For temperature: 1. 2. 3. 4. 5. 6. 7. Configure V1 channel as General for air temperature. Enter a description, such as Air temp. Set Math = Poly(nomial) and press Ent(er). Set description as desired, a0 = -40, a1 = 100, a2-a5 = 0. When finished, press Esc to return to the main configuration list. Set Oper(ator) = none. Enter a Label such as C for the units. Configure any remaining parameters as described in the LI-1400 Instruction Manual. For relative humidity: 1. 2. 3. 4. 5. 6. 7. Configure V2 channel as General for relative humidity. Enter a description, such as RH. Set Math = Poly(nomial) and press Ent(er). Set a0 = 0, a1 = 100, a2-a5 = 0. When finished, press Esc to return to the main configuration list. Set Oper(ator) = none. Enter a Label such as RH for the units. Configure any remaining parameters as described in the LI-1400 Instruction Manual. Interfacing to the LI-1000 Datalogger 1. 2. 3. 4. Connect the brown wire (7-28 VDC power) to C1 on the 1000-05 Terminal Block or P1-5 on the 1000-10 Thermocouple Block. These terminals supply power to the sensor. Connect the blue wire (ground) to any ground terminal. Connect the black wire (temperature voltage signal) to one of the voltage signal channels such as A-3 on the 1000-05 Terminal Block or to one of the large copper posts (such as channel 4) on the 1000-10 Thermocouple Block. Connect the white wire (RH voltage signal) to one of the voltage signal channels such as A-4 on the 1000-05 Terminal Block or channel 5 on the 1000-10 Thermocouple Block. (over) Configuring the LI-1000 Datalogger (Example) For air temperature: For relative humidity: 1. 2. 3. 4. 5. 6. 1. 2. 3. 4. 5. 6. Configure channel 3 as Gen(eral) and press ENTER. Range = A. Set a0 = -40, a1 = 10, a2-a5 = 0. Math = OFF. Enter a desired label such as C. Configure remaining parameters as described in the LI-1000 Instruction Manual. Configure channel 4 as Gen(eral) and press ENTER. Range = A. Set a0 = 0, a1 = 10, a2-a5 = 0. Math = OFF. Enter a desired label such as RH. Configure remaining parameters as described in the LI-1000 Instruction Manual. Recalibration It is not necessary to send the 1400-104 sensor back to LI-COR for recalibration, as calibration of the RH sensor is done simply by replacing the sensor element. Specifications (HMP50) Relative Humidity Fig. 2. Temperature dependence Measuring range Operating range Typical accuracy at +20 °C 0...90% RH 90...98% RH Temperature dependence Sensor 0...98 %RH 0...100 %RH ±3% RH ±5% RH see Figure 2 Vaisala INTERCAP® Temperature Measuring range Operating range Typical accuracy at +20 °C Sensor -10...+60 °C -40...+60 °C ±0.6 °C, see Figure 3 Pt 1000 IEC 751 class B Fig. 3. Accuracy of temperature measurement General Output signal Power supply Current consumption Operating temperature range Storage temperature range Operating humidity range Sensor protection option Housing material Housing classification 0...1 V (equals 0...100 %RH and -40...+60 °C, i.e., 10 mV equals one %RH or °C). 7...28 VDC 2 mA typical -10...+60 °C -40...+60 °C 0...100 %RH membrane filter, part #DRW010525 plastic grid, part #DRW010522 ABS plastic IP 65 1 2 3 4 brown white blue black +VDC 7...28VDC 0...1V 0...100% RH -VDC 0...1V -40...+60 °C INTERCAP® is a registered trademark of Vaisala. Specifications subject to change without further notice. ® LI-COR, inc. ● Environmental ● 4421 Superior Street ● P.O. Box 4425 ● Lincoln, NE 68504 USA Phone: 402-467-3576 ● FAX: 402-467-2819 Toll-free 1-800-447-3576 (U.S. & Canada) E-mail: [email protected] www.licor.com DLA117-10/07