* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Smith Chart - Mitra.ac.in
Survey
Document related concepts
Transcript
Smith Chart 1 Smith Chart • Impedances, voltages, currents, etc. all repeat every half wavelength • The magnitude of the reflection coefficient, the standing wave ratio (SWR) do not change, so they characterize the voltage & current patterns on the line • If the load impedance is normalized by the characteristic impedance of the line, the voltages, currents, impedances, etc. all still have the same properties, but the results can be generalized to any line with the same normalized impedances 2 Smith Chart • The Smith Chart is a clever tool for analyzing transmission lines • The outside of the chart shows location on the line in wavelengths • The combination of intersecting circles inside the chart allow us to locate the normalized impedance and then to find the impedance anywhere on the line 3 Real Impedance Axis Smith Chart Imaginary Impedance Axis 4 Smith Chart • Impedance divided by line impedance (50 Ohms) • Z1 = 100 + j50 • Z2 = 75 -j100 • Z3 = j200 • Z4 = 150 • Z5 = infinity (an open circuit) • Z6 = 0 (a short circuit) • Z7 = 50 • Z8 = 184 -j900 • Then, normalize and plot. The points are plotted as follows: • z1 = 2 + j • z2 = 1.5 -j2 • z3 = j4 • z4 = 3 • z5 = infinity • z6 = 0 • z7 = 1 • z8 = 3.68 -j18 5 Smith Chart • Thus, the first step in analyzing a transmission line is to locate the normalized load impedance on the chart • Next, a circle is drawn that represents the reflection coefficient or SWR. The center of the circle is the center of the chart. The circle passes through the normalized load impedance • Any point on the line is found on this circle. Rotate clockwise to move toward the generator (away from the load) • The distance moved on the line is indicated on the outside 6 of the chart in wavelengths Toward Generator Constant Reflection Coefficient Circle Away From Generator Scale in Wavelengths Full Circle is One Half Wavelength Since Everything Repeats K. A. Connor RPI ECSE Department 7 Smith Chart Example • First, locate the normalized impedance on the chart for ZL = 50 + j100 • Then draw the circle through the point • The circle gives us the reflection coefficient (the radius of the circle) which can be read from the scale at the bottom of most charts • Also note that exactly opposite to the normalized load is its admittance. Thus, the chart can also be used to find the admittance. We use this fact in stub matching 8 Single Stub Matching • Load of 100 + j100 Ohms on 50 Ohm Transmission Line • The frequency is 1 GHz = 1x109 Hz • Want to place an open circuit stub somewhere on the line to match the load to the line, at least as well as possible. • First the line and load are specified. Then the step by step procedure is followed to locate the open circuit stub to match the line to the load 9 3 February 2004 K. A. Connor RPI ECSE Department 10 3 February 2004 K. A. Connor RPI ECSE Department 11 3 February 2004 K. A. Connor RPI ECSE Department 12 3 February 2004 K. A. Connor RPI ECSE Department 13 3 February 2004 K. A. Connor RPI ECSE Department 14 3 February 2004 K. A. Connor RPI ECSE Department 15 3 February 2004 K. A. Connor RPI ECSE Department 16 Smith Chart • Now the line is matched to the left of the stub because the normalized impedance and admittance are equal to 1 • Note that the point on the Smith Chart where the line is matched is in the center (normalized z=1) where also the reflection coefficient circle has zero radius or the reflection coefficient is zero. • Thus, the goal with the matching problem is to add an impedance so that the total impedance is the characteristic impedance 17