* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Final Design Review - Senior Design
Geophysical MASINT wikipedia , lookup
Multidimensional empirical mode decomposition wikipedia , lookup
History of electric power transmission wikipedia , lookup
Control system wikipedia , lookup
Current source wikipedia , lookup
Schmitt trigger wikipedia , lookup
Surge protector wikipedia , lookup
Buck converter wikipedia , lookup
Distribution management system wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Voltage regulator wikipedia , lookup
Stray voltage wikipedia , lookup
Alternating current wikipedia , lookup
Voltage optimisation wikipedia , lookup
Immunity-aware programming wikipedia , lookup
ARD, Carderock Division, Bayview,ID Project Professors: Dr. Herb Hess & Dr. Brian Johnson Final Design Review December 5, 2008 Jarred Coulter Vishu Gupta Zane Sapp Overview Project introduction DAQ Hardware Sensors Software Testing/Calculations Recommended System Future Work/Conclusions 2 Project Introduction 3 Background The Acoustic Research Detachment (ARD) of the Naval Surface Warfare Center, Carderock Division (NSWCCD) is located at Bayview, ID. The Advanced Electric Ship AESD Demonstrator (AESD) is a ¼ scale destroyer used to monitor acoustics and test electric propulsion technologies. 4 Project Goals • Design a Data Acquisition System (DAQ) to interface with the existing systems on the AESD to: • Manage and display battery data from the propulsion and UPS systems • Data for voltages, currents, and temperatures • Correlate above data with the GPS data available • Graphical display • On board data storage buffer • Expandable Architecture 5 Design specifications • Ungrounded system • 120 V AC 25Amps available • Maximum 12 hours of data storage • System needs to be space efficient/ rack mountable • Expandable Architecture • Integrate with existing sensors and GPS already in place on the AESD 6 System Architecture 7 DAQ Hardware 8 NI DAQ Lab Hardware System Components Data Acquisition System From National Instruments PXI/SCXI Combination Chassis (1) MXI Express Link (2) M-Series DAQ and PXI/SCXI Chassis Controller (3) 32-Channel Input Module/Multiplexer (4) I/O Connector M-Series DAQ (Not Shown) (5) Cast Screw Terminal Block for SCXI-1104C with Cold Junction Compensation (6) 9 NI Hardware Features • M-Series Data Acquisition Device • 333 ks/s • Up to 280 channels per DAQ device • 16-Bit ADC resolution • MXI-Express Connection • Bandwidth: 110 Mb/s and up to 250 Mb/s • PC and laptop compatible • High bandwidth allows for large channel count through multiple chassis • SCXI/PXI • Variety of Input Modules for wide range of applications • Rugged chassis for industrial applications 10 LabVIEW 8.2 • Built in Virtual Instruments (VI) for data acquisition, analysis, storage and display • Mathscript capabilities • Stores all data in an ASCII text file called LabVIEW Measurement File (LVM) • DAQmx and DAQ Assistant for easier programming 11 Sensors 12 Sensors Overview • LEM Current Transducers • Accurately measure wide range of currents • Cost ≈ $400 per unit • Hall Effect Voltage Transducers • Capable of accurately handling very high voltages • Cost ≈ $250 per unit • Isolation Amplifier Type Voltage Transducers • Designed • Cost ≈ $5 per unit • K-type Thermocouple Temperature Sensors • Wide measurement range • Cost ≈ $1.00 per ft 13 LEM Current Transducer LEM DC-C10 Features • DC Current Transducer • 3 Jumper Adjustable Ranges: 5, 10, 20 Amp Max • Supply Voltage: 20-50 VDC • ±1% Accuracy at 25 ̊C 14 ABB Voltage Sensor LEM CV 3-500 Features • Closed Loop Hall Effect • • • • Voltage Transducer Measuring Range: 0 to 500 V Output Voltage: 0 to 10 V (Max) Supply Voltage: ± 15 VDC ± 0.2% Accuracy at 25 ̊C 15 Designed Sensors Designed Voltage Sensors Low power consumption Only one voltage reference or ground reference Simple design Voltage Sensor Schematic Linear input to output 16 Voltage Sensor Results Horz = 12V Vert = 12V Simulation Results Experimental Results 17 Temperature Sensors K-type thermocouples used • Temperature range: -452.2˚F to 1562˚F • SCXI Modules designed for Thermocouple inputs with integrated Cold Junction Compensation ICs • Cost is approximately $1.00/ft for shielded thermocouple wire 18 Software 19 LabVIEW Control for the DAQ Program provides for: Easy control for data acquisition Real-time data display Save the data to a file in a specified location File can be opened with different analysis tools User comments can also be added to the file. Saved data is time and location stamped Errors observed on system are saved as a text file- ‘Error Log’ 20 Flow diagram of the code Check for valid GPS signal Acquire data Display Voltage and Current data as graphs Numerical display for temperature Save data to file Check for stop condition 21 Front panel: Control/Indicator tab Designed for the user to control the System and test Divided into different tabs on the screen Instructions Front Panel: Control Control/Indicator System error Voltage graphs Current graph Temperature readings GPS Front Panel: Control 22 TESTING & CALCULATIONS 23 Lab Setup Thermocouples GPS ABB Voltage Sensor Current LEM Designed sensors Battery Bank NI DAQ 24 Testing Tests run on the system Period: 2 hours Measured Battery Voltage (V) String Current (A) Battery temperature (°F) Measurements taken on 9 channels Current LEM ABB Voltage Sensor Opto-coupler sensors : 3 Thermocouples : 4 Error observed: None 25 Test Results 26 Calculations LATENCY 1 sec with the GPS running. <100ms without GPS Dependant on sampling frequency POWER CONSUMPTION Lab Model: 510 Watts Including PC power consumption of 60Watts 27 Recommended System 28 System Architecture Flow: Recommended System 29 Recommended System: Calculations The cost analysis for a full system with all the required hardware and software was done Complete system includes: Data Acquisition Cards PC Controller and External Hard Drive Thermocouple/Voltage Input Modules Multi Chassis Adapter MXI Express Connector PXI and SCXI Chassis LabVIEW COST ANALYSIS Total system cost: $140, 427.75 Cost per channel: $87.17 $68 per channel for additional channels POWER CONSUMPTION 1350 Watts Note: detailed cost analysis is provided in the final report. Also given at the end of the presentation 30 Future Work/ Conclusions 31 Future Work Integrate control of the sensors onto a Printed Circuit Board (PCB). Feedback from the ARD for actual integration with the GPS system on-board the AESD. Type of communication Data format Thermocouple Cards should be integrated into the lab model Integrating real-time system with charging schemes of the propulsion batteries Expanding LabVIEW Event triggering/alarms on the monitored channels For the recommended system Post processing 32 Conclusions System Capabilities: Monitoring propulsion batteries and UPS batteries Acquiring GPS data Data and Error Log saved as text files Sensors Voltage Current Temperature LabVIEW Control the DAQ Monitor the system 33 Acknowledgements ARD Alan Griffitts Frank Jurenka Karl Sette Research Group Justin Schlee John Finley Leo Luckose James Randall University of Idaho Dr. Brian K. Johnson Dr. Herb Hess Dr. Chris Wagner Arleen Furedy Karen Cassil Beth Cree Dorota Wilk 34 Temperature sensors: Amplifier Amplifier adds a gain of 924.3 This is then scaled in LabVIEW Explained later on in the presentation Batteries Thermocouple measurement Amplifier Amplified Thermocouple Voltage LabVIEW (scale down) DAQ 35 Temperature data Modify amplified signal to Amplified signal from SCXI 1104-C Output temperature on thermocouple 1 obtain temperature readings. The amplified signal is Built –in VI for converting Voltage to temperature scaled down by the gain factor Built in VI for converting voltage to temperature Outputs the temperature The units can be changed 36 Detailed cost analysis sheet of the recommended system 37 Detailed cost analysis sheet of the system used Put in the cost sheet that we had for the system we are using right now. 38