Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
VS501Z Hot Sheet 9XcYfX@ejkild\ekj Jpjk\dGE,+*,-$'( System Model # VSP-VS501Z-CCAH Software Version # 35 EPN # 1801 Base PCBA - PN 54357-01 PCB VS500Z - PN 22972 Rev C or D Base Panels Duplex Digital – PN 54093 Lite Duplex – PN 54094 Template used: 40600_C.pdf 05/04/2006 54356_01-97_B.pdf 06/14/2006 54356_01-97_B Basic System Features and Functions Power Requirements • 120/240VAC, 60Hz, 16/32A, Class A GFCI-protected service (Circuit Breaker rating = 50A max.) • 4 wires (hot, hot, neutral, ground) System Outputs (As Configured) • • • • • • • 120V Pump 1, 2-Speed 120V Blower 120V Circ Pump 120V Ozone 12V Spa Light 120V AV (Stereo) 240V 5.5kW Heater Additional Options • IR Receiver Module Connects to terminal J1 or J2 K8 W3 K5 W2 J1 J1A • Ozone Generator Connects to terminal J29 J10 • MoodEFX Lighting Connects to Spa Light terminal J20 • FiberEFX Lighting Connects to Spa Light terminal J20 FUSE • Full Feature Dolphin Remote and Spa-only Dolphin Remote J18 J2A 1 U4 2 3 J12 J2 • Stereo System Connects to A.V. terminal J50 J13 J60 J22 EXT. RLY AUX. F J7 J8 SEN. A SEN. B BALBOA INSTRUMENTS, INC. 2-SPD J44 VS500Z EXT RLY P/N 22972 REV D VAC MADE IN U.S.A COPYRIGHT 2005 54356_01-97_B Wiring Configuration NEUTRAL WHITE W3 R FUSE 3A 250V W W B F1 G K5 W2 J1 J1A J10 VS50x mode K3 K2 TB1 J36 J43 J37 F2 RED AC Balboa 2 3 J12 J2 J35 HTR2 J100 HTR1 J101 J13 E.GND J32 J33 J34 1 U4 J18 J2A HOT RED K4 TORQUE RANGE FOR TB1: 27-30 IN. LBS. J20 W J46 R B W K8 K9 T1 HOT BLACK Jumper needed for 120V systems Remove for 240V Systems G B W G W4 R R R B W G W7 W1 F4 FUSE .3A 250V J29 12V Light J16 J25 J63 J64 J15 J47 Ozone J11 J66 J65 Blower Audio Visual 2-Spd P1 WHT T AC FUSE 20A 250V F7 J50 K1 B J23 J17/26 J62 W J61 G K6 BLK AC F5 Circ.Pump CLASS G FUSE 30A J60 J22 EXT. RLY AUX. F J6 S1 TST SWITCHBANK A J7 J8 SEN. A SEN. B BALBOA INSTRUMENTS, INC. 2 SPD J44 VS500Z EXT RLY P/N 22972 REV D VAC MADE IN U.S.A COPYRIGHT 2005 5.5 kW Wiring Color Key 120 Volt Connections 240 Volt Connections Black AC Jumpers 12 Volt Connections Relay Control Wires PCB Revision History C Production Release D Added Red AC connections J36 & J37; Added Aux Heater connections J100 & J101 54356_01-97_B Configuration Options K6 BLK AC F5 J61 4 J62 5 J23 6 7 FUSE 20A 250V F7 J50 K1 8 9 J47 J29 NEUTRAL WHITE K4 R W W G W B B J18 D J2 J43 J13 J60 HTR2 E.GND HTR1 J101 2 Output Features + W2 + W2 2 3 J12 F2 J100 J50 + W4 J17/26 + W7 B C U4 J35 J37 Balboa + W1 K5 W2 J1A 1 K3 K2 RED AC 1 A J2A TB1 E W R B W J1 G R J17/26 W3 F1 J10 HOT RED TORQUE RANGE FOR TB1: 27-30 IN. LBS. J36 J20 K8 K9 T1 F4 FUSE .3A 250V J32 J33 J34 J47 J29 W7 HOT BLACK C J23 J20 W1 B D G J16 J25 J63 J64 J15 G G J11 W4 J66 J65 W WHT AC B B R A W R CLASS G FUSE 30A 3 FUSE 3A 250V 2 J46 1 3 4 5 J22 J6 S1 TST SWITCHBANK A 6 EXT. RLY 7 AUX. F J7 SEN. A BALBOA INSTRUMENTS, INC. 2-SPD J44 VS500Z EXT RLY P/N 22972 REV D J8 SEN. B 8 E VAC MADE IN U.S.A COPYRIGHT 2005 9 Quadrant – 2-Speed Pump 1 4-A – OR 1-Speed Pump 1 with DIP Switch A5 – Audio Visual power output (Hot) 6-A – 1-Speed Blower (W3 to J46) 6-B – OR Single-Speed Pump 2 or Pump 3 (W3 to J62) – Circ Pump 8-A – Ozone (Same voltage as Circ Pump, if used) 9-A – Note X-03 option at right for retro fit – Spa Light (12V only) 9-A System can be factory configured for either a Duplex Topside Panel or a Serial Standard Panel. Balboa Instruments Incorporated X-Mount P PN 53933 Used for mounting any Expander Board in a plastic enclosure. Standoffs attach to heater mounting bracket. 54356_01-97_B Expander Options K1 J6 J1 W G R B R B W1 F30A 250V W F1 J6 J7 G J2 J4 W12 X-P PN 53544 Used for a 1-speed Pump output. Represents a VS510Z. R B W X-P231 PN 53681 Can replace the X-P in cases where branch circuit protection is needed for high amperage devices that would over-burden power input fuse F5 (1-A) on the main PCBA. • J6 on the X-P231 connects directly to Black AC by using J66 or J65 on the main board (1-B). • Connect J7 wire on the X-P231 to J60 on the main board (7-E). • Connect W1 on the X-P231 to Red AC on the main board (2-D). G K1 J6 W12 F5 F10A 250V J3 J2 PN 53310 X-B Used for a Blower output ONLY. Represents a VS512Z. J1 R B W1 F30A 250V W F1 J6 G J7 K1 J6 R B W G R B W G X-P332 PN TBD Used for an additional 2-speed Pump output. Represents a VS521Z. J7 J2 J4 J5 W12 To J17/26 (Blower/P2) VS-P2 Adapter Wire PN 25339 To J5 on X-O3 • J6 on the X-P332 connects directly to Black AC by using J66 or J65 on the main board (1-B). • Connect J7 wire on the X-P332 to J13 on the main board (9-E). • Connect W1 on the X-P332 to Red AC on the main board (2-D). NOTE Regarding J12 (Quadrant 9-D): When J12 on the Main Board is jumpered on pins 2 & 3, the system is in VS50xZ compatibility mode. X-2SP Kit PN 53913 Adapter PN 25339 is used in conjuction with an X-O3 to run a 2-speed pump 2. • J4 connects to Black AC (3-A) using J61 or J62 on main board. • Connect 2-speed pump to J7 on X-03. No Blower is available when this kit is used. Represents a VS511Z. If J12 on the Main Board is jumpered on pins 1 & 2, the system is in VS51xZ/VS5xxSZ/VS5xxDZ compatibility mode. Document PN 40540_H 06-14-2006 54356_01-97_B DIP Switches and Jumpers SSID # 100 63 35 VS50x Compatible J12 1 A1, Test Mode OFF A2, Mode changes allowed A7, J17/26, J, T, L A10, High Amp mode DIP Switch Key A1 ................ A2 ................ ................ A3 ................ ................ A4 ................ A5 ................ ................ A6 ................ ................ A7 ................ ................ A8 ................ ................ A9 ................ ................ A10 ................ ................ 2 3 J43 Memory Reset Test Mode (normally Off) In “ON” position, Standard mode only In “OFF” position, Std/Ecn/Sleep mode changes allowed In “ON” position, use Mini Panel In “OFF” position, use Digital Duplex or Light Duplex panel Aux Freeze (must be OFF) In “ON” position, Two-speed pump 1 In “OFF” position, One-speed pump 1 (A9 must be On and a circ pump installed) In “ON” position, 50Hz operation In “OFF” position, 60Hz operation In “ON” position, Button layout will be: Jets, Light, Down, Up with J17/J26 equipment on 1-button Aux panel** In “OFF” position, Button layout will be: J17/J26 equipment, Jets, Temp, Light In “ON” position, temperature is displayed in degrees Celsius In “OFF” position, temperature is displayed in degrees Fahrenheit In “ON” Position, 24 Hour Circ Pump with 3ºF shut off In “OFF” position, no circ pump In “ON” Position, heater is disabled while any high-speed pump or blower is running (low amperage mode) In “OFF” position, heater can run while any/all high-speed pumps or blowers are running (high amperage mode) * Blower or second pump is not optional. For no blower, use VS500Z. ** J2 on Main Board must be a 6-pin connector. Jumper Key J12 Jumper on Pin 1 and 2 will enable VS51x compatibility mode. Jumper on Pin 2 and 3 will enable VS50x compatibility mode. J43 When jumper is placed on 2 pins during power-up, system will reset persistent memory. Leave on 1 pin only to enable persistent memory feature. 54356_01-97_B Ozone Connections Ozone Connector Voltage: The VS500Z circuit board is factory configured to deliver a preset voltage (120V or 240V) to the on-board ozone connector (J29). See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage. For 240V output W2 connects to Red AC and for 120V output W2 connects to White AC. The voltage to the ozone connector can be changed in the field if required. W2 just needs to be set for the required voltage. WARNING: Changing the voltage of the ozone connector also effects the voltage supplied to the circ pump connector (J47). Any equipment controlled by that connector may be damaged if the wrong voltage is selected. Balboa Ozone Generator: If the board is set up to operate a 120V ozone generator, the connector on the ozone generator is likely to be configured correctly, but should be compared to the illustration below. If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next to the green ground wire as described below. Note: A special tool is required to remove the pins from the connector body once they are snapped in place. Check with your Balboa Account Manager for information on purchasing a pin-removal tool. Balboa Ozone connector configuration for 120V 60Hz B Black conductor Use this slot for the leftover Red conductor Install the White conductor here for 120V ozone Green (ground) conductor G Balboa Ozone connector configuration for 240V 60Hz B Black conductor Use this slot for the leftover White conductor Install the Red conductor here for 240V ozone Green (ground) conductor G 54356_01-97_B Duplex Panel Configurations Blower Set Electronic Spa Controls Heat Light Jets LCD Duplex Digital System Duplex Digital PN 54093 with Overlay PN 10668 • Connects to Main Panel terminal J1 Heat Blower Jets Electronic Spa Controls LCD Lite Duplex System Temp Light Lite Digital PN 54094 with Overlay PN 10669 • Connects to Main Panel terminal J1 Several configurations of the panels shown above can be created as custom parts. Separate Temperature Up and Down buttons can be done if no Blower is present, or if Blower is on a 1-button Aux panel and J2 is 6-pin connector. 54356_01-97_B