Download GIGAVAC GX46, EPIC High Power DC Contactor

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Spark-gap transmitter wikipedia , lookup

Mercury-arc valve wikipedia , lookup

Three-phase electric power wikipedia , lookup

Power inverter wikipedia , lookup

Loudspeaker wikipedia , lookup

Audio power wikipedia , lookup

Electrical ballast wikipedia , lookup

Electric machine wikipedia , lookup

Electrification wikipedia , lookup

Islanding wikipedia , lookup

Stepper motor wikipedia , lookup

Ohm's law wikipedia , lookup

Power factor wikipedia , lookup

Rectifier wikipedia , lookup

Electric power system wikipedia , lookup

Current source wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Brushed DC electric motor wikipedia , lookup

Electrical substation wikipedia , lookup

History of electric power transmission wikipedia , lookup

Opto-isolator wikipedia , lookup

Surge protector wikipedia , lookup

Voltage regulator wikipedia , lookup

Voltage optimisation wikipedia , lookup

Multimeter wikipedia , lookup

Power engineering wikipedia , lookup

Power MOSFET wikipedia , lookup

Inductor wikipedia , lookup

Stray voltage wikipedia , lookup

Power electronics wikipedia , lookup

Transformer types wikipedia , lookup

Wireless power transfer wikipedia , lookup

Metadyne wikipedia , lookup

Distribution management system wikipedia , lookup

Relay wikipedia , lookup

Loading coil wikipedia , lookup

Buck converter wikipedia , lookup

Magnetic core wikipedia , lookup

Mains electricity wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Rectiverter wikipedia , lookup

Alternating current wikipedia , lookup

Tesla coil wikipedia , lookup

Coilgun wikipedia , lookup

Ignition system wikipedia , lookup

Resonant inductive coupling wikipedia , lookup

Transcript
G X46
600+ Amp 12-800 Vdc Contactor
FEATURES
Rugged EPIC® seal rated to 175°C – Reduced risk of fire or meltdown in over current conditions.
The same technology used for advanced aerospace programs.
Hermetically sealed – Designed to meet: UL1604 for Class I & II, Div 2 and Class III for use in hazardous
locations, IP67 for temporary water immersion for 30 min, SAE J1171 - external ignition protection, and
ISO8846 for protection against ignition around flammable gasses.
High Efficiency Dual DC Coils – Very low 12, 24 or 48 VDC continuous coil power with no EMI emissions or cross- talk on your system control power. Ideal for battery powered systems or where low power is needed.
Built-in coil suppression for all DC coils – Saves you engineering time and parts cost to add external coil suppression.
Stainless steel screws, washers and mounting inserts, for years of corrosion free service.
Not position sensitive – can be mounted in any position for ease of installation.
ADVANCED SWITCHING SOLUTIONS
Rev 4
10/23/15
600+ Amp 12-800 Vdc
G X46
EPIC® Hermetic Sealed DC Contactor
POWER SWITCHING AND
CURRENT CARRY RATINGS
PRODUCT SPECIFICATIONS
Contact Arrangement
Main
Auxilary (2A, 24VDC)1
Mechanical Life
Contact Resistance2
Max
Typical
Operate Time3
Max
Typical
Release Time, Max
Insulation Resistance4
Dielectric At Sea Level (Leakage < 1mA)
Shock, 1/2 Sine, 11ms
Vibration, Sinusoidal (500-2000 Hz Peak)
Ambient Temp Range
Operating5
Storage
Weight, Typical
Environmental Seal
Salt Fog
Units
Data
Form X
Form A or B
Cycles
SPST-NO
SPST-NO or
SPST-NC
1,000,000
mohms
mohms
0.3
0.11 to 0.2
ms
ms
ms
Mohms
VRMS
G peak
G
20
13
7
100
2,200
20
15
DC POWER SWITCHING CYCLES9
1,000,000
100,000
CYCLES
Specifications
10,000
1,000
100
˚C
-55 to +85
˚C
-70 to +150
Kg (Lb)
0.96 (2.1)
Exceeds IP67 & IP69K
MIL-STD-810
10
0
100
200
24V
F
12 VDC
24 VDC
48 VDC
Coil Voltage, Max
16 V
32 V
64 V
Pick-Up Voltage, Max6, 8
8V
16 V
30 V
0.5 to 4.5 V
0.5 to 7.5 V
2 to 15 V
3.8 A
1.9 A
0.9 A
Coil Current7
0.64 A
0.32 A
0.16 A
Coil Power7
7.8 W
7.8 W
7.8 W
Pick-Up Current, Max (75 ms)
6, 7
600
300V
450V
600V
800V
Internal Coil Suppression
with 85ºC terminal temperature rise
10,000
600A max
400MCM conductor
TIME (sec)
C
Drop-Out Voltage
500
CURRENT CARRY vs TIME
B
Coil Voltage, Nominal
400
CURRENT (A)
COIL RATINGS at 25˚C
Coil P/N Designation
300
1,000
100
CONTROL CIRCUIT
Coil Back EMF
Transients, Max (13 ms)
Reverse Polarity
55 V
55 V
125 V
±50 V
±50 V
±75 V
16 V
32 V
64 V
10
0
1,000
2,000
3,000
CURRENT (A)
G I G AVA C ® - 6 3 8 2 R o s e L a n e - C a r p i n t e r i a , C A 93 013 - p h +1- 8 0 5 - 6 8 4 - 8 4 01 - f a x +1- 8 0 5 - 6 8 4 - 8 4 02
i n f o @ g i ga v a c.c o m - w w w.g i ga v a c.c o m - © C o p y r i g h t 2 0 03 -2 014 G I G AVA C, L LC.
600+ Amp 12-800 Vdc
EPIC® Hermetic Sealed DC Contactor
G X46
DIMENSIONS
2X
3.74
95
0.50
3X 12.7
2X
3.11
79
2X
0.51
13
2.36
60
1.00
25.4
4.35
110.5
4X
0.33
8.5
T1 (AUX)
X1 (COIL + )
X2 (COIL - )
5.35
135.9
2X
0.32
8
T2 (AUX)
1.14
2X 28.8
3.47
2X 88.2
3.74
94.9
4.49
114
0.35
9
Mounting
Power Connection
M8 [5/16in] Bolts (not incl.)
M12 Hardware
Torque 2-4 Nm [18-35in-lb]
Torque 23-34Nm [200-300in-lb]
Power Contacts
A2(+)
Case Material
Coil/Auxiliary Connection
DuPont Zytel FR50
(25% Glass Filled Nylon)
18-8 Stainless Steel Hardware
M4x.7 6mm Phillips Machine Screw
Internal-Tooth Washer
Auxiliary contacts
(optional)
NO:
T1
T2
A1(-)
X2(-)
NC:
T1
T2
X1(+)
Torque .75Nm [6.6in-lb] max
G I G AVA C ® - 6 3 8 2 R o s e L a n e - C a r p i n t e r i a , C A 93 013 - p h +1- 8 0 5 - 6 8 4 - 8 4 01 - f a x +1- 8 0 5 - 6 8 4 - 8 4 02
i n f o @ g i ga v a c.c o m - w w w.g i ga v a c.c o m - © C o p y r i g h t 2 0 03 -2 014 G I G AVA C, L LC.
600+ Amp 12-800 Vdc
EPIC® Hermetic Sealed DC Contactor
G X46
PART NUMBER SYSTEM
GX46
B
Coil Voltage
B = 12 Vdc, Internal
Coil Suppression
D
B
C = 24 Vdc, Internal
Coil Suppression
Auxiliary
Contact
1 Auxillary contact rating is 2A, 24Vdc Resistive load, 100,000
cycles. Minimum current is 0.1mA, 5V. The auxiliary contact is
mechanically linked to the main power contacts.
2 Contact resisitance measured at currents higher than 100A.
3 Operation time is measured at 25°C and includes maximum
7ms bounce.
F = 48 Vdc, Internal
Coil Suppression
Coil
Termination
Notes & Definitions:
4 Insulation resistance is 50 Mohms after life.
D = Coil Screw, M4
Blank = None
B = SPST,
Normally Open
C = SPST,
Normally Closed
APPLICATION NOTES
• Contactors feature internal transorb for coil suppression. No external
diodes should be added across the coil. The use of additional external coil
suppression can slow the release time and invalidate the life cycle ratings,
or can cause the contactor not to be able to interrupt the maximum current
specified. If lower coil back EMF is required, please contact GIGAVAC for
assistance.
• Power switching lifecycles are based on current flow from A2(+) to A1(-).
For best breaking performance, the contactor should be installed so that
current flows from A2(+) to A1(-). There are cases where the contactor will
interrupt power in the opposite direction but please contact GIGAVAC to
confirm suitability. Direction of current flow is not relevant during make
or when flowing on closed contacts. For bi-directional contactors, please
contact GIGAVAC.
5 Contactor can operate up to 125°C in special cases - contact
GIGAVAC for details.
6 Contactor has two coils. Both are used for pick-up, and
then in approximately 75 milliseconds, one coil is electronically
removed from the coil drive circuit. The remaining coil supplies
low continuous hold power sufficient for the contactor to meet
all of its specified performance specifications. This provides low
coil power without PWM electronics that can cause EMI emissions
and/or cross-talk on control power.
7 Contactor is operated by a coil that changes resistance
with temperature. Since pick-up current, coil current and coil
power are specified at nominal voltage, they will be lower than
indicated at temperatures above 25°C and higher than indicated
at temperatures below 25°C. Similarly, pick-up and drop-out
voltages will be higher than indicated at temperatures above
25°C and lower than indicated at temperatures below 25°C.
8 For pick-up testing of contactors with dual coils, the voltage
can not be ramped up slowly, but must be applied instantly to at
least the maximum pick-up voltage. Otherwise, the contactor will
not pick-up.
9 For AC power switching cycles, contact factory. Limit make
current to 1000A to avoid contact welding.
• Applications with capacitors will require a pre-charge circuit.
• Electrical life rating is based on resistive load with 27µH maximum
inductance in circuit. Because your application may be different, we
suggest you test the contactor in your circuit to verify life is as required.
• End of life is defined as when the dielectric, insulation resistance or
contact resistance fails the specifications listed.
G I G AVA C ® - 6 3 8 2 R o s e L a n e - C a r p i n t e r i a , C A 93 013 - p h +1- 8 0 5 - 6 8 4 - 8 4 01 - f a x +1- 8 0 5 - 6 8 4 - 8 4 02
i n f o @ g i ga v a c.c o m - w w w.g i ga v a c.c o m - © C o p y r i g h t 2 0 03 -2 014 G I G AVA C, L LC.