Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Product Safety Assessment UCAR Propylene Glycol Aircraft Deicing & Anti-Icing Fluids Select a Topic: Names Product Overview Manufacture of Product Product Description Product Uses Exposure Potential Health Information Environmental Information Physical Hazard Information Regulatory Information Additional Information References Names • • • • • CAS No. 57-55-6 [Propylene glycol (PG)] PG Type I Aircraft Deicing Fluid (ADF) UCAR™ PG ADF Concentrate UCAR PG ADF Dilute “55/45” UCAR FlightGuard AD-49 anti-icing fluid • PG Type IV Aircraft Anti-icing Fluid (AAF) • SAE AMS 1428 PG-based Type IV aircraft anti-icing fluid • SAE AMS 1424 PG-based Type I aircraft deicing fluid Back to top Product Overview • Dow manufactures propylene glycol (PG)-based aircraft deicing fluids (ADF) under the trade name UCAR PG ADF and a PG-based aircraft anti-icing fluid (AAF) under the trade name UCAR FlightGuard™ AD-49 PG AAF. These products conform to industry standards set by the Society of Automotive Engineers (SAE) International, including Aerospace Material 1 Specification (AMS) 1424 and AMS 1428. For further details, see Product Description. ADFs are commercial products used exclusively for the removal of snow, ice, and frost from 2 the exterior surfaces of aircraft. AAF is typically applied following aircraft deicing or during active precipitation to prevent additional snow or ice build-up over an extended period of time. AAF can also be used as a preventive by applying to dry aircraft when overnight frost is 3 forecast. For further details, see Product Uses. Eye contact with these fluids may cause slight, temporary irritation, although corneal injury is unlikely. Prolonged skin contact is essentially nonirritating. Repeated contact may cause flaking and softening of the skin. At room temperature, exposure to vapor is minimal; however, 4 vapor from heated material may cause respiratory irritation and other effects. For further details, see Health Information. Worker exposure is possible during product formulation or during aircraft deicing or anti-icing 4 operations. These fluids are commercial-grade products and are not available for home use. For further details, see Exposure Potential. These products are thermally stable at typical storage and use temperatures. Some components of these products can decompose at elevated temperatures, causing pressure build-up in closed systems. Avoid contact with strong acids, strong bases, and strong 4,5 oxidizers. Areas sprayed with these fluids (such as the tarmac) may become slippery. For further details, see Physical Hazard Information. • • • • Back to top ® Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow Revised: June 15, 2015 The Dow Chemical Company Page 1 of 6 Product Safety Assessment: UCAR Propylene Glycol Aircraft Deicing and Anti-Icing Fluids Manufacture of Product • Capacity – Dow is a large producer of propylene glycol (PG). Dow has production facilities in the United States, Germany, Brazil, and Australia. Total world consumption of PG in 2003 6 was estimated at 1.2 million metric tons (2.6 billion pounds). • Process – Most commercial production of propylene glycol is by non-catalytic hydrolysis of propylene oxide using high temperature and high pressure. These products are formulated with propylene glycol as the main ingredient. Water, corrosion inhibitors, wetting agents, and dyes are added to provide the desired combination of properties for the end use of the product. Thickeners are also added to the Type IV aircraft anti-icing fluid (AAF). Back to top Product Description2,4,7 The primary ingredient in these products is propylene glycol (PG). PG is a colorless, odorless liquid. For further information about PG, refer to the Propylene Glycol Product Safety 8 Assessment or the relevant Safety Data Sheet. Dow manufactures two PG-based aircraft deicing fluids: UCARTM PG ADF Concentrate and UCAR PG ADF Dilute “55/45”. These formulations are orange liquids with a sweet odor and conform to all technical requirements of SAE AMS 1424 for SAE Type I aircraft deicing/anti-icing fluids, as well as specifications from aircraft manufacturers Douglas and Boeing. In addition to propylene glycol, they contain water, corrosion inhibitors, wetting agents, and orange dye. UCAR PG ADF Concentrate contains approximately 88% PG and must be diluted prior to use. UCAR PG ADF Dilute “55/45” is a ready-to-use fluid with a freezing point of about –36°C (–32.8°F). Dow’s anti-icing fluid, UCAR FlightGuard AD-49 AAF, is a green liquid with a mild, sweet odor that conforms to all technical requirements of SAE AMS 1428 for SAE Type IV aircraft deicing/anti-icing fluids. This product contains PG, water, corrosion inhibitors, wetting agents, thickeners, and green dye. Undiluted UCAR FlightGuard AD-49 AAF has a freezing point of about –36°C (–33°F). Use of UCARTM PG-based Deicing Fluids and Anti-icing Fluids12 Back to top Product Uses9,10,11,12 Aircraft Deicing fluids (ADF) – ADFs are used for removal of snow, ice, and frost from the exterior surfaces of aircraft. ADFs are normally applied hot and sprayed directly onto aircraft surfaces, especially wings and other control surfaces, immediately preceding takeoff. Type I Deicing Fluid 80% Type IV Antiicing Fluid 20% Anti-icing fluid (AAF) – During periods of active precipitation (snow, sleet, freezing rain) AAF is applied following the ADF operation. In addition to deicing functionality, it provides protection against the build-up of new snow or ice. It is designed to coat the aircraft exterior as a thick film, absorbing snow or freezing rain. It prevents absorbed precipitation from refreezing and also absorbs residual ADF from prior deicing. During takeoff, the AAF flows off the aircraft exterior. AAF can also be applied to dry aircraft as a preventive if overnight frost is expected. Back to top ®TM Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow Revised: June 15, 2015 The Dow Chemical Company Page 2 of 6 Product Safety Assessment: UCAR Propylene Glycol Aircraft Deicing and Anti-Icing Fluids Exposure Potential Based on the uses for ADF and AAF products, the public could be exposed through: 4 • Workplace exposure – Exposure can occur at a manufacturing site. Those working with these products in production facilities could be exposed during maintenance, sampling, testing, or other procedures. Airfield personnel can be exposed during aircraft deicing and anti-icing operations. The potential for exposure is reduced by engineering controls and personal protective equipment. Facilities that manufacture or use these fluids should have a thorough training program for employees and appropriate work processes and safety equipment in place to limit exposure. See Health Information. • Consumer exposure to ADF and AAF products – Dow does not sell these products for consumer use. Under normal conditions of use, airline passengers and flight crews would not be expected to have any significant exposure to these fluids. Any odor detected would be at an exposure level that is considered safe for humans. See Health Information. 4 • Environmental releases – In the event of a spill, the focus is on containing the spill to prevent contamination of soil, ditches, sewers, waterways, or groundwater. For small spills, absorb the material with materials such as cat litter, sawdust, vermiculite, or Zorball. Collect the material in suitable and properly labeled containers. See Environmental, Health, and Physical Hazard Information. • Large release – Industrial spills or releases are infrequent and generally contained. If a large spill does occur, dike the area to contain the spill. Isolate the area and evacuate unnecessary personnel. Recover spilled material if possible. Use appropriate safety equipment. Excessive product accumulation on the tarmac during deicing or anti-icing operations should be 5 removed by mechanical means (e.g., vacuum truck). See Environmental and Physical Hazard Information. • In case of fire – Keep people away and deny unnecessary entry. Firefighters should wear positive-pressure, self-contained breathing apparatus (SCBA) and protective firefighting clothing or fight the fire from a safe distance. Use water fog or fine spray, dry-chemical or carbon-dioxide fire extinguishers, or foam. Do not use a direct water stream as it may spread the fire. Follow emergency procedures carefully. See Health and Physical Hazard Information. For more information, see the relevant Safety Data Sheet. Back to top Health Information4 The primary ingredient in UCAR™ PG ADF and UCAR FlightGuardTM AAF products is propylene glycol (PG), which is “generally recognized as safe” (GRAS) as a food additive by the U.S. Food 13 and Drug Administration (FDA). For more information about PG, refer to the Propylene Glycol Product Safety Assessment and the relevant Safety Data Sheet. Eye and Skin Contact – Eye contact with these ADF and AAF products may cause slight, temporary irritation but is unlikely to result in corneal injury. Prolonged skin contact is essentially nonirritating and is unlikely to result in absorption of harmful amounts. Repeated contact may cause flaking and softening of the skin. Contact with heated fluids may cause thermal burns. Inhalation – At room temperature, exposure to vapor is minimal. Excessive inhalation of heated vapors or mist may cause respiratory irritation or other effects. Ingestion – These products have very low toxicity if swallowed. Harmful effects are not anticipated from swallowing small amounts. Cancer and Birth Defect Information – Similar formulations did not cause cancer in laboratory animals and were not genotoxic or mutagenic in both in vitro and in vivo tests. The major ®TM Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow Revised: June 15, 2015 The Dow Chemical Company Page 3 of 6 Product Safety Assessment: UCAR Propylene Glycol Aircraft Deicing and Anti-Icing Fluids component in these products did not cause birth defects or any other fetal effects, and also did not adversely affect reproduction or fertility in laboratory animals. For more information, see the relevant Safety Data Sheet. Back to top Environmental Information14,15 Propylene glycol, the primary component in these ADF and AAF products, has a low bioconcentration potential (tendency to accumulate in the food chain) and is readily 16 biodegradable. This family of materials is practically nontoxic to fish and other aquatic organisms on an acute basis (large, single exposure). For more information about PG, refer to the Propylene Glycol Product Safety Assessment. For more information, see the relevant Safety Data Sheet. Back to top Physical Hazard Information4,17 UCAR™ PG ADF and UCAR FlightGuardTM AAF products are thermally stable at typical storage and use temperatures. Some components of these products can decompose at elevated temperatures causing pressure build-up in closed systems. Exposure to sunlight will cause the color in these products to fade. Avoid contact with strong acids, strong bases, and strong oxidizers. Areas sprayed with these fluids (such as the tarmac) may become slippery. For more information, see the relevant Safety Data Sheet. Back to top Regulatory Information Regulations may exist that govern the manufacture, sale, transportation, use, and/or disposal of these ADF and AAF products. These regulations may vary by city, state, country, or geographic region. Information may be found by consulting the relevant Safety Data Sheet, Product Information Bulletin, or Contact Us. Back to top Additional Information • • • • • TM Safety Data Sheet (http://www.dow.com/webapps/msds/msdssearch.aspx) Contact Us (http://www.dow.com/aircraft/contact/index.htm) Product Safety Assessment: Propylene Glycol, The Dow Chemical Company, May 2, 2006 (http://www.dow.com/webapps/lit/litorder.asp?filepath=productsafety/pdfs/noreg/233-00248) UCAR FlightGuard AD-49 Propylene Glycol Type IV Aircraft Anti-Icing Fluid, Product Information Bulletin, The Dow Chemical Company, Form No. 180-00078-0913 AMS, September 2013 (http://www.dow.com/PublishedLiterature/dh_007b/0901b8038007ba51.pdf?filepath=aircraft/ pdfs/noreg/183-00043.pdf&fromPage=GetDoc) UCAR PG Aircraft Deicing Fluids, Product Information Bulletin, The Dow Chemical Company, Form No. 183-00024-0704x AMS, July 2004 (http://msdssearch.dow.com/PublishedLiteratureDOWCOM/dh_08ac/0901b803808ac175.pdf ?filepath=aircraft/pdfs/noreg/183-00024.pdf&fromPage=GetDoc) Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow Revised: June 15, 2015 The Dow Chemical Company Page 4 of 6 Product Safety Assessment: UCAR Propylene Glycol Aircraft Deicing and Anti-Icing Fluids • “Thickeners for Aircraft Anti-icing Fluids: Relationship to Performance Properties,” Presentation, The Dow Chemical Company For more business information about UCARTM PG ADF and UCAR FlightGuard AAF products, visit Dow’s Aircraft Deicing and Anti-icing Fluids website at http://www.dow.com/enus/aircraft/products. Back to top References 1 Dow Aircraft Deicing and Anti-icing website: Products (http://www.dow.com/aircraft/products/index.htm). 2 UCAR™ PG Aircraft Deicing Fluids, Product Information Bulletin, The Dow Chemical Company, Form No. 183-00024-0704x AMS, July 2004, page 6. 3 UCAR FlightGuard™ AD-49Propylene Glycol Type IV Aircraft Anti-Icing Fluid, Product Information Bulletin, The Dow Chemical Company, Form No. 180-00078-0913 AMS, September 2013, pages 22–23. 4 UCAR PG Aircraft Deicing Fluid Concentrate Material Safety Data Sheet, The Dow Chemical Company 5 UCAR™ PG Aircraft Deicing Fluids, Product Information Bulletin, The Dow Chemical Company, Form No. 183-00024-0704x AMS, July 2004, page 28. 6 “Propylene Glycols,” Chemical Economics Handbook, SRI International, August 2004, Abstract. 7 UCAR FlightGuard AD-49 Propylene Glycol Type IV Aircraft Anti-Icing Fluid, Product Information Bulletin, The Dow Chemical Company, Form No. 183-00078-0913 AMS, September 2013, pages 6 and 13. 8 Product Safety Assessment: Propylene Glycol, The Dow Chemical Company, May 2, 2006. 9 UCAR PG Aircraft Deicing Fluids, Product Information Bulletin, The Dow Chemical Company, Form No. 183-00024-0704x AMS, July 2004, pages 6 and 29–30. 10 UCAR FlightGuard AD-49Propylene Glycol Type IV Aircraft Anti-Icing Fluid, Product Information Bulletin, The Dow Chemical Company, Form No. 180-00078-0913 AMS, September 2013, pages 10 and 22–25 . 11 “Thickeners for Aircraft Anti-icing Fluids: Relationship to Performance Properties,” Presentation, The Dow Chemical Company. 12 Estimates by The Dow Chemical Company. 13 U.S. Food and Drug Administration GRAS webpage: (http://vm.cfsan.fda.gov/~dms/eafus.html). 14 UCAR™ PG Aircraft Deicing Fluid Concentrate Material Safety Data Sheet, The Dow Chemical Company, pages 4–5. 15 UCAR™ PG Aircraft Deicing Fluids, Product Information Bulletin, The Dow Chemical Company, Form No. 183-00024-0704x AMS, July 2004, pages 20–21. 16 Screening Information Data Set (SIDS) Initial Assessment Report for SIAM 11 – Propylene Glycol: CAS No. 57-55-6, Organisation for Economic Co-operation and Development (OECD),United Nations Environment Programme (UNEP): USA, January 23-26, 2001, page 3. 17 UCAR PG Aircraft Deicing Fluids, Product Information Bulletin, The Dow Chemical Company, Form No. 183-00024-0704x AMS, July 2004, pages 23 and 28. TM Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow Revised: June 15, 2015 The Dow Chemical Company Page 5 of 6 Back to top NOTICES: 1 As part of its 2015 Sustainability Goals, Dow has committed to make publicly available safety assessments for its products globally. This product safety assessment is intended to give general information about the chemical (or categories of chemicals) addressed. It is not intended to provide an in-depth discussion of health and safety information. Additional information is available through the relevant Safety Data Sheet, which should be consulted before use of the chemical. This product safety assessment does not replace required communication documents such as the Safety Data Sheet. The information herein is supplied upon the condition that the persons receiving same will make their own determination as to its suitability for their purposes prior to use. In no event will Dow be responsible for damages of any nature whatsoever resulting from the use of or reliance upon the information herein or the product to which that information refers. Nothing contained herein is to be construed as a recommendation to use any product, process, equipment or formulation in conflict with any patent, and Dow makes no representation or warranty, express or implied, that the use thereof will not infringe any patent. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER NATURE ARE MADE HEREUNDER WITH RESPECT TO INFORMATION OR THE PRODUCT TO WHICH INFORMATION REFERS. Dow makes no commitment to update or correct any information that appears on the Internet or on its World-Wide Web server. The information contained in this document is supplemental to the Internet Disclaimer, http://www.dow.com/en-us/terms-of-use/ Back to top Form No. 233-00458-MM-0615X ®TM Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow Revised: June 15, 2015 The Dow Chemical Company Page 6 of 6