* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Annex C: Bid Submission Forms
Ground loop (electricity) wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Transformer wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Ground (electricity) wikipedia , lookup
Power engineering wikipedia , lookup
Power inverter wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Electrical ballast wikipedia , lookup
Earthing system wikipedia , lookup
Stepper motor wikipedia , lookup
History of electric power transmission wikipedia , lookup
Distribution management system wikipedia , lookup
Electrical substation wikipedia , lookup
Current source wikipedia , lookup
Schmitt trigger wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power MOSFET wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power electronics wikipedia , lookup
Voltage regulator wikipedia , lookup
Opto-isolator wikipedia , lookup
Surge protector wikipedia , lookup
Buck converter wikipedia , lookup
Stray voltage wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Voltage optimisation wikipedia , lookup
IRAQ INVITATION TO BID ITB-090/16 Procurement & Installation of 45MVA 132/33KV Mobile Sub-station - Sinoni District United Nations Development Programme JUNE 2016 Section 4: Bid Submission Form (This should be written in the Letterhead of the Bidder. Except for indicated fields, no changes may be made in this template.) Insert: Location Insert: Date To: Dear Sir/Madam: We, the undersigned, hereby offer to supply the goods and related services required for ITB-090/16 Procurement & Installation of 45MVA 132/33KV Mobile Sub-station - Sinoni District ”” in accordance with your Invitation to Bid dated on 20 January, We are hereby submitting our Bid, which includes the Technical Bid and Price Schedule. We hereby declare that: a) All the information and statements made in this Bid are true and we accept that any misrepresentation contained in it may lead to our disqualification; b) We are currently not on the removed or suspended vendor list of the UN or other such lists of other UN agencies, nor are we associated with, any company or individual appearing on the 1267/1989 list of the UN Security Council; c) We have no outstanding bankruptcy or pending litigation or any legal action that could impair our operation as a going concern; and d) We do not employ, nor anticipate employing, any person who is or was recently employed by the UN or UNDP. We confirm that we have read, understood and hereby fully accept the Schedule of Requirements and Technical Specifications describing the duties and responsibilities required of us in this ITB, and the General Terms and Conditions of UNDP’s Standard Contract for this ITB. We agree to abide by this Bid for One Hundred Twenty (120) days. We undertake, if our Bid is accepted, to initiate the supply of goods and provision of related services not later than the date indicated in the Data Sheet. We fully understand and recognize that UNDP is not bound to accept this Bid that we shall bear all costs associated with its preparation and submission, and that UNDP will in no case be responsible or liable for those costs, regardless of the conduct or outcome of the evaluation. We remain, yours sincerely, Authorized Name and Name of Contact Details: Signature Title [In full of and initials]: Signatory: Firm: Pls. mark this with your corporate seal 5 No deletion or modification may be made in this form. Any such deletion or modification may lead to the rejection of the Bid. 2 Section 5: Documents Establishing the Eligibility and Qualifications of the Bidder Bidder Information Form6 Date: [insert date (as day, month and year] of Bid Submission] ITB No.: [insert number of bidding process] Page ________of ________ pages 1. Bidder’s Legal Name [insert Bidder’s legal name] 2. In case of Joint Venture (JV), legal name of each party: [insert legal name of each party in JV] 3. Actual or intended Country/ies of Registration/Operation: [insert actual or intended Country of Registration] 4. Year of Registration in its Location: [insert Bidder’s year of registration] 5. Countries of Operation 6. No. of staff in each Country 7.Years of Operation in each Country 8. Legal Address/es in Country/ies of Registration/Operation:[insert Bidder’s legal address in country of registration] 9. Value and Description of Top three (3) Biggest Contract for the past five (5) years 10. Latest Credit Rating (Score and Source, if any) 11. Brief description of litigation history (disputes, arbitration, claims, etc.), indicating current status and outcomes, if already resolved. 12. Bidder’s Authorized Representative Information Name: [insert Authorized Representative’s name] Address: [insert Authorized Representative’s Address] Telephone/Fax numbers: [insert Authorized Representative’s telephone/fax numbers] Email Address: [insert Authorized Representative’s email address] 13. Are you in the UNPD List 1267.1989 or UN Ineligibility List? ☐ YES or ☐ NO 14. Attached are copies of original documents of: □ All eligibility document requirements listed in the Data Sheet □ If Joint Venture/Consortium – copy of the Memorandum of Understanding/Agreement or Letter of Intent to form a JV/Consortium, or Registration of JV/Consortium, if registered □ If case of Government corporation or Government-owned/controlled entity, documents Establishing legal and financial autonomy and compliance with commercial law. 6 The Bidder shall fill in this Form in accordance with the instructions. Apart from providing 3 additional information, no alterations to its format shall be permitted and no substitutions shall be accepted. 4 Joint Venture Partner Information Form (if Registered) 7 Date: [insert date (as day, month and year) of Bid Submission] ITB No.: [insert number of bidding process] Page ________ of ________ pages 1. Bidder’s Legal Name: [insert Bidder’s legal name] 2. JV’s Party legal name: [insert JV’s Party legal name] 3. JV’s Party Country of Registration: [insert JV’s Party country of registration] 4. Year of Registration: [insert Party’s year of registration] 5. Countries of Operation 6. No. of staff in each Country 7.Years of Operation in each Country 8. Legal Address/es in Country/ies of Registration/Operation: [insert Party’s legal address in country of registration] 9. Value and Description of Top three (3) Biggest Contract for the past five (5) years 10. Latest Credit Rating (if any): Click here to enter text. 1. Brief description of litigation history (disputes, arbitration, claims, etc.), indicating current status and outcomes, if already resolved. Click here to enter text. 13. JV’s Party Authorized Representative Information Name: [insert name of JV’s Party authorized representative] Address: [insert address of JV’s Party authorized representative] Telephone/Fax numbers: [insert telephone/fax numbers of JV’s Party authorized representative] Email Address: [insert email address of JV’s Party authorized representative] 14. Attached are copies of original documents of: [check the box(es) of the attached original documents] □ All eligibility document requirements listed in the Data Sheet □ Articles of Incorporation or Registration of firm named in 2. □ In case of government owned entity, documents establishing legal and financial autonomy and compliance with commercial law. 7 The Bidder shall fill in this Form in accordance with the instructions. Apart from providing additional information, no alterations to its format shall be permitted and no substitutions shall be accepted. 5 Section 6: Technical Bid Form ITB-090/16 Procurement & Installation of 45MVA 132/33KV Mobile Sub-station Sinoni District Name of Bidding Organization / Firm: Country of Registration: Name of Contact Person for this Bid: Address: Phone / Fax: Email: SECTION 1: EXPERTISE OF FIRM/ ORGANISATION This section should fully explain the Bidder’s resources in terms of personnel and facilities necessary for the performance of this requirement. 1.1 Brief Description of Bidder as an Entity: Provide a brief description of the organization / firm submitting the Bid, its legal mandates/authorized business activities, the year and country of incorporation, and approximate annual budget, etc. Include reference to reputation, or any history of litigation and arbitration in which the organization / firm has been involved that could adversely affect or impact the delivery of goods and/or performance of related services, indicating the status/result of such litigation/arbitration. 1.2. Financial Capacity: Based on the latest Audited Financial Statement (Income Statement and Balance Sheet) describe the financial capacity (liquidity, stand-by credit lines, etc.) of the bidder to engage into the contract. Include any indication of credit rating, industry rating, etc. 1.3. Track Record and Experiences: Provide the following information regarding corporate experience within at least the last five (5) years which are related or relevant to those required for this Contract. Name of project Client Contract Value Please fill Please fill Please fill here here here Period of activity Types of activities undertaken Status or Date Completed Please fill Please fill here Please fill here here References Contact Details (Name, Phone, Email) Please fill here 8 Technical Bids not submitted in this format may be rejected. 6 SECTION 2 - S C O P E OF SUPPLY, TECHNICAL SPECIFICATIONS, AND RELATED SERVICES This section should demonstrate the Bidder’s responsiveness to the specification by identifying the specific components proposed, addressing the requirements, as specified, point by point; providing a detailed description of the essential performance characteristics proposed; and demonstrating how the proposed bid meets or exceeds the specifications. 2.1. Scope of Supply: Please provide a detailed description of the goods to be supplied, indicating clearly how they comply with the technical specifications required by the ITB (see below table); describe how the organization/firm will supply the goods and any related services, keeping in mind the appropriateness to local conditions and project environment. Ite m No Description/ Specification of Goods Source/ Manufacturer Please fill here Please fill here Country of Origin Qty. Please fill Please here fill here A supporting document with full details may be annexed to this section Quality Certificate/ Export Licenses, etc. (indicate all that applies and if Please fill here attached) 2.2. Technical Quality Assurance Mechanisms: The bid shall also include details of the Bidder’s internal technical and quality assurance review mechanisms, all the appropriate quality certificates, export licenses and other documents attesting to the superiority of the quality of the goods and technologies to be supplied. 2.3. Reporting and Monitoring: Please provide a brief description of the mechanisms proposed for this project for reporting to the UNDP and partners, including a reporting schedule. 2.4. Subcontracting: Explain whether any work would be subcontracted, to whom, how much percentage of the work, the rationale for such, and the roles of the proposed sub-contractors. Special attention should be given to providing a clear picture of the role of each entity and how everyone will function as a team. 2.5. Risks / Mitigation Measures: Please describe the potential risks for the implementation of this project that may impact achievement and timely completion of expected results as well as their quality. Describe measures that will be put in place to mitigate these risks. 2.6 Implementation Timelines: The Bidder shall submit a Gantt chart or P r o j e c t S c h e d u l e indicating the detailed sequence of activities that will be undertaken and their corresponding timing. 2.7. Partnerships (Optional): Explain any partnerships with l o c a l , i n t e r n a t i o n a l o r o t h e r organizations that are planned for the implementation of the project. Special attention should be given to providing a clear picture of the role of each entity and how everyone will function as a team. Letters of commitment from partners and an indication of whether some or all have successfully worked together on other previous projects is encouraged. 7 2.8. Anti-Corruption Strategy (Optional): Define the anti-corruption strategy that will be applied in this project to prevent the misuse of funds. Describe the financial controls that will be put in place. 2.9 Statement of Full Disclosure: This is intended to disclose any potential conflict in accordance with the definition of “conflict” under Section 4 of this document, if any. 2.10 Other: Any other comments or information regarding the bid and its implementation. 8 SECTION 3: PERSONNEL 3.1 Management Structure: Describe the overall management approach toward planning and implementing the contract. Include an organization chart for the management of the contract, if awarded. 3.2 Staff Time Allocation: Provide a spreadsheet will be included to show the activities of each personnel involved in the implementation of the contract. Where the expertise of the personnel is critical to the success of the contract, UNDP will not allow substitution of personnel whose qualifications had been reviewed and accepted during the bid evaluation. (If substitution of such a personnel is unavoidable, substitution or replacement will be subject to the approval of UNDP. No increase in costs will be considered as a result of any substitution). 3.3 Qualifications of Key Personnel. Provide the CVs for key personnel (Team Leader, Managerial and general staff) that will be provided to support the implementation of this project. CVs should demonstrate qualifications in area of expertise relevant to the Contract. Name:use the format below: Please Role in Contract Implementation: Nationality: Contact information: Countries of Relevant Work Experience: Language Skills: Education and other Qualifications: Summary of Experience: Highlight experience in the region and on similar projects. Relevant Experience (From most recent): Period: From – To Name of activity/ Job Title and Activities Project/ funding undertaken/Description organization, if of actual role performed: applicable: e.g. Etc. Etc. References (minimum of 3): Name Designation Organization Contact Information – Address; Phone; Email; etc. Declaration: I confirm my intention to serve in the stated position and present availability to serve for the term of the proposed contract. I also understand that any willful misstatement described above may lead to my disqualification, before or during my engagement. _________________________________________________ __________________________ Signature of the Nominated Team Leader/Member Date Signed BREAKDOWN OF PRICES Important Note: The rates shall be used for the price analyses and evaluation purposes or any other requirements and shall be fixed and firm for the duration of the contract and shall be inclusive of all facilities, office running cost, communication, transportation, company overheads .etc. Description Lump Sum Amount US$ ITB-090/16 Procurement & Installation of 45MVA 132/33KV Mobile Sub-station - Sinoni District Equipment conform to the required specifications agreed: Yes No Completion Period: 5 months upon PO issuance agreed: Yes No Guarantee Period for the offered Equipment: One Year, agreed Yes No Company Stamp and Signature: ------------------------------------------------------- Official E-mails of the Company: ------------------------------------------------------- Date: ------------------------------------ Section 7: Price Schedule Form Annex (A) ITB-090/16 Procurement & Installation of 45MVA 132/33KV Mobile Sub-station - Sinoni District No. 1 Items Description Supply and Install of 45 MVA mobile substation 132 ± 10% / 33 K.V according to attached MOE technical specifications Rated power 45 MVA Rated frequency 50 Hz Vector group YNd1 On-load tap changer with 17 taps and automatic voltage regulator 75 KVA auxiliary and earthing transformer (33 / 0.4-0.22) K.V 300 A Highest system voltage 145 K.V / 36 K.V Power frequency withstand test voltage (for 1 min): 132 K.V System 33 K.V System for bushing 275 K.V 70 K.V for winding 230 K.V 70 K.V for neutral 140 K.V 70 K.V Disconnecting switch 145 K.V , 630 A , 31.5 KA with Earthing switch of 31.5 KA / 3 sec Vacuum Circuit breaker 145 K.V , 630 A , 31.5 KA with motor charged spring operation Vacuum Circuit breaker 36 K.V , 630 A , 31.5 KA Bushing type Current Transformer mounted on primary bushing of power transformer 150/ 5-5-5 A class X/1.0/5P10 , 15 VA 5 Panels of outgoing feeder rated current 630 A, breaking current 31.5 KA Rated voltage for lighting arresters : 132 K.V System 3 K.V System on phase 120 KV / 10 KA 39 KV / 10 KA on neutral 75 KV / 10 KA 21 KV / 10 KA Ambient Temperature 55 C⁰ More technical details in attached Annex of MoE general specification and technical requirements 2 Spare Parts Unit Quantity Ea. 1 Unit Price USD No. 2-A Items Description Lighting Arrester 120 K.V Unit Quantity Ea. 3 Ea. 2 Ea. 1 Rated voltage 120 K.V rms Rated frequency 50 Hz Nominal discharge current , heavy duty 10 Ka erest Max. continuous operating voltage 93.6 K.V rms with surge counter and recorder More technical details in attached Annex of MoE general specification and technical requirements 2-B Indoor type 36 K.V Vacuum Circuit breaker Triple-pole, motor-charged spring operated Rated voltage 36 K.V Impulse withstand voltage 170 K.V (peak) Rated frequency 50 Hz Rated normal current 630 A Rated short circuit current 31.5 A Standard operating duty 0-0.3 sec - CO- 3 min – CO Rated motor operating voltage DC 110 V More technical details in attached Annex of MoE general specification and technical requirements 2-C Outdoor type 145 K.V Vacuum Circuit breaker Triple-pole, motor-charged spring operated Rated voltage 145 K.V Impulse withstand voltage 650 K.V (peak) Rated frequency 50 Hz Rated normal current 630 A Rated short circuit current 31.5 A Standard operating duty 0-0.3 sec - CO- 3 min – CO Rated motor operating voltage DC 110 V Rated closing control voltage DC 110 V Rated tripping control voltage DC 110 V More technical details in attached Annex of MoE general specification and technical requirements Unit Price USD No. Items Description Unit Quantity 2-D Manual operating handle (For each disconnector and Earthing switch and circuit breaker charging) Set 1 2-E No - voltage trip coil for 145 KV circuit breaker Ea. 2 2-F On - coil 145 KV circuit breaker Ea. 2 2-G Off- coil 145 KV circuit breaker Ea. 2 2-H 2-I On - coil 36 KV circuit breaker Off- coil 36 KV circuit breaker More technical details in attached Annex of MoE general specification and technical requirements Ea. Ea. 5 10 3 Site Preparations Supply materials, tools, manpower and machinery for earth cleaning works and then embankment using suitable sub base (Mountain Tekala) layers 30cm with good compaction for substation location area 50 x 20 m using suitable equipment and machinery. Supply materials, tools, manpower and machinery for installation of a rounded BRC fence using 5cm wire clip or BRC 2m height supported with galvanize tubes 2.5 in each 3m with supporting wires 3 and 3 pared wires best quality according to Iraq specifications. The price includes installation of new BRC doors 2m*5m with supporting columns according to Iraqi specifications. M2 1,000 ML 140 3-A 3-B Unit Price USD Sub-total Cost in US Dollars Ref: 1 2 3 4 Notices: Refer to attached Annex B: MOE General Technical Requirements for 45MVA 132/33kV mobile substation. The vendor will be responsible for provision and installation works of substation with complete MoE representative’s approvals and not included Installation works. Supplied Substation and materials should be compliant with Iraqi MoE standards and specifications and pass the necessary required tests. The supplied substation specifications and list of substation components should be approved by MoE engineering committee before starting with manufacturing process 7 The supplier should submit Substation single line diagram to the authorized MoE committee for approval before starting the manufacturing process. The Supplier should responsible to conduct factory Inspection for MoE authorized committee before starting with shipping process Materials and Equipment should be brand new and never used before & registered with Ninawa Electricity Directorate 8 Given price Must be VAT exclusive. UNDP will provide the exemption Certificate. The bidder has to provide the shipping 5 6 No. Items Description Unit Quantity Unit Price USD documents in advance. The shipment should be in the name of Resident Representative, UNDP SCHEDULE OF REQUIREMENTS Annex (AA) ITB-090/16 Procurement & Installation of 45MVA 132/33KV Mobile Sub-station - Sinoni District TECHNICAL COMPLIANCE SHEET 45MVA mobile substation The following Technical data shall be furnished and filled by the bidder: 1-General UNDP specifications Bidders’ Offered specifications Ambient temperature : Maximum:55/C Minimum:-10/C Relative Humidity : around 60% at maximum temperature Altitude: 1000M above MSL System Voltage : 132/33KV No of phase : 3PH Frequency: 50Hz Make: Original manufacturer (Local Assembled Not acceptable) Type: ABB, Schneider, Siemens or equivalent 1-a 132KV system UNDP specifications Bidders’ Offered specifications Norma Voltage : 132 K Volt Highest system voltage :145 K Volt System : 3Ph , 3wire , 50Hz Short circuit level : 25KA r.m.s at 33000 volts Impulse with stand voltage For bushing : 275 KV For winding : 230 KV For Neutral : 140KV Rated breaking capacity : 31.5 KA Short time Current :31.5KA /1sec Rated voltage and nominal discharge current of lightning Arresters On phase : 120KV/10KA On neutral: 75KV /10KA Minimum clearance in air between phase and earth: 1,270 mm Minimum clearance in air between different phases: 1473mm Minimum creepage distance of insulator and bushing:4,495 mm Earthing system: Effectively earthed neutral 1-b) 33KV system UNDP specifications Norma Voltage : 33KV Highest system voltage :36 KVolt Bidders’ Offered specifications System: 3Ph. 3wire ,50Hz Short circuit level : 25KA r.m.s at 11000 volts Impulse with stand voltage For bushing : 70 KV For winding : 70 KV For Neutral : 70KV Rated breaking capacity : 31.5 KA Short time Current :31.5KA /1sec Rated voltage and nominal discharge current of lightning Arresters On phase : 39KV/10KA On neutral: 21KV /10KA Minimum clearance in air between phase and earth: 320 mm (*2)(air cable box) Minimum clearance in air between different phases: 320 mm (*2)(air cable box) Minimum creepage distance of insulator and bushing: 576 mm (air cable box) Earthing system: Earthed through earthing TF (300A) 1-c) Axillary AC and DC system UNDP specifications AC : 380/220 3Ph , 4wire ,with natural solidly earthed DC : 110 2 wire Bidders’ Offered specifications 2- Lighting Arrester for 132 KV and 33 KV Bidders’ Offered specifications UNDP specifications 1- Make: ABB, Schneider, Siemens or equivalent 132KV Line 2-a Rated voltage : 120 kv Nominal discharge 10 kA current : (peak value) Line discharge class : 3 132KV neutral 33kv Line 33kv natural 75 KV 39 21KV 10 kA (peak value) 10 kA (peak value) 10 kA (peak value)10 3 2 2 132KV Line 132KV neutral 33kv Line 3- Submit Manufacturer certification : 4- Submit Detail drawing brochure catalogue : 3-145 kV Disconnecting Switch and Earthing Switch No Description UNDP specifications 1- Make: ABB, Schneider, Siemens or equivalent 2- Type: a) Disconnecting switch Air-insulated, Vertical, single throw, manual operation type Ditto b) Earthing switch Bidders’ specifications Offered 33kv natur al 345- Number of poles Location of service Rated voltage 3 Outdoor 145KV 6- Rated insulation level a) Impulse withstand voltage b) One minute 50 Hz withstand voltage (r.m.s.) Space between open contacts a) Distance b) Impulse withstand voltage (peak) 650KV 7- 8No 9110- 11- 1213- 275KV 1400 mm 750 kV c) One minutes withstand 50 Hz 315 kV voltage (r.m.s.) 1250A Rated normal current Description UNDP specifications Rated short-timer current at time 31.5 kA duration of 1sec.for main contacts and ABB, Schneider, Siemens or Make: earthing switch equivalent Cree page path 2200 mm a) Protected b) Total 4495 mm Minimum Clearance in air 1700 mm a) Between poles `b) To earth 1350 mm Type of operating mechanism Manual Type of interlocking mechanism a) Interlocked with CB Electrical b) Interlocked with earthing switch Mechanical with pad lock 14- Rated supply voltage for a) Interlocking mechanism b) Thermostat c) Heater 15 Number and type of spare auxiliary Switches 16- Auxiliary switch a) Continuous current carrying capacity b) Breaking capacity at 110V DC 17- Type of corrosion protection of steel parts 18- Certificate or report of type test 22- Submit Manufacturer certification : 23- Submit Detail drawing brochure catalogue: 24 Submit certification or report of type test 414 5 kV Ci rc uit Br ea ke rs: DC 110 V AC 220 V AC 220 V 5 NO / 5NC 10 A or more 4 A or more Hot dipped Galvanized Bidders’ specifications Offered 2- Type: 345- Number of poles Class: indoor or outdoor Rated voltage 3 Outdoor 145KV 6- Rated insulation level c) Impulse withstand voltage d) One minute 50 Hz withstand voltage (r.m.s.) Rated Frequency Rated normal current Rated breaking current Line charging duration of 1sec.for main contacts and earthing switch Rated small inductive breaking current Rated Short-circuit breaking current a) Symmetrical b) D. C. component Less than Rated short-timer current at time duration of 1sec. Type of operating mechanism Rated supply voltage for a) Closing coil 650KV 789- 1011- 121314- b) Shunt opening release c) Motor d) Thermostat e) Heater 15- Current required at rated supply voltage by a) Closing coil b) Shunt opening release 5 A c) Motor d) Heater 16- Auxiliary switch a) Continuous current carrying capacity b) Breaking capacity at 110V DC Air-insulated, motor charged spring, triple pole operation Vacuum Circuit Breaker or SF6 275KV 50Hz 630A 50 A 5A 31.5 kA 45% 31.5 kA Motor spring DC 110 V DC 110 V DC 110 V AC 220 V AC 220 V 3.1A 3.1A 10 A To be filled in A 10 A or more 4A 17- Number and type of spare 8NO / 8 NC auxiliary Switches 18- Creepage path Total 19- Guaranteed number of 20 21 operations with no load before being necessary to inspect the circuit breaker poles & operating device Type of corrosion protection of steel parts Certificate or report of type test 4495 mm 10000 Zinc hot dip and galvanized painting To be filled in 22- Submit Manufacturer certification : 23- Submit Detail drawing brochure catalogue : 24- Submit certification or report of type test 5-36 kV Circuit Breakers No Description UNDP specifications 1- Make: ABB, Schneider, Siemens or equivalent 2- Type: Air-insulated, motor charged spring, triple pole operation Vacuum Circuit Breaker Number of poles Class: indoor or outdoor Rated voltage Rated insulation level a) Impulse withstand voltage b) One minute 50 Hz withstand voltage (r.m.s.) 7- Rated Frequency 8- Rated normal current 9- Rated breaking current Line charging 10- Rated Short-circuit breaking current a) Symmetrical b) D. C. component Less than 11- Rated short-timer current at time duration of 1sec. 12- Type of operating mechanism 3456- 13- C. B. is trip-free or with lock-out 3 Indoor 36KV 170KV 70KV 50Hz 630A 10A 31.5 kA Less than 20% 31.5 kA Motor spring Trip free preventing 14- Rated supply voltage for c) Closing coil b) Shunt opening release c) Motor DC 110 V DC 110 V DC 110 V Bidders’ Offered specifications 15- Current required at rated supply voltage by a) Closing coil b) Shunt opening release 5A 7A c) Motor 5A 645 M VA 13 2/3 3 kV Ma in Tr ans for me r 16- Auxiliary switch a) Continuous current carrying capacity b) Breaking capacity at 110V DC 3A 3A 5NO /5 NC 17- Number and type of spare auxiliary Switches 18- Creepage path Total 4495 mm 10000 19- Guaranteed number of operations with no load before being necessary to inspect the circuit breaker poles & operating device 20- Type of corrosion protection of steel parts 21- Certificate or report of type test Zinc chromate plating and painting To be filled in 22- Submit Manufacturer certification : No Description UNDP specifications 23 Submit Detail drawing brochure Licensed from Iraq MOE 1- catalogue Make: : 24Submit test 2Type: certification or report of typeOil-immersed, ODAF cooling with on-load tap-changer and AVR Relay in indoor selfstanding Panel 345- Number of poles Class: indoor or outdoor Rated voltage Ratio 6- Rated power 7- Rated Frequency Rated voltage b) H.V. 8- 3 Outdoor 132/33KV 45MVA 50Hz 132 +/- 10% kV (17 taps, 1.25% step) 9- 10-1 10-2 b) L.V. Rated voltage of winding a) H.V. b) L.V. Insulation level : Impulse withstand voltage a) H.V line b) H.V neutral c) LV Insulation level : One minute 50 Hz withstand voltage 33 kV 132 kV 33 kV Winding 550 KV 325 KV 170KV Bushing 650 KV 325 KV 170KV Bidders’ specifications Offered 11- 12- 1314- 15- 16- 171819- 20- 21- 22- 23- a) H.V. line b) H.V natural c) L.V Winding temperature at rated power a) Rise b) Total Top oil temperature at rated power a) Rise b) Total Calculated thermal time constant Maximum flux density in iron at rated frequency and rated voltage ratio a) at normal voltage b) at 90% normal voltage c) at 110% normal voltage Maximum current density in windings at rated power a) H.V. winding b) L.V. winding Losses a) No load loss at rated voltage and frequency b) Load loss at rated power and 75 _C Power required for cooling plant Impedance voltage at rated power for H.V. -L.V. winding Type of winding a) H.V. b) L.V. Type of insulation of winding a) H.V. b) L.V. Kraft paper Type of insulation of a) Tapping b) Tapping connections c) Core assembly d) Core laminations Thickness of transformer tank a) Sides b) Bottom Winding connection a) H.V. b) L.V 230KV 140KV 70KV 275KV 140KV 70KV 55 _C 110 _C 45-C 100-C 1.0 Hr To be filled in Tesla Tesla Tesla 4.5 A/mm2 4.5 A/mm2 19.39 kW 170 kW To be filled in kW 12% Disc Disc Kraft paper Kraft paper Kraft paper Kraft paper Pressboard and Kraft paper Inorganic coating 9 mm 12 mm Star (neutral brought out) Delta 24- Vector group symbol 25- Cree page path of bushings a) 132 kV line bushings - Protected (90 deg. Shadow) - Total b) 132 kV neutral bushings - Protected (90 deg. Shadow) - Total c) 33 kV bushings Total Secondary cables Number and type of cables Test pressure of oil leak test of tank Type of oil 26272829 30- 3132- 33- Coolers: a) Number of unit coolers per transformer b) Number of oil pumps per transformer c) Number of air blowers per transformer d) Input rating of each blower motor - Oil pump - Air blower Type of corrosion protection on steel parts a) Inside tank b) Outside tank Total oil required Volume Noise level at 3 meter, rated voltage, rated frequency, at noload and with cooling unit operation Bushing a) Standard b)Porcelain color c) Type of bushing - H.V. line and neutral - L.V. d) Rated current - H.V. line and neutral - L.V. 25- Certificate or report of type test 26- Submit Manufacturer certification : Submit Detail drawing brochure catalogue : 27- YNd1 1830 mm 4495 mm ` 880 mm 2248 mm 850 mm 3x1corex500mm2, XLPE, Cu stranded 34 kpa IEC60296 class 1 Blendable with Shell Diala B 2 2 To be filled 2.5KW/unit 1.5KW/unit Oil resistance paint Alkyd resin paint To be filled in m3 80dB (A) IEC 60137 Brown Oil impregnated Paper Solid 1250 A for line 800 A for neutral To be filled in 7-100kVA 33/0.38 kV Auxiliary and Earthling Transformer: No Description 1Make: UNDP specifications ABB, Schneider, Siemens or equivalent 2- Type: 345- Number of poles Class: indoor or outdoor Rated voltage Ratio 3 Outdoor 33/0.38KV 6- Rated power - Continuous 100 kVA 78- 9- - 10 sec. (primary ) Rated Frequency Rated voltage of winding a) H.V. b) L.V Insulation level a) H.V. line b) H.V. neutral 10- 11. 1213- 14- 15- c) L.V. line d) L.V. neutral Winding temperature at rated power a) Rise b) Total Top oil temperature at rated power a) Rise b) Total Calculated thermal time constant Maximum flux density in iron at rated Frequency and at rated voltage ratio a) at normal voltage b) at 90% normal voltage Tesla c) at 110% normal voltage Maximum current density in windings at rated power a) H.V. winding (5720 kVA) b) L.V. winding ( 75 kVA) Zero sequence impedance Oil-immersed with conservator ONAN cooling 5720 kVA 50Hz 33 kV . 0.38Y / 0.22 kV Lightning AC power Impulse frequency 170 kV 125 kV 70 kV 50 kV NA N.A. 3 kV 3 kV 50 C 105 C 45 C 100 C 1.5 Hr To be filled in Tesla Tesla 35 A/mm2 3 A/mm2 195 ohm/phase Bidders’ Offered specifications 161718- 19- 20- 21- 2223- No load current at rated voltage Impedance voltage at continuous rated power Type of winding a) H.V. b) L.V. Type of insulation of winding a) H.V. b) L.V. Type of insulation of a)core assembly b) Core laminations Thickness of transformer tank a) sides b) bottom Thickness of radiator plates and for cooling tube Winding connection a) H.V. b) L.V. 3.2 % 3.6 % Layer Layer Kraft paper Kraft paper Pressboard and Kraft paper Inorganic coating 5 mm 5 mm To be filled in mm Zig-zag (Neutral brought out) Star (Neutral brought out) 24- Vector group symbol Znyn1 25- 34 kpa 26 Test pressure of oil leak test of tank Type of core 27- Type of oil 28- Core sheet materials 29- Type of corrosion protection on steel parts a) Inside tank b) Outside tank 303132- cor IEC60296 class 1 Blend able with Shell Diala B Cold –rolled –grain oriented steel Oil resistant paint Alkyd resin Submit Manufacturer certification : Submit certification or report of type test Submit Detail drawing brochure catalogue : 8- 145 kV Current Transformers No. Description 1- Make 2- Type UNDP specifications ABB, Schneider, Siemens or equivalent Oil-immersed bushing type Bidders’ Offered specifications Rated voltage Rated primary current Rated secondary current Rated short time thermal current Rated dynamic current Rated insulation level b) One minute 50Hz withstand voltage r.m.s.) 9- Characteristics of Current Transformer 10- Line Current Transformer 1) Protection winding-1 on phase bushing a) Accuracy class b) Rated output or Knee-point voltage 345678- 2) Measuring winding on phase bushing a) Accuracy class b) Rated output 3) Protection winding-2 on phase bushing a) Accuracy class b) Rated output 0.72 kV 200 A 5A 31.5 kA 80 kA peak 3kV X Not less than 80 V 1.0 15 VA 5P10 15 VA 11- Neutral Current Transformer Protection winding on neutral bushing a) Accuracy class b) Rated output or Knee-point voltage X Not less than 80 V 12- Submit Manufacturer certification : 13- Submit Single line diagram : 14- Submit Detail drawing brochure catalogue : 9- 36 kV Current Transformers: No. Description UNDP specifications 1- Make ABB, Schneider, Siemens or equivalent 234- Type Rated voltage Rated primary current Incomer Feeder Rated secondary current Rated short time thermal current Rated dynamic current Rated insulation level a) One minute 50Hz withstand voltage(peak) b) One minute 50Hz withstand voltage r.m.s.) Molded and bushing type 36 kV 5678- 600-300A 600-300A 5A 31.5 kA 80 kA peak 170kV 70KV Bidders’ Offered specifications 910-1 Characteristics of Current Transformer Line Current Transformer for incomer 1) Measuring winding a) Accuracy class b) Rated output or Knee-point voltage 1 15VA 2) Protection winding-2 on phase bushing a) Accuracy class b) Rated output c) knee –point voltage 10-2 10-3 X To be filed Not less than 50 Line Current Transformer for Feeder 1) Measuring winding a) Accuracy class b) Rated output or Knee-point voltage 1 7.5KV 2) Protection winding-2 on phase bushing a) Accuracy class b) Rated output c) knee –point voltage 5P10 7.5VA Neutral Current Transformer Protection winding( on neutral point of Aux &Earthing transformer ) a) Accuracy class b) Rated output or Knee-point voltage X Not less than 65V 12- Submit Manufacturer certification : 13- Submit Single line diagram : 14- Submit Detail drawing brochure catalogue : 10- 36 kV Voltage Transformers No. Description 1Make 2- Type 34567- Rated primary voltage Rated Secondary voltage Rated Residual voltage Rated voltage factor Rated insulation level a) One minute 50Hz withstand voltage(peak) b) One minute 50Hz withstand voltage r.m.s.) Accuracy class Rated output 89- UNDP specifications ABB, Schneider, Siemens or equivalent Molded type with residual winding 33 kV /√3 110V/ √3 110V /3 1.2continuse 1.9 for 8hour 170kV 70KV 1.0/3P 100/100VA Bidders’ Offered specifications 11-132 kV Lightning Arrester No Description 132 KV Line Required Bidders’ Offer 132KV neutral Proposed Bidders’ Offer 1- Make: ABB, Schneider, Siemens or equivalent ABB, Schneider, Siemens or equivalent 2- Type : 34567- Rated Voltage : Rated frequency Material of arrester element Normal discharge current (crest) Max. Residual voltage (at 10 kA crest with 8/20 microseconds wave shape) Long duration discharge class Pressure relief current (r.m.s.) Energy absorption Rated insulation level on the assembled insulators a) Impulse withstand voltage (peak) b) One minute 50Hz withstand voltage (r.m.s.) Type of corrosion protection of steel parts Material of insulator Metal oxide gapless 120 KV 50 Hz Zinc oxide 10 kA 294 kV crest Metal oxide gapless 75 KV 50 Hz Zinc oxide 10 kA 184 kV crest 891011- 12131415- Class 3 40 kA 7.5 kJ/kV Class 3 40 kA 7.5 kJ/kV 650 k v 275 kV 325 kV 140 kV Hot-dipped galvanized Porcelain Hot-dipped galvanized Porcelain Submit Manufacturer certification : Submit Detail drawing brochure catalogue 12-33 kV Lightning Arrester: No Description 33KV Line Required Bidders’ Offer 33KV neutral Required 1- Make: ABB, Schneider, Siemens or equivalent ABB, Schneider, Siemens or equivalent 2- Type : 34567- Rated Voltage : Rated frequency Material of arrester element Normal discharge current (crest) Max. Residual voltage (at 10 kA crest with 8/20 microseconds wave shape) Long duration discharge class Pressure relief current (r.m.s.) Metal oxide Silicon type 39KV 50 Hz Zinc oxide 10 kA 107kV crest Metal oxide gapless 21 KV 50 Hz Zinc oxide 10 kA 58 kV crest 89- Class 2 20 kA Class 2 40 kA Bidders’ Offer 1011- 12131415- Energy absorption Rated insulation level on the assembled insulators a) Impulse withstand voltage (peak) b) One minute 50Hz withstand voltage (r.m.s.) Material of insulator Color of insulator 5.5 kJ/kV 4.5 kJ/kV 170 k v 125 kV 63 kV 50 kV Silicon Wight Porcelain Brown Submit Manufacturer certification : Submit Detail drawing brochure catalogue 13-132 kV Bushing: No Description 33KV Line Required Bidders’ Offer 33KV neutral Required Bidders’ Offer 1- Make: ABB, Schneider, Siemens or equivalent ABB, Schneider, Siemens or equivalent 2- Type : 34556- Rated Voltage : Rated current : Rated short time current Rated frequency Rated insulation level on the assembled insulators a) Impulse withstand voltage (peak) b) One minute 50Hz withstand voltage (r.m.s.) Material of insulator Color of insulator Oil-filled condenser type 145KV 1250 A 31.5KA 50 Hz Oil-filled condenser type 72.5 KV 800 A 31.5KA 50 Hz 650k v 275 kV 325 kV 140 kV Porcelain Brown Porcelain Brown 78910- Submit Manufacturer certification : Submit Detail drawing brochure catalogue 14-36kV Medium Voltage Metal Clad Switchgear: No 1- Description Make: UNDP required specifications ABB, Schneider, Siemens or equivalent 2- Type : 345- Rated Voltage : Rated normal current : Rated frequency Air-insulated metal clad type 36KV 630A 50Hz Bidders’ Offered specification 6- 78- 910111213 141516- Rated insulation level on the assembled insulators a) Impulse withstand voltage (peak) b) One minute 50Hz withstand voltage (r.m.s.) Insulation type of busbars 170KV 70KV Covered with Silicone rubber tube Degree of protection a) Enclosure b) Partition Color and type of painting IP42 IP2X Light gray finish, Semi-gloss, Melamine resin Yes ,AC 220V Yes, AC 220 V Yes, with filter Single bus bar Thermostat, Heater Ventilation Bus bars system Submit Manufacturer certification : Submit Detail drawing brochure catalogue Certificate or report of type test 15-Battery No 12- Description Make: Type of Battery panel 3456- Location of service : Type of battery Rated capacity for 5 hours Nominal discharge current for 5 hours Rated voltage of battery Nominal voltage of battery cell Number of cells Final discharge-end voltage Type of electrolyte Type of positive plate 78910111213141516- Type of negative plate Type of Separator Type of container Type of mounting rack . 1718- UNDP required specifications To be filled in Air-insulated metal enclosed type Indoor Pocket-plate Ni-Cd 60 AH/5hr 12 A 110.4 V 1.2 V/cell 92 1.06V/cell Potassium hydroxide Nickel-hydroxide and graphite Electrolytic cadmium Polypropylene fibrous Transparent synthetic resin Steel painted with alkaline resistant paint Submit Manufacturer certification : Certificate or report of type test Bidders’ Offered specification 16- Battery Charger Bidders’ Offered specification No Description UNDP required specifications 12- Make: Type of Battery panel To be filled in Air-insulated metal enclosed type 34- Location of service : Type of battery charger 567- AC input voltage Number of phase of AC input Type of rectifier 89- Type of cooling for rectifier Output constant voltage range of rectifier a) On trickle charge b) On boost charge Regulated voltage range on DC bus bar Means of regulating output voltage on DC bus bar Continuous output current range of battery charger a) On trickle charge b) On boost charge at half maximum rate c) On boost charge at full maximum rate Die-electric strength (50Hz for one minute) a) Between AC phases and earth b) Between AC and DC circuit Setting range of DC under-voltage relay Setting current range of DC earth fault relay Indoor Full automatic constant voltage DC power source 380V 3 Three phase Thirstier full wave bridge Self-air-cooled by metallic fins 101112- 13- 14151617- 131.5 V 133.4V/151.8V 110+- 10% Semi-conductor dropper 20 A 10 A 20 A 2000 V 2000 V 85-95 V Not less than 10 mA Submit Manufacturer certification : Certificate or report of type test 17-Meters for 132 kV side No Description UNDP required specifications 1- Make: ABB, Schneider, Siemens or equivalent 233- Type : Kind of measurement Rated Current : Digital type with LCD monitor AC Current 5A Bidders’ Offered specification No Description UNDP required specifications 5678- Input consumption Accuracy class Number of phase Display of phase current 910- Display updating time. Overload capacity 1112141516- Auxiliary power supply Auxiliary power consumption Less than 0.1 VA 1.0 current input 3 (R,Y,B) Digital quantity of all 3 phase currents in one display 1.0 sec 40 times rated current for 1 sec., 1.2 times for continuous operation DC110 V 5W Bidders’ Offered specification Submit Manufacturer certification : Submit Detail drawing brochure catalogue Certificate or report of type test 18-Meters for MV Incoming: No Description UNDP required specifications 123- Make: Type : Kind of measurement ABB, Schneider, Siemens or equivalent 356- Rated Current : Rated AC input voltage Input consumption e) Current circuit f) Voltage circuit Accuracy class Number of AC input a) Current b) Voltage Display of measurement 78- 9- 10- 1112- Change-over of display of phase quantity e) AC Current f) AC voltage Display updating time Overload capacity e) Current circuit Digital type with LCD monitor 1) AC Current 2) AC Voltage 3) Active power with Max. demand indicator 4) Reactive power 5) Energy value 5A 110 V Less than 0.1 VA Less than 0.25VA Class 1.0 for all measurement 3 (R, B & E) 3 (R,Y, B) Simultaneous display of each one value for item 3., total 6 measurement quantities Push button Push button 1.0 sec. 40 times rated current for 1 sec.,1.2 times for continuous operation Bidders’ Offered specification No 1314151617- Description UNDP required specifications f) Voltage circuit 2 rated voltage for10 times sec., 1.2 times for continuous operation DC110V 5W Auxiliary power supply Auxiliary power consumption Bidders’ Offered specification Submit Manufacturer certification : Submit Detail drawing brochure catalogue Certificate or report of type test 19-Meters for MV Outgoing Feeder: No Description UNDP required specifications 123- Make: Type : Kind of measurement ABB, Schneider, Siemens or equivalent 356- Rated Current : Rated AC input voltage Input consumption e) Current circuit f) Voltage circuit Accuracy class Number of AC input a) Current b) Voltage Display of measurement 78- 910- 1112- Change-over of display of phase quantity e) AC Current f) AC voltage Display updating time Overload capacity e) Current circuit f) Voltage circuit 13141516- Auxiliary power supply Auxiliary power consumption Digital type with LCD monitor 1) AC Current 2) AC Voltage 3) Active power with Max. demand indicator 4) Reactive power 5) Energy value 5A 110 V Less than 0.1 VA Less than 0.25VA Class 1.0 for all measurement 3 (R, B & E) 3 (R,Y, B) Simultaneous display of each one value for item 3., total 6 measurement quantities Push button Push button 1.0 sec. 40 times rated current for 1 sec.,1.2 times for continuous operation 2 rated voltage for10 times sec., 1.2 times for continuous operation DC110V 5W Submit Manufacturer certification : Submit Detail drawing brochure catalogue Bidders’ Offered specification No Description 17- Certificate or report of type test UNDP required specifications Bidders’ Offered specification 20-Transformer Main Protection & Control Relay No Description UNDP required specifications 123356789- Make: Type : Rated AC input current Rated AC input voltage Auxiliary power supply Auxiliary power consumption Mounting Degree of protection Operating temperature range for a single 6 hour duration within any 24hour period TF H.V. Overcurrent relay (51P) a) Current setting range (IDMTL) ABB, Schneider, Siemens or equivalent 10-1 b) Current setting range (Instantaneous) c) Time-current characteristics 10-2 10-3- TF H.V. Restricted earth fault relay (51GP) a) Type of relay by Impedance b) Base differential setting (Idif.) c) Directional angle - Relay characteristic angle - Relay operate angle d) Operate time at 2 x Idif. e) Reset time -10_C to +65_C 10-500 % 10-2000 % Normal inverse Low impedance 5-50 % 180 deg +/-60 to +/-90 deg 25 ms 25 ms `Biased ratio Differential relay (87T) a) Type of compensation for ratio and vector difference between primary and secondary side 10-4 Numerical & multiple relay function 5A 110 V DC110 V To be filled in W Flush mounting IP52 Software(numerical) adaptation b) Base differential setting (Idif.) 10-50 % c) 2nd harmonics inrush restraint setting against the fundamental d) Non restraint differential set e) Operate time, restrained f) Reset time, restrained 5-100 % g) Operate time, unrestrained h) Reset time, unrestrained TF L.V. Overcurrent relay (51S) a) Current setting range (IDMTL) 500-2000 % on 25 ms at 2 x Idif 25 ms at 2 x Idif 12 ms at 5 x Idif 25 ms at 5 x Idif 10-500 Bidders’ Offered specification No Description UNDP required specifications b)Current setting range (Instantaneous) c) Time-current characteristics 10-5 Trip circuit supervision (TCS) a) Quantity b) Alarm delay time setting 11- Automatic Voltage Regulating relay (AVR 12- a) Voltage control set voltage b) Set voltage dead-band c) Time delay setting. d) Under voltage blocking setting Auxiliary relay or signal output a) Rated voltage of contacts b) b) Rated current of contacts - Continuous - Make and carry for 3 sec. 131415- Bidders’ Offered specification 10-2000 % Normal inverse One for each CB at TF H.V. & L.V. side 0-300 Sec. 85-120 % 0.6-9.0 % 1-300 Sec 50- 90 % 250 AC/DC 5A 10 A Submit Manufacturer certification : Submit Detail drawing brochure catalogue Certificate or report of type test 21-Transformer Back-up Protection Relay: No Description UNDP required specifications 1- Make: ABB, Schneider, Siemens or equivalent 2- Type : 3356789- Rated AC input current Rated AC input voltage Auxiliary power supply Auxiliary power consumption Mounting Degree of protection Operating temperature range for a single 6 hour duration within any 24hour period Numerical & multiple relay function 5A 110 V DC110 V To be filled in W Flush mounting IP52 10-1 Protection Relay: TF H.V. Overcurrent relay (51P) a) Current setting range (IDMTL) 10-500 % b) Current setting range (Instantaneous) 10-1200 % -10_C to +65_C c) Time-current characteristics Normal inverse Bidders’ Offered specification No Description 10-2 TF H.V. earth fault relay (51GP) a) Current setting range (IDMTL) b) Current setting range (Instantaneous c) Time-current characteristics b)Current setting range (Instantaneous) Normal inverse 10-2000 % c) Time-current characteristics Normal inverse 12- 131415- UNDP required specifications Bidders’ Offered specification 10-500 % 10-1200 % a) Voltage control set voltage b) Set voltage dead-band c) Time delay setting. d) Under voltage blocking setting Auxiliary relay or signal output b) Rated voltage of contacts b) Rated current of contacts - Continuous - Make and carry for 3 sec. 85-120 % 0.6-9.0 % 1-300 Sec 50- 90 % 251 AC/DC 5A 10 A Submit Manufacturer certification : Submit Detail drawing brochure catalogue Certificate or report of type test 22-Transformer L.V Protection & Control Relay: No Description UNDP required specifications 1- Make: ABB, Schneider, Siemens or equivalent 2- Type : 3356789- Rated AC input current Rated AC input voltage Auxiliary power supply Auxiliary power consumption Mounting Degree of protection Operating temperature range for a single 6 hour duration within any 24hour period Protection Relay on TF L.V. side: Under-voltage relay (27S) a) Voltage setting range 10-1 10-2 b) Time setting Under-frequency relay (81) a) Number of stages a) Setting range of frequency b) Time setting Numerical & multiple relay function 5A 110 V DC110 V To be filled in W Flush mounting IP52 -10_C to +65_C 10-100 % 0-60 Sec.) Not less than 2 35-75 Hz for each stage 0-60Sec.for each stage Bidders’ Offered specification No Description 12-3 Auxiliary relay or signal output c) Rated voltage of contacts b) Rated current of contacts - Continuous - Make and carry for 3 sec. Auxiliary relay or signal output a) Rated voltage of contacts 13131415- UNDP required specifications Bidders’ Offered specification 252 AC/DC 5A 10 A 250 V AC/DC Submit Manufacturer certification : Submit Detail drawing brochure catalogue Certificate or report of type test 23-Medium Voltage Feeder Protection Relay: No Description UNDP required specifications 1- Make: ABB, Schneider, Siemens or equivalent 2- Type : 33567-89-- Rated AC input current Rated AC input voltage Auxiliary power supply Auxiliary power consumption Mounting Degree of protection Operating temperature range for a single 6 hour duration within any 24hour period Protection Relay: a) Current setting range (IDMTL) b) Current setting range (Instantaneous) c) Time-current characteristics Earthfault relay (51GF) a) Current setting range(IDMTL) b) Current setting range (Instantaneous) c) Time-current characteristics 3-phase Auto-reclosing relay (79F) a) Number of reclosing shots b) Dead time. c) Reclaim time Auxiliary relay or signal output Rated voltage of contacts Numerical & multiple relay function 5A 110 V DC110 V To be filled in W Flush mounting IP52 10-1 10-2 12-3 13- -10_C to +65_C 30-250 % 50-2000 % Normal inverse 1-100 % 5-800 % Normal inverse 3 0.2-300 Sec 3-300 Sec. 250 V AC/DC Bidders’ Offered specification No Description 141516- Submit Manufacturer certification : Submit Detail drawing brochure catalogue UNDP required specifications Bidders’ Offered specification Certificate or report of type test 24-36 kV Power Cables for Incoming No Description 36KV incoming UNDP required specifications 1234- Make: Type : Rated Voltage Construction data 1) Number of conductor 2) Cross sectional area (Phase) 3) Shape of conductor 4) Material of conductor 5) Number of wires (Min.) 6) Material of conductor shielding 7) Thickness of conductor shielding (Approx.) 8) Material of insulation 9) Thickness of insulation (Nominal) 10) Material of insulation shielding 11) Thickness (Approx.) 12) Material of shielding 13) Thickness of copper tape (Approx.) 14) Material of sheath 15) Thickness of sheath (Nominal) 16) Material of armor 17) Color of sheath 18) Overall diameter of cable (Approx.) 19) Marking of cable 20) Net weight (Approx.) (kg/km) 5- Have vender list in Iraq CU/XLPE/PVC 18/30 (36) kV 1 Core 500 mm2 Circular stranded Compacted Copper 53 Semi conductive Compound 0.6 mm XLPE 8.0 mm Strippable semi conductive Compound 1.0 mm Copper taps 1 nos. x 0.1 mm PVC 2.6 mm N.A Black 51 mm To be filled in To be filled in `Electrical data: 1) AC. withstand voltage for 5 minutes 2) Impulse withstand voltage 3) Max. DC. conductor resistance at 20_C 0.0366 ohm/km 4) Max. Temperature rating of conductor 90 _C 5) Max. current rating (touching flat formation) in ground at 20_C) 6) Rated Frequency 7) Max. Partial discharge at 31.2kV 63 kV 170KV 810 A (*1 50 Hz 10 pC Offered specification No Description 36KV incoming UNDP required specifications Under-voltage relay (27S) Voltage setting range 1315- Offered specification 10-100 % Submit Manufacturer certification : Certificate or report of type test 25-36 kV Power Cables for Feeder No Description 36KV incoming UNDP required specifications 1234- Make: Type : Rated Voltage Construction data 1) Number of conductor 2) Cross sectional area (Phase) 3) Shape of conductor 4) Material of conductor 5) Number of wires (Min.) 6) Material of conductor shielding CU/XLPE/PVC With armor 18/30 (36) kV 1 Core 150 mm2 Circular stranded Compacted Copper 18 Semi conductive Compound 7) Thickness of conductor shielding (Approx.) 8) Material of insulation 0.6 mm 9) Thickness of insulation (Nominal) 10) Material of insulation shielding 8.0 mm Strippable semi conductive Compound 1.0 mm metallic taps 11) Thickness (Approx.) 12) Material of shielding 13) Thickness of copper tape (Approx.) 14) Material of sheath 15) Thickness of sheath (Nominal) 16) Material of armor 17) Color of sheath 18) Overall diameter of cable (Approx.) 19) Marking of cable 20) Net weight (Approx.) (kg/km) 5- Have vender list in Iraq XLPE 1 nos. x 0.085 mm PVC 2.4 mm Aluminum wire Black 46 mm To be filled in To be filled in(kg/km) `Electrical data: 1) AC. withstand voltage for 5 minutes 2) Impulse withstand voltage 3) Max. DC. conductor resistance at 20_C 0.124 ohm/km 4) Max. Temperature rating of conductor 90 _C 5) Max. current rating (touching flat formation) in ground at 20_C) 6) Rated Frequency 63 kV 170KV 420 A (*1) 50 Hz Bidders’ Offered specification No Description 36KV incoming UNDP required specifications 7) Max. Partial discharge at 31.2kV Under-voltage relay (27S) Voltage setting range 1315- Bidders’ Offered specification 10 pC 10-100 % Submit Manufacturer certification : Certificate or report of type test 26-Low Voltage Power Cables No Description 36KV incoming UNDP required specifications 123456 789- 10111213- Make: Type : Location Of service Rated Voltage Type of insulation Offered specification Have vender list in Iraq CU/XLPE/PVC With armor Outdoor 600 V XLPE Number of conductor 4 Core Type of sheath materials Cable size PVC 60 mm2 Conductor : a) Materials b) Strands c) Outer diameter (Approx.) Thickness of insulation (Nominal) Thickness of sheath (Nominal) Overall diameter (Approx.) Conductor resistance at 20_C Copper 19/Smooth body 9.3 mm 1.5 mm 2.0 mm 34 mm 0.311o hm/km (Maximum) 14151617- Insulation resistance (Minimum) AC. withstand voltage 1500 M-ohm km 2500 V Submit Manufacturer certification : Certificate or report of type test 27- Plug in Type Connectors of Control cable (For connection between Trailers) No Description 36KV incoming UNDP required specifications 12- Make: Type : 34- Location Of service Applicable temperature a) Minimum temperature b) Maximum temperature Number of pins 5- To be filled in Plug in with water proof & dust proof type Outdoor -55 °C +85 °C 27 Bidders’ Offered specification 6 Type of contact 40 km/h Crimp pin & crimp socket contact 2.0 to 3.5 mm2 AC 1000 V 23 A for 3.5mm2 17A for 2.0mm2 789- Applicable wire size Rated voltage Rated current (Max.) 1011- Submit Manufacturer certification : Certificate or report of type test 28- Trailer: UNDP required specifications 1234- 7- Make: Type : Tractor (make and type) Principal dimension and weight a) Overall length b) Overall width To be filled in (mm) c) Overall height (unladed) d) Floor height) e) Wheel base f) Tare weight) g) Maximum payload) h) Gross vehicle weight Distribution weight a) Unladen - King pin (front axle) - Rear axle b) Laden - King pin (front axle) - Rear axle Size and quantity of Tire & wheel a) Tire - Front axle - Fear axle b) wheel - Front axle - Rear axle Type of parking brake 8910- Type of Service brake Type of suspension Type of landing gears 11- Type of vehicle coupling device (king pin) 5- 6- According to Iraq standard Drop-bed semi-trailer To be filled in To be filled in (mm) To be filled in (mm) To be filled in (mm) To be filled in (mm To be filled in (mm) To be filled in (kg To be filled in (kg To be filled in (kg) To be filled in (kg) To be filled in (kg) To be filled in (kg) To be filled in (kg To be filled in To be filled in To be filled in To be filled in Valve operating, spring loaded chamber Air “S” cam type Triple spring type Left and right combined operation, high and low speed range, manual operation with square pads SAE 3.5 inches Bidders’ Offered specification UNDP required specifications 12- Electric system a) Voltage b) Receptacle type Bidders’ Offered specification 24 V 7 poles (SAE) Section 8: FORM FOR BID SECURITY (This must be finalized using the official letterhead of the Issuing Bank. Except for indicated fields, no changes may be made in this template.) To: The Resident Representative, UNDP [Insert contact information as provided in Data Sheet] WHEREAS [name and address of Contractor] (hereinafter called “the Bidder”) has submitted a Bid to UNDP dated Click here to enter a date. , to deliver goods and execute related services for [indicate ITB title] (hereinafter called “the Bid”): AND WHEREAS it has been stipulated by you that the Bidder shall furnish you with a Bank Guarantee by a recognized bank for the sum specified therein as security in the event that the Bidder: a) Fails to sign the Contract after UNDP has awarded it; b) Withdraws its Bid after the date of the opening of the Bid; c) Fails to comply with UNDP’s variation of requirement, as per ITB Section F.3; or d) Fails to furnish Performance Security, insurances, or other documents that UNDP may require as a condition to rendering the contract effective. AND WHEREAS we have agreed to give the Bidder such this Bank Guarantee: NOW THEREFORE we hereby affirm that we are the Guarantor and responsible to you, on behalf of the Bidder, up to a total of [amount of guarantee] [in words and numbers], such sum being payable in the types and proportions of currencies in which the Price Bid is payable, and we undertake to pay you, upon your first written demand and without cavil or argument, any sum or sums within the limits of [amount of guarantee as aforesaid] without your needing to prove or to show grounds or reasons for your demand for the sum specified therein. This guarantee shall be valid until 30 days after the date of validity of the bids. SIGNATURE AND SEAL OF THE GUARANTOR BANK Date ....................................................................................................................... Name of Bank ......................................................................................................... Address .................................................................................................................