Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Decomposition of trichloroethylene in a plasma-catalytic process Jelle Reyniers Supervisors: Prof. dr. Rino Morent, Prof. dr. ir. Nathalie De Geyter Counsellors: Ir. Arne Vandenbroucke, Sharmin Sultana Master's dissertation submitted in order to obtain the academic degree of Master of Science in Chemical Engineering Department of Applied Physics Chairman: Prof. dr. ir. Christophe Leys Faculty of Engineering and Architecture Academic year 2014-2015 Decomposition of trichloroethylene in a plasma-catalytic process Jelle Reyniers Supervisors: Prof. dr. Rino Morent, Prof. dr. ir. Nathalie De Geyter Counsellors: Ir. Arne Vandenbroucke, Sharmin Sultana Master's dissertation submitted in order to obtain the academic degree of Master of Science in Chemical Engineering Department of Applied Physics Chairman: Prof. dr. ir. Christophe Leys Faculty of Engineering and Architecture Academic year 2014-2015 Acknowledgements This master dissertation represents not only my experimental and written work during the last year, it is also a milestone of my 6 years long engineering studies. I am sure that I will later nostalgically and with a smile think back to this educational period. This work could not have been successfully finished without the help of several people, which I would first like to thank. First and foremost I wish to thank my supervisors, Prof. dr. R. Morent and Prof. dr. ir. N. De Geyter, for the chance they give me to perform my thesis at the faculty of applied physics. As chemical engineer, the choice for plasma physics was a step into the unknown, but one I have never complained. Lot of thanks to my counsellors, Ir. A. Vandenbroucke and S. Sultana, for the support on theoretical and practical level. They were very motivated to guide me, and I could always count on quick feedback when I had questions. Special thanks to J. Peelman for solving technical problems concerning my experimental set-up. Finally I want to thank my parents for the opportunity they give me to study at the university, and to buy me a laptop to write my thesis. Ghent, May 22, 2015 Jelle Reyniers Permission for usage The author gives permission to make this master dissertation available for consultation and to copy parts of this master dissertation for use. In case of any other use, the copyright terms have to be respected, in particular with regard to the obligation to state expressly the source when quoting results from this master dissertation. Ghent, May 22, 2015 The supervisors, Prof. dr. Rino Morent The author, Prof. dr. ir. Nathalie De Geyter Jelle Reyniers Decomposition of trichloroethylene in a plasma-catalytic process Jelle Reyniers Supervisors: Prof. dr. R. Morent and Prof. dr. ir. N. De Geyter Counsellors: Ir. A. Vandenbroucke and S. Sultana Abstract: In this work, the decomposition of trichloroethylene (TCE) is investigated in a plasma-alone and post plasma-catalytic system with CeO2, K-OMS-2 and Fe3O4/K-OMS-2. The influence of several process parameters such as air humidity, gas flow rate and TCE inlet concentration is investigated. In the absence of a catalyst, the maximal TCE removal efficiency is obtained at an air humidity of 15 %. In addition, humid air also enhanced the CO x selectivity of the TCE removal process. A decrease of the TCE inlet concentration had a positive effect on both TCE removal efficiency and COx selectivity. However, the carbon mass balances during the plasma-alone experiments are poor due to the formation of polychlorinated by-products such as phosgene, dichloroacetylchloride (DCAC) and trichloroacetaldehyde (TCAA). Addition of a catalyst downstream of the plasma reactor clearly improved the TCE removal efficiency and COx selectivity compared to the plasma-alone process, even at low energy density (40 – 80 J·L-1) and catalyst temperature (150 – 200 °C). The use of K-OMS-2 led to a removal efficiency of 86 % and a COx selectivity of 57 %, when operating at 40 J·L-1. Addition of Fe3O4 nanoparticles to K-OMS-2 further increased the COx selectivity with 15 %, but led to a decrease of the removal efficiency with 24 %. The disadvantage of the cryptomelane type catalysts is their high sensitivity to deactivation, possibly caused by chlorinated byproducts. CeO2 is less prone to deactivation but resulted in a lower removal efficiency (66 %) and COx (23 %) selectivity, under the same process conditions. Keywords: non-thermal plasma, trichloroethylene, plasma catalysis, multi-pin-to-plate reactor, FT-IR spectroscopy I. INTRODUCTION During the last decades, research revealed the existence of several environmental problems caused by human activities and stressed the negative impact of air pollution on health. In addition, the media attention for these problems caused a growing environmental awareness among the population, and stimulated the research on developing methods to reduce the emission of air pollutants [1]. Volatile organic compounds (VOCs) are a large group of chemical compounds that strongly contribute to poor air quality. Several VOCs are very harmful to human health due to their carcinogenic and mutagenic effects. Hence, different techniques have been developed to control VOC emissions such as thermal/catalytic oxidation, adsorption and bioprocesses each with their own advantages and limitations. As a cost and energy efficient alternative, the use of nonthermal plasma (NTP) has been recognized to be relevant for the removal of VOCs from dilute atmospheric pressure gas streams [2, 3]. The use of NTP is attractive since the supplied energy is used for the acceleration of electrons, instead of heating up the total gas volume. The energetic electrons collide with background molecules leading to the formation of reactive radical species, which in turn react with VOCs. The major drawback of the NTP removal technique is the formation of byproducts (e.g. ozone, NOx), which can be more harmful than the target VOC itself. An attempt to overcome these limitations is to combine NTP with heterogeneous catalysis [4-6]. Plasma-assisted catalysis is able to eliminate toxic pollutants at low temperature due to a higher energy efficiency leading to a low energy cost. Furthermore, the development of a suitable catalyst will help to optimize the selectivity into environmentally more friendly end products. By placing the catalyst downstream of the discharge zone (so-called post plasma-catalytic system), the catalyst is able to decompose ozone formed in NTP into active oxygen species able to greatly improve the oxidation of both the target VOC and hazardous byproducts. In this work, the abatement of TCE in a post plasma-catalytic (PPC) system is studied. NTP is generated in a DC multi-pin-toplate corona/glow discharge. Several catalysts are investigated and evaluated based on the TCE removal efficiency, COx selectivity and formation of by-products. The influence of several parameters (gas flow rate, humidity, TCE inlet concentration) on the performance of the plasma-alone and plasma-catalytic system is investigated. Focus is on operating at low energy density in combination with low catalyst temperature to improve the energy efficiency of the TCE abatement process. II. EXPERIMENTAL SET-UP Figure 1 shows a schematic diagram of the experimental set- up. The inlet gas is supplied by a bottle of pressurized dry (< 3 ppm H2O) air (Alphagaz 1, Air Liquide) and is separated into three flows by means of three mass flow controllers (Bronkhorst®, El-Flow® select). The upper controller regulates the TCE concentration by passing air through a bubbling bottle containing liquid TCE (99.99% purity, Acros). The second controller is needed to adjust the total gas flow rate of the inlet, while the third controller regulates the gas flow through a H 2O containing bubbling bottle. The latter is needed to adjust the humidity level of the inlet gas. The TCE abatement and the identification of the by-products were determined with a FT-IR spectrometer (Bruker, Vertex 70) in combination with a Quadrupole MS spectrometer (Hiden Analytical, HPR 20 QIC). The optical length of the gas cell and the resolution of the FTIR spectrometer were set at 20 cm and 4 cm-1, respectively. Spectra were taken after steady state condition and OPUS (Bruker) software is used to collect and analyze the obtained spectra. IR transparent by-products are determined via MS analysis in the mass range 0 – 150 m/ z. The formation of ozone is analyzed by an ozone monitor (Teledyne API Model 450 O 3 Monitor). A multi-pin-to-plate configuration is applied as plasma reactor, and is based on the concept of a negative DC corona/glow discharge. The plasma source consists of ten aligned sharp hollow crown-shaped cathode pins, connected in parallel and positioned 28 mm from each other. The anode plate is profiled with spherical surface segments centered on the tip of each cathode pin. The discharge is generated by applying an electric field between the cathode pins and the anode plate using a DC power supply (Technix, SR40-R-1200) at atmospheric pressure and room temperature. Uniform and stable glow discharge operation is ensured by ballasting each cathode pin with a 1.5 MΩ resistor. The K-OMS-2 type catalysts were prepared in cooperation with UCCS (Unité de Catalyse et de Chimie du Solide) from the university of Lille. CeO2 was purchased from Panreac. Before its use, the catalyst was calcinated for 4 h at 350 or 500 °C under a stream of dry air with a flow of 200 ml·min-1. For all tests, 0.5 g of catalyst powder was diluted with 3 g of carborundum and introduced in a cylindrical glass reactor located in a temperature controlled tubular oven operating in the temperature range of 100 – 300 °C. The measurements were performed after thermal balance was reached. III. RESULTS AND DISCUSSION A. Plasma-assisted TCE abatement The experiments with NTP were evaluated based on the TCE removal efficiency (η) and the selectivity towards CO and CO2, calculated as follows: Ƞ = (1 − SCO = SCO2 = CTCE,out ) · 100 CTCE,in CCO η · CTCE,in · 2 (1) (2) · 100 CCO2 · 100 η · CTCE,in · 2 (3) SCOx = SCO + SCO2 (4) In addition to CO and CO2, the formation of hazardous polychlorinated by-products such as phosgene, trichloroacetaldehyde (TCAA) and dichloroacetylchloride (DCAC) was detected via FT-IR. Influence of gas flow rate Figure 2 shows the evolution of the TCE removal efficiency as function of the energy density for two different gas flow rates (0.5 and 2 L·min-1). Until an energy density of 175 J∙L-1, the gas flow rate has no visible effect on the removal efficiency. A further increase of the energy density results in a slower rise of the removal efficiency for a gas flow rate of 0.5 L∙min-1, compared to 2 L∙min-1. If more than 80 % of TCE has to be removed in polluted air, it is better to operate at higher gas flow rates to minimize the energy to be supplied per unit of gas volume. Moreover, more polluted air can be treated per unit of time when operating at a higher gas flow rate. 0.5 L/min 2.0 L/min Removal efficiency (%) 100 90 80 70 60 50 40 Figure 1: Schematic diagram of the experimental set-up 0 200 400 600 Energy density (J/L) 800 1000 Figure 2: TCE removal efficiency as function of the energy density, for a gas flow rate of 0.5 and 2 L∙min-1 (dry air, CTCE = 500 ppm, T = 293 K, atmospheric pressure) In contrast to the negative effect of decreasing gas flow rate on TCE removal, the lowest gas flow rate resulted in the highest selectivity towards CO and CO2. The gas flow rate had no significant influence on the formation of by-products HCl, ozone, phosgene and DCAC. Influence of humidity Water plays an important role for the removal of TCE due to the formation of reactive hydroxyl radicals in NTP. A relative humidity (RH) of 15 % resulted in the highest values for the TCE removal efficiency for given energy density. This optimal humidity level depends on the optimal balance between the enhancement and inhibition effect of water on TCE removal. The removal of TCE is enhanced with increasing humidity due to the formation of strong oxidizing hydroxyl radicals via H2 O + O → 2 OH Influence of TCE inlet concentration As shown in Figure 4, a decreasing TCE inlet concentration enhanced the removal efficiency, and can be explained as follows. Each TCE molecule shares fewer electrons and reactive plasma species with increasing inlet concentration, thereby reducing the probability of reaction between these species and a certain TCE molecule. A lower TCE concentration also enhanced the selectivity towards CO and CO2 due to the higher amount of oxygen radicals present in NTP. The formation of phosgene and DCAC was strongly reduced with decreasing TCE concentration, while the production of ozone was increased. (5) OH + O → O2 + H OH + ClO → HCl + O2 (6) (7) Since ClO and oxygen radicals significantly decompose TCE [7], a reduced amount of these radicals by OH leads to a suppression of the removal efficiency at high humidity levels. The presence of water increased the COx selectivity of the TCE removal process due to the strong oxidizing power of hydroxyl radicals, shown in Figure 3. An increase of the humidity from 5 to 80 % RH led to a shift in COx selectivity from 8.5 to 18.5 %, at an energy density of 75 J·L-1. However the COx selectivity remains low, indicating that TCE is mainly decomposed into chlorinated by-products. 250 ppm TCE 5% RH 10% RH 20% RH 50% RH 80% RH 80 70 60 50 40 30 15% RH 200 400 600 Energy density (J/L) 800 1000 Figure 4: TCE removal efficiency as a function of the energy density for different TCE inlet concentrations. (dry air, Q = 0.5 L·min-1, T = 294 K, atmospheric pressure) 20 18 16 COx selectivity (%) 750 ppm TCE 90 0 2.8% RH 500 ppm TCE 100 Removal efficiency (%) On the other hand, water has a negative effect on TCE abatement since OH radicals strongly react with ClO and oxygen radicals via B. Plasma-catalytic TCE abatement 14 12 10 8 6 4 2 0 0 50 100 150 200 250 Energy density (J/L) 300 350 Figure 3: COx selectivity of the TCE abatement process as function of the energy density for different humidity levels. (humid air, CTCE = 500 ppm, Q = 2 L·min-1, T = 294.5 K, atmospheric pressure) Moreover, humidity enhanced the formation of oxidation product HCl and suppressed the production of hazardous byproducts ozone and DCAC. Contrary, the presence of water led to a small increase of the phosgene concentration in the outlet gas. To improve the TCE abatement process a catalyst was placed downstream of the plasma source, in a so-called post plasmacatalytic (PPC) system. This enhanced the process performance and induced a synergetic effect. Ozone plays an important role in this since it can dissociate on the catalyst surface into active oxygen species. These active species desorb from the surface and oxidize chlorinated by-products and residual TCE, thereby enhancing the removal efficiency and COx selectivity. To evaluate the synergy in the PPC process, a synergy factor fTCE is introduced as ηplasma−catalysis (8) fTCE = ηplasma−alone + ηcatalyst−alone During the plasma-catalytic experiments three different catalysts were investigated: CeO2, K-OMS-2 and Fe3O4/KOMS-2. CeO2 In dry air, the highest TCE removal efficiency was achieved for a catalyst temperature of 150 °C. Operating at 40 and 80 J·L1 resulted in a TCE removal of 66 and 81 %, respectively. This Cl2 + O → Cl + ClO C2 HCl3 + ClO → COCl2 + CHCl2 (9) (10) Cl by-products 90 80 PPC 100°C PPC 250°C 100 PPC 150°C PPC 300°C PPC 200°C 90 80 70 60 50 40 30 CO 20 CO2 10 0 70 Selectivity (%) the COx selectivity due to the strong oxidizing power of OH radicals. The effect of humidity on the formation of oxygen species on the catalyst surface is negligible since the catalyst is only little activated at low temperature. An increase of the catalyst temperature resulted in a maximal COx selectivity at a humidity of 20 % RH. This humidity level led to the highest COx selectivity due to the combination of strong oxidizing hydroxyl radicals and a high amount of ozone decomposed on the catalyst surface. A higher humidity inhibits the ozone formation and production of active oxygen species, explaining the decreasing COx selectivity. COx selectivity (%) corresponds to an enhancement of 15 % (for both energy density) compared to the plasma-alone system. The synergetic effect is clearly visible since the TCE removal efficiency in the catalyst-alone system did not exceed 1 %. An increase of the catalyst temperature from 150 to 300 °C slightly reduced the TCE removal from 81 to 77 %, at 80 J·L-1. This is possibly caused by little catalyst deactivation due to irreversible adsorption of chlorinated by-products. The PPC system also enhanced the COx selectivity compared to the plasma-alone system, as shown in Figure 5. Operating at 40 J·L-1 and a catalyst temperature of 150 °C resulted in a COx selectivity of 23 %, compared to 9.3 % in NTP. An increase from 150 to 300 °C led to a shift in COx selectivity from 23 to 60 % due to activation of the ozone decomposition on the catalyst surface. The enhanced oxidation with increasing temperature resulted in an increased and decreased formation of HCl and DCAC, respectively. Remarkable was the increased phosgene production at higher catalyst temperature. A possible explanation is the increased formation of ClO radicals with temperature which further react with TCE towards phosgene via 0 60 10 20 30 40 50 60 Relative humidity (%) 70 80 Figure 6: The selectivity of the TCE removal process towards COx in a plasma-catalytic (CeO2) system as a function of the relative humidity, at an energy density of 280 J·L-1. (humid air, CTCE = 500 ppm, Q = 0.5 L·min-1, T = 294.5 K, atmospheric pressure) 50 40 30 Just as in the plasma-alone experiments, an increase of humidity resulted in an increase and decrease of phosgene and DCAC, respectively. An increase of the catalyst temperature towards 300 °C completely removed DCAC. 20 10 0 NTP PPC 100°C PPC 150°C PPC 200°C PPC 250°C PPC 300°C Figure 5: The selectivity of the TCE removal process towards CO, CO2 and chlorinated by-products in a plasma-catalytic (CeO2) and a plasmaalone system for different temperatures, at an energy density of 40 J·L1. (dry air, C -1 TCE = 500 ppm, Q = 0.5 L·min , atmospheric pressure) The experiments with humid air were performed at an energy density of 280 and 400 J·L-1. This high energy density was needed to light up all cathode pins since the electronegativity character of water resulted in a reduced electron density. An increase of the humidity from 2.8 (dry) to 80 % resulted in a small decrease of the removal efficiency from 95 to 87 %, when operating at 280 J·L-1. This can be partly ascribed to a decrease in catalytic ozone decomposition under humid conditions since the amount of converted ozone is directly related to the concentration of newly formed active oxygen species over the catalyst surface. Another possible explanation is that the competitive adsorption of water inhibits the adsorption of TCE, thereby reducing the catalytic removal of TCE. The influence of the humidity and catalyst temperature on the COx selectivity of the PPC system is plotted in Figure 6. At low catalyst temperature (< 200 °C) humidity positively influences Cryptomelane (K-OMS-2) The PPC experiments with K-OMS-2 were performed with dry (2.8 % RH) and humid (15 % RH) air at a catalyst temperature of 150 °C. Figure 7 shows the TCE removal efficiency in NTP and PPC system as function of the energy density. The experiments with dry air resulted in the highest removal efficiency. At a catalyst temperature of 150 °C, operating at 40 and 80 J·L-1 resulted in a removal efficiency of 86 and 94 %, respectively. This corresponds to a synergy factor of 1.60 and 1.37 for 40 and 80 J·L-1, respectively and is clearly higher than in the PPC system with CeO2. The synergetic effect during the experiments with humid air was negligible. PPC - dry NTP - dry PPC - 15% RH NTP - 15% RH 100 Removal efficiency (%) 90 80 70 60 50 40 30 50 100 150 Energy density (J/L) 200 250 Figure 7: TCE removal efficiency in a plasma-alone and plasmacatalytic (K-OMS-2) system as function of the energy density, for two different humidity levels. (humid air, CTCE = 500 ppm, Q = 0.5 L·min1, T = 295.5 K, atmospheric pressure) The COx selectivity also reached higher values compared to CeO2. At 150 °C and 40 J·L-1, a value of 57 % was reached. An increase of the humidity from 2.8 to 15 % resulted in a further increase to 71 % due to the strong oxidizing power of hydroxyl radicals. For both dry and humid air, an increase of the energy density in time from 40 to 250 J·L-1 resulted in a decrease of the COx selectivity with 13 %. This was remarkable since the opposite effect was observed during the plasma-alone and PPC experiments with CeO2. The decreasing COx selectivity can be explained by significant deactivation of the catalyst. Figure 8: The selectivity of the TCE removal process towards COx in a plasma-alone and plasma-catalytic system with K-OMS-2 and Fe3O4/K-OMS-2 as function of the energy density. (dry air, CTCE = 500 ppm, Q = 0.5 L·min-1, T = 295.5 K, atmospheric pressure) Analysis of the FT-IR outlet spectra of the PPC experiments with K-OMS-2 and Fe3O4/K-OMS-2 revealed the presence of two new bands at 794 and 772 cm-1 (Figure 9), corresponding to CCl4 and CHCl3, respectively. These compounds were not detected in the plasma-alone and PPC system with CeO2, and may be likely formed through carbon-carbon cleavage of DCAC and TCAA. Fe3O4/K-OMS-2 K-OMS-2 CeO2 NTP CCl4 0.14 0.12 CHCl3 0.1 Fe3O4/K-OMS-2 This cryptomelane composite is synthesized to improve the TCE abatement to total oxidation since Fe3O4 is known for its oxidizing properties. As presented in Figure 8, the use of Fe3O4/K-OMS-2 resulted in an increase of the COx selectivity with 15 % compared to K-OMS-2, at low energy density (40 – 80 J·L-1). However, an increase of the energy density in time again resulted in a reduction of the COx selectivity due to catalyst deactivation. In contrast to CO x selectivity, Fe3O4/KOMS-2 resulted in a significant decrease (23 %) of the TCE removal efficiency compared to K-OMS-2. The synergetic effect was negligible. 0.08 0.06 Absorbance (-) 0 0.04 0.02 0 810 800 790 780 770 Wavenumber (cm-1) 760 750 Figure 9: FT-IR spectra between 810 and 750 cm-1 of the outlet gas in the plasma-alone and PPC system with CeO2, K-OMS-2 and Fe3O4/KOMS-2, at a catalyst temperature of 150 °C. The spectra were measured at a TCE conversion between 85 – 87 %. (dry air, CTCE = 500 ppm, Q = 0.5 L·min-1, T = 295.5 K, atmospheric pressure) C. Plasma-catalytic TCE abatement scheme The TCE abatement and selectivity results obtained in the PPC system for different catalysts suggest a simplified reaction scheme for the TCE abatement that is represented in Figure 10. First, electron-molecule collisions in NTP convert N2 and O2 molecules to a mixture of ionized, excited, metastable and radical species that are able to decompose TCE to polychlorinated intermediates (phosgene, DCAC, TCAA) and total oxidation products (CO, CO2, HCl, Cl2). Molecular oxygen is also involved in a three body reaction leading to the formation of O3. Downstream of the plasma source, O3 comes into contact with the catalyst surface and dissociates towards molecular and radical oxygen species. These surface species promote the further oxidation of residual TCE and chlorinated by-products towards CO, CO2, HCl and Cl2 via pathway 1. In case of cryptomelane-type catalysts (K-OMS-2 and Fe3O4/K-OMS-2) an additional reaction path (pathway 2) is present, leading to the formation of CCl4 and CHCl3 through carbon-carbon cleavage of DCAC and TCAA. the removal efficiency with 24 %. The disadvantage of cryptomelane type catalysts is the fast deactivation rate. CeO 2 is less sensitive to deactivation but resulted in a lower removal efficiency (66 %) and COx (23 %) selectivity, under the same conditions. ACKNOWLEDGEMENTS The author would like to acknowledge the supervisors and counsellors for their support. REFERENCES [1] [2] [3] [4] [5] [6] [7] Figure 10: Simplified TCE degradation scheme in a plasma-catalytic process IV. CONCLUSION The decomposition of TCE was investigated by NTP generated in a DC multi-pin-to-plate corona/glow discharge and post plasma-catalytic system using CeO2, K-OMS-2 and Fe3O4/K-OMS-2 as catalyst. Regarding the plasma-alone process: - Higher gas flow rates positively influenced the TCE removal, but led to a decrease of the COx selectivity. - A maximal TCE removal efficiency is obtained for an air humidity of 15 % RH. - The COx selectivity is enhanced in humid air due to the oxidizing power of OH radicals. - A lower TCE inlet concentration has a positive effect on both TCE removal efficiency and COx selectivity. - The carbon mass balances are poor and hazardous by-products such as phosgene, DCAC, TCAA and ozone are observed along with oxidation products COx, HCl and Cl2. The PPC experiments showed that the addition of a catalyst downstream of the NTP reactor enhanced the TCE removal efficiency and COx selectivity due to the ability of the catalyst to decompose O3 towards active oxygen species able to oxidize the polychlorinated by-products and residual TCE. A removal efficiency and COx selectivity of 86 and 57 % were reached with K-OMS-2, when operating at 40 J·L-1 and a catalyst temperature of 150 °C. Addition of Fe3O4 nanoparticles to K-OMS-2 further increased the COx selectivity with 15 %, but led to a decrease of G. R. Parmar and N. N. Rao, "Emerging control technologies for volatile organic compounds," Critical Reviews in Environmental Science and Technology, 2008. 39(1): pp. 41-78. J. Van Durme, J. Dewulf, C. Leys, H. Van Langenhove, "Combining nonthermal plasma with heterogeneous catalysis in waste gas treatment: A review," Applied Catalysis B: Environmental, 2008. 78: pp. 324-333. A. M. Vandenbroucke, R. Morent, N. De Geyter, C. Leys, "Non-thermal plasmas for non-catalytic and catalytic VOC abatement," Journal of Hazardous Materials, 2011. 195: pp. 30-54. A. M. Vandenbroucke, M. Mora, C. Jiménez-Sanchidrián, F. J. RomeroSalguero, N. De Geyter, C. Leys, R. Morent, "TCE abatement with a plasma-catalytic combined system using MnO2 as catalyst," Applied Catalysis B: Environmental, 2014. 156: pp. 94-100. R. Morent, J. Dewulf, N. Steenhaut, C. Leys, H. Van Langenhove, " Hybrid plasma-catalyst system for the removal of trichloroethylene in air," Journal of Advanced Oxidation Technologies, 2006. 9(1): pp. 53-58. Y. Li, Z. Fan, J. Shi, Z. Liu, W. Shangguan, "Post plasma-catalysis for VOCs degradation over different phase structure MnO2 catalysts," Chemical Engineering Journal, 2014. 241: pp. 251-258. A. M. Vandenbroucke, R. Aerts, W. Van Gaens, N. De Geyter, C. Leys, R. Morent, A. Bogaerts, "Modeling and Experimental Study of Trichloroethylene Abatement with a Negative Direct Current Corona Discharge," Plasma Chemistry and Plasma Processing, 2015. 35: pp. 217-230. Table of contents 1 Preface ................................................................................................................................ 1 Problem statement ....................................................................................................... 1 Objectives .................................................................................................................... 2 PART 1: LITERATURE REVIEW 2 Volatile organic compounds ............................................................................................. 4 Definition ..................................................................................................................... 4 Trichloroethylene......................................................................................................... 6 Removal techniques for VOCs .................................................................................... 7 3 2.3.1 Thermal oxidation ................................................................................................ 8 2.3.2 Catalytic oxidation ............................................................................................... 9 2.3.3 Biological VOC removal ...................................................................................... 9 2.3.4 Adsorption ............................................................................................................ 9 2.3.5 Upcoming removal methods .............................................................................. 10 Plasma technology ........................................................................................................... 11 Definition ................................................................................................................... 11 Thermal and non-thermal plasma .............................................................................. 11 Characterization parameters of VOC abatement ....................................................... 13 3.3.1 Reduced electric field ......................................................................................... 13 3.3.2 Energy density .................................................................................................... 14 3.3.3 Removal efficiency ............................................................................................ 14 3.3.4 CO, CO2 and COx selectivity ............................................................................. 15 Discharge types in NTP ............................................................................................. 15 3.4.1 DC discharges .................................................................................................... 16 3.4.2 AC discharges .................................................................................................... 19 3.4.3 Pulsed corona discharge ..................................................................................... 22 TCE abatement in NTP.............................................................................................. 23 Ozone formation in NTP ........................................................................................... 25 4 Plasma catalysis ............................................................................................................... 26 Definition ................................................................................................................... 26 In-plasma vs. post-plasma catalysis........................................................................... 26 4.2.1 Plasma-catalyst interactions in IPC systems ...................................................... 26 4.2.2 Plasma-catalyst interactions in PPC systems ..................................................... 28 Common used catalysts ............................................................................................. 28 5 4.3.1 MnO2 based catalysts ......................................................................................... 28 4.3.2 Al2O3 based catalysts ......................................................................................... 29 4.3.3 TiO2 based catalysts ........................................................................................... 29 4.3.4 Zeolites ............................................................................................................... 29 Analytical techniques ...................................................................................................... 31 Infrared spectroscopy ................................................................................................ 31 Mass spectrometry ..................................................................................................... 33 PART 2: EXPERIMENTAL STUDY 6 Materials and methods ................................................................................................... 36 Experimental set-up ................................................................................................... 36 Gas inlet preparation .................................................................................................. 36 Plasma reactor............................................................................................................ 37 Catalytic unit.............................................................................................................. 39 6.4.1 Catalyst preparation............................................................................................ 40 6.4.2 Pressure drop over catalyst bed .......................................................................... 41 Gas outlet analysis ..................................................................................................... 41 7 6.5.1 FT-IR analysis .................................................................................................... 42 6.5.2 MS analysis ........................................................................................................ 44 6.5.3 Ozone monitor .................................................................................................... 45 Plasma characterization ................................................................................................. 46 Influence of gas flow rate .......................................................................................... 47 Influence of humidity ................................................................................................ 49 Influence of TCE ....................................................................................................... 52 8 Plasma-assisted TCE abatement ................................................................................... 55 Identification of TCE abatement products ................................................................. 55 Influence of gas flow rate .......................................................................................... 62 Influence of humidity ................................................................................................ 67 Influence of TCE ....................................................................................................... 73 9 Plasma-catalytic TCE abatement .................................................................................. 77 Cerium oxide (CeO2) ................................................................................................. 77 9.1.1 Dry air experiments ............................................................................................ 78 9.1.2 Influence of humidity ......................................................................................... 84 Cryptomelane (K-OMS-2) ......................................................................................... 89 9.2.1 Influence of humidity ......................................................................................... 89 9.2.2 Catalyst deactivation .......................................................................................... 92 Fe3O4/K-OMS-2 ........................................................................................................ 94 Plasma-catalytic TCE abatement scheme .................................................................. 97 10 Conclusion ....................................................................................................................... 99 Appendix ............................................................................................................................... 103 References ............................................................................................................................. 108 Abbreviations and symbols 𝑎 Molar absorption coefficient [L·mol-1·cm-1] Ȧ Angstrom A Absorbance AC Alternating current c Speed of light [cm·s-1] C Concentration [ppm] CFC Chlorofluorocarbons d Interelectrode distance [m] D Diameter [m] DBD Dielectric barrier discharge DC Direct current DCAC Dichloroacetylchloride ɛ Porosity E Electric field [V·m-1] Ea Activation energy [J·mol-1] ED Energy density [J·m-3] Es Energy supplied to the plasma [J] f Synergy factor FT-IR Fourier transform infrared spectroscopy h Planck’s constant [J·s] I Current [A] IPC In-plasma catalysis λ Wavelength [cm] k Reaction constant [depends on reaction order] L Length [m] m/z Mass to charge ratio [kg·C-1] MS Mass spectrometry Ƞ Removal efficiency [%] N The number of cathode pins NMVOCs Non-methane volatile organic compounds NTP Non-thermal plasma OMS Octahydral molecular sieve 𝜌 Density [kg·m3] ∆𝑃 Pressure drop [Pa] Pel Electric power supplied to the plasma [J·s-1] PPC Post plasma-catalytic ppm Parts per million Q Gas flow rate [m3·s-1] R Resistor [Ω] RH Relative humidity [%] S Selectivity [%] SD Surface discharge SEM Scanning electron microscope SMF Sintered metal fibers T Transmittance [%] TCAA Trichloroacetaldehyde TCE Trichloroethylene µ Viscosity [Pa·s] U Voltage [V] UCCS Unité de Catalyse et de Chimie du Solide UV Ultraviolet v Velocity [m·s-1] 𝜈̅ Wavenumber [cm-1] V Reactor volume [m3] VOCs Volatile organic compounds Von Onset voltage for the corona discharge [V] 1 Preface Problem statement The Industrial Revolution, which took place from the 18th to 19th centuries, led to a shift from handcrafted products to powered, special-purpose machinery, factories and mass production. This booming industrialization brought about a greater volume and variety of factory-produced goods and raised the standard of living for many people. However, the negative side of the story is the worrying impact of the industry on the environment. Environmental issues such as global warming, depletion of ozone and the formation of smog are strongly linked with the increasing industrialization. In addition, many industries emit waste gases that are harmful to human health. After World War II, the air pollution is tackled through legislation by introduction of emission standards. In addition, the media attention for these environmental problems caused a growing environmental awareness among the population, and stimulated the research on developing methods to reduce the emission of air pollutants. An important group of harmful air pollutants are volatile organic compounds (VOCs). These compounds are released from burning fuel (e.g. coal, natural gas, gasoline), solvents, paints, glues, etc. Commonly emitted VOCs are benzene, toluene, styrene, formaldehyde and trichloroethylene. Most of these compounds are toxic, even at low concentrations (< 200 ppm), and some may be carcinogenic. Conventional techniques used for end-of-pipe treatment of these VOCs are thermal oxidation, biological VOC removal, catalytic oxidation and adsorption. However, these techniques are only cost effective for the removal of high concentrated VOC gases. The increasingly strict legislation on the emission standards led to a growing demand for removal techniques of low concentrated VOC gases. A new innovative removal technique for pollutants can be found in the field of plasma physics: atmospheric non-thermal plasma (NTP). These so-called cold plasmas have proven to be more efficient than conventional techniques for the treatment of lightly contaminated waste gases, due to the lower energy consumption and its flexibility. The main advantage of NTP is that the supplied energy is used for the acceleration of electrons, instead of heating up the total gas volume. The energetic electrons collide with background molecules leading to the formation of reactive radical species, which in turn react with VOCs. The major drawback of the NTP removal technique is the formation of undesired by-products (e.g. ozone, NOx), which can be more harmful than the target VOC itself. However, the use of NTP in combination with a heterogeneous catalyst can significantly reduce the formation of by-products by oxidation of these compounds towards CO2, H2O, HX and X2 (with X being a halogen). 1 Objectives During this thesis, the abatement of trichloroethylene (TCE) in a post plasma-catalytic process is studied. Several parameters (gas flow rate, humidity, TCE concentration) are investigated and the performance of the TCE removal process is evaluated based on the TCE removal efficiency and the selectivity towards oxidation products (CO, CO2, HCl and Cl2). In the first part, the plasma reactor is characterized based on the reduced current-voltage curves. In addition, the production of ozone is monitored since this parameter determines the oxidative power of the plasma. After characterization of the plasma, TCE decomposition experiments are performed in a plasma-alone set-up. The degradation products of the abatement process are identified with FT-IR and MS spectrometry. The second part of this thesis focuses on the performance of the post plasma-catalytic process by placing a catalyst downstream of the plasma reactor. Three different catalysts are tested, namely CeO2, K-OMS-2 and Fe3O4/K-OMS-2. The K-OMS-2 type catalysts are prepared and characterized in cooperation with UCCS (Unité de Catalyse et de Chimie du Solide) from the university of Lille. The aim of the plasma-catalytic experiments is to increase the TCE removal efficiency and the selectivity toward oxidation products, while operating at low energy input conditions. 2 Part 1: LITERATURE REVIEW 3 2 Volatile organic compounds Definition Volatile organic compounds (VOCs) are a large and diverse class of rapidly evaporating compounds containing at least one carbon element and one or more other elements like hydrogen, nitrogen, oxygen, phosphor, silicium, sulfur and halogens. Methane, ethane, CO, CO2, organometallic compounds and organic acids are excluded from this definition. A measure of the volatility of a compound is the vapor pressure. This is the pressure exerted by a vapor in thermodynamic equilibrium with its condensed phase and depends on the temperature. A higher temperature will result in a higher vapor pressure. Gaseous compounds at room temperature have a vapor pressure which is higher than the atmospheric pressure (101.32 kPa). According to the ‘Solvent Emissions Directive’ [1], VOCs are defined as organic compounds having a vapor pressure of 0.01 kPa or more at 293.15 K, or a corresponding volatility under particular conditions of use. This directive defines the consumption and emission thresholds for industrial companies and describes existing VOC reduction technologies. Emissions of VOCs have to be minimized due to their negative effects on the environment and on human health, as illustrated in Figure 11. VOCs are toxic and have a negative impact on several phenomena such as ozone depletion, the formation of tropospheric ozone and the greenhouse effect. The reduction of the emissions of these pollutants is therefore very important and the emission standards are becoming stricter, thereby increasing the demand for VOC removal techniques. Figure 1. The impact of several air pollutants on environment and human health [2] 1 NMVOC = Non-Methane Volatile Organic Compounds 4 The largest source of VOCs is biogenic (1150 Tg C/year) and represents about 85 % of the total VOC emission. The majority is produced by plants, the main compounds being isoprene and terpene. The remaining VOC emission is due to anthropogenic activities (12 %, 161 Tg C/year) and vegetation fires (3 %, 50 Tg C/year) [3]. Major sources of anthropogenic VOCs are paints, protective coatings and solvents. Typical solvents are aliphatic hydrocarbons, glycol ethers and acetone. Traffic also contributes significantly to emissions of VOCs because of their presence in diesel and gasoline. Other examples of man-made VOC containing sources are detergents, perfume, glue and building materials [4]. Depending on the chemical structure, VOCs can be divided into different classes: aliphatic and olefinic compounds, chlorinated hydrocarbons, and aromatic hydrocarbons. Some common VOCs and their sources are listed in Table 1. Table 1. Overview of common VOCs and their sources [5] Group Compounds Applications Alkanes Methane, ethane, propane, butane, pentane Fuel for industrial and domestic heating, solvent Alkenes and alkynes Ethene, propene, butadiene, ethyne, propyne, butyne Basic compounds in the chemical industry (e.g. production of polymers ) Aldehydes Formaldehyde Adhesive, resin, insulation material, disinfectant Ketones Acetone, butanone, pentanone Solvent, detergent, plasticizer Alcohols Methanol, ethanol, propanol Solvent, fuel, disinfectant Ethers Diethyl ether Solvent, detergent Aromatic hydrocarbons Benzene, toluene, xylene, phenol Solvent, fuel, use in paint and ink Chlorinated hydrocarbons TCE, chloroform, vinyl chloride, dichlorobenzene Solvent, dry cleaning agent, degreasing agent Terpenes Sabinene, carotene Perfume, cosmetics, food additive A more commonly used classification divides VOCs in two groups: methane and non-methane VOCs (NMVOCs). The major sources of methane emissions are energy production (natural gas systems), agriculture (enteric fermentation), and waste management (decomposition of solid waste) [6]. The concentration of methane in the air is hundreds of times higher than that of other 5 VOCs, but the reactivity, expressed as ozone-forming ability, is 20 to 100 times lower. For this reason, a distinction is made between methane and NMVOCs. Trichloroethylene Trichloroethylene (TCE) is used as VOC during the experiments in this thesis to study the performance of the non-thermal plasma assisted catalytic process. The removal of TCE has been widely studied in literature [7-11]. The physical and chemical properties of TCE are illustrated in Table 2. Table 2. Physical and chemical properties of TCE [12] Trichloroethylene Molecular weight [g/mol] 131.4 Melting point [°C] -87.1 Boiling point [°C] 86.7 Density at 20°C [g/cm3] 1.46 Vapor pressure at 20 °C [kPa] 7.6 Viscosity at 20 °C [mPa·s] 0.58 Upper explosive limit in air [vol. %] 41 Lower explosive limit in air [vol. %] 11 Solubility in water at 20 °C [g/100 g water] 0.107 TCE is primarily used as a solvent in combination with adhesives, lubricants, paints, varnishes, paint strippers, pesticides and cold metal cleaners. It is used as an extraction solvent for greases, oils, fats, waxes and tars. The textile industry uses TCE to scour cotton, wool and other fabrics. It can also be used as a refrigerant for low temperature heat transfer [13]. The lifetime of TCE in the atmosphere is around four days. This is the time needed for the TCE concentration to decay to 37 % of its original value. A lifetime of four days is relatively short. However, TCE is continually released to the atmosphere. The major mechanism for TCE destruction in the atmosphere is reaction with hydroxyl radicals resulting in degradation products such as phosgene, dichloroacetylchloride, and formyl chloride [12]. 6 Exposure to moderate amounts of TCE causes headaches, tremors, and loss of balance. Larger exposures will cause dizziness or sleepiness, and may cause unconsciousness at very high levels. Very large exposures may cause irreversible cardiac problems, nerve and liver damage, and death. It is mildly irritating to the eyes, nose, and throat. Workers in TCE producing or using industries are at risk of exposure. Consumers can be exposed to TCE via air from production and processing facilities using TCE, or drinking water from contaminated water. The primary sources of TCE emissions are the industries that manufacture it or use it in production, such as the chemical industry, rubber manufacturers, the pharmaceutical industry, the semiconductor industry, heavy equipment manufacturing, iron and steel manufacturing, pulp and paper manufacture (for de-inking paper), the manufacturers of paints, inks, varnishes and lacquers, and the manufacture of pens, pencils, art and office supplies [13]. The permissible exposure limit for TCE is 50 ppm [14]. Removal techniques for VOCs There are several techniques including physical, chemical and biological treatments available to remove harmful VOCs by either recovery or destruction. Table 3 compares the various available VOC removal technologies. Each technology has its own applicability depending upon the type, concentration and gas velocity of the VOCs. The most important removal techniques and applications will be briefly discussed. 7 Table 3. Current VOC removal techniques 2.3.1 Thermal oxidation In a thermal oxidizer, VOCs are oxidized by combustion to CO2 and H2O. In the case of chlorinated compounds and in the presence of impurities, a number of by-products will also be formed such as HCl and Cl2 [15]. Thermal oxidation units consist of single chambers with ceramic refractory walls, equipped with a propane or natural gas burner and a stack. The oxidation occurs at temperatures between 800 and 1000 °C and a gas stream residence time up to 2 seconds. A thermal oxidizer can handle streams with a VOC concentration between 10 to 10000 ppm while removal efficiencies between 95 – 99 % can be reached. 8 One of the limitations of thermal oxidizers is the large amount of fuel required to heat up the gas stream to the temperature necessary for high-efficiency VOC destruction. However, the newest thermal oxidizers make use of heat exchangers to recover part of the heat. These units are called regenerative thermal oxidizers (Figure 2), because of their higher thermal efficiency. Figure 2. Working principle of a recuperative thermal oxidation unit [16] 2.3.2 Catalytic oxidation Catalysts are able to reduce the activation energy for oxidizing VOCs and thereby lowering the required reaction temperature. By using a catalyst, only one third of the energy is needed compared to thermal oxidation. For chlorinated compounds, catalysts such as chrome, aluminum, cobalt oxide and copper oxide/manganese oxide are used. The main disadvantage of the use of catalysts is their sensitivity towards impurities which deactivate the catalyst. Spent catalyst which cannot be regenerated needs to be disposed. The removal efficiency of a catalytic oxidizer is lower compared to a thermal oxidizer [17]. 2.3.3 Biological VOC removal Biological gas treatment techniques have been used as alternatives for the traditional physicalchemical techniques. VOCs diffuse through a membrane and come into contact with microorganisms in a biofilm which is attached onto the membrane. Through oxidative and reductive reactions, the VOCs are converted to carbon dioxide, water and organic biomass. Biological VOC treatment is environmentally friendly and cost effective. Another advantage of a membrane bioreactor is the possibility to separate the gas and liquid phases. In this way the conditions of both phases can be optimized much more easily [18]. 2.3.4 Adsorption In air pollution control, adsorption can be used to remove low to medium VOC concentrated streams. VOC molecules pass through a bed of solid particles and are held there by attractive london dispersion forces. The adsorptive capacity of the solid increases with the gas phase 9 concentration, molecular weight, diffusivity, polarity, and boiling point [19]. Common used solids in adsorption processes are zeolites, activated carbon and polymers. 2.3.5 Upcoming removal methods The traditional methods of VOC removal have several technical and economic disadvantages, especially for the removal of low concentrated VOC streams. In order to overcome these disadvantages, new technologies such as photo-catalysis and plasma technology have been developed. In this thesis, non-thermal plasma will be used to remove TCE in air and will be discussed in more detail. 10 3 Plasma technology Definition The term plasma was first introduced in 1929 by Langmuir and Tonks [20] to describe a group of charged particles in their studies about oscillations in the inner region of an electrical discharge. Later, this definition was broadened to define a state of matter : ‘the fourth state of matter’ [21]. When adding sufficient energy to a gas, the negatively charged electrons which are strongly attracted to the positively charged nucleus of the gas atoms will overcome the pull of the nucleus. The electrons are completely separated from the atoms and therefore have entire freedom of movement. If atoms or molecules have lost one or more electrons they carry positive charge outwardly and they become positive ions. Plasma is therefore considered as gas showing collective behavior and consisting of particles which carry positive and negative charges, in the extent that the overall charge comes to zero [22]. Plasma is widely used in practice and offer three major features that are attractive for applications in chemistry and technology [23]: 1. The temperature of the plasma components and energy density can significantly exceed those of conventional chemical technologies. 2. Very high concentrations of energetic and chemically active species (e.g. ions, radicals, electrons, excited states, and photons) can be produced in plasmas. 3. Plasma systems can be far from thermodynamic equilibrium, providing very high concentrations of active species while keeping bulk temperature as low as room temperature. Plasmas are used in several fields of application, such as extractive metallurgy, surface treatment, etching in microelectronics, metal cutting and welding, and fluorescent/luminescent lamps. Thermal and non-thermal plasma Depending on the conditions and amount of energy applied, a plasma discharge can be either thermal or non-thermal. Thermal plasmas are characterized by the fact that all plasma components are in thermal equilibrium. In non-thermal plasmas, there is a temperature difference between electrons and the other plasma components. (Non)-thermal plasmas can be generated by applying a voltage (DC, AC, pulsed) between two electrodes located at a certain distance from each other. The power source generates an electric field and donates energy to the free electrons present in the plasma volume. The accelerated electrons collide with heavy particles, but only lose a small portion of their energy (electrons 11 are much lighter than heavy particles). That is the reason why the electron temperature is initially higher than that of the heavy particles. Depending on the collision frequency and transferred energy the temperature difference between electrons and heavy particles can approach each other. This temperature difference is proportional to the square of the ratio of the electric field (E) to the pressure (p). Only in the case of small E/p ratios electrons and heavy particles reach thermal equilibrium. This kind of plasma is called a thermal plasma (TP) but will not be discussed any further because this is beyond the scope of this study. Numerous plasmas are far from the thermodynamic equilibrium and the plasma particles have different temperatures. Due to insufficient energy transfer from electrons to heavy particles, the electron temperature often significantly exceeds that of the heavy particles. In such nonequilibrium plasmas, ionization and chemical reactions are directly determined by electron temperature and are not so sensitive to thermal processes and the gas temperature. This kind of plasma is called non-thermal plasma (NTP) [23]. The generation of a NTP consists of many elementary processes which can be divided into primary and secondary processes. These processes and their timescales are summarized in Figure 3. Figure 3. Timescale events of the elementary processes in a non-thermal plasma [24] The primary process includes charge transfer, ionization, excitation, and dissociation with typical timescales between 10-15 and 10-8 seconds. The main primary processes are electron collisions with bulk gas molecules (N2, O2, H2O) resulting in the production of ionized and excited molecules. The primary processes are shown below. 𝑒 − + 𝑁2 → 𝑒 − + 𝑁 + 𝑁 (1) 12 𝑒 − + 𝑁2 → 𝑒 − + 𝑁 + + 𝑁 (2) 𝑒 − + 𝑂2 → 𝑒 − + 𝑂(3 𝑃) + 𝑂(3 𝑃) (3) 𝑒 − + 𝑂2 → 𝑒 − + 𝑂(3 𝑃) + 𝑂(1 𝐷) (4) 𝑒 − + 𝑂2 → 2𝑒 − + 𝑂+ + 𝑂 (5) 𝑒 − + 𝐻2 𝑂 → 𝑒 − + 𝐻 + 𝑂𝐻 (6) 𝑒 − + 𝐻2 𝑂 → 2𝑒 − + 𝐻 + + 𝑂𝐻 (7) The secondary process is the subsequent chemical reaction between the products of primary processes (electrons, radicals, ions, and excited molecules). Additional radicals and reactive molecules (O3, HO2, and H2O2) are also formed by radical and recombination reactions. The timescale of the secondary processes is around 10-3 seconds. A more detailed description of the occurring plasma reactions in TCE polluted air will be discussed later. Non-thermal plasma techniques are economically attractive alternatives for conventional air cleaning techniques due to the low energy consumption and high flexibility. In the non-thermal plasma, the majority of the discharge energy goes into the production of energetic electrons, rather than heating up the heavy particles (ions, radicals). Radicals produced during primary and secondary processes are able to react with the pollutant molecules present in the air. The aim is to convert these pollutants into less harmful oxidation products such as CO2 and H2O. Characterization parameters of VOC abatement There are several parameters which characterize the removal process of VOCs by using a NTP. The performance of the VOC abatement can be determined based on the following parameters: reduced electric field, energy density, removal efficiency, and COx selectivity. 3.3.1 Reduced electric field The electric field E is the ratio of the voltage across the plasma to the distance between the electrodes, and is given by E= with Upl d E Electric field [V·m-1] Upl Voltage over the plasma [V] d Interelectrode distance [m] (8) 13 The reduced electric field strength is a measure of the electron energy in the plasma, and is the ratio of the electric field E to the gas density N, given by Upl E = N N∙d with N (9) Gas density [molecules·m-3] The physical unit of the reduced electric field is the Townsend: 1 Td = 10−21 V∙m-2 3.3.2 Energy density The energy density (ED) expresses the amount of energy delivered to the gas to be treated per unit of volume, and is defined as the applied electric power divided by the gas flow rate: ℇ= with E𝑠 P𝑒𝑙 = V 𝑄 Es Energy supplied to the plasma [J] ℇ Energy density [J·m-3] V Reactor volume [m3] Pel Electric power supplied to the plasma [J·s-1] Q Gas flow rate [m3·s-1] ( 10 ) In this work, J·L-1 will be used as unit for the energy density. When the current and voltage over the plasma are constant during the discharges, the electric power can be calculated as Pel = Upl · Ipl with Upl Voltage over the plasma [V] Ipl Current through the plasma [A] ( 11 ) 3.3.3 Removal efficiency The removal efficiency indicates the relative amount of VOC which is removed from the treated gas stream, and can be calculated as follows: Ƞ = (1 − CVOC,out ) · 100 CVOC,in ( 12 ) 14 with η Removal efficiency [%] CVOC,in Inlet VOC concentration [ppm] CVOC,out Outlet VOC concentration [ppm] 3.3.4 CO, CO2 and COx selectivity The oxidizing power of a plasma can be determined by the CO and CO2 selectivity. The COx selectivity is the sum of the CO and CO2 selectivity. The selectivities are defined as SCO = SCO2 = CCO η · CVOC,in · 2 · 100 CCO2 · 100 η · CVOC,in · 2 SCOx = SCO + SCO2 with 𝑆𝐶𝑂 , 𝑆𝐶𝑂2 , 𝑆𝐶𝑂𝑥 CO, CO2, COx selectivity [%] 𝐶𝐶𝑂 , 𝐶𝐶𝑂2 Outlet CO, CO2 concentration [ppm] CVOC,in VOC inlet concentration [ppm] η Removal efficiency [%] ( 13 ) ( 14 ) ( 15 ) One of the goals of the TCE removal experiments, performed in this thesis, is to maximize the COx selectivity and to minimize the formation of hazardous by-products. Discharge types in NTP The classification of discharges that can occur in NTP is extensive and depends on the following parameters [25]: - Type of power supply: AC, DC, pulsed - Electrode configuration - Voltage level - Pressure An overview is given of the different discharge types based on the power source. Within this classification the most relevant reactor technologies are described. 15 3.4.1 DC discharges In this thesis, the TCE abatement experiments were performed with a DC power source. Therefore, DC discharges will be described in detail. Three types of discharges can occur in plasma generated by a DC power source: DC corona discharge, DC glow discharge and spark discharge. The type of discharge depends on the applied voltage over the plasma and the current. The different discharge regimes can be distinguished from each other when looking to the reduced volt-ampere characteristic, which presents the relationship between plasma voltage (V) and reduced current (I/V). A typical reduced volt-ampere characteristic is illustrated in Figure 4. Figure 4. Reduced volt-ampere characteristic for a negative pin-to-plate discharge in ambient air [26] DC corona discharge Corona discharges are relatively low power electrical discharges that take place at or near atmospheric pressure. The corona is invariably generated by strong electric fields associated with small diameter needles, wires, or sharp edges on an electrode. The corona appears as a faint filamentary discharge radiating outward from the discharge electrode [27]. This kind of discharge is self-sustained and no external energy other than the electrical energy is needed to sustain the gas ionization and to maintain the current flow [28]. In the corona regime the discharge current I and the interelectrode voltage V are related through the following relation, given by Townsend [29]: 16 I = C V (V − Von ) ( 16 ) where Von is the onset voltage for the corona discharge and C is a factor which depends on the electron mobility and inter-electrode distance. This linear relationship is visible in the reduced volt-ampere characteristic (Figure 4). Corona discharges can be operated both in positive as negative polarity and have certain mechanisms in common. Both corona discharges are initiated by the acceleration of electrons in the electric field generated by the DC power source. Accelerated electrons collide with gas molecules resulting in electron/positive-ion pairs, which in turn undergo different processes creating an electron avalanche which sustains the corona discharge. The ionization processes occurring in positive and negative corona discharges are illustrated in Figure 5. Figure 5. Scheme of the ionization processes in positive and negative DC corona discharges [24] - Positive DC corona discharge Two regions can be distinguished in the interelectrode space of the positive DC corona: plasma region and unipolar region. In the plasma region, electron-positive ion pairs (O2+, N2+) are produced by collision with accelerated electrons. These ion pairs release new electrons, which are accelerated again. This resulting electron avalanche sustains the corona discharge and is called a Townsend avalanche, named after John Sealy Townsend, who discovered this fundamental ionization mechanism. Next to ionization processes, energetic electrons also trigger dissociation and excitation processes, producing other reactive species, such as radicals and excited molecules. In the unipolar region, the electric field is too weak to produce secondary electrons and the positive ions migrate towards the negative electrode. An increasing electric 17 field strength results in the production of more electrons and expands the plasma region. If the number of electrons reaches a critical value, a thin weakly ionized plasma channel (streamers) will be formed. These streamer discharges have a higher efficiency in the production of chemical active species. Satoh et al. [30] investigated the decomposition of benzene in a positive DC corona discharge between multi-pin and plane electrodes at atmospheric pressure, and obtained CO2 as main degradation product. Zhang et al. [31] compared styrene removal in air by positive and negative DC corona discharges, and reported that positive corona discharges were more effective. - Negative DC corona discharge When the sharp electrode is negatively polarized, this is called a negative corona discharge. One of the differences in comparison to a positive corona discharge is the presence of three regions in the interelectrode space of a negative corona discharge: inner plasma region, intermediate plasma region and unipolar region. Just like in a positive corona discharge, electron impact ionization processes produce positive ion pairs (O2+, N2+) and additional electrons in the inner plasma region. The electron energy values decrease while electrons move towards the intermediate plasma region. The positive ions move back towards the negative polarized electrode and hit its surface. This results in a secondary electron emission. In the intermediate region, electrons are combined with neutral molecules, producing negative ions. The energy levels in this region are too low to cause further ionization reactions, but the presence of positive and negative polarized species are able to trigger certain plasma reactions. In the outer region, only a flow of negative ions and free electrons move towards the positive electrode. Positive and negative DC corona discharges possess a small active plasma volume and are therefore not very suitable for the production of large quantities of chemical particles. The applications of corona discharges are largely confined to electrostatic precipitation and photocopy machines. DC glow discharge When increasing the plasma voltage in a corona discharge, the density of the electrons and the electric field in the interelectrode space will both increase. Hence, when the electric field becomes sufficiently high to produce intense gas ionization, the whole gap will be filled with plasma and the corona discharge will go over to the regime of a glow discharge. When looking at the glow discharge region in the reduced volt-ampere characteristic, it can be seen that the current increases with voltage more sharply in comparison with the corona regime. This can be explained by the increasing role of ionization which increases the conductivity in the interelectrode space of the glow discharge [32]. It was thought for many years that a glow discharge could only exist at low pressures (1 to 104 Pa). With increasing plasma voltage at atmospheric pressure, a negative corona discharge will quickly turn in a spark discharge due to local charge build-up on the anode which makes the plasma becoming unstable. These sparks have to be avoided in order to protect the equipment. 18 Recently, several researchers have experimentally proven that glow discharges can also exist at atmospheric pressure [33-36]. The glow discharges were generated by using stabilization techniques to reduce the charge density on the anode which delays the spark discharge regime [26, 37-39]. Callebaut et al. [26] intensively studied DC glow discharges and implemented the following techniques to achieve a luminous glow discharge: (1) a fast gas flow. A gas flow with a velocity higher than 10 meters per second is able to blow away local charge accumulations, which delays the spark regime. (2) Optimization of the electrode geometry. By applying a hollow cylindrical pin as cathode, the current will be better spread over the entire cathode, and blocks the formation of sparks. A spherical crater anode instead of an anode plate leads to a more uniform distribution of the current density over the spherical parts of the anode surface. This geometry is able to reduce local charge accumulation. Glow discharges are most suitable for the removal of VOCs within the DC discharges. The entire space between anode and cathode is filled with plasma, which ensures that the entire VOC-laden air stream comes into contact with the reactive plasma species. Furthermore, the current density in a glow discharge is much higher than in a corona discharge providing a high reactivity. Multi-pin-to-plate electrode systems for the generation of glow discharges were successfully tested for air treatment applications [11, 37], and will also be used in this work for the removal of TCE. Spark discharge At a critical voltage, a glow discharge will be transferred to a spark discharge. A spark is accompanied by a sharp splash in current up to several amperes. This high current can cause damage to the electrodes due to local thermal heating, which is the reason why spark discharges cannot be used for the removal of VOCs. 3.4.2 AC discharges Discharge generation using AC voltage is also possible, and covers a wide range of reactor technologies. The most important AC discharges are described. Dielectric barrier discharge (DBD) Dielectric barrier discharges (DBD) are the most frequently used discharges to generate NTP for VOC abatement experiments [40-44]. This kind of discharge is characterized by the presence of one or more insulating layers (e.g. quartz, ceramic, glass), called the dielectric barrier, which are located between the electrodes. DBDs are generally operated in a planar (onesided or two-sided) or cylindrical configuration, as shown in Figure 6. An interesting property of DBDs is the formation of current filaments or microdischarges, occurring when the local electron density in the discharge reaches a critical value. A microdischarge that reaches the dielectric spreads into a surface discharge covering a region much larger than the original channel diameter. Due to charge build up on the dielectric, the electric field at the location of a microdischarge is reduced and thus terminating the current flow at this location. The use of a dielectric barrier has two functions: (1) limiting the amount of charge deposited in a microdischarge, thus preventing it from transitioning into a spark discharge, and (2) distributing 19 the microdischarges over the entire electrode surface which increases the probability of collisions between bulk gas molecules and electrons [45]. Subrahmanyam et al. [44] developed a novel DBD reactor in which a metallic catalyst serves as the inner electrode. The catalytic electrode was prepared by deposition of MnOx and CoOx on sintered metal fibers (SMF) in the form of a cylindrical tube. This reactor showed complete conversion and a selectivity of 80 % to total oxidation products (H2O and CO2) at relative low energy input (235 J·L-1) during the destruction of toluene (100 ppm) in air. (a) (b) Figure 6: Planar (a) and cylindrical (b) DBD configurations [45] Surface discharge A surface discharge (SD) reactor is similar to a DBD reactor due to the presence of a dielectric barrier. This type of reactor contains a series of strip electrodes attached on the surface of a high purity layer (e.g. alumina, ceramic). A planar or cylindrical induction electrode is embedded in its inside, facing to the discharge electrodes. A surface discharge reactor configuration is presented in Figure 7. When applying a medium frequency (8-15 kHz), medium-high AC voltage (4-6 kV peak), surface discharges are generated from the peripheral edges of each discharge electrode and stretches out along the surface layer. The role of the induction electrode is to enhance the length of these streamers by providing the streamer tips with the tangential field of adequate intensity at any instant during its development. This means that long streamers can be generated along the surface layer with a lower voltage. Masuda et al. developed a surface discharge reactor composed of a high-purity alumina ceramic layer for the abatement of VOCs [46] and CFC [47], and for the application as ozoniser [48]. More applications of surface discharge reactors for the abatement of VOCs can be found in literature [49, 50]. 20 Figure 7: Planar surface discharge configuration [25] Ferroelectric pellet packed-bed reactor When the discharge zone in a DBD reactor is filled with perovskite oxide pellets, the plasma reactor is called a ferroelectric pellet packed-bed reactor (Figure 8). Application of an AC voltage leads to polarization of the ferroelectric material and induces strong local electric fields at the contact points between pellets. These strong electric fields result in the production of partial discharges at the contact points between pellets and shift the electron distribution towards higher energies [51]. The high energetic electrons tend to form active species through electron-impact reactions (dissociation and ionization), rather than forming less useful species through rotational and vibrational excitation. This leads to higher energy efficiency because electron-impact reactions are mainly responsible for the decomposition of VOCs [25]. The main disadvantage of these packed-bed reactors is the pressure drop over the reactor due to the presence of the packing material. Several ferroelectric materials are proposed in literature for the abatement of VOCs: PbZrO3PbTiO3 [52], NaNO2 [53], BaTiO3 [53-55], CaTiO3, SrTiO3, MgTiO4, PbTiO3 [56]. Among these ferroelectric materials, BaTiO3 is widely most used due to its high dielectric constant (2000 < ε < 10000) [57]. However, the performance of BaTiO3 was recently investigated and compared with Ba0.8Sr0.2Zr0.1Ti0.9O3 as a special type of modified ferroelectric material for the removal of toluene. The highest removal efficiency of toluene was 98 % with Ba0.8Sr0.2Zr0.1Ti0.9O3 as packing material, and was 16 % higher than with BaTiO3 [58]. 21 Figure 8: Geometries of packed bed discharges: (a) planar configuration and (b) coaxial configuration [59] 3.4.3 Pulsed corona discharge A pulsed corona discharge applies a pulsed power supply, of which the typical waveforms of the pulse voltage and discharge current are shown in Figure 9. The duration of a typical pulse is less than 1 µs and the rise time is about tens of nanoseconds. There are two reasons to apply such short pulse duration: (1) to prevent spark formation which can damage the reactor and decreases the process efficiency, (2) to minimize the energy dissipation by ions which decreases the energy efficiency. Figure 9: Typical waveforms of pulse voltage and discharge current in pulsed corona discharges [60] There are three main types of pulsed corona discharge reactors, depending on the used type of electrode: point-to-plate, wire-to-plate and wire-to-cylinder [61]. Koh and Park [62] suggest to use a wire-to-cylinder reactor due to the many advantages compared to the other electrode configurations. The open structure of the wire-to-cylinder reactor results in low pressure drop and the ability of space utilization that can be oriented in any position from horizontal to 22 vertical. A schematic representation of a wire-to-plate reactor containing a dielectric between the electrodes is illustrated in Figure 10. Figure 10: Schematic of a pulsed corona reactor (wire-to-plate configuration) [25] TCE abatement in NTP Before performing TCE abatement experiments, it is important to get insight in the underlying mechanisms and reactions that enable the removal of TCE. A better understanding of the removal process can yield measures to improve the removal efficiency and COx selectivity. The destruction of TCE with NTP takes place through many possible pathways [63]. The first possible pathway is the electron attachment of TCE, leading to the formation of C2HCl2 and a chlorine anion: C2 HCl3 + e− → C2 HCl2 + Cl− k = 1.5 · 10−13 cm3 molecule−1 s−1 ( 17 ) The contribution of the electron attachment of TCE depends on the electron density in the plasma discharge. In corona discharges (low electron density), this contribution will be significantly lower as in dielectric barrier discharges (high electron density). Another pathway is the dissociation of TCE by reaction with atomic oxygen leading to the formation of different by-products: C2 HCl3 + O → CHOCl + CCl2 k = 5.7 · 10−13 cm3 molecules −1 s −1 ( 18 ) C2 HCl3 + O → COCl + CHCl2 k = 8.7 · 10−14 cm3 molecules −1 s −1 ( 19 ) C2 HCl3 + O → C2 Cl3 + OH k = 6.3 · 10−15 cm3 molecules −1 s−1 ( 20 ) The rate coefficients of the dissociation reactions with O are in the same order of magnitude as for the electron attachment of TCE. However, atomic oxygen has a longer lifetime than the electrons which increases the probability of reaction with atomic oxygen. 23 When the TCE removal process takes place in humid air, the TCE dissociation can also occur by reaction with hydroxyl radicals: C2 HCl3 + OH → CHCl2 + CHOCl k = 3.1 · 10−13 cm3 molecules −1 s −1 ( 21 ) C2 HCl3 + OH → C2 Cl3 + H2 O k = 1.9 · 10−12 cm3 molecules −1 s−1 ( 22 ) C2 HCl3 + OH → C2 HCl2 OH + Cl k = 2.4 · 10−13 cm3 molecules −1 s−1 ( 23 ) C2 HCl3 + OH → CHCl2 COCl + H k = 2.4 · 10−14 cm3 molecules −1 s−1 ( 24 ) The actual rates of the dissociation reactions again depend on the densities of the reactants, so a higher humidity will result in a higher contribution of the dissociation reactions with hydroxyl radicals. There is also a possibility that TCE is decomposed by radicals produced by earlier occurred decomposition reactions with TCE: C2 HCl3 + ClO → CHCl2 + COCl2 k = 3.1 · 10−12 cm3 molecules −1 s−1 ( 25 ) C2 HCl3 + Cl → C2 Cl3 + HCl k = 7.3 · 10−16 cm3 molecules −1 s−1 ( 26 ) The rate coefficient of reaction (25) is one order of magnitude higher than the previous reactions. The density of ClO will be low at the beginning of the destruction process and the reaction will not significantly contribute to the removal of TCE. However during the removal process the Cl and ClO densities will rapidly increase, resulting in a high contribution of the reactions (25) and (26) to the removal of TCE. Another pathway is the dissociation by metastable nitrogen molecules. These molecules are dominant dissociation species occurring in a NTP destruction process of an air polluted stream. However, no reaction rate coefficients have been found in literature. The reactions discussed above are not the only reactions that take place in the TCE abatement process. Next to the electrons and radicals typically produced in air, a lot of by-products will be formed during the removal process. Some of these by-products are able to further react with TCE. An example of a by-product that will further react with TCE is CHCl2: C2 HCl3 + CHCl2 → CHCl3 + C2 HCl2 ( 27 ) Based on the TCE destruction processes discussed above, the presence of the most frequently occurring degradation products such as trichloroacetaldehyde (TCAA), phosgene (COCl 2), dichloroacetylchloride (DCAC), HCl and Cl2 can be explained. 24 Ozone formation in NTP Another by-product formed during removal processes of air polluted streams in NTP is ozone. Schönbein first identified the substance ozone during his electrolysis experiments with acidified water in 1840. 17 years later, Werner designed the first ozone generator, in which ozone was produced by the generation of electrical discharges in air at atmospheric pressure [64]. Ozone is toxic and has led to stringent regulations for ambient concentration standards for levels in workplace, and limits for devices that produce ozone. Ozone is produced by devices like laser printers, copiers, and electronic air cleaners. These applications rely on atmospheric corona discharges. On the other hand, ozone is also used as disinfectant in water treatment plants because of its strong oxidative character. In these applications, ozone is mostly produced at high rates in dielectric barrier discharges in pure oxygen [65]. The ozone formation in gas discharges is initiated by the dissociation of O2 molecules by electron impact reactions. The formed atomic oxygen undergoes a three-body recombination reaction with O2, producing O3: 𝑂2 + 𝑒 − → 2O + 𝑒 − ( 28 ) 𝑂 + 𝑂2 + 𝑀 → 𝑂3 + 𝑀 ( 29 ) In reaction (29), M is a third collision partner needed in order to absorb excess energy. Next to oxygen, nitrogen also plays an important role in the generation of ozone. A part of the ozone formed in discharges results from processes with excited molecular states N2(A3∑) and N2(B3∏) [66-68]. The production of oxygen atoms in reaction (28) results in the disappearance of O3 by the following reaction: 𝑂 + 𝑂3 → 2𝑂2 ( 30 ) Morent and Leys [69] studied ozone generation in a DC glow discharge of a multi-pin-to-plate configuration and found out that the ozone concentration is directly proportional to current, space averaged reduced electric field, and residence time. The ozone production ability of a NTP is an important plasma parameter because it gives an indication to which extent the plasma is able to break down pollutants. Because of the toxic character of O3 and the formation of photochemical smog, the ozone concentration in the treated gas at the outlet of the plasma reactor has to be as low as possible. Researchers [44, 59, 70, 71] found out that ozone can be decomposed in a plasma reactor by applying a catalyst in combination with the plasma. This principle is called plasma catalysis and will be further discussed in the next chapter. 25 4 Plasma catalysis Definition The use of NTP as end-of-pipe technique for the removal of VOCs has not yet been industrially implemented due to several drawbacks of the technology. The main drawbacks are the poor energy efficiency, the formation of harmful by-products, and the low CO2 selectivity. To overcome these disadvantages, researchers are combining the advantages of NTP and catalysis in a technique called plasma catalysis [72-75]. By placing a catalyst inside or in close vicinity of the discharge zone, the retention time will be increased due to adsorption of the VOC molecules, favoring complete oxidation to CO2 and H2O. In many cases, a synergetic effect can be observed which is caused by various mechanisms [10, 76, 77]. In-plasma vs. post-plasma catalysis The combination of a NTP and a heterogeneous catalyst can be divided in two categories depending on the location of the catalyst: in-plasma catalysis (IPC) and post-plasma catalysis (PPC). IPC is a single stage process where the catalyst is placed inside of the active plasma, while PPC is a two-stage process where the catalyst is located downstream of the plasma reactor. The catalyst material can be introduced into the process in different ways: as a layer of catalyst material (pellets, granulates, coated fibers, powders), as a packed bed (pellets, granulates, coated fibers) or as a coating on the electrodes or reactor wall. 4.2.1 Plasma-catalyst interactions in IPC systems Many researchers reported the synergetic effect between plasma and catalyst, improving the VOC removal efficiency and leading to higher CO2 selectivity. Although the detailed mechanism is still unclear, the synergetic effect can be explained by the activation of the catalyst surface by plasma. Several mechanisms have been proposed in plasma-catalyst systems: UV, ozone, changes in work function, plasma-induced adsorption/desorption, local heating, activation of lattice oxygen, generation of electron-hole pairs and their subsequent reactions, direct interaction of gas-phase radicals with the catalyst surface and the adsorbed molecules etc. [78]. In an IPC configuration, both plasma and catalytic reactions take place simultaneously and interact with each other. The introduction of a catalyst into the plasma discharge will have an impact on the type of discharge. Microdischarges can be generated inside the catalyst pores, resulting in more discharge per volume and increasing the mean energy density of the discharge [79]. Moreover, insertion of ferroelectric pellets into the discharge zone leads to a shift in the 26 accelerated electron distribution. Ferroelectric materials are able to increase the electric field with a factor between 10 and 250, leading to a more oxidative discharge [51]. The presence of a heterogeneous catalyst in the plasma discharge also increases the production of reactive plasma species. Roland et al. [76] studied the oxidation mechanism of various organic substances immobilized on non-porous and porous carriers and concluded that the oxidizing species are formed in the pores of these porous carriers when exposed to NTP. Insertion of TiO2 in the discharge zone, studied by Chavadej et al. [80], leads to an acceleration of the formation of the superoxide radical anion O2- inhibiting recombination processes and increasing the total catalytic activity. On the other hand, introduction of a catalyst in the plasma can inhibit the formation of ionic species [81]. However, this effect did not impair the catalyst’s role in reducing the emissions of ozone and carbon monoxide for this specific application: indoor pollution control. The reactive plasma species and electrons are able to trigger physical changes of the catalyst material. NTP enhances the dispersion of the catalyst particles and influences the stability and activity of the catalyst material. The oxidation state of the catalyst can also be influenced by exposure to a plasma discharge. This was studied by Guo et al. [82], who exposed a Mn2O3 catalyst to a NTP for 40 hours. After the experiment, Mn3O4 was detected which is characterized by its larger oxidation capability. Plasma exposure can also result in the enhancement of the specific surface area or in a change of the catalytic structure. By comparing SEM images of manganese oxide/alumina/nickel foam before and after discharge exposure (Figure 11), it can be seen that the granularity of the grain on the catalyst surface becomes smaller and the distribution becomes more uniform. Plasma exposure can even result in the formation of new types of active sites, such as Al-O-O* which is observed in the pores of Al2O3 in IPC experiments [83]. Figure 11. SEM images of manganese oxide/alumina/nickel foam (a) before and (b) after DBD [82] The physical changes of a catalyst material when exposed to a NTP have an influence on the adsorption of VOCs on the catalyst surface. Adsorption increases the retention time of the VOCs and the interaction between short-lived plasma species (e.g. O(3P), O(1D), N(4S), OH*, HO2*) with adsorbed VOC molecules leads to a more complete oxidation. Kim et al. [84] 27 reported that an IPC system shows zeroth-order kinetics, indicating the importance of surface reactions in the decomposition of VOCs. The presence of water during decomposition processes has to be avoided, because the adsorption of water results in a decrease of the reaction probability of the VOC with the surface and therefore reduces the catalyst activity [85]. 4.2.2 Plasma-catalyst interactions in PPC systems In a PPC configuration, plasma does not directly interact with the catalyst because the reactive species produced in the discharge zone disappear before they reach the catalyst surface due to the short lifetime of the species. However, not only short-living unstable reactive species are produced in plasma discharges, a fraction recombines to form more stable species such as ozone. Because of the higher lifetime, ozone is able to reach the catalyst surface positioned downstream of the plasma discharge. If a suitable catalyst is employed, ozone can dissociatively adsorb onto the catalyst surface forming molecular and reactive atomic oxygen. The latter species enhance the oxidation of remaining VOCs and unwanted by-products. This leads to an improved energy efficiency and COx selectivity, and also reduces the emission of harmful ozone into the air. The main advantage of a PPC configuration is that the plasma can convert the VOCs into products which are easier to oxidize by the catalyst than the VOCs itself. Common used catalysts A lot of catalysts have been proposed in literature to enhance the removal of VOCs. By applying a combination of several catalysts in the same system, the features of these catalysts can be combined to enhance the removal of VOCs. The most studied catalysts are metal oxides and zeolites, which will be discussed here. 4.3.1 MnO2 based catalysts Manganese dioxide (MnO2) is a p-type oxide semiconductor and is common used in plasmacatalysis because of its ability to easily decompose ozone. This is due to some specific properties of MnO2, such as the ease of synthesizing crystalline phases and the mobility of oxygen in the crystal lattice which is able to create vacancies and promote the formation of oxygen groups at the catalyst surface [86, 87]. Several researchers have investigated the removal of VOCs in a NTP combined with MnO2. Einaga and Futamura [88] studied the decomposition of benzene on MnO2. They reported that ozone, produced in the plasma discharge, is decomposed on MnO2 to O2 and is able to oxidize benzene to form oxygencontaining by-products. These by-products are further oxidized to CO2 and CO. Futamura and Gurusamy [89] observed synergetic effects for the decomposition of fluorinated hydrocarbons with dielectric barrier discharge reactors filled with MnO2. Jarrige and Vervisch [90], who coupled a fixed bed of MnO2/Al2O3 with a pulsed corona discharge for the removal of propane, observed complete decomposition of ozone at ambient temperature. The produced oxygen species further oxidize propane which leads to a greatly enhanced conversion and CO2 selectivity. Li et al. [91] investigated MnO2 catalysts with different phase structures, supported 28 on Al2O3 pellets, and applied in a post plasma-catalysis system for the removal of acetaldehyde. An improved acetaldehyde removal efficiency and CO2 selectivity was observed, while the formation of ozone and NOx in plasma was inhibited. 4.3.2 Al2O3 based catalysts Aluminum dioxide (Al2O3), which is commonly called alumina, can exist in several phases of which α-Al2O3 and ϒ-Al2O3 are most used in plasma catalysis. Vandenbroucke et al. [11] observed synergetic effects by applying Pd(0.05 wt%)/ϒ-Al2O3 downstream of the plasma reactor for the removal of TCE. Song et al. [92] compared the removal rates of VOCs (toluene and propane) in a NTP and an IPC system with ϒ-Al2O3. The experimental results showed that the removal rates of VOCs increase when exposing ϒ-Al2O3 to a NTP. This can be explained by the longer residence time of the VOCs in the plasma reactor due to the adsorption on the catalyst surface. Al2O3 is also able to suppress the formation of by-products during the VOC abatement. This phenomenon was observed by Ogata et al. [93], who compared the abatement of benzene in a conventional reactor packed with BaTiO3 pellets and an Al2O3 hybrid reactor packed with a mixture of Al2O3 and BaTiO3 pellets. The Al2O3 hybrid reactor resulted in a higher selectivity towards CO2 and the presence of the Al2O3 pellets suppressed the formation of N2O. 4.3.3 TiO2 based catalysts Titanium dioxide (TiO2) is a photocatalyst, which means that the catalyst can be activated by irradiation with light of a particular wavelength. In the case of TiO2, UV light with a wavelength of 388 nm is required to activate the catalyst. UV radiation is emitted by electronically excited species produced by streamer discharges in air. Morent et al. [10] compared the removal efficiency for TCE in a hybrid plasma-catalyst system consisting of a pin-to-mesh positive corona discharge containing TiO2 pellets with the same system without catalyst. The presence of TiO2 enhanced the TCE decomposition resulting in a maximum removal fraction of 85 % at an energy density of 600 J·L-1 and 100 ppm TCE at the inlet. The oxygen partial pressuredependent behavior of catalysts TiO2, γ-Al2O3 and zeolites was evaluated by Kim et al. [78], based on their enhancement factor and adsorption capability for the total oxidation of benzene. The increase of the partial pressure of O2 enhanced both the removal efficiency of benzene as well as the CO2 selectivity, regardless of the type of catalyst used. However, the TiO2 catalyst showed the largest enhancement factor (100). Park et al. [94] investigated benzene decomposition in a DBD-catalyst hybrid system. The following catalysts were studied and attached on a glass barrier in the DBD plasma reactor: TiO2, Pt/TiO2 and V2O5/TiO2. The V2O5/TiO2 catalyst hybrid system was most effective in decomposing benzene and controlling by-products such as CO, CO2 and N2O. 4.3.4 Zeolites Next to metal oxides, many studies have focused on the use of zeolites to improve the performance of NTP systems. Ogata et al. [95] compared the performance of four types of zeolites in a zeolite-hybrid plasma reactor for the decomposition of toluene. The major 29 synergetic effect in the zeolite-hybrid plasma reactor occurred from the decomposition of toluene adsorbed in the internal area of the zeolite by active oxygen species. Kim et al. [96] studied the use of various zeolites in a flow-type IPC reactor and proved that the support of Ag nanoparticles enhanced both the catalytic activity and the expansion of plasma area on the catalyst surface. Intriago et al. [97] showed that HY and H-ZSM-5 zeolites have important catalytic activity for dichloromethane oxidation due to the high density of strong acid sites which enhances the adsorption of hydrocarbons and catalytic activation of hydrocarbon halides. 30 5 Analytical techniques Infrared spectroscopy Infrared spectroscopy is the analysis of infrared light (IR) interacting with a molecule, and is used both to obtain the chemical structure of a compound and as an analytical tool to determine the concentration of a compound. IR refers to that part of the electromagnetic spectrum between the visible and microwave region, and is characterized by two parameters: wavelength λ and energy content E. Both parameters are related by the following formula: 𝐸= ℎ𝑐 λ ( 31 ) with ℎ = 6.63 ∙ 10−34 𝐽 ∙ 𝑠 (Planck’s constant) 𝑐 = 300 ∙ 108 𝑐𝑚 ∙ 𝑠 −1 (speed of light) IR spectra are mostly reported in cm-1, which refers to the unit of the wavenumber 𝜈̅ : 𝜈̅ = 1 λ ( 32 ) When the energy of the exposed IR radiation matches the energy of a specific molecular vibration, absorption occurs. Figure 12 shows an IR spectrum of formaldehyde. The wavenumber 𝜈̅ (cm-1) is plotted on the x-axis and is proportional to the energy. The transmittance T (%) is plotted on the Y-axis and is the ratio of the transmitted intensities for each wavelength with and without the sample. Figure 12: The IR spectrum of formaldehyde [98] 31 The wavenumbers at which a molecule absorbs radiation give information about functional groups present in the molecule. Certain groups of atoms absorb energy that give rise to bands around a specific wavenumber. The correlation between wavenumbers and functional groups are tabulated and can be used to analyze a certain spectrum. The wavenumbers of the IR radiation, absorbed by a molecule, are determined by the vibrational (and rotational) modes of that molecule. A molecule consisting of n atoms has a total of 3n degrees of freedom, corresponding to the Cartesian coordinates of each atom in the molecule. In a nonlinear molecule, 3 of these degrees are rotational, 3 are translational and the remaining corresponds to fundamental vibrations. There are two types of molecular vibrations: stretching and bending. H2O contains three fundamental vibrations, which are presented in Figure 13. Figure 13: Stretching and bending vibrational modes of water [99] If the frequency of the IR radiation corresponds to the frequency of a vibrational mode of the molecule, there is a net energy transfer which reduces the intensity of the radiation. Some molecules such as O2 and N2 are not able to absorb IR radiation. In order to be IR active, a vibration or rotation must cause a change in the dipole moment of the molecule. This change in dipole moment allows the alternating electric field of the IR radiation to interact with the molecule, and causes a change of the amplitude of one of these movements [99]. FT-IR spectrometer Until 1960, dispersive infrared spectrometers were used as standard analytical technique for organic compound characterization. However, this instrument showed a number of disadvantages: slow scanning speed, frequent calibration with external reference needed, and the occurrence of stray light. A new spectrometer has been developed to overcome the drawbacks of the dispersive spectrometer: Fourier transform infrared (FT-IR) spectrometer. Today, FT-IR spectroscopy is the standard for organic compound identification in modern analytical laboratories. A FT-IR spectrometer uses a Michelson interferometer to collect a spectrum, which is shown in Figure 14. The interferometer consists of an IR light source, beamsplitter, two mirrors, a laser and a detector. The IR beam coming from the source goes to the beamsplitter which splits the beam into two parts. One part is transmitted to a movable mirror, while the other part is reflected to a fixed mirror. The moving mirror moves back and forth at a constant velocity. The two beams are reflected from the mirrors and recombine at the beamsplitter. This recombination leads to an interference pattern, since the beam from the moving mirror has traveled a different distance than the beam from the fixed mirror. This interference pattern is called an 32 interferogram and goes from the beamsplitter to the sample, where an amount of energy is absorbed depending on the compounds in the sample. The transmitted beam reaches the detector and reads information about every wavelength in the IR range simultaneously. This detector signal is sent to a computer which performs a Fourier transform on the interferogram to convert it into an IR spectrum [100, 101]. Figure 14: The Michelson interferometer [101] Mass spectrometry Mass spectrometry is a powerful analytical technique used to identify and quantify (un)known compounds within a sample. The process involves the conversion of the sample into gaseous ions, with or without fragmentation, which are then characterized by their mass to charge ratios (m/z) and relative abundances. The different components of a mass spectrometer are illustrated in Figure 15: a sample inlet, an ionization source, a mass analyzer and an ion detector. Figure 15: Components of a Mass Spectrometer The first step in the mass spectrometric analysis of compounds is the generation of gas phase ions of the compound. Ions are generated by inducing either the loss or gain of a charge from a neutral species by cationization, deprotonation, electron ejection, electron capture, or by transferring a charged molecule from a condensed phase to the gas phase. An extraction system removes the produced ions from the sample, which are then trajected through a mass analyzer. The difference in mass of the fragments allows the mass analyzer to 33 sort the ions by their mass-to-charge ratio. Not all analyzers operate in the same way. Some analyzers separate ions in space (quadrupole, quadrupole ion trap, magnetic sector), while others separate ions by time (time-of-flight, time-of-flight reflectron, quad-time-of-flight). Once the ions are separated by the mass analyzer, they are sent to the ion detector. The most common used detector is the electron multiplier, which transfers the kinetic energy from the incident ions to a surface that in turn generates secondary electrons. The produced electrical signals are then transmitted to a computer that is able to construct the mass spectrum. A typical mass spectrum of TCE is presented in Figure 16. Figure 16: Mass spectrum of TCE [102] All mass spectrometers operate at vacuum conditions (13 · 10−5 to 13 · 10−7 Pa) to allow ions to reach the detector without colliding with other gaseous atoms and molecules. These collisions have to be avoided due to their negative impact on the resolution and sensitivity. High pressures may also cause high voltages to discharge that can damage the instrumentation, electronics, and the computer system running the mass spectrometer [103, 104]. 34 Part 2: EXPERIMENTAL STUDY 35 6 Materials and methods Experimental set-up A schematic diagram of the experimental set-up is shown in Figure 17, and can be divided into several sections. In the first section, the composition of the inlet gas is controlled by three mass flow controllers. Two controllers regulate the inlet concentration of TCE and H2O, while the third controller is used to adjust the flow rate of dry air. The three gas flows are mixed and sent to the plasma reactor, in which TCE is treated. NTP is generated in the reactor by a DC highvoltage power source. For the execution of plasma-catalytic experiments, a catalyst bed was placed downstream of the plasma reactor, in which the outlet gas of the plasma reactor is further treated. This configuration is called a post plasma-catalytic process (PPC). The last section is responsible for the analysis of the effluent by means of a FT-IR spectrometer and mass spectrometer. The ozone concentration is determined by an ozone monitor. Figure 17. Experimental set-up for the plasma-(catalytic) experiments Gas inlet preparation The inlet gas is supplied by a bottle of pressurized dry (< 3 ppm H2O) air (Alphagaz 1, Air Liquide) and is separated into three flows by means of three mass flow controllers (Bronkhorst®, El-Flow® select). The upper controller regulates the TCE concentration by passing air through a bubbling bottle containing liquid TCE (99.99% purity, Acros). The 36 bubbling bottle was located in a thermostatic water bath maintained at –8°C by adding antifreeze to the water. This low temperature is needed to decrease the volatility of TCE which facilitates the generation of TCE/air mixtures with stable initial concentrations. The TCE gas flow rate can be varied between 0 – 200 ml·min-1. The second controller is needed to adjust the total gas flow rate of the inlet and has an operating range between 0 - 10000 ml·min-1. The experiments will be performed at a constant volume flow rate of 500 and 2000 ml·min-1. The humidity of the gas inlet can be adjusted by passing the gas through a H2O containing bubbling bottle, which is regulated by the third mass flow controller (0 – 500 ml·min-1). A humidity meter (Testo® 445) is located downstream of the H2O bubbler to measure the relative humidity and the temperature of the gas inlet. The relative humidity is a good indication of the amount of H2O present in the gas inlet, since the temperature variation (20 °C ± 2) in the lab can be neglected. During the experiments, the relative humidity will be varied between 0 – 80 %. The pure air, TCE containing and water containing gas flows are then mixed and sent to the plasma reactor. Plasma reactor A multi-pin-to-plate configuration is applied as plasma reactor, and is based on the concept of a negative DC corona/glow discharge. The cylindrical casing of the reactor is made of Teflon and inserted in a glass tube which is closed by airtight fittings in order to prevent any leakages. The feed gas flows through a rectangular duct with a cross section of 40 mm x 9 mm and a length of 400 mm. The plasma source consists of ten aligned sharp hollow crown-shaped cathode pins, connected in parallel and positioned 28 mm from each other. The anode plate is profiled with spherical surface segments centered on the tip of each cathode pin. The spherical surface segment has a radius of 17.5 mm and a depth of 5 mm. The distance between the 10 cathode pins and the single anode plate is 10 mm. A picture of the multi-pin-to-plate reactor is illustrated in Figure 18. Figure 18. Picture of the multi-pin-to-plate reactor 37 Uniform and stable glow discharge operation is ensured by ballasting each cathode pin with a 1.5 MΩ resistor (Rb). The fraction of the total electrical power that is dissipated in these resistors amounts to 10 % at most. The total voltage (Utot) is distributed over the ballasting resistors and the plasma (Upl). The electric circuit of the plasma reactor is illustrated in Figure 19. The discharge is generated by applying an electric field between the cathode pins and the anode plate using a DC power supply (Technix, SR40-R-1200), at atmospheric pressure and room temperature. During experiments, the energy density of the plasma is adjusted by varying the plasma voltage. A high-voltage probe (Fluke 80 K-40, division ratio 1/1000) measures the voltage applied to the inner electrode. The discharge current is determined by recording the voltage signal across a 100 Ω resistor (R) placed in series between the counter electrode and ground. The current and plasma voltage is measured by a digital multimeter (Ohmeron MT 488B) with an accuracy of 0.8 and 0.5 %, respectively. Figure 19. Electric circuit diagram of the multi-pin-to-plate reactor with Voltmeter Utot Total voltage [kV] R Resistor (100 Ω) needed to determine I I Discharge current [mA] Ub Voltage over ballasting resistor Rb [kV] Upl Plasma voltage [kV] Rb Ballasting resistor (1.5 MΩ) of a cathode pin The plasma voltage Upl can be calculated via the voltage over resistor R and the voltage over the ballasting resistors of the cathode pins: 𝑈𝑝𝑙 = 𝑈𝑡𝑜𝑡 − 𝐼 ∙ 𝑅 − 𝐼 ∙ 𝑅𝑏 𝑁 ( 33 ) 38 with N The number of cathode pins Catalytic unit During PPC experiments, the plasma treated gas is sent through a catalytic unit. This is a cylindrical glass tube, in which the catalyst is disposed on a sintered glass plate. An illustration of the catalyst bed is shown in Figure 20. Figure 20. Catalytic unit consisting of a sintered glass plate, on which the catalyst is disposed The catalytic bed is placed in an oven, which allows to vary the catalyst temperature. The temperature of the catalyst is controlled by a temperature probe present in the glass wool of the oven (Figure 21, left), and is connected to a temperature controller (Figure 21, right). Figure 21. Illustration of the catalytic oven (left) and temperature controller (right) 39 6.4.1 Catalyst preparation For each plasma-catalytic experiment, 0.5 g of new catalyst sample is diluted with 3 g finegrained inert carborundum (SiC) to obtain a uniform gas flow over the catalyst bed. Then the catalyst is prepared by calcination with 200 ml·min-1 dry air at 350 °C (cryptomelane) and 500 °C (CeO2) for 4 hours. This step is necessary to remove impurities adsorbed on the active sites of the catalyst. After calcination, the catalyst is cooled down to room temperature before being maintained at the temperature of the experiments. A list of the catalysts studied during this thesis can be found in Table 4. Table 4. List of catalysts studied in the PPC process Catalyst name Structural formula Cerium(IV)oxide Cryptomelane Iron oxide/Cryptomelane CeO2 K-OMS-2 Fe3O4/K-OMS-2 Synthesis of the K-OMS-2 catalyst Cryptomelane (K-OMS-2) was prepared by a reflux method. KMnO4 solution was added dropwise to an aqueous solution of manganese acetate with a buffer solution (KCH3COO/CH3COOH) at pH 4.5. The suspension was stirred vigorously under reflux for 24 h with a buffer solution (KCH3COO/CH3COOH) at pH 4.5. After filtration, the precipitate was washed with deionized water and several times with distilled water until neutral pH. Then the catalyst was dried in an oven at 100 °C. Synthesis of the Fe3O4/K-OMS-2 catalyst Fe3O4 nanoparticles were grafted onto the K-OMS-2 via a coprecipitation method. The key factor in this synthesis is pH, controlling the morphology of K-OMS-2 nanowires and the formation of Fe3O4 nanoparticles. First, (NH4)2Fe(SO4)2.6H2O and Fe(NO3)3.9H2O were dissolved in water. KOH was added dropwise to decrease the acidity, which is needed to precipitate Fe(OH)3 (pH 4.0) and Fe(OH)2 (pH 9.6). Above a pH of 9.6 the cryptomelane was added. This high pH is needed so that the mixed valences (III/IV) of manganese in K-OMS-2 will not be destroyed by Fe2+ present in the solution. KOH was continuously added until the pH reached 12, and Fe3O4 nanoparticles were gradually deposited onto the K-OMS-2 nanowires. CeO2 catalyst Cerium oxide was purchased from Panreac. 40 6.4.2 Pressure drop over catalyst bed A gas flowing through a catalyst bed results in a pressure drop, which can be described by Ergun’s equation ∆𝑃 150 · µ𝑔 · 𝑣𝑔 (1 − ɛ)2 1.75 · 𝜌𝑔 · 𝑣𝑔 2 1 − ɛ = + 𝐿 ɛ3 𝐷𝑝 ɛ3 𝐷𝑝 2 ( 34 ) with ∆𝑃 Pressure drop over catalyst bed [Pa] 𝐿 Length of the catalyst bed [m] µ𝑔 Gas viscosity [Pa·s] 𝑣𝑔 Gas velocity [m·s-1] 𝐷𝑝 Particle diameter [m] ɛ Bed porosity [-] 𝜌𝑔 Gas density [kg/m3] The pressure drop resulted in a decreased TCE concentration in the gas passing through the catalyst bed, in comparison with the gas flow through the by-pass. To avoid this effect, the same pressure drop over the catalyst bed is manually set over the by-pass, by manipulating valves 1 and 2 in the by-pass (Figure 17). In this way, the same TCE inlet concentration in the by-pass as over the catalyst bed is obtained, and can be measured. A pressure indicator (Druck DPI 705) with a range between 0 – 700 bar is used to monitor the pressure drop over the bed. The plasmacatalytic experiments were performed at low gas flow rate (500 ml·min-1) in order to limit the pressure drop over the catalyst bed. Temperature has an effect on the gas density and velocity, but only slightly influenced the pressure drop. Gas outlet analysis TCE removal efficiency and the identification of the by-products were determined with a FTIR spectrometer. However, some of the by-products formed during TCE abatement are hardly to distinguish from each other due to overlapping absorption bands of these compounds in the IR spectrum. Moreover, compounds such as Cl2 only contain a symmetric bond that does not change in dipole moment during vibration. These compounds are IR inactive and cannot be determined via IR spectroscopy. For this reason, a mass spectrometer is used to determine these products. Moreover, the combination of an IR-spectrum and MS-spectrum provides a more reliable identification of the products formed during TCE abatement experiments. An ozone monitor is used to measure the ozone concentration in the gas outlet. 41 6.5.1 FT-IR analysis The FT-IR spectrometer (Bruker, Vertex 70) used during the experiments is illustrated in Figure 22. The description of the working principle of the spectrometer can be found in 5.1. Figure 22. Illustration of the FT-IR spectrometer (Bruker, Vertex 70) The optical length of the gas cell and the resolution of the spectrometer were set at 20 cm and 4 cm-1, respectively. The mercury-cadmium-telluride (MCT) detector is nitrogen cooled and OPUS (Bruker) software is used to collect and analyze the obtained spectra. Spectra were taken after steady state condition and consisted of ten averaged measurements. Each spectrum is recorded from 3045 to 600 cm-1, which is the region where TCE abatement products are absorbed. Quantitative analysis of TCE, CO and CO2 In order to study the TCE abatement in the plasma reactor, TCE must be quantified in the gas flow. This can be done by constructing a calibration curve by choosing a characteristic IR band of TCE with a high intensity, which does not interfere with absorption bands of by-products. The absorbance is proportional to the TCE concentration via the Beer-Lambert law: 𝐴 = log 𝐼0 = 𝑎 · 𝐶𝑇𝐶𝐸 · 𝑑 𝐼 ( 35 ) with A Absorbance [-] I0 Intensity of the incident light [cd] I Transmitted light intensity [cd] 42 Molar absorption coefficient [L·mol-1·cm-1] 𝑎 TCE concentration [mol·L-1] CTCE d Optical path length [cm] The above formula can also be applied for the integrated area under a characteristic IR band, since this is an averaging of the absorbance between two wavenumbers. The calibration curve can be obtained from the integrated peak area by measuring a standard sample of known TCE concentration. A TCE (500 ppm, 2 % uncertainty) containing calibration mixture is used for the construction of the calibration curve, shown in Figure 23. The absorption band at 945 cm-1 is chosen as calibration peak, and is integrated between 916 – 966 cm-1. The calibration curve results in a formula to calculate TCE concentrations based on the integrated surface area: 𝐶𝑇𝐶𝐸 = 500 ·𝑆 1.3888 𝑖𝑛𝑡,𝑇𝐶𝐸 ( 36 ) with CTCE TCE concentration [ppm] Sint,TCE Integrated surface area of the absorption band between 916 – 966 cm-1 [-] 600 TCE concentration (ppm) 500 400 300 200 100 0 0 0.2 0.4 0.6 0.8 1 1.2 Integrated surface area (-) 1.4 1.6 Figure 23. Calibration curve for the quantitative analysis of TCE In addition to TCE, it is also interesting to quantify the amount of oxidation products CO and CO2 present in the treated outlet gas. In this way, the selectivity of the TCE abatement reactions towards COx can be determined and compared with the selectivity towards unwanted chlorinated by-products. A calibration mixture containing CO and CO2 is used to construct the corresponding calibration curves (Figure 24). The characteristic absorption bands for CO and CO2 are integrated between 2144 – 2223 cm-1 and 2283 – 2393 cm-1, respectively. Based on the calibration curves, the CO and CO2 concentration can be calculated as follows: 𝐶𝐶𝑂 = 250 ·𝑆 0.2543 𝑖𝑛𝑡,𝐶𝑂 ( 37 ) 43 𝐶𝐶𝑂2 = 250 ·𝑆 4.6948 𝑖𝑛𝑡,𝐶𝑂2 ( 38 ) with CCO,CO2 Sint,CO Sint,CO2 COx concentration [ppm] Integrated surface area of the CO absorption band between 2144 – 2223 cm-1 [-] Integrated surface area of the CO2 absorption band between 2283 – 2393 cm-1 [-] 300 250 CO2 concentration (ppm) CO concentration (ppm) 300 200 150 100 50 250 200 150 100 50 0 0 0 0.05 0.1 0.15 0.2 0.25 Integrated surface area (-) 0.3 0 1 2 3 4 Integrated surface area (-) 5 Figure 24. Calibration curve for the quantitative analysis of CO (left) and CO2 (right) 6.5.2 MS analysis The mass spectrometer (MS) used during the experiments is a Quadrupole Triple Filter MS (Hiden Analytical, HPR 20 QIC) equipped with a Faraday and SEM detector. A picture of the mass spectrometer is shown in Figure 25. Figure 25. Illustration of the Quadrupole Mass Spectrometer (Hiden Analytical, HPR 20 QIC) 44 MASsoft 7 software (Hiden Analytical) is applied for collecting and displaying data. Only the maximum peak intensities and the corresponding m/z numbers are collected. The peaks are represented as bar lines over the corresponding m/z. The Faraday (10-5 Torr) and SEM (10-7 Torr) detector are scanning in the mass range 1 – 44 and 45 – 150 m/ z, respectively. A resolution of 50 with electron ionization energy of 70 V was adopted. 6.5.3 Ozone monitor The ozone concentration in the gas outlet is measured with an ozone monitor (Teledyne API Model 450 O3 Monitor), illustrated in Figure 26. The detection of ozone molecules is based on absorption of 254 nm UV light due to an internal electronic resonance of the O3 molecule. The monitor uses a mercury lamp and emits light through a hollow quartz tube that is alternately filled with sample gas, then filled with gas scrubbed to remove ozone. The ratio of the intensity of light passing through the scrubbed gas to that of the sample is determined and forms the basis for the calculation of the ozone concentration via the Beer-Lambert law (equation (35)). The specifications of the ozone monitor are listed in Table 5. Table 5. Features of the ozone monitor (Teledyne API Model 450) Measurement range Lower detectable limit Sample flow rate Accuracy Resolution 0 – 1000 ppm 0.003 ppm 1 – 2.5 L·min-1 ± 0.1 % 0.001 ppm Figure 26. Illustration of the ozone monitor (Teledyne API Model 450) 45 7 Plasma characterization Before abatement experiments are performed, the multi-pin-to-plate discharge reactor is characterized by its voltage-current characteristics and the ozone production during plasma treatment. Voltage-current curves Voltage-current characteristics are obtained by plotting the relation between the plasma voltage (Upl) and the current through the plasma (I). The product of these parameters expresses the electrical power supplied to the gas. Mostly, the electrical power is divided by the volumetric gas flow rate, which is called the energy density. This parameter expresses the amount of energy supplied per unit of gas volume. The voltage-current relation gives insight into the energy density at which transition from corona to glow discharge occurs and the maximal achievable energy density. The latter is limited by the occurrence of sparks at high voltage, and has to be avoided. In practice, reduced current-voltage curves are applied to better visualize the different discharge regimes. In these curves, the reduced current (Ired) is defined as the current divided by the plasma voltage. The reduced current-voltage curves are obtained by manually increasing the plasma voltage from 0 Volt to the voltage at which sparking occurs. The corona regime occurs at low voltage (around 7 kV in dry air) and is visualized by weak purple light emitted at the sharp points of the crown-shaped cathode pins. Plasma is only generated at the cathode pins due to significant concentration of the electric field exclusively around these sharpened electrodes. The whole inter-electrode gap is dark. In the corona regime, the reduced current increases proportional with the plasma voltage. A further increase of the plasma voltage leads to a transition of the corona to glow discharge. In contrast to the corona, the electric field in the glow discharge is high along the whole inter-electrode gap, and purple light is now emitted in the whole gap. As a certain voltage is reached, the glow discharge turns into sparking. When sparking starts, the experiment is stopped and the voltage is turned off to avoid damaging of the electrodes. Ozone production Another important plasma parameter is the ozone production. The amount of ozone produced in NTP is a measure for the plasma reactivity since its occurrence can be correlated with reactive species concentrations in the NTP. In addition, ozone monitoring is crucial due to its negative effect on human health. The ozone outlet concentration is measured with an ozone monitor, and can be used to calculate the ozone production (g/h) by the following formula: 𝑂𝑧𝑜𝑛𝑒 𝑝𝑟𝑜𝑑𝑢𝑐𝑡𝑖𝑜𝑛 = 𝑂𝑧𝑜𝑛𝑒 𝑐𝑜𝑛𝑐𝑒𝑛𝑡𝑟𝑎𝑡𝑖𝑜𝑛 𝑃 · 𝑀𝑂𝑧𝑜𝑛𝑒 · ·𝑄 6 10 𝑅 · 𝑇𝑔𝑎𝑠 𝑔𝑎𝑠 ( 39 ) 46 with ozone concentration in [ppm], Mozone the molecular weight in [g·mol-1], P the pressure in [Pa], Tgas the gas temperature in [K], R the gas constant (R = 8.314 J·K-1·mol-1) and Qgas the gas flow rate in [m3·s-1]. In what follows, current-voltage curves and ozone production will be discussed based on plasma experiments under different conditions. The experiments are performed with air and the following parameters will be investigated: gas flow rate, humidity and TCE concentration. Influence of gas flow rate The experiments show that the gas flow rate has an effect on the voltage-current curves, as can be seen in Figure 27. For a constant applied voltage, higher currents are measured with increasing gas flow rate. For a voltage of 11 kV, a current of 0.42 and 0.67 mA is measured for a gas flow rate of 0.5 and 2 L·min-1, respectively. At higher voltages the difference in current becomes more pronounced. In addition, the maximum achievable current is higher for a gas flow rate of 2 L·min-1. This phenomenon is also observed by other researchers [39, 105] who investigated the influence of gas flow rate on corona-to-glow and glow-to-spark threshold currents in a multi-pin-to-plate DC corona discharge. The increase of the threshold current for sparking with increasing gas flow rate can be explained as follows. Sparks are formed by the occurrence of local ionization instabilities present in the plasma at high voltages. A gas flow is able to blow away these instabilities and increases the current at which sparks are formed. Higher gas flow rates, resulting in higher turbulence, are able to better disperse these instabilities compared to lower gas flow rates. Next to ionization instabilities, the threshold current for spark formation is also determined by the occurrence of discharge thermal instabilities. These instabilities mainly come from the discharge thermal load. The temperature at the outlet of the plasma reactor is slightly higher than at the inlet due to heating of the gas by the plasma. A higher temperature in the discharge volume will increase the reduced field E/N, in which E is electric field and N is the density of the gas. The increase of the reduced field will in turn increase the ionization rate and more heat will be produced. The higher ionization rate at the outlet of the reactor results in a higher electron density, and thus in a higher current. These conditions of increased current lead to the formation of anode spots which in turn cause spark formation. During the experiments, the formation of a spark discharge near the exit of the plasma reactor was observed in most of the cases. Again, by applying a fast gas flow the heat produced by the discharge can be blown away and the thermal instability can be effectively avoided. Another parameter that affects the voltage-current curves is the electrode geometry. Akishev et al. [39] investigated the effect of electrode geometry on the threshold currents for the coronato-glow and glow-to-spark transitions. The highest threshold currents were obtained by applying hollow crown-shaped cathode pins and an anode plate with a spherical crater, with an 47 inter-electrode distance of 9 mm. Therefore, this optimal electrode geometry is also applied in this thesis. Reduced current-voltage curves are plotted at the right hand side of Figure 27 to visualize the corona-to-glow transition. For a gas flow rate of 2 L·min-1 the glow regime occurs around 10.5 kV. In case of the lower gas flow rate no clear demarcation between the corona and glow regime is visible. 2.0 L/min 0.5 L/min 0.07 12 0.06 Reduced current (mA/kV) Plasma voltage (kV) 0.5 L/min 13 11 10 9 8 7 2.0 L/min 0.05 0.04 0.03 0.02 0.01 6 0.00 0.0 0.1 0.2 0.3 0.4 0.5 Current (mA) 0.6 0.7 7 8 9 10 11 Plasma voltage (kV) 12 Figure 27. Voltage-current (left) and reduced current-voltage (right) characteristics for two different gas flow rates. (dry air, CTCE = 0 ppm, T = 294 K, atmospheric pressure) In addition to the current, the ozone production is monitored as function of the plasma voltage for both gas flow rates. As can be seen in Figure 28, a higher gas flow rate results in a higher ozone production for a given energy density. The energy density is defined as the applied electric power (Pel) divided by the gas flow rate (Q), and expresses the amount of energy supplied to the gas per unit of gas volume. An increasing ozone production at higher gas flow rates can be explained due to the occurrence of a dilution effect when applying higher gas flow rates. Indeed, the ratio of the ozone production between a gas flow rate of 0.5 and 2 L·min-1 is around four at a given energy density. The ozone production also increases with increasing energy density. This is due to the increased production of reactive electrons in the plasma when applying a higher energy density. When looking at the ozone outlet concentration as function of the energy density (Figure 28, right), it becomes clear that the ozone concentration is independent of the gas flow rate. Vandenbroucke [106] reported a linear correlation between the ozone production and the energy density. The curves in Figure 28 deviate from linear behavior, which is possibly caused by measurement errors of the ozone monitor, due to a poor calibration. 48 0.5 L/min 2.0 L/min 0.5 L/min 0.20 2.0 L/min 800 700 O3 concentration (ppm) O3 production (g/h) 0.16 0.12 0.08 0.04 600 500 400 300 200 100 0.00 0 0 50 100 150 200 Energy density (J/L) 250 0 50 100 150 Energy density (J/L) 200 250 Figure 28. Ozone production (left) and the ozone outlet concentration (right) as function of the energy density for two different gas flow rates. (dry air, CTCE = 0 ppm, T = 294 K, atmospheric pressure) Influence of humidity The influence of humidity on the plasma characteristics is investigated by adding a certain amount of water vapor to dry air. The relative humidity (RH) is monitored with a humidity meter and seven different values of humidity were investigated. Figure 29 illustrates the effect of humidity on the reduced current-voltage curves. With increasing humidity a higher plasma voltage is needed to achieve the same reduced current. For a reduced current of 0.02 mA·kV-1 the plasma voltage increases from 8.7 to 12.1 kV when the humidity increases from 5 to 50 % RH. The increase in plasma voltage is more pronounced for relative humidity between 2.8 and 20 % compared to higher humidity. It is also observed that an increase in humidity led to an unstable plasma, which resulted in a decrease of the threshold current for spark formation. The increase of the plasma voltage can be explained by the electron capturing behavior of water molecules [107]. It is well recognized that water can trap energetic electrons via electron impact dissociative attachment: ( 40 ) 𝐻2 𝑂 + e− → 𝑂𝐻 + H − An increase of the relative humidity leads to a higher number of H2O attachment reactions, and thus a decrease in current. To maintain the same current this electron loss has to be compensated by electron producing processes, such as ionizing collisions. To increase the rate of these collisions, the electric field has to be increased. 49 2.8% RH 5% RH 10% RH 20% RH 50% RH 80% RH 15% RH 0.07 Reduced current (mA/kV) 0.06 0.05 0.04 0.03 0.02 0.01 0.00 7 8 9 10 11 Plasma voltage (kV) 12 13 Figure 29. Reduced current-voltage characteristics for different levels of air humidity. (humid air, CTCE = 0 ppm, Q = 2 L·min-1, T = 294.4 K, atmospheric pressure) Humidity also affects the ozone outlet concentration, as can be seen in Figure 30. Measurements showed a nonlinearly decreasing ozone production at increased humidity levels, with a larger rate of reduction at lower humidity. The ozone outlet concentration for an energy density of 100 J·L-1 is 414 ppm for dry air, while this decreased to 281 ppm at 50 % RH and 228 ppm at 80 % RH. 2.8% RH 5% RH 10% RH 20% RH 50% RH 80% RH 15% RH 800 O3 concentration (ppm) 700 600 500 400 300 200 100 0 0 50 100 150 Energy density (J/L) 200 250 Figure 30. Ozone outlet concentration as function of the energy density for different air humidity levels. (humid air, CTCE = 0 ppm, Q = 2 L·min-1, T = 294.4 K, atmospheric pressure) The decrease in ozone production with increasing humidity was also observed by Morent and Leys [69], who intensively studied ozone generation in air by a multi-pin-to-plate DC corona 50 discharge. Chen and Wang [108] modified existing models for ozone production by DC coronas in dry air and incorporated the effect of water. They unveiled the critical pathway for ozone production and indicated the following reactions as most important ozone production reactions: 𝑂 + 𝑂2 + 𝑂2 → 𝑂3 + 𝑂2 ( 41 ) 𝑂 + 𝑂2 + 𝑁2 → 𝑂3 + 𝑁2 ( 42 ) 𝑂2 ∗ + 𝑂2 → 𝑂3 + O ( 43 ) At higher humidity levels, the contribution of reactions (41) and (42) to the ozone formation is strongly decreased due to the reduction of oxygen radicals in humid air by 𝐻2 𝑂 + 𝑂 → 𝑂𝐻 + 𝑂𝐻 ( 44 ) The rate of reaction (43) is proportional to the concentration of 𝑂2 ∗ and relates to the electron distribution. Since the electron distribution is independent of relative humidity, the concentration of 𝑂2 ∗ , and thus the rate of reaction (43) is the same for both dry and humid air. Besides the ozone producing reactions, the change in rate of the ozone destruction reactions also contributes to the decreasing ozone outlet concentration with increasing humidity. The most important ozone destruction reactions are listed below. 𝑁𝑂 + 𝑂3 → 𝑁𝑂2 + 𝑂2 ( 45 ) 𝑂𝐻 + 𝑂3 → 𝐻𝑂2 + 𝑂2 ( 46 ) In dry air, 𝑂3 is primarily destructed by NO through reaction (45). At higher relative humidity the contribution of reaction (46) strongly increases and becomes the primary ozone destruction reaction. However, the relative production of OH radicals reaches a peak value between 40 and 60 % RH. This phenomenon was observed by Ge et al. [109] and can be explained as follows. Next to reaction (46), the amount of OH radicals varies with the collision frequency between energetic electrons and water molecules. At low humidity, the collision frequency between energetic electrons and water molecules will stay low but increases with increasing humidity. On the other hand, with increasing humidity, more electrons will be absorbed by water due to its electronegativity. This results in a reduction of the mean density of energetic electrons, which in turn leads to a reduction of the collision frequency between energetic electrons and water molecules. This explains the smaller rate of reduction in ozone outlet concentration at higher humidity levels (Figure 30). 51 Influence of TCE Since TCE will be used during the abatement experiments, it is interesting to investigate the influence of the presence of TCE on the plasma characteristics. First, the influence of the TCE concentration on the reduced current-voltage characteristic will be discussed. Addition of TCE leads to a decrease of the reduced current, as illustrated in Figure 31. A TCE concentration of 250 ppm and a plasma voltage of 11 kV resulted in a reduced current of 0.03 mA·kV-1, compared to 0.05 mA·kV-1 for dry air. A further increase of the TCE concentration has only minor effects on the reduced current. The current at which the corona-to-glow transition occurs is hard to determine based on Figure 31, but is around 0.68 mA for all four curves. The measurements were performed until sparking occurred, which means that the glow-to-spark transition is marked by the last data point on the curve. 0 ppm TCE 250 ppm TCE 500 ppm TCE 0.08 Reduced current (mA/kV) 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0.00 7 8 9 10 11 12 Plasma voltage (kV) 13 14 15 16 Figure 31. Reduced current-voltage characteristics for different TCE concentrations. (dry air, Q = 2 L·min-1, T = 294 K, atmospheric pressure) As in case of the presence of water, a reduction of the threshold current for spark formation is expected with increasing TCE concentration, due to the destabilizing influence of this electronegative compound. However, addition of TCE led to a slight increase of the threshold current from 0.82 mA (dry air) to 0.9 mA (500 ppm TCE). A possible explanation for this is that the addition of TCE improves the uniformity of the current distribution in the direction of the gas flow. This effect was observed by Vertriest et al. [37] who investigated the distribution of the current, drawn by the individual cathodes in a multi-pin-to-plate plasma reactor, consisting of 5 rows of 20 cathode pins. Addition of 160 ppm TCE to dry air led to a less steep current profile (Figure 32), which can be explained by the increase of the reduced field (E/N) dependent electron attachment rates to TCE and its by-products. 52 Figure 32. Effect of TCE on the distribution of the current drawn by individual cathode pins in a multi-pin-to-plate plasma reactor. [37] The presence of TCE also affects the ozone produced in the plasma reactor, as can be seen in Figure 33. For an energy density of 200 J·L-1, addition of 250 ppm TCE to dry air led to a reduction of the ozone concentration from 670 to 409 ppm. Further increase of the TCE concentration to 500 ppm further decreased the ozone concentration to 305 ppm. A plausible explanation for this effect lays in the competition between TCE and O2 to react with oxygen radicals. A higher TCE concentration results in a higher consumption of oxygen radicals towards numerous end by-products, which inhibits the reaction between O2 and O towards O3. The most common TCE abatement reactions in the presence of oxygen radicals, suggested by Vandenbroucke et al. [63], are listed below. 𝐶2 𝐻𝐶𝑙3 + 𝑂 → 𝐶𝐻𝑂𝐶𝑙 + 𝐶𝐶𝑙2 ( 47 ) 𝐶2 𝐻𝐶𝑙3 + 𝑂 → 𝐶𝑂𝐶𝑙 + 𝐶𝐻𝐶𝑙2 ( 48 ) 𝐶2 𝐻𝐶𝑙3 + 𝑂 → 𝐶2 𝐶𝑙3 + 𝑂𝐻 ( 49 ) 53 0 ppm TCE 250 ppm TCE 500 ppm TCE 900 800 O3 concentration (ppm) 700 600 500 400 300 200 100 0 0 100 200 Energy density (J/L) 300 400 Figure 33. Ozone outlet concentration as function of the energy density, for different TCE concentrations. (dry air, Q = 2 L·min-1, T = 294 K, atmospheric pressure) 54 8 Plasma-assisted TCE abatement In this part the removal of TCE in the multi-pin-to-plate plasma reactor will be investigated. Focus is on the removal efficiency and the selectivity of the abatement process towards oxidation products. In an ideal process under humid conditions, TCE is completely oxidized by reaction with oxygen and hydroxyl radicals via [110] 𝐶2 𝐻𝐶𝑙3 + 4𝑂𝐻 → 𝐶𝑂2 + 3𝐻𝐶𝑙 + 𝐻2 ( 50 ) 𝐶2 𝐻𝐶𝑙3 + 4𝑂 → 2𝐶𝑂2 + 𝐻𝐶𝑙 + 𝐶𝑙2 ( 51 ) The end products CO2 and H2 can be exhausted to the atmosphere. HCl can be easily removed from the outlet gas by a water scrubber. This results in an acidic solution which can be neutralized with a base. Scrubbing with water alone is impractical for the removal of Cl2 due to its limited solubility in water. Cl2 can be scrubbed with an aqueous NaOH solution resulting in products NaCl and NaOCl (hypochlorite). The latter can be used as bleaching agent. The stoichiometry of reactions (50) and (51) is, however, difficult to achieve in NTP. As explained before, incomplete oxidation leads to the formation of harmful chlorinated by-products. The goal of the plasma-assisted experiments is to investigate the influence of several parameters on the performance of the TCE abatement process, in order to maximize the conversion of TCE towards oxidation products CO2, H2O, HCl and Cl2. Two parameters will be investigated during the experiments: gas flow rate and humidity. By-products formed during TCE abatement will be identified based on the FT-IR and MS spectra of the outlet gas. Identification of TCE abatement products Before investigating the influence of gas flow rate and humidity on the performance of the TCE removal process, it is interesting to identify the range of by-products formed during this process. To do this, a preliminary experiment is performed on basis of which the products present in the outlet gas are determined by FT-IR in combination with MS. Table 6. Characteristic IR bands of TCE [111] Wavenumber range (cm-1) Vibration - 3115 – 3065 A B C D E F 1615 – 1530 1305 – 1215 970 – 885 865 – 815 785 655 – 605 C–H olefinic C–H stretch vibration C=C stretch vibration C–H deformation C–H out of plane deformation No unambiguous explanation C–Cl vibration C–Cl vibration 55 TCE inlet TCE outlet 0.09 D 0.08 0.07 C 0.05 0.04 E Absorbance (-) 0.06 0.03 0.02 A F B 0.01 0 3000 2800 2600 2400 2200 2000 1800 1600 1400 Wavenumber (cm-1) 1200 1000 800 600 Figure 34. FT-IR spectra between 600 and 3050 cm-1 of TCE inlet (black) and plasma treated TCE gas (red) at an energy density of 50 J·L-1 (dry air, CTCE = 500 ppm, Q = 2.0 L∙min-1, T = 293 K, atmospheric pressure) Figure 34 shows the FT-IR spectra of both the TCE inlet (black line) and outlet gas (red line) when the plasma reactor is operated at 50 J·L-1. The characteristic IR bands of TCE are indicated with letters, and listed in Table 6. Out of these characteristic IR bands, the peak at 945 cm-1 is chosen to calculate the TCE removal efficiency since this band is not disturbed by interference of bands originating from by-products. The reduction in surface area of this peak and the occurrence of new peaks in the outlet spectrum indicates the decomposition of TCE into a range of by-products. By comparing the outlet spectrum with reference compound spectra of NIST, the most important by-products will be identified. Figure 36, Figure 37 and Figure 38 show zoomed outlet spectra to study the plasma treated TCE gas in more detail. Numbers are used to allocate different IR bands to the corresponding product. In addition to FT-IR, mass spectra of the inlet and outlet gas are recorded in order to identify additional by-products. The presence of some products cannot be proved with FT-IR due to interference with bands of other products. Also, diatomic molecules such as Cl2 are IRtransparent and cannot be identified with FT-IR. The mass spectrum of the TCE inlet gas is shown in Figure 35, and only contains the characteristic TCE fragment ions. The typical fragment ions formed during collisions between electrons and TCE are C2HCl+ (m/z: 60, 62), C2HCl2+ (m/z: 95, 97, 99) and C2HCl3+ (m/z: 130, 132, 134, 136). The mass spectrum of the outlet gas, treated at an energy density of 200 J·L-1, shows a decrease in the abundance of the TCE fragment ions, indicating partial TCE degradation. The products corresponding with these peaks are identified by comparison to the NIST mass spectral library. A description of the different products identified with FT-IR and MS is given below. 56 Figure 35. Mass spectrum of the TCE inlet gas (a) and the plasma treated outlet gas (b) at an energy density of 200 J·L1 (dry air, C -1 TCE = 500 ppm, Q = 0.5 L∙min , T = 293 K, atmospheric pressure) Dichloroacetylchloride (DCAC) The formation of DCAC can be confirmed by comparing the outlet FT-IR spectrum with the reference spectrum of DCAC (Appendix, Figure 77). The characteristic IR bands of this compound appear at 1820, 1789, 1225, 1076, 989, 800 and 740 cm-1. In the mass spectrum of the outlet gas, the characteristic fragment ions of m/z 83, 85 (CHCl2+), m/z 63, 65 (CClO+), m/z 48, 50 (CHCl+) can be ascribed to DCAC. DCAC belongs to the group of acid chlorides and is also a VOC. Studies have shown negative effects of DCAC on human health [112]. 57 The presence of DCAC in the outlet of plasma treated TCE gas is also confirmed by other researchers [113-115]. Kirkpatrick et al. [116] detected DCAC as the primary by-product of TCE decomposition and suggested the following reaction pathways. 𝐶2 𝐻𝐶𝑙3 + 𝐶𝑙𝑂 → 𝐶𝐻𝐶𝑙2 𝐶𝑂𝐶𝑙 + 𝐶𝑙 ( 52 ) 𝐶2 𝐻𝐶𝑙3 + 𝑂𝐻 → 𝐶𝐻𝐶𝑙2 𝐶𝑂𝐶𝑙 + 𝐻 ( 53 ) DCAC can further decompose by attack of Cl radicals, leading to the formation of CO, HCl, CCl4, CHCl3 and COCl2 as final products. However, the formation of CCl4 and CHCl3 could not be unambiguously proven based on the outlet spectra. Trichloroacetaldehyde (TCAA) Many researchers [9, 71, 110, 113] who studied the abatement of TCE in NTP reported the presence of TCAA in the outlet gas. Due to the absence of a reference IR spectrum in the NIST databank, TCAA could not be identified with FT-IR. However, analysis of the mass spectrum can reveal the formation of this chlorinated VOC as by-product. Indeed, the characteristic fragment ions of m/z 82, 84 (CCl2+) can be ascribed to TCAA. Fragment ions of m/z 48, 50 (CHCl+) are also formed by collision between electrons and TCAA, but can also originate from DCAC. TCAA is toxic when inhaled or absorbed through skin and causes respiratory tract irritation [117]. Therefore, the formation of this compound has to be minimized. Phosgene (COCl2) Phosgene is a highly toxic acid chloride that can cause suffocation by inhalation [118]. The presence of this compound can be indicated by the characteristic bands at 1827, 1685 and 850 cm-1 (Appendix, Figure 78). At 850 cm-1, the band of phosgene is interfered with a TCE characteristic band. The presence of phosgene can be indicated since this band of TCE does not decrease to the same extent as the non-interfered TCE band at 945 cm-1. Phosgene is also detected by the characteristic fragment ions 63 and 65 m/z (CO35Cl+ and CO37Cl+) present in the mass spectrum of the outlet gas. The formation of phosgene is also confirmed by Vandenbroucke et al. [63], who modelled the abatement of TCE in a negative multi-pin-to-plate corona discharge. For an energy density of 300 J·L-1, the model predicted that phosgene accounts for about 30 % of the formed by-products in dry air. Phosgene is mainly produced by reaction between TCE and ClO radicals, as shown below. 𝐶2 𝐻𝐶𝑙3 + 𝐶𝑙𝑂 → 𝐶𝑂𝐶𝑙2 + 𝐶𝐻𝐶𝑙2 ( 54 ) Phosgene can further decompose by Cl abstraction of chlorine, oxygen or other radicals forming CO, Cl2 and Cl radicals [25]. A possible way to remove phosgene from the outlet gas is by 58 passing it through a water scrubber leading to the formation of HCl and CO2. HCl can be neutralized by addition of a base [110]. Molecular chlorine (Cl2) The production of Cl2 in NTP has to be stimulated since the presence of this compound indicates total oxidation of TCE (reactions (50) and (51)). However, a large amount of the Cl radicals formed in NTP does not recombine towards Cl2, but further react with other compounds or radicals. An important intermediate is ClO, formed by collision between Cl and O radicals. This radical further reacts with TCE to form toxic phosgene and methyldichloride, which in turn rapidly reacts with oxygen via 𝐶2 𝐻𝐶𝑙3 + 𝐶𝑙𝑂 → 𝐶𝑂𝐶𝑙2 + 𝐶𝐻𝐶𝑙2 ( 55 ) 𝐶𝐻𝐶𝑙2 + 𝑂 → 𝐶𝐻𝑂𝐶𝑙 + 𝐶𝑙 ( 56 ) Cl2 is IR-transparent and cannot be identified in a FT-IR spectrum, but the mass spectrum of the outlet gas revealed the formation of Cl2 by the peaks at m/z 70 (35Cl35Cl+), 72 (35Cl37Cl+) and 74 (37Cl37Cl+). Hydrogen chloride (HCl) The presence of HCl is clearly visible in Figure 38 by looking at the characteristic bands of HCl (Appendix, Figure 79) between 3050 and 2700 cm-1. Chlorine radicals, mainly produced by dissociation of COCl, are very important for controlling the TCE destruction chemistry, and largely contribute to the production of Cl-containing by-products. A part of the formed chlorine radicals reacts via different reaction pathways towards HCl. 𝐶𝐻𝑂𝐶𝑙 + 𝐶𝑙 → 𝐶𝑂𝐶𝑙 + 𝐻𝐶𝑙 ( 57 ) 𝐶𝐻𝐶𝑙2 𝐶𝑂𝐶𝑙 + 𝐶𝑙 → 𝐶𝐶𝑙2 𝐶𝑂𝐶𝑙 + 𝐻𝐶𝑙 ( 58 ) 𝐶2 𝐻𝐶𝑙3 + 𝐶𝑙 → 𝐶2 𝐶𝑙3 + 𝐻𝐶𝑙 ( 59 ) 𝐻𝑂𝐶𝑙 + 𝐶𝑙 → 𝐶𝑙𝑂 + 𝐻𝐶𝑙 ( 60 ) Carbon monoxide (CO) CO can be easily recognized in a FT-IR spectrum by the occurrence of two typical peaks at 2120 and 2180 cm-1, as shown in the reference spectrum of CO (Appendix, Figure 80). Indeed, these peaks are also present in the zoomed FT-IR spectrum (Figure 38) of the plasma treated outlet gas. Inhalation of CO can cause harmful health effects by reducing oxygen delivery to the bodies organs and tissues. Despite these negative effects, CO is less harmful than several chlorinated by-products (e.g. DCAC, TCAA and phosgene), explaining the aim for a high COx selectivity. The CO concentration in the outlet depends on the amount of COCl formed during plasma treatment, as this is the main source for CO production. In both dry and humid air, most of the COCl is converted into CO by oxidation with O2 and ClO. Another reaction pathway is the decomposition of COCl into Cl and CO. 59 𝐶𝑂𝐶𝑙 + 𝑂2 → 𝐶𝑙𝑂2 + 𝐶𝑂 ( 61 ) 𝐶𝑂𝐶𝑙 + 𝐶𝑙𝑂 → 𝐶𝑙2 + 𝐶𝑂 + 𝑂 ( 62 ) 𝐶𝑂𝐶𝑙 → 𝐶𝑙 + 𝐶𝑂 ( 63 ) Carbon dioxide (CO2) CO2 is the most favorable by-product formed during TCE abatement, and can be identified by the presence of a peak around 2350 cm-1 (Appendix, Figure 81). This peak is present in the zoomed spectrum of the outlet gas (Figure 38), but is split into two smaller bands. CO2 can be produced by oxidation of active species (e.g. CO, COCl, OH) formed in NTP. 𝐶𝑂𝐶𝑙 + 𝑂2 → 𝐶𝑙𝑂 + 𝐶𝑂2 ( 64 ) 𝐶𝑂 + 𝑂𝐻 → H + CO2 ( 65 ) 𝐶𝑂 + 𝑂 → CO2 ( 66 ) 𝐶𝑂 + 𝐶𝑙𝑂 → 𝐶𝑙 + 𝐶𝑂2 ( 67 ) Ozone (O3) The presence of ozone in the outlet gas can be confirmed based on the two characteristic bands around 1022 cm-1 (Appendix, Figure 82) in the FT-IR spectrum. The most dominant production and destruction pathways for ozone are already discussed in 3.6. The ozone concentration in the treated gas has to be minimized due to their negative effects on human health. A lot of research is done on the use of a plasma in combination with a catalyst, which is able to efficiently decompose ozone, leading to the production of active oxygen species. These species further oxidize the by-products, which results in an increased COx selectivity. Plasma-catalytic TCE abatement will be studied later. 60 TCE & phosgene 0.07 0.06 DCAC TCE DCAC 0.05 0.04 DCAC DCAC O3 TCE Absorbance (-) TCE DCAC 0.03 TCE 0.02 0.01 0 1300 1200 1100 1000 900 Wavenumber (cm-1) 800 700 600 Figure 36. Detailed FT-IR spectrum between 1350 and 600 cm-1 of the plasma treated TCE gas at an energy density of 50 J·L-1 (dry air, CTCE = 500 ppm, Q = 2.0 L∙min-1, T = 293 K, atmospheric pressure) DCAC 0.05 phosgene 0.045 0.04 0.03 TCE 0.025 phosgene 0.02 Absorbance (-) 0.035 0.015 0.01 0.005 2050 1950 1850 1750 1650 Wavenumber (cm-1) 1550 1450 0 1350 Figure 37. Detailed FT-IR spectrum between 2050 and 1350 cm-1 of the plasma treated TCE gas at an energy density of 50 J·L-1 (dry air, CTCE = 500 ppm, Q = 2.0 L∙min-1, T = 293 K, atmospheric pressure) 61 0.004 CO2 CO 0.0035 0.0025 HCl 0.002 0.0015 Absorbance (-) 0.003 0.001 0.0005 3050 2950 2850 2750 2650 2550 2450 Wavenumber (cm-1) 2350 2250 2150 0 2050 Figure 38. Detailed FT-IR spectrum between 3050 and 2050 cm-1 of the plasma treated TCE gas at an energy density of 50 J·L-1 (dry air, CTCE = 500 ppm, Q = 2.0 L∙min-1, T = 293 K, atmospheric pressure) Now that the different degradation products of TCE are identified, the plasma-assisted experiments can be performed. For each set of experiments, the removal efficiency and the formation of products CO, CO2, ozone, HCl, phosgene and DCAC are investigated. Influence of gas flow rate The plasma-assisted experiments were performed at different values of energy density of the plasma. In addition, two values for the gas flow rate were investigated: 0.5 and 2 L∙min-1, which correspond to a residence time of 17.2 and 4.2 seconds, respectively. All TCE abatement experiments were performed with a TCE concentration of 500 ppm. The influence of the energy density on the removal efficiency is presented in Figure 39, for both flow rates. The error bars indicate the 95 % confidence interval, based on the standard deviation of two measurements. An increase in removal efficiency is observed upon higher energy density, which is due to the higher density of the radicals responsible for destruction of TCE, such as O, ClO and CHCl2. These radicals are produced by electron impact reactions with the background gas in plasma, and the rates of these reactions increase at higher energy density, because of the higher electron density. Until an energy density of 175 J∙L-1, the gas flow rate has no visible effect on the removal efficiency. A further increase of the energy density results in a slower rise of the removal efficiency for a gas flow rate of 0.5 L∙min-1, compared to 2 L∙min-1. Indeed, an increase of the energy density from 150 to 350 J∙L-1 results in an increase of the removal efficiency from 81 % (0.5 L∙min-1) and 82 % (2.0 L∙min-1) to 92 % (0.5 L∙min-1) and 97 % (2.0 L∙min-1), respectively. So, if more than 80 % of TCE has to be removed in polluted air, it is better to 62 operate at higher gas flow rates to minimize the energy to be supplied per unit of gas volume. Moreover, more polluted air can be treated per unit of time when operating at a higher gas flow rate. Actually, the increase of the removal efficiency at higher gas flow rates was not expected. A higher residence time should increase the collision probability for electron impact reactions and for reactions between VOCs and plasma generated radicals. However, the measurement results in Figure 39 are not very accurate, due to the overlap of the 95 % confidence interval for several measurement values, and could explain the unexpected trend in the curve. 0.5 L/min 2.0 L/min 100 Removal efficiency (%) 90 80 70 60 50 40 0 200 400 600 Energy density (J/L) 800 1000 Figure 39. TCE removal efficiency as function of the energy density, for a gas flow rate of 0.5 L∙min-1 and 2.0 L∙min-1 (dry air, CTCE = 500 ppm, T = 293 K, atmospheric pressure) The increase in energy density also leads to an increase of the selectivity towards oxidation products CO and CO2 (Figure 40). Nevertheless, the COx selectivity remains low and did not exceeded 31 %. This means that the main part of TCE is decomposed towards chlorinated byproducts phosgene, TCAA and DCAC. As previously discussed, some of these by-products are more toxic than TCE itself and have to be avoided. The influence of the gas flow rate on the COx selectivity is not obvious. At low energy density, the COx selectivity is around 4 % higher when operating at 0.5 L∙min-1. At an energy density of 300 J∙L-1, the difference in COx selectivity between both gas flow rates becomes smaller and the 95 % confidence intervals start to overlap. The increase in COx formation can be explained by the higher residence time when decreasing the gas flow rate. The highest COx selectivity is obtained for a gas flow rate of 0.5 L∙min-1 due to the higher energy density at which sparking occurs. A lower gas flow rate also resulted in a higher CO2 selectivity due to the higher residence time. However, the difference in CO2 selectivity is very small. The 95 % confidence interval is not visible in the curves of the CO2 selectivity, due to the negligible standard deviation. An energy density of 1050 J∙L-1 and a gas flow rate of 0.5 L∙min-1 resulted in a maximal CO2 selectivity of 6 %. In order to increase the COx selectivity of the TCE abatement process, a NTP in 63 combination with a catalyst in a PPC configuration will be investigated. This will be discussed later. COx selectivity (0.5 L/min) COx selectivity (2.0 L/min) CO2 selectivity (0.5 L/min) CO2 selectivity (2.0 L/min) 35 30 Selectivity (%) 25 20 15 10 5 0 0 200 400 600 Energy density (J/L) 800 1000 Figure 40. COx and CO2 selectivity of the TCE abatement process as function of the energy density, for a gas flow rate of 0.5 L∙min-1 and 2.0 L∙min-1 (dry air, CTCE = 0 ppm, T = 294 K, atmospheric pressure) Another interesting product to monitor during plasma-assisted TCE abatement is HCl. The presence of this compound indicates total oxidation via reaction x. In addition, the formation of HCl is wanted, since it can be easily removed from the outlet gas. A quantitative determination of HCl by FT-IR or MS is not possible, due to the absence of a standard. However, the influence of the gas flow rate on the formation of HCl can be visually observed by comparing FT-IR spectra for the same TCE conversion. The amount of HCl present in the outlet gas is observed by zooming in on the characteristic bands of HCl (3050 – 2700 cm-1), as illustrated in Figure 41. These characteristic bands indicate a small decrease of the produced HCl with an increase in gas flow rate from 0.5 to 2.0 L·min-1. This can be explained by the higher residence time, resulting in an increased formation of stable products. 64 2 L/min HCl 0.004 0.003 0.002 Absorbance (-) 0.5 L/min 0.001 3000 2900 2800 Wavenumber (cm-1) 0 2700 Figure 41. FT-IR spectra between 3050 and 2700 cm-1 of the plasma treated outlet gas for two gas flow rates, at a TCE conversion of 64 %. (dry air, CTCE = 500 ppm, T = 294 K, atmospheric pressure) Another harmful compound produced in the plasma reactor is ozone, formed by reaction between plasma generated oxygen radicals and molecular oxygen. The ozone outlet concentration is measured as a function of the energy density for both gas flow rates, as illustrated in Figure 42. A higher energy density leads to an increase in ozone concentration due to the increased production of active electrons in the plasma. There is no influence of the gas flow rate on the ozone outlet concentration. This determination was also obtained during the experiments with pure air, as discussed in 7.1. Ozone is well known to be a respiratory hazard having adverse effects on human health. Therefore, a lot of researchers investigated the use of plasma in combination with a catalyst that is able to decompose ozone into reactive oxygen radicals, which in turn enhances the oxidation of TCE towards CO and CO2. 65 0.5 L/min 2.0 L/min 700 Ozone concentration (ppm) 600 500 400 300 200 100 0 0 200 400 600 Energy density (J/L) 800 1000 Figure 42. Ozone outlet concentration as a function of the energy density, for a gas flow of 0.5 L∙min -1 and 2.0 L∙min-1 (dry air, CTCE = 500 ppm, T = 294 K, atmospheric pressure) The formation of chlorinated by-products (DCAC, phosgene, HCl, TCAA, Cl2) during TCE abatement has been proven in 8.1 based on FT-IR and MS. The production of DCAC and phosgene will be studied in more detail due to its toxicity. The influence of the gas flow rate on the formation of DCAC and phosgene can be visually observed by comparing FT-IR spectra for the same TCE conversion. The formation of DCAC is investigated by zooming in on the characteristic bands around 740 cm-1, as shown in the right hand side of Figure 43. A higher residence time resulted in a decrease of the DCAC formation, due to the improved oxidation as mentioned above. For the study of phosgene is zoomed in on the characteristic band at 850 cm1 (Figure 43, left). Here, an increase of the residence time resulted in a small increase of the phosgene production. This was not expected and could not be explained. 0.5 L/min 0.07 2 L/min DCAC 0.06 0.05 0.03 0.02 0.05 Absorbance (-) 0.04 0.04 0.03 0.02 phosgene 0.01 0.01 0 0 765 755 745 735 725 Wavenumber (cm-1) 715 Absorbance (-) 2 L/min 0.5 L/min 0.06 875 865 855 845 835 Wavenumber (cm-1) 825 Figure 43. FT-IR spectra between 770 – 715 and 875 – 825 cm-1 of the plasma treated outlet gas for two gas flow rates, at a TCE conversion of 64 %. (dry air, CTCE = 500 ppm, T = 294 K, atmospheric pressure) 66 Influence of humidity The effect of humidity on TCE decomposition is also investigated, and is of great interest because water plays an important role in the plasma chemistry. Water limits the electron density due to its electronegative character, thereby inhibiting the formation of active plasma species [25]. The humidity of the gas inlet is adjusted by passing the gas through a H2O containing bubbling bottle, controlled by a mass flow controller. Seven different values of humidity were investigated. During the experiments, it was noted that brown/yellow spots were deposited on the spherical surface segments on the anode plate of the reactor. This deposition was formed as a result of the humidity since it was only visible during the experiments at 50 and 80 % RH. The spots led to an increase of the resistance in the electric circuit, thereby reducing the current through the plasma at a constant voltage. The latter negatively influenced the TCE abatement. Therefore, the anode plate was cleaned after each experiment. The brown/yellow spots on the anode plate of the reactor are illustrated in Figure 44. Figure 44. Anode plate of the plasma reactor profiled with spherical surface segments. Left: spots deposited after performing a TCE abatement experiment at a relative humidity of 80 %. Right: anode plate after cleaning. Figure 45 shows the humidity effect on the TCE removal efficiency. For an energy density higher than 80 J·L-1, a relative humidity of 15 % resulted in the highest removal efficiency. A further increase of the humidity resulted in a decrease in removal efficiency. For an energy density of 80 J·L-1, the removal efficiency drops by ± 17 % as the humidity increases from 15 % to 80 %. A relative humidity between 0 - 10 % has no significant influence on the TCE abatement. 67 The humidity effect on TCE abatement can be explained by looking at the decomposition reactions of water in plasma [25], shown below. 𝐻2 𝑂 + 𝑒 − → 𝐻 + 𝑂𝐻 + 𝑒 − ( 68 ) + 3 𝐻2 𝑂 + 𝑁2 (𝐴 ∑ ) → 𝑁2 + 𝐻 + 𝑂𝐻 ( 69 ) 𝑢 𝐻2 𝑂 + 𝑂 → 2 𝑂𝐻 ( 70 ) Water decomposes into OH radicals that possess a stronger oxidation power than other oxidants such as oxygen and peroxyl radicals, resulting in an increase of the TCE removal. On the other hand, water has a negative effect on TCE abatement since OH radicals strongly react with ClO and oxygen radicals via 𝑂𝐻 + 𝑂 → 𝑂2 + 𝐻 ( 71 ) 𝑂H + ClO → 𝐻𝐶𝑙 + 𝑂2 ( 72 ) Since ClO and oxygen radicals significantly decompose TCE, a reduced concentration of these radicals by OH leads to a suppression of the removal efficiency [110, 119]. In addition, water negatively influences TCE removal due to its electronegative characteristics. Higher humidity lowers the collision frequency between electrons and molecules (water, TCE, O2, …), thereby limiting the formation of active plasma species such as OH and O radicals. The latter was confirmed by Ge et al. [109], who investigated the effect of relative humidity on the relative production of OH radicals. Depending on the humidity level of polluted air, the presence of water leads to an enhancement or inhibition of the removal efficiency. When looking at Figure 45, the enhancement and inhibition effect seem to balance each other out at a humidity level between 15 – 20 %. It should be noted that humidity negatively influenced the stability of the plasma. For low energy density, an increase of the humidity level resulted in a reduction of the amount of cathode pins that emitted purple light. This can be explained by the electron capturing behavior of water, impeding the formation of stable plasma between the electrodes. For an energy density until 80 J·L-1, this explains why the removal efficiency at a humidity of 10 and 15 % RH is lower than in case of 2.8 and 5 % RH. A decrease of the number of active plasmas leads to a reduction of the active reaction volume and results in a decrease of the removal efficiency. At higher energy density, the whole interelectrode gap is filled with plasma due to the higher electron density. 68 2.8% RH 5% RH 10% RH 20% RH 50% RH 80% RH 15% RH 100 90 Removal efficiency (%) 80 70 60 50 40 30 20 10 0 0 50 100 150 200 Energy density (J/L) 250 300 350 Figure 45. TCE removal efficiency as function of the energy density for for different humidity levels. (humid air, CTCE = 500 ppm, Q = 2 L·min-1, T = 294.5 K, atmospheric pressure) The COx selectivity of the removal process as function of energy density is shown in Figure 46, for different humidity levels. An increase of the energy density leads to a higher COx selectivity. Moreover, the humidity also has a positive effect on the COx selectivity and can be explained by the strong oxidizing power of OH radicals. An increase of the humidity from 5 to 80 % RH led to a shift in COx selectivity from 8.5 to 18.5 %, at an energy density of 75 J·L-1. However, for all experiments, the COx selectivity remained low. Even at a humidity of 80 % RH, the COx selectivity did not exceed 20 %, meaning that TCE is mainly decomposed into chlorinated by-products. Noteworthy is the significant difference in COx selectivity when comparing a humidity of 2.8 and 5 %. A possible explanation for these results is that the experiments with humid air (RH > 2.8 %) were carried out after the plasma reactor was cleaned. The presence of dust or deposits on the electrodes may cause a reduction in performance of the reactor, leading to a lower COx selectivity. However, during cleaning there were no visible deposits present on the electrodes. Energy density nor humidity had an effect on the CO/CO2 ratio, which ranged between 3.5 and 5. 69 2.8% RH 20% RH 5% RH 50% RH 10% RH 80% RH 15% RH 20 18 COx selectivity (%) 16 14 12 10 8 6 4 2 0 0 50 100 150 200 Energy density (J/L) 250 300 350 Figure 46. COx selectivity of the TCE abatement process as function of the energy density for different humidity levels. (humid air, CTCE = 500 ppm, Q = 2 L·min-1, T = 294.5 K, atmospheric pressure) Humidity also has a positive effect on the formation of HCl, as shown in Figure 47. The FTIR spectrum of the outlet gas show a significant increase of the characteristic bands of HCl with increasing humidity. Only for a relative humidity of 50 %, the presence of HCl was not observed. The absence of HCl is hard to believe, since hydroxyl radicals react with ClO radicals towards HCl and O2 via (72). A reason for this phenomenom can be that the characteristic bands of HCl are interfered with a band of water in the FT-IR spectrum. The reference spectrum of water (Appendix, Figure 83) shows a significant IR absorption band between 3600 and 3000 cm-1. During the experiments at high humidity (> 50 % RH), it was difficult to keep the relative humidity stable. Due to this instability, water was present in the background spectrum and this pulled down/up the region where HCl absorbs infrared. This interference could not be removed by the water compensation method in OPUS and possibly explains why the characteristic bands of HCl are not visible in the outlet spectrum at 50 % RH. 70 5% RH 10% RH 20% RH 50% RH 0.008 HCl 0.004 Absorbance (-) 0.006 0.002 3000 0.000 2700 2900 2800 Wavenumber (cm-1) Figure 47. FT-IR spectra between 3050 and 2700 cm-1 of the plasma treated outlet gas for different humidity levels, at a TCE conversion of 60 %. (humid air, CTCE = 500 ppm, Q = 2 L·min-1, T = 294.5 K, atmospheric pressure) The influence of humidity on the ozone outlet concentration is illustrated in Figure 48. Just as in the experiments with pure air, an increase of the humidity leads to a lower ozone outlet concentration. 2.8% RH 20% RH 5% RH 50% RH 10% RH 80% RH 15% RH 450 ozone concentration (ppm) 400 350 300 250 200 150 100 50 0 0 50 100 150 200 Energy density (J/L) 250 300 350 Figure 48. Ozone outlet concentration as function of the energy density for different humidity levels. (humid air, CTCE = 500 ppm, Q = 2 L·min-1, T = 294.5 K, atmospheric pressure) Humidity also influences the formation of DCAC and phosgene. Under humid conditions, DCAC formation is suppressed when comparing the FT-IR spectra of the outlet gas for different 71 humidity levels (Figure 49). This effect was also reported by other researchers [71, 110] and can be explained as follows. DCAC can be produced by oxidation of TCE with OH or ClO radicals via the following reactions [63, 110]. C2 HCl3 + ClO → CHCl2 COCl + HCl k = 1.66 · 10−13 cm3 molecules −1 s−1 ( 73 ) C2 HCl3 + OH → CHCl2 COCl + H k = 2.4 · 10−14 cm3 molecules −1 s−1 ( 74 ) Based on reaction (74), an increase of the DCAC production is expected under humid conditions. However, OH radicals strongly react with ClO radicals towards HCl and O2 (reaction (72)), leading to a suppression of the DCAC production. The rate of reaction (73) is one order higher than reaction (74) and will thus determine the total production of DCAC. ClO radicals also play an important role in the formation of phosgene via 𝐶2 HCl3 + ClO → COCl2 + CHCl2 ( 75 ) A decreased formation of phosgene with increasing humidity would be expected due to the suppression of ClO radicals by OH radicals. However, the results of the experiments show an enhanced production of phosgene when looking at the right hand side of Figure 49. The enhancement is rather low and can be explained by reaction of OH radicals with the carboncarbon double bond of TCE leading to CHCl(OH)-CCl2 radicals [71]. This unstable intermediate further react with O2 towards peroxyl radicals and transform into chloroethoxyl radicals after radical coupling. The latter radicals can be further decomposed towards phosgene. An increased formation of phosgene was also observed by Nguyen Dinh et al. [71], who investigated the production of TCE degradation products in dry and humid air in a multi-pinto-plate reactor. 20% RH DCAC 80% RH 20% RH 0.09 0.06 50% RH 0.08 80% RH 0.07 0.05 0.04 0.03 0.06 Absorbance (-) 50% RH 0.07 0.05 0.04 0.03 0.02 phosgene 0.02 0.01 0.01 0 0 765 755 745 735 725 Wavenumber (cm-1) 715 Absorbance (-) 5% RH 5% RH 875 865 855 845 835 Wavenumber (cm-1) 825 Figure 49. FT-IR spectra between 770 – 715 and 875 – 825 cm-1 of the plasma treated outlet gas for different humidity levels, at a TCE conversion of 60 %. (humid air, CTCE = 500 ppm, Q = 2 L·min-1, T = 294.5 K, atmospheric pressure) 72 Influence of TCE The effect of the TCE inlet concentration on the abatement process is studied since the VOC concentration in industrial waste gases strongly varies. The experiments were performed with dry air (2.8 % RH), and the TCE concentration was varied between 250 and 750 ppm. Figure 50 shows the TCE removal efficiency as function of the energy density for three different TCE inlet concentrations. The removal efficiency decreases with increasing TCE concentration for an energy density lower than 250 J·L-1, and can be explained as follows. A higher amount of TCE molecules causes a noticeable difference in gas composition in the plasma reactor. Each TCE molecule shares fewer electrons and reactive plasma species, thereby reducing the probability of reaction between these species and a certain TCE molecule. Different researchers [120-125] who investigated the abatement of VOCs in NTP confirmed this effect. At an energy density of 250 J·L-1 or more, the effect of the TCE concentration on the TCE removal efficiency is not visible anymore. The concentration of electrons and active species is so high that it has no influence on the removal efficiency. 250 ppm TCE 500 ppm TCE 750 ppm TCE 100 Removal efficiency (%) 90 80 70 60 50 40 30 0 200 400 600 Energy density (J/L) 800 1000 Figure 50. TCE removal efficiency as function of the energy density for different TCE inlet concentrations. (dry air, Q = 0.5 L·min-1, T = 294 K, atmospheric pressure) Figure 51 shows the selectivity of the TCE abatement process towards CO and CO2. The COx selectivity increases linearly with the energy density and is strongly influenced by the TCE inlet concentration. At 250 ppm TCE, a COx selectivity of almost 50 % is reached, while for the higher concentrations tested the COx selectivity remained below 31 %. The production of CO and CO2 is mainly determined by the amount of atomic oxygen present in the plasma reactor. 73 However, atomic oxygen is also an important TCE decomposing compound (reactions (47-49)). Since a higher TCE inlet concentration leads to a higher amount of decomposed TCE molecules, the atomic oxygen concentration in the reactor decreases with an increasing TCE concentration. Magureanu et al. [125] investigated the influence of the initial concentration on the TCE removal process in a dielectric barrier discharge, and also observed this effect. 250 ppm TCE 500 ppm TCE 750 ppm TCE 50 COx selectivity (%) 40 30 20 10 0 0 200 400 600 Energy density (J/L) 800 1000 Figure 51. COx selectivity of the TCE abatement process as function of the energy density for different TCE inlet concentrations. (dry air, Q = 0.5 L·min-1, T = 294 K, atmospheric pressure) The influence of the initial TCE concentration on the formation of HCl is shown in Figure 52. A higher initial TCE concentration resulted in an increase of the HCl production, when the same amount of TCE is converted (240 ppm). 250 ppm TCE 500 ppm TCE 750 ppm TCE HCl 0.005 0.003 0.002 Absorbance (-) 0.004 0.001 3050 3000 2950 2900 2850 2800 Wavenumber (cm-1) 2750 0 2700 Figure 52. FT-IR spectra between 3050 and 2700 cm-1 of the plasma treated outlet gas for TCE inlet concentrations, at a conversion of 240 ppm TCE. (dry air, Q = 0.5 L·min-1, T = 294 K, atmospheric pressure) 74 The TCE inlet concentration also affects the ozone formation in the plasma reactor, as shown in Figure 53. A reduction of the TCE concentration from 750 to 500 ppm resulted in an increase of the O3 outlet concentration from 252 to 330 ppm, when operating at 250 J·L-1. A further reduction of the TCE concentration to 250 ppm led to a further increase towards 448 ppm. This effect can be explained by the competition between TCE and O2 to react with oxygen radicals, as discussed in 7.3. 250 ppm TCE 500 ppm TCE 750 ppm TCE 1000 ozone concentration (ppm) 900 800 700 600 500 400 300 200 100 0 0 200 400 600 Energy density (J/L) 800 1000 Figure 53. Ozone outlet concentration as function of the energy density for different TCE inlet concentrations. (dry air, Q = 0.5 L·min-1, T = 294 K, atmospheric pressure) The amount of DCAC and phosgene present in the outlet gas, for different TCE inlet concentrations, is shown in Figure 54. The FT-IR spectra were monitored at a constant amount of converted TCE (240 ppm) to compare these spectra. The TCE inlet concentration negatively influences the formation of DCAC and phosgene. This was expected since an increase of the TCE concentration led to an increase of the selectivity towards CO and CO2, as discussed above. From this it can be concluded that NTP is most suited for the abatement of low concentrated TCE gases. 75 0.05 250 ppm TCE 500 ppm TCE 750 ppm TCE DCAC Phosgene 0.14 0.04 0.02 0.1 Absorbance (-) 0.03 0.12 0.08 0.06 Absorbance (-) 250 ppm TCE 500 ppm TCE 750 ppm TCE 0.04 0.01 0.02 0 765 755 745 735 725 Wavenumber (cm-1) 715 0 875 865 855 845 835 Wavenumber (cm-1) 825 Figure 54. FT-IR spectra between 770 – 715 and 875 – 825 cm-1 of the plasma treated outlet gas for different TCE inlet concentrations, at a conversion of 240 ppm TCE. (dry air, Q = 0.5 L·min-1, T = 294 K, atmospheric pressure) 76 9 Plasma-catalytic TCE abatement The plasma-assisted experiments showed that TCE can be removed by NTP without the addition of considerable energy. However, the application of NTP for TCE abatement is impeded by low COx selectivity due to the formation of polychlorinated compounds (DCAC, TCAA, phosgene), which can be more toxic than TCE itself. Moreover, oxygen radicals generated in the plasma quickly react with molecular oxygen to produce ozone. By placing a catalyst downstream of the discharge zone, O3 can be decomposed in reactive oxygen radicals, able to greatly improve the oxidation of TCE and its hazardous by-products. Different catalysts will be studied and compared based on its performance to decompose TCE into oxidation products at low energy input. The catalyst temperature is an important parameter that determines the rate constant of the removal reactions via the Arrhenius equation 𝑘 = 𝐴 · 𝑒 −𝐸𝐴/(𝑅𝑇) ( 76 ) with k Reaction constant [depends on reaction order] ( 77 ) A Pre-exponential factor [depends on reaction order] ( 78 ) Ea Activation energy [J·mol-1] ( 79 ) R Universal gas constant [J·(mol·K)-1] ( 80 ) T Temperature [K] ( 81 ) Based on this equation, the optimal catalyst temperature will be a tradeoff between increasing TCE removal/oxidation with increasing temperature, and decreasing energy input with decreasing temperature. Next to the catalyst temperature, the influence of humidity on the performance of the removal process will be investigated. Cerium oxide (CeO2) CeO2 is one of the most commonly used components in the three-way catalysts for purification of exhaust gases in cars [126]. CeO2 acts as an ‘oxygen store’ during the lean operation conditions, while it can provide oxygen for the oxidation of H2, CO and organic compounds. In addition, CeO2 is able to decompose ozone, due to the promoting role of Ce during oxygen dissociation [127, 128]. For all plasma-catalytic experiments, 0.5 g of CeO2 powder was introduced in the cylindrical glass reactor located in a temperature controlled oven. 77 9.1.1 Dry air experiments The first series of experiments are performed with TCE polluted dry air. The plasma is operated at an energy density of 40 and 80 J·L-1 and the catalyst temperate ranges between 100 – 300 °C. The choice for a low energy density in combination with a low catalyst temperature is to improve the energy efficiency of the plasma-catalytic system. The TCE abatement measurements were performed after thermal balance was reached. Figure 55 shows the TCE removal efficiency of the PPC experiments. The results of the plasma-alone experiment (performed at room temperature) are also shown to compare them with the PPC experiments. The error bars indicate the 95% confidence interval, based on the standard deviation of three measurements. The PPC system clearly enhanced the TCE abatement compared to the plasma-alone system, obtaining a value of 64 % (plasma-catalysis) and 51 % (plasma-alone) at 40 J·L-1. TCE abatement experiments were also performed in a catalyst-alone system. Regardless of the catalyst temperature, the TCE removal efficiency never exceeded 1 %. This means that the combination of NTP with CeO2 induces a synergetic effect on the removal efficiency. To evaluate the synergy in our process, a synergy factor f for TCE abatement is introduced as 𝑓𝑇𝐶𝐸 = (𝑟𝑒𝑚𝑜𝑣𝑎𝑙 𝑒𝑓𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑦)𝑝𝑙𝑎𝑠𝑚𝑎−𝑐𝑎𝑡𝑎𝑙𝑦𝑠𝑖𝑠 (𝑟𝑒𝑚𝑜𝑣𝑎𝑙 𝑒𝑓𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑦)𝑝𝑙𝑎𝑠𝑚𝑎−𝑎𝑙𝑜𝑛𝑒 + (𝑟𝑒𝑚𝑜𝑣𝑎𝑙 𝑒𝑓𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑦)𝑐𝑎𝑡𝑎𝑙𝑦𝑠𝑡−𝑎𝑙𝑜𝑛𝑒 ( 82 ) Thus, the synergy factor gives the relation of the TCE removal efficiency for plasma-catalysis with respect to the sum of its individual values for plasma and catalyst alone conditions. If this value exceeds 1, a synergetic effect is observed. Table 7 shows that the synergy factor for TCE abatement is in the range of 1.17 – 1.29. The synergy factor is slightly lower when operating at an energy density of 80 J·L-1. This can be explained by the higher TCE abatement with increasing energy density. At 80 J·L-1, NTP is able to decompose 65 % of TCE. This means that only 35 % of the TCE is available for further decomposition by the catalyst. While in case of an energy density of 40 J·L-1, still 50 % of the initial TCE is available for further degradation. The effect of the catalyst temperature on the synergy factor is much smaller. The small decrease of the synergy factor with increasing temperature can be possibly explained by little deactivation of the catalyst. All PPC experiments were started at a catalyst temperature of 100 °C and the temperature was further increased in steps of 50 °C. So, during the performance of the experiment at 300 °C it could be that a part of the active sites were poisoned by TCE degradation products, formed during previous experiments, and thereby inhibiting the decomposition of TCE. 78 Table 7. Synergy factors for plasma-catalytic TCE abatement Temperature [°C] 100 150 200 250 300 90 80 fTCE 40 J·L-1 1.27 1.29 1.26 1.25 1.23 80 J·L-1 1.20 1.22 1.20 1.18 1.17 40 J/L 80 J/L Removal efficiency (%) 70 60 50 40 30 20 10 0 NTP PPC 100°C PPC 150°C PPC 200°C PPC 250°C PPC 300°C Figure 55. TCE abatement in a plasma-catalytic (CeO2) and a plasma-alone system for different temperatures, at an energy density of 40 and 80 J·L-1. (dry air, CTCE = 500 ppm, Q = 0.5 L·min-1, atmospheric pressure) Figure 56 shows the selectivity of the TCE abatement process towards CO, CO2 and chlorinated by-products for the plasma-alone and PPC system. Only the results of the experiments at an energy density of 40 J·L-1 are displayed. An increase of the energy density to 80 J·L-1 had no significant effect on the COx selectivity. The PPC system at a low temperature increased the COx selectivity compared to the plasma-alone system. Indeed, a catalyst temperature of 100 °C resulted in a COx selectivity of 14.3 %, compared to 9.3 % in NTP. When increasing the catalyst temperature to 300 °C, the COx selectivity further increases to 60 % due to the activated ozone dissociation reaction on the catalyst surface. 79 Cl by-products 90 CO 80 CO2 Selectivity (%) 70 60 50 40 30 20 10 0 NTP PPC 100°C PPC 150°C PPC 200°C PPC 250°C PPC 300°C Figure 56. The selectivity of the TCE removal process towards CO, CO2 and chlorinated by-products in a plasmacatalytic (CeO2) and a plasma-alone system for different temperatures, at an energy density of 40 J·L-1. (dry air, CTCE = 500 ppm, Q = 0.5 L·min-1, atmospheric pressure) The increased COx selectivity in the PPC system can be explained by the decomposition of ozone on the catalyst surface. Ozone can be cleaved at the CeO2 surface, leading to the formation of active oxygen species via [25, 129] 𝑂3 + ∗ → O2 + O∗ ( 83 ) 𝑂3 + O∗ → O2 + O2 ∗ ( 84 ) The oxygen species will desorb and react with chlorinated by-products towards oxidation products CO, CO2, HCl and Cl2, explaining the increased COx selectivity. The ozone decomposing ability of CeO2 is clearly visible in Figure 57, that shows the ozone concentration in the outlet gas of the plasma-alone and the PPC system. The use of a catalyst (at 100 ° C) downstream of the plasma (operated at 40 J·L-1) resulted in a decrease of the ozone outlet concentration from 119 to 74 ppm, compared to the plasma-alone system. An increase of the catalyst temperature further decreased the ozone concentration, due to the activated ozone dissociation on the catalyst. The experiments at an energy density of 80 J·L-1 resulted in a higher ozone production, due to the presence of more electrons in the plasma when operating at a higher energy density. 80 175 40 J/L 80 J/L O3 concentration (ppm) 150 125 100 75 50 25 0 NTP PPC 100°C PPC 150°C PPC 200°C PPC 250°C PPC 300°C Figure 57. Ozone outlet concentration of the plasma treated TCE gas in a plasma-catalytic (CeO2) and a plasma-alone system for different temperatures, at an energy density of 40 J·L-1. (dry air, CTCE = 500 ppm, Q = 0.5 L·min-1, atmospheric pressure) As previously discussed, the use of NTP in combination with a catalyst clearly reduced the selectivity towards chlorinated by-products. It is interesting to identify the chlorinated byproducts and to investigate whether new products are formed in the PPC system. Nguyen Dinh et al. [130] studied the removal of TCE in a PPC system using Ce-Mn based oxides as catalyst, and detected the presence of CCl4 (794 cm-1) and HCCl3 (773 cm-1) in the outlet FT-IR spectrum of all PPC experiments. However, when zooming in on this specific region in the outlet spectrum of the PPC process, none of these absorption bands were visible. The comparison of the FT-IR outlet spectrum (Figure 58) of the plasma-alone and PPC system confirms the presence of the following chlorinated by-products: phosgene, DCAC, TCAA and HCl. The formation of Cl2 is identified based on the MS spectrum of the outlet gas. The production of phosgene, DCAC and HCl will be discussed more in detail. 81 TCE inlet NTP PPC-100°C 0.2 0.18 0.16 0.12 0.1 0.08 Absorbance (-) 0.14 0.06 0.04 0.02 0 2900 2700 2500 2300 2100 1900 1700 1500 Wavenumber (cm-1) 1300 1100 900 700 Figure 58. FT-IR spectra between 700 and 3050 cm-1 of TCE inlet (black), plasma-alone (red) and plasma-catalytic (blue) treated TCE gas at an energy density of 40 J·L-1 (dry air, CTCE = 500 ppm, Q = 0.5 L∙min-1, Tplasma = 293 K, atmospheric pressure) Figure 59 shows the characteristic IR bands of HCl in the outlet FT-IR spectrum of the plasmaalone and PPC system at different catalyst temperatures. The use of CeO2 (at 100 °C) in combination with NTP led to an increased formation of HCl, compared to the plasma-alone system. This can be explained by the production of oxygen radicals on the catalyst surface, enhancing the rate of the following oxidation reaction C2 HCl3 + 4O → 2CO2 + HCl + Cl2 ( 85 ) Operating at a higher catalyst temperature further increased the HCl production, due to activation of the catalyst. 82 NTP PPC-200°C PPC-100°C PPC-250°C PPC-150°C PPC-300°C HCl 0.04 0.02 Absorbance (-) 0.03 0.01 3050 3000 2950 2900 2850 Wavenumber (cm-1) 2800 2750 0 2700 Figure 59. FT-IR spectra between 3050 and 2700 cm-1 of the plasma and plasma-catalytic treated outlet gas for different temperatures, at a TCE conversion of 64 %. (dry air, CTCE = 500 ppm, Q = 0.5 L·min-1, Tplasma = 293 K, atmospheric pressure) As expected, the addition of a catalyst resulted in a decrease of the DCAC production (Figure 60, left). An increasing catalyst temperature further enhanced the decomposition of DCAC. However above a catalyst temperature of 200 °C, this effect was strongly reduced. Next to DCAC, researchers [71, 129, 130] also observed a decreased production of phosgene during TCE abatement in a plasma-catalytic system when using metal oxides as catalyst. However, Figure 60 (right) indicates that the addition of a catalyst (at 100 °C) to the plasma does not influence the phosgene production. However, an increase of the catalyst temperature slightly enhanced the formation of phosgene. This was unexpected since phosgene should be decomposed by oxygen radicals via 𝐶𝑂𝐶𝑙2 + O → 𝐶𝑂𝐶𝑙 + 𝐶𝑙𝑂 ( 86 ) A possible explanation can be that reaction (86) is inhibited due to competition with other oxidation reactions, such as the oxidation of DCAC, TCAA and TCE. In addition, the increased production of oxygen species on the catalyst surface with increasing catalyst temperature will enhance the production of ClO radicals, which can further react towards phosgene. 𝐶𝑙2 + O → Cl + ClO ( 87 ) 𝐶2 HCl3 + ClO → COCl2 + CHCl2 ( 88 ) However, this explanation could not be justified due to the absence of information about the rate constants of the above reactions. 83 NTP PPC-100°C PPC-150°C PPC-200°C PPC-250°C PPC-300°C 0.04 0.03 0.02 0.1 0.08 0.06 0.04 0.01 0.02 phosgene 0 765 755 745 735 725 Wavenumber (cm-1) 715 Absorbance (-) 0.05 DCAC Absorbance (-) NTP PPC-100°C PPC-150°C PPC-200°C PPC-250°C PPC-300°C 0 875 865 855 845 835 Wavenumber (cm-1) 825 Figure 60. FT-IR spectra between 770 – 715 and 875 – 825 cm-1 of the plasma-alone and plasma-catalytic treated TCE gas for different catalyst temperatures, at a TCE conversion of 64 %. (dry air, CTCE = 500 ppm, Q = 0.5 L·min-1, Tplasma = 293 K, atmospheric pressure) 9.1.2 Influence of humidity The effect of humidity on the performance of the PPC removal process is studied by performing experiments with TCE polluted air at different humidity levels. The plasma-alone experiments (8.3) already showed the positive effect of humidity on the COx selectivity due to the strong oxidizing power of hydroxyl radicals. Four different relative humidity levels (10, 20, 50 and 80 % RH) were studied and the experiments were performed at an energy density of 280 and 400 J·L-1. The reason why such high energy densities were used is because of the negative effect of humidity on the stability of the plasma. At low energy density, an increase of the humidity resulted in a reduction of the amount of cathode pins that emitted purple light. This can be explained by the electron capturing behavior of water, impeding the formation of stable plasma between the electrodes. So to be able to compare the results of the experiments at different humidity levels it is important that during each experiment the same amount of electrodes light up. Tests showed that all 10 electrodes light up at an energy density higher than 250 J·L-1, regardless of the humidity. The effect of humidity on the TCE removal efficiency is shown in Figure 61. The experiments were performed at 280 and 400 J·L-1, and the catalyst temperature was set on 200 °C. At first sight, an increase of the humidity leads to a small decrease of the removal efficiency. Indeed, an increase of the humidity from 2.8 to 80 % RH led to a decrease of the removal efficiency from 95.5 to 86.5 %. The adverse effect of humidity on the TCE removal efficiency is also observed by other researchers [107, 132, 133], and can be partly ascribed to a decrease in catalytic ozone decomposition under humid conditions (Figure 63), since the amount of converted ozone is directly related to the concentration of newly formed active oxygen species over the catalyst surface. Another possible explanation is that the competitive adsorption of water also inhibits the adsorption of TCE, thereby reducing the catalytic removal of TCE. However, the latter explanation seems unlikely since the catalyst-alone experiments showed a 84 small enhancement of the TCE removal with increasing humidity. However, the removal efficiency of the catalyst-alone experiments was negligible and never exceeded 5 %. PPC 280 J/L PPC 400 J/L Removal efficiency (%) 100 90 80 70 60 0 10 20 30 40 50 Relative humidity (%) 60 70 80 Figure 61. TCE removal efficiency in a plasma-catalytic (CeO2) system as function of the relative humidity, at an energy density of 280 and 400 J·-1. (humid air, CTCE = 500 ppm, Q = 0.5 L·min-1, T = 294.5 K, atmospheric pressure) The influence of the humidity and catalyst temperature on the COx selectivity of the PPC system is plotted in Figure 62. The experiments were performed at an energy density of 280 J·L-1. The effect of water is rather complex and strongly depends on the catalyst temperature. At a catalyst temperature of 100 °C, humidity positively influences the COx selectivity. The COx selectivity is rather low and reaches a maximal value of 38 %, at 80 % RH. The enhanced TCE oxidation with increasing humidity can be explained by the strong oxidizing power of water. When looking at the COx selectivity at a catalyst temperature of 250 and 300 °C, water has a negative effect on the oxidation of TCE for a humidity higher than 50 % RH. This can be explained as follows. An increase of the temperature activates the catalyst resulting in an increase of the ozone decomposition rate on the catalyst surface. This effect is clearly visible in Figure 63. Ozone is decomposed in active oxygen species, enhancing the production of oxidation products CO and CO2. However an increase of the humidity inhibits the ozone formation via reaction (46) resulting in a decrease of active oxygen species on the catalyst surface. At low humidity (< 50 % RH), water has a positive effect on the COx selectivity due to the combination of strong oxidizing hydroxyl radicals and a high amount of ozone decomposed on the catalyst surface. So at a high catalyst temperature, the optimal humidity is a tradeoff between increasing hydroxyl radicals with increasing humidity, and increasing oxygen species produced by the catalyst with decreasing humidity. The importance of ozone is clearly visible when comparing the COx selectivity for dry air and humid air at 80 % RH. An increase of the catalyst temperature from 100 to 300 °C leads to an increase of the COx selectivity from 24 to 82 % (dry air) and 38 to 72 % (humid air at 80 %). The smaller increase at 80 % RH is caused by the inhibition of the ozone formation. The highest COx selectivity is 89 %, reached at a catalyst temperature of 300 °C and a humidity of 20 % RH. 85 PPC 100°C PPC 250°C 100 PPC 150°C PPC 300°C PPC 200°C 90 COx selectivity (%) 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 Relative humidity (%) 60 70 80 Figure 62. The selectivity of the TCE removal process towards COx in a plasma-catalytic (CeO2) system as a function of the relative humidity, at an energy density of 280 J·L-1. (humid air, CTCE = 500 ppm, Q = 0.5 L·min-1, T = 294.5 K, atmospheric pressure) PPC 280 J/L (100°C) PPC 400 J/L (100°C) PPC 280 J/L (150°C) PPC 400 J/L (150°C) PPC 280 J/L (200°C) PPC 400 J/L (200°C) 200 ozone concentration (ppm) 160 120 80 40 0 0 10 20 30 40 50 Relative humidity (%) 60 70 80 Figure 63. Ozone outlet concentration of the plasma-catalytic (CeO2) treated TCE gas as function of the relative humidity, for different temperatures and energy densities. (humid air, CTCE = 500 ppm, Q = 0.5 L·min-1, T = 294.5 K, atmospheric pressure) The influence of humidity on the production of HCl is visualized in Figure 64. The left hand side shows the outlet FT-IR spectra between 2700 – 3050 cm-1 at a catalyst temperature of 100 °C for three different humidity levels. The spectra were measured at a removal efficiency between 86 – 89 %. No peaks were observed, indicating the absence of HCl in the treated outlet 86 gas. An increase of the catalyst temperature to 300 °C resulted in an enhancement of the HCl formation (Figure 64, right), except for a humidity of 80 % RH. This indicates that CeO2 enhances the formation of HCl (if the catalyst is activated), while water suppresses its formation. The latter was unexpected since the plasma-alone experiments showed the opposite effect. Humidity enhances the formation of HCl due to the temperature independent reaction between OH and ClO radicals [110]. 𝑂𝐻 + 𝐶𝑙𝑂 → 𝐻𝐶𝑙 + O2 k = 2.5 · 10-11 cm3 molecules −1 s−1 ( 89 ) However, the HCl production can be suppressed by the occurrence of reaction [133] 𝐻𝐶𝑙 + 𝑂𝐻 → 𝐻2 O + Cl k = 8.4 · 10-13 cm3 molecules −1 s−1 ( 90 ) At room temperature, the rate constant of the HCl consuming reaction is 2 orders of magnitude lower as the HCl production reaction, but can be increased with increasing temperature. Moreover, it is possible that CeO2 activates this HCl consuming reaction explaining the decrease of HCl formation with increasing humidity. However, this does not explain the absence of HCl at a catalyst temperature of 100 °C. 10% RH (300 °C) 50% RH (300 °C) 80% RH (300 °C) 0.014 0.012 0.012 0.01 0.01 0.008 0.006 0.008 0.006 0.004 0.004 0.002 0.002 0 3050 3000 2950 2900 2850 2800 2750 2700 Wavenumber (cm-1) Absorbance (-) 0.014 Absorbance (-) 10% RH (100°C) 50% RH (100 °C) 80% RH (100 °C) 0 3050 3000 2950 2900 2850 2800 2750 2700 Wavenumber (cm-1) Figure 64. FT-IR spectra between 3050 and 2700 cm-1 of the plasma-catalytic treated outlet gas for different humidity levels, at a catalyst temperature of 100 °C (left) and 300 °C (right). The spectra are measured at a TCE conversion between 86 – 89 %. (humid air, CTCE = 500 ppm, Q = 0.5 L·min-1, Tplasma = 294 K, atmospheric pressure) An increase of the humidity also suppresses the formation of DCAC, as illustrated in Figure 65. The left hand side shows the characteristic peak of DCAC in the FT-IR outlet spectrum for three humidity levels at a catalyst temperature of 100 °C. For a humidity of 80 % RH, the DCAC outlet concentration is three times higher than for a humidity of 10 %. This effect was also observed during the plasma-alone experiments (8.3), and can be explained by the decreasing formation of ClO with increasing humidity via reaction (89). ClO is an important radical for the decomposition of TCE into DCAC. 87 An increase of the catalyst temperature from 100 to 300°C (Figure 65, right) strongly activates the catalyst and resulted in a complete removal of DCAC that was formed in the NTP. 10% RH (100 °C) 10% RH (300 °C) 0.04 50% RH (100 °C) 0.04 50% RH (300 °C) 80% RH (100°C) 80% RH (300 °C) Absorbance (-) 0.02 0.02 0.01 0.01 0 0 765 755 745 735 725 Wavenumber (cm-1) Absorbance (-) 0.03 0.03 765 715 755 745 735 725 Wavenumber (cm-1) 715 Figure 65. FT-IR spectra between 770 and 715 cm-1 of the plasma-catalytic treated outlet gas for different humidity levels, at a catalyst temperature of 100 °C (left) and 300 °C (right). The spectra are measured at a TCE conversion between 86 – 89 %. (humid air, CTCE = 500 ppm, Q = 0.5 L·min-1, Tplasma = 294 K, atmospheric pressure) In contrast to DCAC, humidity enhances the production of phosgene in the PPC process. However, the increased phosgene formation with increasing humidity is quiet low, as can be seen in Figure 66. These results are consistent with the results of the plasma-alone experiments in 8.3. The outlet FT-IR spectra at a catalyst temperature of 300 °C show a strong reduction of the phosgene production, compared to 100 °C. This can be explained by the enhanced ozone decomposition on the catalyst surface leading to an increased concentration of active oxygen species. 10% RH (300 °C) 50% RH (300 °C) 80% RH (300 °C) 50% RH (100 °C) 0.07 0.07 0.06 0.06 0.05 0.05 0.04 0.03 0.02 Absorbance (-) 80% RH (100 °C) 0.04 0.03 0.02 0.01 0.01 0 875 865 855 845 835 Wavenumber (cm-1) 825 Absorbance (-) 10% RH (100 °C) 0 875 865 855 845 835 Wavenumber (cm-1) 825 Figure 66. FT-IR spectra between 875 and 825 cm-1 of the plasma-catalytic treated outlet gas for different humidity levels, at a catalyst temperature of 100 °C (left) and 300 °C (right). The spectra are measured at a TCE conversion between 86 – 89 %. (humid air, CTCE = 500 ppm, Q = 0.5 L·min-1, Tplasma = 294 K, atmospheric pressure) 88 Cryptomelane (K-OMS-2) A second mineral that is studied as potential ozone decomposing catalyst in the plasma-catalytic abatement of TCE is cryptomelane. This potassium manganese oxide mineral, with formula KMn8O16, is composed of 2 x 2 edge-shared MnO6 octahedral chains, which are corner connected to form one-dimensional tunnels of ca. 4.7 x 4.7 Ȧ2 (Figure 67). The synthetic counterpart of cryptomelane is known as octahedral molecular sieve (K-OMS-2). Due to the presence of manganese in different oxidation states within the framework of OMS materials and their ability to transfer oxygen, these materials are widely investigated as catalysts for partial and total oxidation reactions [134]. In addition, OMS-type catalysts have been proved to be a cost-effective and environmentally benign alternative to conventional catalysts for the oxidation of VOCs such as acetone [135] and ethyl acetate [136]. Figure 67. 2D dimensional projection of K-OMS-2 structure [137] For all (plasma-)catalytic experiments, 0.5 g of K-OMS-2 powder and 3 g of carborundum were introduced in the cylindrical glass reactor located in a temperature controlled oven. Before each experiment, K-OMS-2 was calcinated at 350 °C for 4 hours. 9.2.1 Influence of humidity TCE abatement is investigated at 150 °C with catalyst alone, NTP at ambient conditions and with a PPC system. Figure 68 shows the TCE removal efficiency in NTP and PPC system as function of the energy density. The PPC experiments were performed with dry (2.8 % RH) and humid (15 % RH) air to investigate the effect of humidity on the TCE abatement. Regarding the NTP experiment, the TCE abatement increases with energy density due to the formation of more energetic electrons, reaching a removal efficiency of 90 % at 250 J·L-1. The evolution of the TCE abatement as function of energy density in PPC experiments with dry air displays a similar behavior to the one observed for NTP alone, but are translated to higher values for a 89 given energy density. The TCE removal efficiency in the catalyst-alone system was very low and did not exceeded 3 %. The sum of the removal efficiency in NTP and catalyst-alone system is lower than the removal efficiency in the PPC system, which indicates a synergetic effect by combining both NTP and K-OMS-2 catalyst. The synergy factors of the PPC system for different energy densities are given in Table 8. An increase of the energy density resulted in lower values of the synergy factor since the removal efficiency is getting closer to its maximal value. Comparison of the synergy factors of dry and humid air shows a negative effect of humidity on the performance of the PPC system. An increase of the energy density from 40 to 200 J·L-1 resulted in a decrease of the synergy factor from 1.37 to 0.89. This means that the synergetic effect disappears with increasing energy density. This effect is also observable in Figure 68. In contrast, humidity has a positive effect on TCE abatement in the plasma-alone system. A possible explanation for the negative effect of humidity in the PPC system is the competitive adsorption of water, inhibiting the adsorption of TCE on the catalyst surface. Table 8. Synergy factors for plasma-catalytic (K-OMS-2) TCE abatement Energy density [J·L-1] fTCE dry air 1.60 1.37 1.18 - 40 80 100 150 200 PPC - dry NTP - dry 15 % RH 1.37 1.16 1.07 0.95 0.89 PPC - 15% RH NTP - 15% RH 100 Removal efficiency (%) 90 80 70 60 50 40 30 0 50 100 150 Energy density (J/L) 200 250 Figure 68. TCE removal efficiency in a plasma-alone and plasma-catalytic (K-OMS-2) system as function of the energy density, for two different humidity levels. (humid air, CTCE = 500 ppm, Q = 0.5 L·min-1, T = 295.5 K, atmospheric pressure) 90 Figure 69 shows the carbon mass-balance in terms of COx selectivity in function of energy density. The PPC system clearly improved the complete oxidation of TCE towards CO2. During the PPC experiments with dry air, a maximal CO2 selectivity of 47 % was obtained, while in NTP only 3 % could be reached. The increased CO2 selectivity in the PPC system indicates the ozone decomposing power of the catalyst. The decomposition of ozone on the catalyst can also be seen when looking at the ozone concentration of the outlet gas, shown in Figure 70. The ozone concentration of the plasma-catalytic treated outlet gas is very low, and never exceeded 3 ppm. In contrast, the ozone concentration of the plasma treated outlet gas is much higher and ranges between 50 and 350 ppm, depending on the energy density. COx - dry (PPC) COx - 15% RH (PPC) COx - dry (NTP) COx - 15% RH (NTP) CO2 - dry (PPC) CO2 - 15% RH (PPC) CO2 - dry (NTP) CO2 - 15% RH (NTP) 70 COx selectivity (%) 60 50 40 30 20 10 0 0 50 100 150 Energy density (J/L) 200 250 Figure 69. The selectivity of the TCE removal process towards COx in a plasma-alone and plasma-catalytic (K-OMS-2) system as function of the energy density, for two different humidity levels. (humid air, CTCE = 500 ppm, Q = 0.5 L·min1, T = 295.5 K, atmospheric pressure) For both the NTP and PPC experiments, humidity enhanced the COx selectivity. At 40 J·L-1, an increase of the humidity from 2.8 to 15 % resulted in an increase of the COx selectivity from 57 to 71 %. This is due to the oxidizing power of hydroxyl radicals formed in NTP. 91 PPC - dry PPC - 15% RH NTP - dry NTP - 15% RH 350 ozone concentration (ppm) 300 250 200 150 100 50 0 0 50 100 150 200 Energy density (J/L) 250 300 Figure 70. Ozone outlet concentration of the (plasma-)catalytic (K-OMS-2) treated TCE gas as function of the energy density, for two different humidity levels. (humid air, CTCE = 500 ppm, Q = 0.5 L·min-1, T = 294.5 K, atmospheric pressure) 9.2.2 Catalyst deactivation When looking at the evolution of the COx selectivity as function of energy density in Figure 69, something remarkable was noticed. For the NTP experiments, it can be seen that the CO x selectivity increased with the increase of the energy density, indicating that higher energy density promotes the conversion of TCE to total oxidation. This trend was also observed during the plasma-catalytic experiments with CeO2. However, in case of K-OMS-2, the opposite effect was observed. An increase of the energy density from 25 to 250 J·L-1 resulted in a decrease of the COx selectivity from 71 to 61 %. The most plausible explanation for this phenomenon is deactivation of the catalyst, since the energy density was increased in time. K-OMS-2 possesses strong adsorption properties due to the variable valence state for manganese in its structure [138]. However, adsorption is selective and depends on the adsorption enthalpy of the adsorbing species. In the ideal case, ozone is selective adsorbed and decomposed on the catalyst, increasing the total oxidation of TCE and chlorinated by-products formed in NTP. However, the decrease of the COx selectivity in time suggests poisoning of the catalytic sites with chlorinated by-products. In order to prove the deactivation of the catalyst the TCE abatement experiment was performed in the reverse direction. The PPC experiment was started at an energy density of 250 J·L-1, and was further decreased in steps of 25 J·L-1. The results of the reverse experiment are shown in Figure 71. As can be seen, the COx selectivity again decreases in function of time, indicating the deactivation of the catalyst. The reverse experiment took around 5 hours, and resulted in a decrease of the COx selectivity from 62 to 37 %. 92 COx - dry (normal) COx - dry (reverse) start 70 start COx selectivity (%) 60 50 40 30 20 10 0 0 50 100 150 Energy density (J/L) 200 250 Figure 71. The COx selectivity of the plasma-catalytic (K-OMS-2) experiment as function of the energy density, performed in the normal and reverse direction. (dry air, CTCE = 500 ppm, Q = 0.5 L·min-1, T = 295.5 K, atmospheric pressure) The deactivation of the catalyst is also visible in Figure 72. In this figure, the blue line shows the evolution of the TCE removal efficiency of the catalyst-alone system as a function of time. After 1 hour, a removal efficiency of 4.5 % was reached. After 5 hours of passing TCE through the catalyst, the TCE removal was measured again and resulted in a value of 3.3 % (red line). So during 5 hours of passing TCE through the catalyst, the removal efficiency dropped 1.2 %. During a second series of measurements, the catalyst-alone experiment was performed after the PPC experiments. The latter experiments took 5 hours and the removal efficiency in the catalyst-alone experiment now reached a value of only 1.4 % (green line). This value is halved compared to the removal efficiency of the catalyst-alone system (perfomed after 5 hours), and shows that the by-products formed in NTP are the most responsible for the deactivation of KOMS-2. 93 50 45 Removal efficiency (%) 40 35 Catalyst alone - dry (immediate) 30 Catalyst alone - dry (after 5 h) 25 20 Catalyst alone - dry (after PPC exp.) 15 10 5 0 0 500 1000 1500 2000 Time (s) 2500 3000 3500 Figure 72. The removal efficiency of the catalyst-alone system as function of time. A first experiment was performed immediately (blue line) and after 5 h of passing TCE through the catalyst (red line). A second experiment was executed after the PPC experiments (green line). (dry air, CTCE = 500 ppm, Q = 0.5 L·min-1, T = 295.5 K, atmospheric pressure) Fe3O4/K-OMS-2 This cryptomelane composite is synthesized to improve the TCE abatement to total oxidation, since Fe3O4 is known for its oxidizing properties [139]. The catalyst is produced by grafting Fe3O4 nanoparticles onto OMS-2 via a precipitation method, as explained in 6.4.1. The TCE abatement experiments were performed under the same conditions as the experiments with pure K-OMS-2 in order to compare the results. The TCE removal efficiency as function of the energy density is shown in Figure 73. Placing Fe3O4/K-OMS-2 downstream of the plasma source slightly enhanced the TCE abatement compared to the plasma-alone system. Operating at 40 J·L-1 resulted in an enhancement of 11 %, but this effect decreased with increasing energy density to only 3 % at 250 J·L-1. The catalyst-alone system resulted in a removal efficiency of 3.5 %, which indicates that the synergetic effect of the PPC system is negligible. The PPC system with pure K-OMS-2 on the other hand, shows a clear synergetic effect. The latter was already quantified by the synergy factors in 9.2.1. (Table 8). 94 PPC (Fe3O4/K-OMS-2) PPC (K-OMS-2) NTP 100 Removal efficiency (%) 90 80 70 60 50 40 30 0 50 100 150 Energy density (J/L) 200 250 Figure 73. TCE removal efficiency in a plasma-alone and plasma-catalytic system with K-OMS-2 and Fe3O4/K-OMS-2 as function of the energy density. (dry air, CTCE = 500 ppm, Q = 0.5 L·min-1, T = 295.5 K, atmospheric pressure) Figure 74 shows the carbon mass-balance in terms of COx selectivity as function of the energy density. In contrast to the TCE removal efficiency, Fe3O4/K-OMS-2 gives better results in terms of COx selectivity compared to K-OMS-2. Operating at 40 J·L-1 resulted in a COx selectivity of 74 and 57 % for Fe3O4/K-OMS-2 and K-OMS-2, respectively. This indicates that the addition of Fe3O4 to K-OMS-2 results in a compromise between increasing COx selectivity and decreasing TCE removal. When looking at the evolution of the COx selectivity as function of the energy density, the same decreasing trend as in case of K-OMS-2 is visible. This can again be explained by the deactivation of the catalyst by chlorinated intermediates formed in NTP. An increase of the energy density from 40 to 150 J·L-1 resulted in a decrease of the COx selectivity from 74 to 62 %. 95 Figure 74. The selectivity of the TCE removal process towards COx in a plasma-alone and plasma-catalytic system with K-OMS-2 and Fe3O4/K-OMS-2 as function of the energy density. (dry air, CTCE = 500 ppm, Q = 0.5 L·min-1, T = 295.5 K, atmospheric pressure) The high COx selectivity in the PPC system with Fe3O4/K-OMS-2 clearly affects the concentration of hazardous chlorinated by-products in the treated outlet gas, as shown in Figure 75. The HCl concentration in the Fe3O4/K-OMS-2 system is slightly increased compared to KOMS-2, while the formation of DCAC and phosgene is more inhibited for Fe3O4/K-OMS-2. During the analysis of the FT-IR outlet spectra, two new bands at 794 and 772 cm-1 have been detected in the PPC experiments with K-OMS-2 and Fe3O4/K-OMS-2. These bands can be ascribed to the C-Cl vibrations of CCl4 and CHCl3 (chloroform), when comparing with reference compound spectra of NIST (Appendix, Figure 84 and 85). The bands of these two compounds were not visible in the outlet spectra of the plasma-alone and PPC system with CeO2. CCl4 and CHCl3 may be likely formed through carbon-carbon cleavage of DCAC and TCAA. This explains the larger decrease of the DCAC outlet concentration compared to phosgene, when comparing the PPC and plasma-alone experiments. 96 Fe3O4/K-OMS-2 K-OMS-2 NTP Fe3O4/K-OMS-2 K-OMS-2 phosgene NTP 0.04 0.1 0.08 Absorbance (-) 0.04 0.01 1100 1090 1080 1070 1060 Wavenumber (cm-1) Fe3O4/K-OMS-2 K-OMS-2 NTP 0.02 0 0 1050 875 HCl CCl4 825 0.14 0.12 CHCl3 0.1 Absorbance (-) 0.008 0.004 855 845 835 Wavenumber (cm-1) Fe3O4/K-OMS-2 K-OMS-2 CeO2 NTP 0.01 0.006 865 0.08 0.06 0.04 0.002 0 3050 3000 2950 2900 2850 2800 2750 2700 Wavenumber (cm-1) Absorbance (-) 0.02 DCAC 0.06 Absorbance (-) 0.03 0.02 0 810 800 790 780 770 Wavenumber (cm-1) 760 750 Figure 75. Zoomed FT-IR outlet spectra of the chlorinated by-products in the plasma-alone and PPC system with KOMS-2 and Fe3O4/K-OMS-2, at a catalyst temperature of 150 °C. The spectra were measured at a TCE conversion between 85 – 87 %. (dry air, CTCE = 500 ppm, Q = 0.5 L·min-1, Tplasma = 295.5 K, atmospheric pressure) Plasma-catalytic TCE abatement scheme To finish the chapter on the plasma-catalytic TCE abatement, a simplified TCE degradation scheme is presented in Figure 76. When passing TCE polluted air through plasma, electronmolecule collisions convert N2 and O2 molecules to a mixture of ionized, excited, metastable and radical species that are able to decompose TCE to polychlorinated intermediates (phosgene, DCAC, TCAA) and total oxidation products (CO, CO2, HCl, Cl2). Molecular oxygen is also involved in a three body reaction leading to the formation of O3. Downstream of the plasma source, O3 comes into contact with the catalyst surface and dissociates towards molecular and radical oxygen species. These surface species promote the further oxidation of residual TCE and the chlorinated by-products towards CO, CO2, HCl and Cl2 via pathway 1. In case of 97 cryptomelane-type catalysts (K-OMS-2 and Fe3O4/K-OMS-2) an additional reaction path (pathway 2) is present, leading to the formation of CCl4 and CHCl3 through carbon-carbon cleavage of DCAC and TCAA. Figure 76. Simplified TCE degradation scheme in a plasma-catalytic process 98 10 Conclusion In this thesis, the abatement of TCE in a plasma-catalytic system was studied. Three different catalysts were studied and compared based on the removal efficiency, COx selectivity and the formation of harmful by-products. Furthermore, the influence of the following process parameters on the TCE abatement process was studied: gas flow rate, humidity and TCE inlet concentration. Focus was on operating the PPC system at low energy density in combination with a low catalyst temperature to improve the energy efficiency of the TCE abatement process. First, the abatement of TCE in a plasma-alone process was studied. The plasma was generated in a multi-pin-to-plate reactor connected with a DC power source. FT-IR and MS spectrometry revealed the presence of hazardous products phosgene, DCAC, TCAA and ozone in the plasma treated outlet gas. The ozone outlet concentration was monitored because it indicates the oxidative power of NTP. The degradation experiments were performed for two different gas flow rates: 0.5 and 2 L·min1 . An increase of the gas flow rate enhanced the removal efficiency. However, this effect disappeared when operating at an energy density lower than 175 J·L-1. For the removal of 95 % of the initial TCE in the inlet gas, an energy density of 300 J·L-1 (2 L·min-1) and 650 J·L-1 (0.5 L·min-1) was needed. In contrast, a lower gas flow rate resulted in an increase of the selectivity towards CO and CO2. However, the COx selectivity remained low. Even at 1050 J·L1 (0.5 L·min-1) the COx selectivity did not exceeded 31 %. An increase of the gas flow rate slightly inhibited the formation of HCl and phosgene, but resulted in a small increase of the DCAC production. The ozone formation was not affected by the gas flow rate. The experiments with humid TCE polluted air showed a maximal removal efficiency at a relative humidity of 15 %. This optimal humidity level is a compromise between two opposite effects of water on TCE removal. On the one hand, addition of water enhances TCE removal due to the production of strong oxidizing OH radicals. On the other hand, water has a negative effect on TCE abatement since OH radicals strongly react with other TCE oxidizing species such as ClO and oxygen radicals. In addition, water lowers the formation of active species due to its electronegative characteristics. An increase of the humidity also increased the COx selectivity. A maximal COx selectivity of 19 % was reached for a humidity of 80 % RH, when operating at 100 J·L-1. Under humid conditions, the formation of ozone was suppressed since OH radicals strongly react with oxygen radicals. Furthermore, humidity enhanced the formation of HCl, and inhibited the production of DCAC due to the strong oxidizing power of OH radicals. Humidity also affected the stability of the NTP. Addition of water led to an unstable plasma, which resulted in a decrease of the threshold current for spark formation. During the experiments, it was noted that brown/yellow spots were deposited on the spherical surface segments of the anode plate of the reactor. This deposition was formed as a result of the humidity since it was only visible during the experiments at 50 and 80 % RH. 99 The effect of the TCE inlet concentration is studied since the VOC concentration in industrial waste gases strongly varies. At an energy density of 40 J·L-1, an increase from 250 to 750 ppm TCE resulted in a decrease of the removal efficiency from 58 to 40 %. With increasing concentration, each TCE molecule shares fewer electrons and reactive plasma species, thereby reducing the probability of reaction between these species and a certain TCE molecule. The lowest TCE inlet concentration resulted in the highest COx selectivity and lowest amount of byproducts phosgene and DCAC. The formation of CO and CO2 strongly depends on the amount of oxygen radicals in NTP. Since a higher TCE inlet concentration leads to a higher amount of decomposed TCE molecules, the amount of oxygen radicals decreases with an increasing TCE concentration. This also explains the lower ozone concentration in the outlet gas with an initial TCE concentration of 750 ppm. A second series of TCE abatement experiments were performed in a post plasma-catalytic process. The performance of three different catalysts (CeO2, K-OMS-2 and Fe3O4/K-OMS-2) was investigated and compared with the plasma-alone system. The combination of NTP and a catalyst clearly enhanced the TCE abatement, and induced a synergetic effect. Ozone plays an important role in this. The catalysts studied are able to decompose ozone in active oxygen species on the catalyst surface. These active species desorb from the surface and oxidize chlorinated by-products and residual TCE, thereby enhancing the removal efficiency and COx selectivity. For the PPC system with CeO2, the highest TCE removal efficiency was achieved for a catalyst temperature of 150 °C. Operating at 40 and 80 J·L-1 resulted in a removal efficiency of 66 and 81 %, respectively. This corresponds to an enhancement of 15 % (for both energy density) compared to the plasma-alone system. An increase of the catalyst temperature from 150 to 300 °C slightly reduced the TCE removal from 81 to 77 %, at 80 J·L-1. This is possibly caused by catalyst deactivation due to irreversible adsorption of chlorinated by-products. In contrast, a catalyst temperature increase clearly enhanced the COx selectivity due to activation of the ozone decomposition reactions on the catalyst surface. An increase from 150 to 300 °C led to a shift in COx selectivity from 23 to 60 %, when operating at 40 J·L-1. The plasma-alone system (room temperature) only reached a COx selectivity of 9 %. The enhanced oxidation rate with increasing temperature resulted in an increased and decreased formation of HCl and DCAC, respectively. Remarkable was the increased phosgene production at higher catalyst temperature. A possible explanation is the increased formation of ClO radicals with temperature which further react with TCE towards phosgene. The experiments with humid air were performed at an energy density of 280 and 400 J·L-1. Due to electronegativity of water, this high energy density was needed to light up all cathode pins. An increase of the humidity from 2.8 (dry) to 80 % resulted in a decrease of the removal efficiency from 95 to 87 %, for an energy density of 280 J·L-1. This can be partly ascribed to a decrease in catalytic ozone decomposition under humid conditions since the amount of converted ozone is directly related to the concentration of newly formed active oxygen species over the catalyst surface. Another possible explanation is that the competitive adsorption of water inhibits the adsorption of TCE, thereby reducing the catalytic removal of TCE. The effect of water on the selectivity towards CO and CO2 is rather complex and strongly depends on the catalyst temperature. At low catalyst 100 temperature (< 200 °C) humidity positively influences the COx selectivity due to the strong oxidizing power of OH radicals. The effect of humidity on the formation of oxygen species on the catalyst surface is negligible since the catalyst is only little activated at low temperature. An increase of the catalyst temperature resulted in a maximal COx selectivity at a humidity of 20 % RH. This humidity level led to the highest COx selectivity due to the combination of strong oxidizing hydroxyl radicals and a high amount of ozone decomposed on the catalyst surface. A higher humidity inhibits the ozone formation resulting in a decrease of active oxygen species formed on the catalyst surface. Just as in the plasma-alone experiments, an increase of humidity resulted in an increase and decrease of phosgene and DCAC, respectively. An increase of the catalyst temperature towards 300 °C completely removed DCAC. The experiments with K-OMS-2 in dry air resulted in the highest removal efficiency. At a catalyst temperature of 150 °C, operating at 40 and 80 J·L-1 resulted in a removal efficiency of 86 and 94 %, respectively. Just as in case of CeO2, humidity negatively influenced the removal efficiency. The COx selectivity of the PPC system with K-OMS-2 reaches higher values compared to CeO2. At 150 °C and 40 J·L-1, a value of 57 % was reached. An increase of the humidity from 2.8 to 15 % resulted in a further increase to 71 %. For both dry and humid air, an increase of the energy density in time from 40 to 250 J·L-1 resulted in a decrease of the COx selectivity with 13 %. This was remarkable since the opposite effect was observed during the plasma-alone and PPC experiments with CeO2. The decreasing COx selectivity can be explained by deactivation of the catalyst. In order to further improve the total oxidation of TCE, Fe3O4/K-OMS-2 is synthesized. This cryptomelane composite led to an increase of the COx selectivity with 15 % compared to KOMS-2. However, an increase of the energy density in time again resulted in a reduction of the COx selectivity due to catalyst deactivation. In contrast to COx selectivity, Fe3O4/K-OMS-2 resulted in a lower TCE removal efficiency compared to K-OMS-2. The synergetic effect in the PPC system with Fe3O4/K-OMS-2 was negligible. Analysis of the FT-IR outlet spectra of the PPC experiments with K-OMS-2 and Fe3O4/K-OMS-2 revealed two new bands at 794 and 772 cm-1, corresponding to CCl4 and CHCl3, respectively. These compounds were not detected in the plasma-alone and PPC system with CeO2, and may be likely formed through carbon-carbon cleavage of DCAC and TCAA. This work shows the possibility to decompose TCE to a large extent towards total oxidation products (CO, CO2, HCl, Cl2) by combination of NTP at low energy density (40 – 80 J·L-1) and a catalyst at relative low temperature (150 – 200 °C). A removal efficiency and COx selectivity of 86 and 57 % was reached with K-OMS-2, when operating at 40 J·L-1 and a catalyst temperature of 150 °C. Addition of Fe3O4 nanoparticles to K-OMS-2 further increased the CO2 selectivity with 15 %, but led to a decrease of the removal efficiency with 24 %. The disadvantage of cryptomelane type catalysts is the fast deactivation rate. CeO2 is less sensitive to deactivation but resulted in a lower removal efficiency (66 %) and COx (23 %) selectivity, under the same conditions. 101 Further investigation is required to get more insight into the chemical and physical interactions between the catalyst and products formed in NTP, which allows to search more directed for the optimum catalyst composition that enables total oxidation of TCE. In order to prevent the reduction of catalyst performance due to deactivation, catalyst regeneration procedures can be developed. 102 Appendix Figure 77. FT-IR spectrum of dichloroacetylchloride (DCAC) [140] Figure 78. FT-IR spectrum of phosgene [141] 103 Figure 79. FT-IR spectrum of HCl [141] Figure 80. FT-IR spectrum of CO [141] 104 Figure 81. FT-IR spectrum of CO2 [141] Figure 82. FT-IR spectrum of ozone [141] 105 Figure 83. FT-IR spectrum of water [141] Figure 84. FT-IR spectrum of chloroform [141] 106 Figure 85. FT-IR spectrum of CCl4 [141] 107 References [1] “Council Directive 1999/13/EC of 11 March 1999 on the limitation of emissions of volatile organic compounds due to the use of organic solvents in certain activities and installations”, Official Journal L 085, 29/03/1999. pp. 0001 – 0022. [2] European Environment Agency, "Air quality in Europe", Denmark, 2013. [3] T. Stavrakou, J.-F. Muller, I. De Smedt, M. Van Roozendael, G. R. van der Werf, L. Giglio, A. Guenther, "Evaluating the performance of pyrogenic and biogenic emission inventories against one decade of space-based formaldehyde columns,” Atmospheric Chemistry and Physics, 2009. 9: pp. 1037-1038. [4] A. M. Evuti, "A synopsis on biogenic and anthropogenic volatile organic compounds emissions: hazards and control," International Journal of Engineering Sciences, 2013. 2(5): pp. 145-153. [5] L. Vancraeynest and H. Van Hooste, "verspreiding van niet-methaan vluchtige organische stoffen," MIRA, Brussels, 2013. [6] U.S. Energy Information Administration, "Emissions of greenhouse gases in the U.S.," 31 March 2011. [Online]. Available: http://www.eia.gov/environment/emissions/ghg_report/ghg_methane.cfm. [Accessed 12 October 2014]. [7] S. Han and T. Oda, "Decomposition mechanism of trichloroethylene based on byproduct distribution in the hybrid barrier discharge plasma process," Plasma Sources Science and Technology, 2007. 16(2): pp. 413-421. [8] C. Subrahmanyam, A. Renken and L. Kiwi-Minsker, "Novel catalytic non-thermal plasma reactor for the abatement of VOCs," Chemical Engineering Journal, 2007. 134(1-3): pp. 78-83. [9] M. Magureanu, N.B. Mandache, V.I. Parvulescu, C. Subrahmanyam, A. Renken, L. Kiwi-Minsker, "Improved performance of non-thermal plasma reactor during decomposition of trichloroethylene: optimization of the reactor geometry and introduction of catalytic electrode," Applied Catalysis B: Environmental, 2007. 74: pp. 270-277. [10] R. Morent, J. Dewulf, N. Steenhaut, C. Leys, H. Van Langenhove, "Hybrid plasmacatalyst system for the removal of trichloroethylene in air," Journal of Advanced Oxidation Technologies, 2006. 9(1): pp. 53-58. 108 [11] A. M. Vandenbroucke, R. Morent, N. De Geyter, M. T. Nguyen Dinh, J.-M. Giraudon, J.-F. Lamonier, C. Leys, "Plasma-catalytic decomposition of TCE," International Journal of Plasma Environmental Science & Technology, 2010. 4(2): pp. 135-138. [12] C. Most, "Locating and estimating air emissions from sources of perchloroethylene and trichloroethylene," U.S. Environmental protection agency, United States, 1989. [13] Australian Government Department of the Environment, "Trichloroethylene," 2011. [Online]. Available: http://www.npi.gov.au/resource/trichloroethylene. [Accessed 12 October 2014]. [14] National Institute for Occupational Safety and Health, "International chemical safety card trichloroethylene," cdc, October 2004. [Online]. Available: http://www.cdc.gov/niosh/ipcsneng/neng0081.html. [Accessed 12 October 2014]. [15] E. Smet and S. Deboosere, "Behandeling van vluchtige chloorverbindingen in afgassen," Kluwer, 2013. 19(1): pp. 1-3. [16] NCE-Crawford-EMCOTEK, "Crawford's regenerative thermal oxidizer systems," 2013. [Online]. Available: http://www.animalcremation.com/crawfordindustrial/voc/thermal_regenerative/regenerative_thermal_o xidizers.html. [Accessed 12 October 2014]. [17] R. Lylykangas, "Thermal or catalytic VOC oxidation?," 22 September 2010. [Online]. Available: http://formiasmartvoc.com/thermal-or-catalytic-voc-oxidation. [Accessed 12 October 2014]. [18] D. Volckaert, P. M. Heynderickx, S. Wuytens, H. Van Langenhove, “Removal of dimethylsulfide, n-hexane and toluene from waste air in a flat membrane bioreactor under continuous conditions,” Gent University, 2013. [19] H. H. Bengtson, "Carbon adsorbers," in Air Pollution Control: Carbon Adsorption for VOCs, U.S. Environmental Protection Agency, 2002. pp. 3-11. [20] I. Langmuir and L. Tonks, "Oscillations in ionized gases," Physical Review, 1929. 33: pp. 195. [21] H. Rauscher, M. Perucca and G. Buyle, "Introduction to plasma technology for surface functionalization," in Plasma Technology for Hyperfunctional Surfaces. Food, Biomedical and Textile Applications, Germany, 2010. WILEY-VCH, pp. 3-6. [22] H. O. Rucker, Introduction to plasma physics, Austria: Karl-Franzens-University Graz, 2007. organische 109 [23] A. Fridman, "Introduction to theoretical and applied plasma chemistry," in Plasma Chemistry, Unites States, 2008. Cambridge University Press, pp. 1-2. [24] J. Van Durme, "Development of heterogeneous plasma catalysis for the abatement of health damaging organic micropollutants in indoor environments," Ghent University, Bioscience engineering, 2008. pp. 18. [25] A. M. Vandenbroucke, R. Morent, N. De Geyter, C. Leys, "Non-thermal plasmas for non-catalytic and catalytic VOC abatement," Journal of Hazardous Materials, 2011. 195: pp. 30-54. [26] T. Callebaut, I. Kochetov, Y. Akishev, A. Napartovich, C. Leys, "Numerical simulation and experimental study of the corona and glow regime of a negative pinto-plate discharge in flowing ambient air," Plasma Sources Science and Technology, 2003. 13: pp. 245-250. [27] J. Chang, "Corona Discharge Processes," IEEE Transactions On Plasma Science, 1991. 19(6): pp. 1152. [28] A. Jaworek and A. Krupa, "Corona discharge from a multipoint electrode in flowing air," Journal of Electrostatics, 1996. 38: pp. 187-188. [29] J. S. Townsend, Philosophical Magazine, 1914. 28. [30] K. Satoh, T. Matsuzawaa and H. Itoh, "Decomposition of benzene in a corona discharge at atmospheric pressure," Thin Solid Films, 2008. 516(13): pp. 4423-4429. [31] X. Zhang, W. Feng, Z. Yu, S. Li, J. Zhu, K. Yan, "Comparison of styrene removal in air by positive and negative DC corona discharges,” International Journal of Environmental Science and Technology, 2013. 10: pp. 1377-1382. [32] Y. Akishev, M. Grushin, I. Kochetov, A. Napartovich, M. Pan`kin, N. Trushkin, "Transition of a multipin negative corona in atmospheric air to a glow discharge," Plasma Physics Reports, 2000. 26(2): pp. 157-163. [33] Z. Machala, E. Marode, C. Laux, C. Kruger, "DC Glow Discharges in atmospheric pressure air," Journal of Advanced Oxidation Technologies, 2004. 7(2): pp. 133-137. [34] A. Mohamed, R. Block and K. Schoenbach, "Direct current glow discharges in atmospheric air," IEEE Transactions On Plasma Science, 2002. 30(1): pp. 182-183. [35] D. M. El-zeer and A. A. Garamoon, "Atmospheric pressure glow discharge plasma in air at frequency 50 Hz," Plasma Sources Science and Technology, 2009. 18(4). 110 [36] D. Trunec, A. Brablec and F. Šťastný, "Experimental study of atmospheric pressure glow discharge," Contributions to Plasma Physics, 1998. 38(3): pp. 435-445. [37] R. Vertriest, R. Morent, J. Dewulf, C. Leys, H. Van Langenhove, "Multi-pin-to-plate atmospheric glow discharge for the removal of volatile organic compounds in waste air," Plasma Sources Science and Technology, 2003. 12: pp. 412-416. [38] Y. Akishev, M. Grushin, I. Kochetov, V. Karal´nik, A. Napartovich, "Negative corona, glow and spark discharges in ambient air and transitions between them," Plasma Sources Science and Technology, 2005. 14: pp. S18-S25. [39] Y. Akishev, O. Goossens, T. Callebaut, C. Leys, A. Napartovich, N. Trushkin, "The influence of electrode geometry and gas flow on corona-to-glow and glow-to-spark threshold currents in air," Journal of Physics: Applied Physics, 2001. 34: pp. 28752882. [40] G. Zheng, J. Hou and J. Jiang, "Degradation of flowing low-density gaseous toluene by non-equilibrium plasma," Journal of Fudan University (Natural Science), 2001. 40(4): pp. 364-367. [41] J. Jiang, J. Hou and G. Zheng, "The decomposition of benzene and xylene under normal atmospheric pressure by dielectric barrier discharge," Journal of Environmental Sciences, 2001. 21(6): pp. 531-534. [42] M. Chang and C. Lee, "Destruction of formaldehyde with dielectric barrier discharge plasmas," Environmental Science & Technology, 1995. 29(1): pp. 181-186. [43] W. Liang, W. Jiang, L. Zhang, J. Wua, J. Zhang, D. Yang, "Experimental studies of removing typical VOCs by dielectric barrier discharge reactor of different sizes," Process Safety and Environmental Protection, 2014. [44] C. Subrahmanyam, M. Magureanu, A. Renken, L. Kiwi-Minsker, "Catalytic abatement of volatile organic compounds assisted by non-thermal plasma," Applied Catalysis B: Environmental, 2006. 65: pp. 150-156. [45] U. Kogelschatz, B. Eliasson and W. Egli., "Dielectric-barrier discharges. Principle and applications," Journal de Physique, 1997. 7(4): pp. 47-66. [46] T. Oda, R. Yamashita, I. Haga, T. Takahashi, S. Masuda, "Decomposition of gaseous organic contaminants by surface discharge induced plasma chemical processing," IEEE Transactions on Industry Applications, 1996. 32(1): pp. 118-124. [47] T. Oda, T. Takahashi, H. Nakano, S. Masuda, "Decomposition of fluorocarbon gaseous contaminants by surface discharge induced plasma chemical processing," IEEE Transactions on Industry Applications, 1993. 29(4): pp. 787-792. 111 [48] S. Masuda, K. Akutsu, M. Kuroda, Y. Awatsu, Y. Shibuya, "A ceramic based ozonizer using high frequency discharge," IEEE Transactions on Industry Applications, 1988. 24(2): pp. 223-231. [49] A. A. Assadia, A. Bouzazaa, M. Lemaslea, D. Wolbert, "Removal of trimethylamine and isovaleric acid from gas streams in a continuous flow surface discharge plasma reactor (In Press, Corrected Proof)," Chemical Engineering Research and Design, 2014. [50] Y. Oishi, Y. Ehara and T. Yamamoto, "VOC removal using adsorption and surface discharge," in 11th International Conference on Electrostatic Precipitation, Hangzhou, 2008. [51] F. Holzer, F.-D. Kopinke and U. Roland, "Influence of ferroelectric materials and catalysts on the performance of non-thermal plasma (NTP) for the removal of air pollutants," Plasma Chemistry and Plasma Processing, 2005. 25(6): pp. 595-611. [52] U. Roland, F. Holzer and F.-D. Kopinke, "Improved oxidation of air pollutants in a non-thermal plasma," Catalysis Today, 2002. 73: pp. 315-323. [53] W. Liang, J. Li and Y. Jin, "Abatement of toluene from gas streams via ferroelectric packed bed dielectric barrier discharge plasma," Journal of Hazardous Materials, 2009. 170: pp. 633-638. [54] K. Takaki, S. Takahashi, S. Mukaigawa, T. Fujiwara, K. Sugawara, T. Sugawara, "Influence of pellet shape of ferro-electric packed-bed plasma reactor on ozone generation and NO removal," International Journal of Plasma Environmental Science and Technology, 2009. 3(1): pp. 28-34. [55] T. Yamamoto, K. Ramanathan, P. Lawless, D. Ensor, J. Newsome, N. Plaks, G. Ramsey, "Control of vollatile organic compounds by an ac energized ferroelectric pellet reactor and a pulsed corona reactor," IEEE Transactions on Industry Applications , 1992. 28(3): pp. 528-533. [56] A. Ogata, N. Shintani, K. Mizuno, S. Kushiyama, "Decomposition of benzene using a nonthermal plasma reactor packed with ferroelectric pellets," IEEE Transactions on Industry Applications, 1999. 35: pp. 753-759. [57] A. M. Vandenbroucke, R. Morent, N. De Geyter, C. Leys, "Decomposition of trichloroethylene with plasma-catalysis: A review," journal of advanced oxidation technologies, 2011. 14(1): pp. 1-9. 112 [58] T. Zhu, "VOCs decomposition via modified ferroelectric packed bed dielectric barrier discharge plasma," IEEE Transactions on Plasma Science, 2011. 39(8): pp. 16951700. [59] V. Parvulescu, M. Magureanu and P. Lukes, “Plasma Chemistry and Catalysis in Gases and Liquids,” John Wiley & Sons, 2013. [60] P. Lukes, M. Clupek, V. Babicky, V. Janda, P. Sunka, "Generation of ozone by pulsed corona discharge over water surface in hybrid gas–liquid electrical discharge reactor," Journal of Physics D: Applied Physics, 2005. 38(3): pp. 409-416. [61] J-S. Chang, P. Lawless and T. Yamamoto, "Corona discharge processes," IEEE Transactions on Plasma Sciences, 1991. 19(6): pp. 1152-1166. [62] I. Park and W. Koh, "Numerical Simulation of a Pulsed Corona Discharge Plasma," Journal of the Korean Physical Society, 2003. 42: pp. S920-S924. [63] A. M. Vandenbroucke, R. Aerts, W. Van Gaens, N. De Geyter, C. Leys, R. Morent, A. Bogaerts, "Modeling and Experimental Study of Trichloroethylene Abatement with a Negative Direct Current Corona Discharge," Plasma Chemistry and Plasma Processing, 2015. 35: pp. 217-230. [64] W. Siemens, "Ueber die elektrostatische Induction und die Verzögerung des Stroms in Flaschendrähten," poggendorff annalen der physik und chemie, 1857. 102: pp. 66122. [65] J. Chen and J. Davidson, "Ozone Production in the Positive DC Corona Discharge: Model and Comparison to Experiments," Plasma Chemistry and Plasma Processing, 2002. 22(4): pp. 495-496. [66] D. Braun, U. kuchler and G. Pietsch, "Microdischarges in Air-Fed Ozonizers," Journal of Physics D: Applied Physics, 1991. 24: pp. 564-572. [67] B. Eliasson, U. Kogelschatz and P. Baessler, "Dissociation of O2 in N2/O2 mixtures," Journal of Physics B: Atomic and Molecular Physics, 1984. 17(22): pp. L797-L801. [68] M. Benyamina, K. Khodja, F. Ghaleb, A. Belasri, "Influence of the Gas Temperature in Ozone Production of Mixture N2-O2," Journal of Chemistry and Chemical Engineering, 2012. 6: pp. 391-392. [69] R. Morent and C. Leys, "Ozone Generation in Air by a DC-Excited Multi-Pin-toPlane Plasma Source," Ozone: Science and Engineering, 2005. 27: pp. 239-245. 113 [70] H. Einagaa and A. Ogata, "Benzene oxidation with ozone over supported manganese oxide catalysts: Effect of catalyst support and reaction conditions," Journal of Hazardous Materials, 2009. 164: pp. 1236-1241. [71] M. Nguyen Dinh, J. Giraudon, J. Lamonier, A. Vandenbroucke, N. De Geyter, C. Leys, R. Morent, "Plasma-catalysis of low TCE concentration in air using LaMnO3+δ as catalyst," Applied Catalysis B: Environmental, 2014. 147: pp. 904-911. [72] H.H. Kim, A. Ogata, S. Futamura, "Complete Oxidation of Volatile Organic Compounds (VOCs) Using Plasma-Driven Catalysis and Oxygen Plasma," International Journal of Plasma Environmental Science & Technology, 2007. 1(1): pp. 46-51. [73] H. An, T. Huu, T. Van, J. Cormier, A. Khacef, "Application of atmospheric non thermal plasma-catalysis hybrid system for air pollution control: Toluene removal," Catalysis Today, 2011. 176(1): pp. 474-477. [74] H. Sekiguchi, "Catalysis assisted plasma decomposition of benzene using dielectric barrier discharge," The Canadian Journal of Chemical Engineering, 2009. 79(4): pp. 512-519. [75] R. Morent, J. Dewulf, N. Steenhaut, C. Leys, H. Van Langenhove, "Hybrid plasmacatalyst system for the removal of trichloroethylene in air," Journal of Advanced Oxidation Technologies, 2006. 9(1): pp. 1-6. [76] U. Roland, F. Holzer and F.-D. Kopinke, "Combination of non-thermal plasma and heterogeneous catalysis for oxidation of volatile organic compounds: Part 2. Ozone decomposition and deactivation of γ-Al2O3," Applied Catalysis B: Environmental, 2005. 58(3-4): pp. 217-226. [77] M. Sugasawa and S. Futamura, "Synergistic Effect of Nonthermal Plasma and Catalysts on the Decomposition of VOCs," Industry Applications Conference, 2007. pp. 1485-1488. [78] H. H. Kim, A. Ogata and S. Futamura, "Oxygen partial pressure-dependent behavior of various catalysts for the total oxidation of VOCs using cycled system of adsorption and oxygen plasma," Applied Catalysis B: Environmental, 2008. 79: pp. 356-367. [79] K. Hensel, S. Katsura and A. Mizuno, "DC microdischarges inside porous ceramics," IEEE Transactions on Plasma Science, 2005. 33(2): pp. 574-575. [80] S. Chavadej, W. Kiatubolpaiboon, P. Rangsunvigit, T. Sreethawong, "A combined multistage corona discharge and catalytic system for gaseous benzene removal," Journal of Molecular Catalysis A: Chemical, 2007. 263(1-2) pp. 128-136. 114 [81] J. Chae, V. Demidiouk, M. Yeulash, I. Choi, T. Jung, "Experimental study for indoor air control by plasma-catalyst hybrid system," IEEE Transactions on Plasma Science, 2004. 32: pp. 493-497. [82] Y. Guo, D. Yea, K. Chenb, J. Hea, W. Chena, "Toluene decomposition using a wireplate dielectric barrier discharge reactor with manganese oxide catalyst in situ," Journal of Molecular Catalysis A: Chemical, 2006. 245(1-2): pp. 93-100. [83] A. Pribytkov, G. Baeva, N. Telegina, A. Tarasov, A. Stakheev, A. Tel’nov, V. Golubeva, "Effect of electron irradiation on the catalytic properties of supported Pd catalysts," Kinetics and Catalysis, 2006. 47(5): pp. 765-769. [84] H. H. Kim, A. Ogata and S. Futamura, "comparative assessment of different nonthermal plasma reactors on energy efficiency and aerosol formation from the decomposition of gas-phase benzene," IEEE transactions on industry applications, 2005. 41(1): pp. 206-214. [85] Y. Guo, D. Ye, Y. Tian, K. Chen, "Humidity Effect on Toluene Decomposition in a Wire-plate Dielectric Barrier Discharge Reactor," Plasma Chemistry and Plasma Processing, 2006. 26(3): pp. 237-249. [86] M. Peluso, L. Gambaro, E. Pronsato, D. Gazzoli, H. Thomas, J. Sambeth, "Synthesis and catalytic activity of manganese dioxide (type OMS-2) for the abatement of oxygenated VOCs," Catalysis Today, 2008. 133-135: pp. 487-492. [87] P. Ruetschi, "Cation‐Vacancy Model for MnO2," Journal of the Electrochemical Society, 1984. 131(12): pp. 2737-2744. [88] H. Einaga and S. Futamura, "Catalytic oxidation of benzene with ozone over Mn ionexchanged zeolites," Catalysis Communications, 2007. 8(3): pp. 557-560. [89] S. Futamura and A. Gurusamy, "Synergy of nonthermal plasma and catalysts in the decomposition of fluorinated hydrocarbons," Journal of Electrostatics, 2005. 63: pp. 949-954. [90] J. Jarrige and P. Vervisch, "Plasma-enhanced catalysis of propane and isopropyl alcohol at ambient temperature on a MnO2-based catalyst," Applied Catalysis B: Environmental, 2009. 90: pp. 74-82. [91] Y. Li, Z. Fan, J. Shi, Z. Liu, W. Shangguan, "Post plasma-catalysis for VOCs degradation over different phase structure MnO2 catalysts," Chemical Engineering Journal, 2014. 241: pp. 251-258. 115 [92] Y.-H. Song, S.-J. Kim, K.-I. Choi, T. Yamamoto, "Effects of adsorption and temperature on a nonthermal plasma process for removing VOCs," Journal of Electrostatics, 2002. 55(2): pp. 189-201. [93] A. Ogata, K. Yamanouchi, K. Mizuno, S. Kushiyama, T. Yamamoto, "Oxidation of Dilute Benzene in an Alumina Hybrid Plasma Reactor at Atmospheric Pressure," Plasma Chemistry and Plasma Processing, 1999. 19(3). [94] D.-W. Park, S.-H. Yoon, G.-J. Kim, H. Sekiguchi, "The Effect of Catalyst on the Decomposition of Dilute Benzene Using Dielectric Barrier Discharge," Journal of Industrial and Engineering Chemistry, 2002. 8(4). [95] A. Ogata, H.H. Kim, S.M. Oh, H. Einaga and S. Futamura, "Relationship Between Ozone Formation and Toluene Decomposition Efficiency in a Zeolite-hybrid Plasma Reactor," in International Society for Electrostatic Precipication, Australia, 2006. [96] H.H. Kim, J.H. Kim and A. Ogata, "Adsorption and Oxygen Plasma-Driven Catalysis for Total Oxidation of VOCs," International Journal of Plasma Environmental Science and Technology, 2008. 2(2): pp. 106-112. [97] L. Intriago, E. Dı´az, S. Ordo´n˜ez, A. Vega, "Combustion of trichloroethylene and dichloromethane over protonic zeolites: Influence of adsorption properties on the catalytic performance," Microporous and Mesoporous Materials, 2006. 91: pp. 161169. [98] U.S. Secretary of Commerce on behalf of the United States of America, "NIST: National Institute of Standards and Technology," DOW CHEMICAL COMPANY, 2011. [Online]. Available: http://webbook.nist.gov/cgi/cbook.cgi?ID=C50000&Type=IR-SPEC&Index=1. [Accessed 23 November 2014]. [99] M. Loudon, "Infrared Spectroscopy: Theory," in Handbook for Organic Chemistry Lab, Colorado, 2002. pp. 155-164. [100] T. Nicolet, "FT-IR vs. Dispersive Infrared," 2012. [Online]. Available: http://www.thermo.com.cn/resources/200802/productpdf_21615.pdf. [Accessed 24 November 2014]. [101] "Infra-red absorption spectroscopy," Sheffield Hallam University, 2008. [Online]. Available: http://teaching.shu.ac.uk/hwb/chemistry/tutorials/molspec/irspec3.htm. [Accessed 24 November 2014]. [102] U.S. Secretary of Commerce on behalf of the United States of America, "NIST, National Institute of Standards and Technology," 2014. [Online]. Available: 116 http://webbook.nist.gov/cgi/cbook.cgi?ID=C79016&Mask=200. November 2014]. [Accessed 24 [103] P. Biosoft, "Mass Spectrometry," 2011. [Online]. Available: http://www.premierbiosoft.com/tech_notes/mass-spectrometry.html. [Accessed 24 November 2014]. [104] Scripps Center for Metabolomics and Mass Spectrometry, "What is Mass Spectrometry?," 2010. [Online]. Available: http://masspec.scripps.edu/mshistory/whatisms_details.php#massanalyzers. [Accessed 24 November 2014]. [105] C. Ren, T. Ma, D. Wang, J. Zhang, Y. Wang, “A study of cross-gas-flow to stabilize an atmospheric pressure glow plasma in a multi-pin-to-multi-cupped-plane negative corona discharge,” Journa of Electrostatics, 2005. 64: pp. 23-28. [106] A. Vandenbroucke, “Studie van plasmakatalytische afbraakprocessen van vluchtige organische stoffen,” Masterthesis at University Ghent, Department Applied Physics, 2009. p. 125. [107] X. Zhu, X. Gao, C. Zheng, Z. Wang, M. Ni, X. Tu, “Plasma-catalytic removal of a low concentration of acetone in humid conditions,” The Royal Society of Chemistry, 2014. 4: pp. 37796-37805. [108] P. Wang and J. Chen, “Effect of relative humidity on electron distribution and ozone production by DC coronas in air,” Transactions on Plasma Science, 2005. 33(2): pp. 808-812. [109] H. Ge, L. Zhang, L. Yan, D. Mi, Y. Zhu, “Parameter optimization of excited OH radical in multi-needle to plate negative DC corona discharge,” Journal of Electrostatics, 2011. 69: pp. 529-532. [110] D. Evans, L. A. Rosocha, G. K. Anderson, J. J Coogan, “Plasma remediation of trichloroethylene in silent discharge plasmas,” Journal of Applied Physics , 1993. 74(9): pp. 5378-5386. [111] G. Socrates, “Infrared and Raman characteristic group frequencies: Tables and charts,” West Sussex, England: Wiley, 2004. [112] TCI America, “Material safety data sheet DCAC,” [Online]. Available: https://www.spectrumchemical.com/MSDS/TCI-D0313.pdf. [Accessed 15 March 2015]. [113] A. Vandenbroucke, M. T. N. Dinh, J-M. Giraudon, R. Morent, N. De Geyter, J-F. Lamonier, C. Leys, “Qualitative by-product identification of plasma-assisted TCE 117 abatement by mass spectrometry and fourier-transform infrared spectroscopy,” Plasma Chem Plasma Process, 2011. 31: pp. 707-718. [114] L. Prager, H. Langguth, S. Rummel, R. Mehnert, “Electron beam degradation of chlorinated hydrocarbons in air,” Radiation Physics and Chemistry, 1995. 46(4-6): pp. 1137-1142. [115] S. A. Vitale, K. Hadidi, D. R. Cohn, P. Falkos, “The effect of a carbon-carbon double bond on electron beam-generated plasma decomposition of trichloroethylene and 1,1,1-trichloroethane,” Plasma Chemistry and Plasma Processing, 1997. 17(1): pp. 59-78. [116] M. J. Kirkpatrick, W. C. Finney and B. R. Locke, “Chlorinated organic compound removal by gas phase pulsed streamer corona electrical discharge with reticulated vitreous carbon electrodes,” Plasmas and Polymers, 2003. 8(3): pp. 165-177. [117] Sigma-Aldrich, “chemblink,” 2009. [Online]. Available: http://www.chemblink.com/MSDS/MSDSFiles/75-87-6_Sigma-Aldrich.pdf. [Accessed 28 March 2015]. [118] J. S. Gift, R. McGaughy, D. V. Singh, B. Sonawane, “Health assessment of phosgene: approaches for derivation of reference concentration,” Regul Toxicol Pharmacol, 2008. 51(1): pp. 98-107. [119] Y. Nakagawa, Y. Tomimura, R. Ono, T. Oda, “Dilute trichloroethylene decomposition by non-thermal plasma-catalyst and humidity effect, and OH radical behavior,” in Joint Electrostatics Conference 1, 2012. [120] A. S. Chiper, N. Blin-Simiand, M. Heninger, H. Mestdagh, P. Boissel, F. Jorand, J. Lemaire, J. Leprovost, S. Pasquiers, G. Popa, C. Postel, “Detailed characterization of 2-heptanone conversion by dielectric barrier discharge in N2 and N2/O2 mixtures,” Journal of Physical Chemistry, 2010. A114: pp. 397-407. [121] N. Blin-Simiand, F. Jorand, L. Magne, S. Pasquiers, C. Postel, J.R. Vacher, “Plasma reactivity and plasma-surface interactions during treatment of toluene by a dielectric barrier discharge,” Plasma Chemistry and Plasma Processing, 2008. 28: pp. 429-466. [122] S. Delagrange, L. Pinard and J. M. Tatibouet, “Combination of a non-thermal plasma and a catalyst for toluene removal from air: manganese based oxide catalysts,” Applied Catalysis B: Environmental, 2006. 68: pp. 92-98. [123] Sugasawa and S. Futamura, “Additive effect on energy efficiency and byproduct distribution in VOC decomposition with nonthermal plasma,” IEEE Transactions on Industry Applications, 2008. 44: pp. 40-45. 118 [124] K. Abedi, F. Ghorbani-shahna, B. Jaleh, A. Bahrami, R. Yarahmadi, “Enhanced performance of non-thermal plasma coupled with TiO2/GAC for decomposition of chlorinated organic compounds: influence of a hydrogen-rich substance,” Journal of Environmental Health Science & Engineering, 2014. 12(119): pp. 1-13. [125] M. Magureanu, N. B. Mandache and V. I. Parvulescu, “Chlorinated organic compounds decomposition in a dielectric barrier discharge,” Plasma Chem Plasma Process, 2007. 27: pp. 679-690. [126] B. Harrison, A. F. Diwell and C. Hallett, “Promoting platinum metals by ceria,” Platinum Metals Review, 1988. 32(2): pp. 73-83. [127] A. Naydenov, R. Stoyanova and D. Mehandjiev, “Ozone decomposition and CO oxidation on CeO2,” Journal of Molecular Catalysis A: Chemical, 1995. 98: pp. 9-14. [128] B. Dhandapani and S.T. Oyama, “Gas phase ozone decomposition catalysts,” Applied Catalysis B: Environmental, 1997. 11: pp. 129-166. [129] A. M. Vandenbroucke, M. Mora, C. Jiménez-Sanchidrián, F. J. Romero-Salguero, N. De Geyter, C. Leys, R. Morent, “TCE abatement with a plasma-catalytic combined system using MnO2 as catalyst,” Applied Catalysis B: Environmental, 2014. 156-157: pp. 94-100. [130] M. T. Nguyen Dinh, J.-M. Giraudon, A. M. Vandenbroucke, R. Morent, N. De Geyter, J. -F. Lamonier, “Post plasma-catalysis for total oxidation of trichloroethylene over Ce-Mn based oxides synthesized by a modified "redox-precipitation route",” Applied Catalysis B: Environmental, 2015. 172-173: pp. 65-72. [131] X. Fan, T. Zhu, Y. Wan and X. Yan, “Effects of humidity on the plasma-catalytic removal of low-concentration BTX in air,” Journal of Hazardous Materials, 2009. 180: pp. 616-621. [132] T. Oda, Y. Nakagawa, R. Ono, H. Fujisawa, “Non-thermal plasma decomposition of dilute trichloroethylene in air - catalyst effect,” in International Society for Electrostatic Precipitation, 2008. China. [133] R. Buszek, J. Barker and J. Francisco, “Water effect on the OH + HCl reaction, ”Journal of Physical Chemistry, 2012. 116(19): pp. 4712-4719. [134] F. Schurz, J. M. Bauchert, T. Merker, T. Schleid, H. Hasse, R. Gläser, “Octahedral molecular sieves of the type K-OMS-2 with different particle sizes and morphologies: Impact on the catalytic properties in the aerobic partial oxidation of benzyl alcohol,” Applied Catalysis A: General, 2009. 355(1-2): pp. 42-49. 119 [135] D. Frías, S. Nousir, L. Barrio, M. Montes, T. López, M.A. Centeno, J.A. Odriozola, “Synthesis and characterization of cryptomelane- and birnessite-type oxides: Precursor effect,” Materials Characterization, 2007. 58: pp. 776-781. [136] A. R. Gandhe, J. S. Rebello, J. L. Figueiredo, J.B. Fernandes, “Manganese oxide OMS-2 as an effective catalyst for total oxidation of ethyl acetate,” Applied Catalysis B: Environmental, 2007. 72: pp. 129-135. [137] J. E. Post, R. B. Von Dreele and P. R. Buseck, “Symmetry and cation displacements in hollandites: structure refinements of hollandite, cryptomelane and priderite,” Acta Crystallographica Section B, 1982. 38: pp. 1056-1065. [138] A. Lu, X. Gao, C. Wang, Y. Gao, D. Zheng, T. Chen, D. Zhao, S. Qin, “Natural cryptomelane and its potential application in the adsorption of heavy metal cadmium,” Journal of Mineralogical and Petrological Sciences, 2007. 102: pp. 217-225. [139] S. Zhang, X. Zhao, H. Niu, Y. Shi, Y. Cai, G. Jiang, “Superparamagnetic Fe3O4 nanoparticles as catalysts for the catalytic oxidation of phenolic and aniline compounds,” Journal of Hazardous Materials, 2009. 167: pp. 112-119. [140] AcrosOrganics, „Chemexper,” [Online]. Available: https://www.chemexper.com/searchResult.shtml?format=ccd2013%2Cccd&target=s tructure&options=brandqtyoffercrm&i=e7fad7&country=BE&searchValue=Dichlor oacetyl+chloride&searchTemplate=rn.value%3D%22%3F%22+elsor+iupac.value% 3D%22%3F%22+elsor+mol.value%3D%22%3F%. [Accessed 15 March 2015]. [141] “NIST: National Institute of Standards and Technology,” [Online]. Available: http://webbook.nist.gov/Chemistry/. [Accessed 15 March 2015]. 120