* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 7154 VFD
Ground (electricity) wikipedia , lookup
Ringing artifacts wikipedia , lookup
Brushless DC electric motor wikipedia , lookup
Spectral density wikipedia , lookup
Stage monitor system wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Spectrum analyzer wikipedia , lookup
Rotary encoder wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Three-phase electric power wikipedia , lookup
Voltage optimisation wikipedia , lookup
Transmission line loudspeaker wikipedia , lookup
Mains electricity wikipedia , lookup
Chirp spectrum wikipedia , lookup
Wien bridge oscillator wikipedia , lookup
Induction motor wikipedia , lookup
Mathematics of radio engineering wikipedia , lookup
Rectiverter wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Alternating current wikipedia , lookup
Power electronics wikipedia , lookup
Power inverter wikipedia , lookup
Stepper motor wikipedia , lookup
7154 VFD Presentation #2 May 2002 Paul Weingartner Inverter types VVI CSI PWM – current technology Acceleration Linear ramp S-curve Deacceleration If the drive is ramped down too quickly, the motor becomes a generator and will drive the DC bus voltage up This can cause the drive to fault due to a bus overvoltage Skip frequencies Every mechanical system has a resonant frequency(s). Drive operation at that resonant frequency can cause problems and potentially damage the system VFDs can be programmed to skip over these frequencies (i.e. not dwell on them) Flux vector drives Use encoder feedback to obtain exact information on what the motor is doing Adding an encoder and feedback board to a drive will typically add $1000 in cost Vector drive benefits Speed regulation to 0.01% High torque at zero speed Torque linearity Fast response to load changes Sensorless vector drives Do not have the encoder for external feedback Feedback is derived from the motor terminals Better control than a standard VFD Needs to go thru an auto-tune procedure Needs to be given motor characteristics in order to achieve the superior control Installation issues of VFDs Harmonics SWR / Cable length issues Bearing currents Carrier frequency Radio Frequency Interference (RFI) Harmonics In the United States, 60 Hertz power is the standard In Europe, 50 Hz power is used Terminology 60 Hz is the fundamental frequency Also known as the 1st harmonic The frequency of any harmonic can be calculated by the number of the harmonic multiplied by the fundamental frequency Example: The 5th harmonic would be 5 x 60 Hz = 300 Hz Which harmonics Only even number harmonics are present in VFD systems Most important harmonics 3rd 5th 7th Harmonic properties 3rd - also known as a “triplen” – Zero sequence harmonic 5th - Negative sequence harmonic 3rd Harmonic Causes neutral currents to flow NEC specifies that the neutral should be either one wire gauge larger than the gauge of the phase line or two lines should be pulled for the neutral Can cause overheating in transformers and premature failure 5th Harmonic Counter-rotating (i.e. BAD!) Harmonic distortion Measure of the sum of all of the harmonic components compared to the fundamental 60 Hz current IEEE-519 Total Harmonic Distortion (THD) Total Demand Distortion (TDD) Typically, a THD of less than 5% is considered good Mitigating harmonic problems Installing line reactors and/or filters Reactor – is another term for inductor Filter – implies RC, RL or LC components Standing Wave Ratio (SWR) Transmission line effects due to high frequency pulses Maximum power transfer theorem Creates high voltages at the motor terminals What can be done Minimize the cabling length Use inverter rated motors Don’t use a high carrier frequency Use reactors Bearing currents Using VFDs to drive motors create common mode voltages that often will reach ground through the motor shaft This causes the grease to break down Worse it can cause arc pitting of the bearings and introduce metal fragments Mitigating bearing current problems Lower the carrier frequency Use insultated bearings Ground the shaft with a slip ring RFI Anytime there is distortion in a waveform, harmonics are present. Since harmonics are multiples of the fundamental frequency and these harmonics exist in meaningful amplitudes at over 100x the fundamental frequency, RF energy is released This RF energy can cause problems for sensitive equipment and sensors Mitigating RFI problems Use shielded cable Don’t run signal wires in the same conduit as power wires Use proper grounding methods Avoid ground loops Ventilation Ventilation for the enclosure for a VFD (and any other equipment) should be considered due to the heat generated Cooling fans – also need to be checked for proper air flow and if filters are present, need to be cleaned periodically