MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI – 621213 QUESTION BANK DEPARTMENT: ECE SEMESTER: IV Subject code / Name: EC2351/ Measurement and Instrumentation UNIT-II BASIC ELECTRONIC MEASUREMENTS Part A (2 Marks) 1. Draw the internal structure of CRT and list its functions. (APRIL/MAY 2011) The instrument employs a cathode ray tube (CRT), which is the heart of the oscilloscope. It generates the electron beam, accelerates the beam to a high velocity, deflects the beam to create the image, and contains a phosphor screen where the electron beam eventually becomes visible. For accomplishing these tasks various electrical signals and voltages are required, which are provided by the power supply circuit of the oscilloscope. Low voltage supply is required for the heater of the electron gun for generation of electron beam and high voltage, of the order of few thousand volts, is required for cathode ray tube to accelerate the beam. Normal voltage supply, say a few hundred volts, is required for other control circuits of the oscilloscope. EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 1 Horizontal and vertical deflection plates are fitted between electron gun and screen to deflect the beam according to input signal. Electron beam strikes the screen and creates a visible spot. This spot is deflected on the screen in horizontal direction (X-axis) with constant time dependent rate. This is accomplished by a time base circuit provided in the oscilloscope. 2. What are the two significant problems with diodes when used for RF rectification? APRIL/MAY 2011 3. List the parameter that can measured using CRO (Nov/Dec2011) time-varying signals - by showing details of the waveshape aspects of time-varying signals Frequency of a signal Peak value of a signal 4. What is the distributed capacitance (Nov/Dec2012) Distributed capacitance of the coil is measured by changing the capacitance of resonant frequencies. The value of tuning capacitance C1 and C2 and their resonant frequncies F1 and 2F2 7. Give the principle of operation and need for Q-meter.(May 2008) Terminals are provided to connect the inductance (Lx) to be measured and this is resonated by a variable tuning capacitor (C). Terminals are also provided to add capacitance (Cx), if required. The tuned circuit is excited from a tunable signal source which develops voltage across a resistor in series with the tuned circuit. The resistor must have a resistance small compared to the loss resistance of the components to be EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 2 measured so that its value can be ignored. A resistance of a mere fraction of an ohm is necessary. Metering is provided to measure the AC injection voltage across the series resistor and the AC output voltage across the terminals of the tuning capacitor. The output measurement must be a high input impedance circuit to prevent loading of the tuned circuit by the metering circuit. Q is measured by adjusting the source frequency and/or the tuning capacitor for a peak in output voltage corresponding to resonance. Q factor is calculated as the ratio of output voltage measured across the tuned circuit to that injected into it. In practice, the signal source level is generally set for a calibrate point on the meter which measures injected voltage and Q is directly read from calibration on the meter which measures output voltage 8. The current in a circuit is got by using a resistance R of 3Ω.The vertical trace of the CRO screen is 10cm and the Y amplifier setting is 6volts/cm.Find the rms value of current taking the waveform as sine wave.(May 2008). 9. List a few application of CRO. (May 2009/Nov 2009) Using a single channel oscilloscope it is capable of making measurements of voltage, current, time, frequency and rise/fall time. 10. State the advantage of electronic instruments. (Nov 2009) Low power consumption Non-contact measurements are possible Light, compact are more reliable instrumentation Remote indication and recording Greater flexibility Lighter in construction 11. List the source of error that affect measurement accuracy of Q-meter.(May 2010) Error due to distributed capacitance Error due to Residual inductance Error due to Shunt resistor Error due to Q-voltmeter 12. What is Aquadag? What is purpose of Aquadag? (May 2010) Aquadag is a graphite based coating commonly found in cathode ray tubes The coating can be on the inside of the tube, where it helps to maintain a constant electrical field near the screen. Tubes intended for television use normally have an aluminised interior which acts as a reflector on the back of the screen, and forms one plate of a capacitor. Aquadag is also painted on part of the outside of many tubes. The glass, tube, internal aluminium coating and the outer Aquadag then form a capacitor used to filter the high voltage EHT supply. 13. What is meant by deflection sensitivity of a CRT? EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 3 The deflection sensitivity of the CRT is usually stated as the DC voltage required for each cm of deflection of the spot on the screen 14. Name the components of a CRO. CRO consists of a cathode ray tube (CRT) along with electron gun assembly, deflection plate assembly, fluorescent screen, glass envelope and base. 15. What is CRO? What are the sections of a CRO? Cathode Ray Oscilloscope (CRO) is a very careful and versatile laboratory instrument used for display measurement and analysis of waveforms and other phenomena in electrical and electronic circuits. CRO is in fact a very fast X-Y plotter displaying an input signal versus another signal or time. 16. List the different measuring methods in Q- meter. There are three methods of connecting unknown components to the test terminals of a Q- meter: direct, series and parallel. The type of component and its size determine the method of connection. 17. What is the source of error in a Q-meter? Distributed capacitance or self capacitance of the coil. Residual inductance of the instrument. conductance of voltmeter. shunt resistor of Q-meter. 18. Give brief account on working principle of CRO. The oscilloscope depends on the movement of an electron beam, which is then made visible by allowing the beam to impinge on a phosphor surface, which produces a visible spot. If the electron beam is deflected in either of the two orthogonal axes X and Y the luminous spot can be used to create two dimensional displays. 19. What is known as fluorescence?(May 2003/ECE) A phosphor converts the electrical energy to light energy. When an electron beam strikes the phosphor crystal, their energy level is increased. This causes the phosphor crystal are excited and they emit light. This phenomenon is called as fluorescence. 20. What is sampling oscilloscope? (Nov’ 2003 ECE). A Sampling Oscilloscope is used to examine very fast signals. Samples are taken at different portions of the waveform, over successive cycles, and then the total picture is stretched, amplified by relatively low bandwidth amplifiers, and displayed as continuous wave on the screen. What deflection system is required for dual-beam oscilloscope? (Nov’ 2004 ECE). It uses CRT with two separate electron guns generating two separate beams. Each beam has its own vertical deflection plates. But the two beams are deflected horizontally by the common set of horizontal plates. 21. 22. What is the working principle of sampling oscilloscope? (Nov’ 2004 ECE). EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 4 A voltage comparator compares the ramp voltage with the voltage generated by the staircase generator, when the voltage are equal it produces a pulse to the sampling gate. Thus, each time a pulse is generated, the sampling of the input signal is done. List the main parts of a Cathode ray tube. (May’ 2004 ECE). a. Electron gun assembly b. Deflection plate assembly c. Fluorescent screen d. Glass envelope e. Base 24. What is the difference between digital and analog oscilloscopes? (Nov’ 2005 ECE) (Nov/Dec2012) An analog oscilloscope collects data after it has been triggered. A digital storage oscilloscope is always collecting data, and the trigger tells if when to stop. The advantage of the analog storage oscilloscope is that it has a higher bandwidth and writing speed than a digital oscilloscope, being capable of operating speed of about 15GHz. 23. Justify – ‘A CRO can be regarded as a X-Y recorder’(Nov’ 2006 ECE) A CRO can be regarded as a X-Y recorder. The X-Y mode means, that the oscilloscope operates with channel A as the vertical signal and channel B as the horizontal signal. The accurate measurements can be done in this mode. 25. What is a vector voltmeter?(May 2004/May 2003/Nov’2006 ECE) In vector voltmeter very high frequency RF signal is converted into an equivalent IF signal .Then the amplitude and phase is measured simultaneously. The vector voltmeter is used for the following measurements: 26. 27. i. Gain of amplifier and phase shift, ii. ‘S’ parameter of transistor, iii. Insertion loss. iv. Transfer characteristics of a filter. v. Two port network parameters. vi. Amplitude modulation index. Give the characteristics of probes used in CRO. (May’ 2006 ECE) Probes are used with the oscilloscope to connect the test circuit to the oscilloscope. i. The probe should not affect the circuit under test in ideal cases. To achieve this situation a probe should have high input impedance. High input impedance means high input resistance and low input capacitance at the probe tip. ii. Any signal going to the oscilloscope, will pass through the probe first, so bandwidth of the probe combines with the bandwidth of CRO. The probe bandwidth must be higher than the oscilloscope bandwidth. iii. The probe tip is the signal sensing circuitry. It must be active or passive. If it is passive, it consists of resistor and capacitors. If active it consists of FET. 28. What is the advantage of “pretrigger view” mode of operation in digital storage oscilloscope? (May’ 2006 ECE) EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 5 The pretriggering allows the input signal preceding the trigger points to be recorded. So can be set to record continuously, until the trigger signal is received, then recording is stopped. Pretrigger can be 25%, 50%, 75% for single shot, roll normal modes, 29. How is the electron beam focused to a fine spot on the face of CRT? (May 2007) A focusing anode is mounted just ahead of the reaccelerating anode which gives the electron beam its last addition of energy before its journey to the phosphor screen. These electrons will diverge owing to variations in energy and would produce a broad ill-defined spot on the face of the CRT. 30. List the disadvantages of storage cathode ray tube. (May 2007) The digital storage oscilloscope will continuously record a selected waveform, and when the trigger waveform appears signifying a failure, the storage will stop. The consecutive type of storage oscilloscope will provide this feature. 31. Mention some of the requirements of signal generator. (May 2007-R01) The requirements for signal generator are as follows: i) ii) The frequency of the signal should be well known and stable. The amplitude should be controllable from very small to relatively large values. iii) The signal should be free of distortion. 32. Draw the block diagram of an electronic multimeter.Briefly explain the function of each block. (Nov 2007) 33. What is a vector impedance meter? State its application.(Nov 2007) The vector Impedance meter makes simultaneous measurements of impedance and phase angle over a frequency range of 400KHz to 110MHz.The unknown component is simply connected across the input terminal of the instruments, the desired frequency is selected by turning the front panel control and the two front panel lead outs indicate the magnitudes of impedance and the phase angle. 34. Give the principle of operation and need for Q-meter.(May 2008) Q meter is an instrument designed to measure some of the electrical properties of coils and capacitors. The operation is based on the characteristics of series resonant circuit. The voltage across the coil or the capacitor is equal to the applied voltage times the Q of the circuit. 35. List a few application of CRO. (May 2009/Nov 2009) 1. Measurement of voltage and current. EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 6 2. Measurement of Phase. 3. Measurement of frequency. 4. Comparison of two frequencies. 5. used for display, measurement, waveform analysis and other phenomenon in electrical and electronics circuits. 36. List the source of error that affect measurement accuracy of Q-meter.(May 2010) Factors affecting measurement accuracy are Distributed capacitance or self capacitance of the coil. Residual inductance of the instrument. Conductance of voltmeter. Shunt resistor of Q-meter. 37. What is Aquadag? What is purpose of Aquadag? (May 2010) Coating of a conducting material known as aquadag is provided over the interior surface of CRT in order to accelerate the electron beam after passing between the deflection plates and to collect the electron produced by the secondary emission when electron beam strikes the screen. 25. Mention any two types of electronic voltmeter. 1. Direct coupled electronic DC voltmeter. 2. Chopper stabilized electronic DC voltmeter. 26. What is a multimeter? It is an instrument used for measuring AC and DC voltage, AC and DC current and resistance. 27. What for a Q-meter is used? A Q-meter is used for finding the effective inductance of a coil at radio frequencies. 28. What are the different methods available for measuring RF power? i) Voltage and current method ii) photometric comparison method iii) Bolometer iv) Calorimetric measurement v) Directional wattmeter 29. What is a RF probe? It is a rectifier circuit used with a high impedance voltmeter to measure RF voltages. 30. What are the difference between AC and DC electronic voltmeter? EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 7 Electronic AC voltmeters differ from their DC counterpart only in that Ac voltage must be converted to DC before being applied to the meter movement. a waveform instead of the average value. voltmeter has high sensitivity than AC voltmeter. 31. What is Q-factor? It is the ratio of resistance and a standard capacitance. 32. What are the advantages of electronic voltmeter? Negligible loading effect. High accuracy Cheap and rugged very low voltages 33. Why is a delay line used in the vertical section of the oscilloscope? (Nov/Dec 2011) Delay line is used in the vertical section of the oscilloscope to produce a time delay of signal. 34. What is true RMS voltmeter? True RMS voltmeter is an instrument which produces a meter indication by sensing waveform heating power, which is proportional to the square of the RMS value of the voltage. It is used for measuring voltages of complex waveforms. 35. What is a CRT? It is an electron beam tube in which electrons emitted by a hot cathode are formed by an electron gun into a narrow beam that is focused onto a phosphor coated screen. 36. What is a CRO? It is a test instrument using a cathode ray tube to make visible on a phosphor coatedscreen instantaneous values and waveforms as functions of either time or some other quantity. 37. Define vertical amplifier. It is an amplifier in an oscilloscope for signals intended for vertical deflection on the screen. 38. Define horizontal amplifier. It is an amplifier in an oscilloscope for signals intended for horizontal deflection on the screen. 39. Mention any two applications of digital storage oscilloscope. EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 8 i) To analyse the waveforms by storing them in memory. ii) To compare the two waveforms. 40. List the special types of CRO. 41.What is meant by phosphorescence? The property of a phosphor material continuing to emit light after its excitation source has been removed is called phosphorescence. 42. Mention the different parts of vertical deflection system. Input selector switch, Input attenuator, Vertical amplifier and Probe PART B 1. Describe the working of digital storage oscilloscope with the neat sketch and how is it different from analog storage oscilloscope. With a neat diagram explain the function of storage oscilloscope (Nov/dec 2011) Describe the working of digital storage oscilloscope with the neat sketch and how is it different from analog storage oscilloscope. DIGITAL STORAGE OSCILLOSCOPE Storage cathode ray tube has several limitations. They are as follows, 1. There is a short duration of time, in which it can preserve a stored waveform, so the waveform may lose. 2. Trace of storage tube is not as fine as that of a normal CRT. 3. Writing rate of the storage tube is less than that of a conventional CRT which in turn limits the speed of the analog storage oscilloscope. 4. It is more expensive than a conventional CRT and requires additional power supplies. 5. Only one image can be stored. For comparing two traces they are to be superimposed on the same and displayed together. Digital storage oscilloscope is used to limit these limitations. In DSO, the waveform to be stored is digitized, stored in a digital memory and retrieved for display on the storage oscilloscope EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 9 Stored waveform is continuously displayed by repeatedly scanning it. Therefore a conventional CRT can also be used for the display. The stored display can be displayed continuously as long as the power is applied to the memory, which can be supplied from a small battery. Digitized waveform can be analyzed by oscilloscope or by reading the contents of the memory into the computer. Display of the stored data is possible in both amplitude versus time and x-y modes. In DSO, fast memory readout is used for CRT display in addition to this a slow readout is also possible which is used for development of hard copy externally. Figure shows the block diagram of DSO, which consists of, 1. Data acquisition 2. Storage 3. Data display. Data acquisition is earned out with the help of both analog to digital and digital to analog converters, which is used for digitizing, storing and displaying analog waveforms. Overall operation is controlled by control circuit which is usually consists of microprocessor Data acquisition portion of the system consist of a Sample-and-Hold (S/H) circuit and an analog to digital converter (ADC) which continuously samples and digitizes the input signal at a rate determined by the sample clock and transmit the digitized data to memory for storage. The control circuit determines whether the successive data points are stored in successive memory location or not, which is done by continuously updating the memories. When the memory is full, the next data point from the ADC is stored in the first memory location writing over the old data. The data acquisition and the storage process is continues till the control circuit receive a trigger signal from either the input waveform or an external trigger source. When the triggering occurs, the system stops and enters into the display mode of operation in which all or some part of the memory data is repetitively displayed on the cathode ray tube. In display operation, two DACs are used which gives horizontal and vertical deflection voltage for the CRT Data from the memory gives the vertical deflection of the electron beam, while the time base counter gives the horizontal deflection in the form of staircase sweep signal. The screen display consist of discrete dots representing the various data points but the number of dot is very large as 1000 or more that they tend to blend together and appear to be a smooth EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 10 continuous waveform. The display operation ends when the operator presses a front-panel button and commands the digital storage oscilloscope to begin a new data acquisition cycle. 2. DIFFERENCE BETWEEN DIGITAL CONVENTIONAL STORAGE OSCILLOSCOPE STORAGE OSCILLOSCOPE EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE AND Page 11 3. Explain Lissajous figures as a method of measuring frequency in oscilloscope with a neat diagram. (May 2008) Lissajous Figures: When sine-wave signals of different frequencies are input to the horizontal and vertical amplifiers a stationary pattern is formed on the CRT when the ratio of the two frequencies is an integral fraction such as 1/2, 2/3, 4/3, 1/5, etc. These stationary patterns are known as Lissajous figures and can be used for comparison measurement of frequencies. Use two oscillators to generate some simple Lissajous figures like those shown in Fig. 5. You will find it difficult to maintain the Lissajous figures in a fixed configuration because the two oscillators are not phase and frequency locked. Their frequencies and phase drift slowly causing the two different signals to change slightly with respect to each other. Testing what you have learned: Your instructor will provide you with a small oscillator circuit. Examine the input to the circuit and output of the circuit using your oscilloscope. Measure such quantities as the voltage and frequency of the signals. Specify if they are sinusoidal or of some other wave character. If square wave, measure the frequency of the wave. Also, for square waves, measure the on time (when the voltage is high) and off time (when it is low). 4.With circuit diagrams explain the working of electronic multimeter,the resistance range selected circuit and commercially available VOM. Discuss the measurement of DC and AC voltages and currents using an Electronic Multimeter. (8) APRIL/MAY 2011 QUANTITIES MEASURED Contemporary multimeters can measure many quantities. The common ones are: Voltage, alternating and direct, in volts. EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 12 Current, alternating and direct, in amperes. The frequency range for which AC measurements are accurate must be specified. Resistance in ohms. Temperature in degrees Celsius or Fahrenheit, with an appropriate temperature test probe, often a thermocouple. DIGITAL MULTIMETERS MAY ALSO INCLUDE CIRCUITS FOR: Continuity; beeps when a circuit conducts. Diodes (measuring forward drop of diode junctions, i.e., diodes and transistor junctions) and transistors (measuring current gain and other parameters). Battery checking for simple 1.5 volt and 9 volt batteries. This is a current loaded voltage scale. Battery checking (ignoring internal resistance, which increases as the battery is depleted), is less accurate when using a DC voltage scale. VARIOUS SENSORS CAN BE ATTACHED TO MULTIMETERS TO TAKE MEASUREMENTS SUCH AS: Light level Acidity/Alkalinity Wind speed Relative humidity DIGITAL The resolution of a multimeter is often specified in "digits" of resolution. For example, the term 5½ digits refers to the number of digits displayed on the display of a multimeter. By convention, a half digit can display either a zero or a one, while a three-quarters digit can display a numeral higher than a one but not nine. Commonly, a three-quarters digit refers to a maximum value of 3 or 5. The fractional digit is always the most significant digit in the displayed value. A 5½ digit multimeter would have five full digits that display values from 0 to 9 and one half digit that could only display 0 or 1.[3] Such a meter could show positive or negative values from 0 to 199,999. A 3¾ digit meter can display a quantity from 0 to 3,999 or 5,999, depending on the manufacturer. While a digital display can easily be extended in precision, the extra digits are of no value if not accompanied by care in the design and calibration of the analog portions of the multimeter. Meaningful high-resolution measurements require a good understanding EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 13 of the instrument specifications, good control of the measurement conditions, and traceability of the calibration of the instrument. Specifying "display counts" is another way to specify the resolution. Display counts give the largest number, or the largest number plus one (so the count number looks nicer) the multimeter's display can show, ignoring a decimal separator. For example, a 5½ digit multimeter can also be specified as a 199999 display count or 200000 display count multimeter. Often the display count is just called the count in multimeter specifications. ANALOG Resolution of analog multimeters is limited by the width of the scale pointer, vibration of the pointer, the accuracy of printing of scales, zero calibration, number of ranges, and errors due to non-horizontal use of the mechanical display. Accuracy of readings obtained is also often compromised by miscounting division markings, errors in mental arithmetic, parallax observation errors, and less than perfect eyesight. Mirrored scales and larger meter movements are used to improve resolution; two and a half to three digits equivalent resolution is usual (and is usually adequate for the limited precision needed for most measurements). Resistance measurements, in particular, are of low precision due to the typical resistance measurement circuit which compresses the scale heavily at the higher resistance values. Inexpensive analog meters may have only a single resistance scale, seriously restricting the range of precise measurements. Typically an analog meter will have a panel adjustment to set the zero-ohms calibration of the meter, to compensate for the varying voltage of the meter battery. ACCURACY Digital multimeters generally take measurements with accuracy superior to their analog counterparts. Standard analog multimeters measure with typically three percent accuracy,[4] though instruments of higher accuracy are made. Standard portable digital multimeters are specified to have an accuracy of typically 0.5% on the DC voltage ranges. Mainstream bench-top multimeters are available with specified accuracy of better than ±0.01%. Laboratory grade instruments can have accuracies of a few parts per million. Accuracy figures need to be interpreted with care. The accuracy of an analog instrument usually refers to full-scale deflection; a measurement of 10V on the 100V scale of a 3% meter is subject to an error of 3V, 30% of the ANALOG MULTIMETERS A multimeter may be implemented with a galvanometer meter movement, or with a bargraph or simulated pointer such as an LCD or vacuum fluorescent display. Analog EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 14 multimeters are common; a quality analog instrument will cost about the same as a DMM. Analog multimeters have the precision and reading accuracy limitations described above, and so are not built to provide the same accuracy as digital instruments. Analog meters, with needle able to move rapidly, are sometimes considered better for detecting the rate of change of a reading; some digital multimeters include a fastresponding bar-graph display for this purpose. A typical example is a simple "good/no good" test of an electrolytic capacitor, which is quicker and easier to read on an analog meter. The ARRL handbook also says that analog multimeters, with no electronic circuitry, are less susceptible to radio frequency interference. The meter movement in a moving pointer analog multimeter is practically always a moving-coil galvanometer of the d'Arsonval type, using either jeweled pivots or taut bands to support the moving coil. In a basic analog multimeter the current to deflect the coil and pointer is drawn from the circuit being measured; it is usually an advantage to minimize the current drawn from the circuit. The sensitivity of an analog multimeter is given in units of ohms per volt. For example, an inexpensive multimeter would have a sensitivity of 1000 ohms per volt and would draw 1 milliampere from a circuit at the full scale measured voltage.[20] More expensive, (and mechanically more delicate) multimeters would have sensitivities of 20,000 ohms per volt or higher, with a 50,000 ohms per volt meter (drawing 20 microamperes at full scale) being about the upper limit for a portable, general purpose, non-amplified analog multimeter. To avoid the loading of the measured circuit by the current drawn by the meter movement, some analog multimeters use an amplifier inserted between the measured circuit and the meter movement. While this increased the expense and complexity of the meter and required a power supply to operate the amplifier, by use of vacuum tubes or field effect transistors the input resistance can be made very high and independent of the current required to operate the meter movement coil. Such amplified multimeters are called VTVMs (vacuum tube voltmeters), TVMs (transistor volt meters), FET-VOMs, and similar names. Quantity to a reference voltage or resistance. While useful in the lab, the devices were very slow and impractical in the field. These galvanometers were bulky and delicate. The D'Arsonval/Weston meter movement used a fine metal spring to give proportional measurement rather than just detection, and built-in permanent field magnets made deflection independent of the 3D orientation of the meter. These features enabled dispensing with Wheat stone bridges, and made measurement quick and easy. By adding a series or shunt resistor, more than one range of voltage or current could be measured with one movement. Multimeters were invented in the early 1920s as radio receivers and other vacuum tube electronic devices became more common. The invention of the first multimeter is EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 15 attributed to United States Post Office (USPS) engineer, Donald Macadie, who became dissatisfied with having to carry many separate instruments required for the maintenance of the telecommunications circuits.[1] Macadie invented an instrument which could measure amperes (aka amps), volts and ohms, so the multifunctional meter was then named Avometer.[2] The meter comprised a moving coil meter, voltage and precision resistors, and switches and sockets to select the range. Macadie took his idea to the Automatic Coil Winder and Electrical Equipment Company (ACWEEC, founded in ~1923).[2] The first AVO was put on sale in 1923, and although it was initially a DC. Many of its features remained almost unaltered through to the last reading. Digital meters usually specify accuracy as a percentage of reading plus a percentage of full-scale value, sometimes expressed in counts rather than percentage terms. Quoted accuracy is specified as being that of the lower millivolt (mV) DC range, and is known as the "basic DC volts accuracy" figure. Higher DC voltage ranges, current, resistance, AC and other ranges will usually have a lower accuracy than the basic DC volts figure. AC measurements only meet specified accuracy within a specified range of frequencies. Manufacturers can provide calibration services so that new meters may be purchased with a certificate of calibration indicating the meter has been adjusted to standards traceable to, for example, the US National Institute of Standards and Technology (NIST), or other national standards laboratory. Test equipment tends to drift out of calibration over time, and the specified accuracy cannot be relied upon indefinitely. For more expensive equipment, manufacturers and third parties provide calibration services so that older equipment may be recalibrated and recertified. The cost of such services is disproportionate for inexpensive equipment; however extreme accuracy is not required for most routine testing. Multimeters used for critical measurements may be part of a metrology program to assure calibration. SENSITIVITY AND INPUT IMPEDANCE When used for measuring voltage, the input impedance of the multimeter must be very high compared to the impedance of the circuit being measured; otherwise circuit operation may be changed, and the reading will also be inaccurate. Meters with electronic amplifiers (all digital multimeters and some analog meters) have a fixed input impedance that is high enough not to disturb most circuits. This is often either one or ten megaohms; the standardization of the input resistance allows the use of external high-resistance probes which form a voltage divider with the input resistance to extend voltage range up to tens of thousands of volts. Modern multimeters are often digital due to their accuracy, durability and extra features. In a digital multimeter the signal under test is converted to a voltage and an amplifier with electronically controlled gain preconditions the signal. A digital multimeter displays the quantity measured as a number, which eliminates parallax errors. EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 16 Modern digital multimeters may have an embedded computer, which provides a wealth of convenience features. Measurement enhancements available include: Auto-ranging, which selects the correct range for the quantity under test so that the most significant digits are shown. For example, a four-digit multimeter would automatically select an appropriate range to display 1.234 instead of 0.012, or overloading. Auto-ranging meters usually include a facility to 'freeze' the meter to a particular range, because a measurement that causes frequent range changes is distracting to the user. Other factors being equal, an auto-ranging meter will have more circuitry than an equivalent, non-auto-ranging meter, and so will be more costly, but will be more convenient to use. Auto-polarity for direct-current readings, shows if the applied voltage is positive (agrees with meter lead labels) or negative (opposite polarity to meter leads). Sample and hold, which will latch the most recent reading for examination after the instrument is removed from the circuit under test. Current-limited tests for voltage drop across semiconductor junctions. While not a replacement for a transistor tester, this facilitates testing diodesand a variety of transistor types. A graphic representation of the quantity under test, as a bar graph. This makes go/nogo testing easy, and also allows spotting of fast-moving trends. A low-bandwidth oscilloscope. Automotive circuit testers, including tests for automotive timing and dwell signals Simple data acquisition features to record maximum and minimum readings over a given period, or to take a number of samples at fixed intervals integration with tweezers for surface-mount technology. A combined LCR meter for small-size SMD and through-hole components. Modern meters may be interfaced with a personal computer EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 17 5.How is phase angle and magnitude of a component measured using vector impedance meter (May 2008) CATHODE RAY OSCILLOSCOPES The cathode ray oscilloscope is an extremely useful and versatile laboratory instrument used for studying wave shapes of alternating currents and voltages as well as for measurement of voltage, current, power and frequency, in fact, almost any quantity that involves amplitude and waveform. It allows the user to see the amplitude of electrical signals as a function of time on the screen. It is widely used for trouble shooting radio and TV receivers as well as laboratory work involving research and” design. It can also be employed for studying the wave shape of a signal with respect to amplitude distortion and deviation from the normal. In true sense the cathode ray oscilloscope has been one of the most important tools in the design and development of modern electronic circuits. BLOCK DIAGRAM OF A CRO CRO BLOCK DIAGRAM A general purpose oscilloscope consists of following parts. EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 18 1. 2. 3. 4. 5. 6. 7. Cathode ray tube Vertical amplifier Delay line Time base circuit Horizontal amplifier Trigger circuit Power supply. 1.Cathode Ray Tube It is the heart of the oscilloscope. When the electrons emitted by the electron gun strikes the Phosphor screen of the CRT, a visual signal is displayed on the CRT. 2. Vertical Amplifier The vertical amplifier amplifies the input signals. Usually, the vertical amplifier is a wide band amplifier, which passes the entire band of frequencies. 3. Delay Line As the name suggests that, this circuit is used to, delay the signal for a period of time in the Vertical section of CRT. The input signal is not applied directly to the vertical plates because the part of the signal gets lost, when the delay Time not used. Therefore, the input signal is delayed by a period of time. 4. Time Base Circuit Time base circuit uses a uni junction transistor, which is used to produce the sweep. The saw tooth voltage produced by the time base circuit is required to deflect the beam in the horizontal section. The spot is deflected by the saw tooth voltage at a constant time dependent rate. 5. Horizontal Amplifier The saw tooth voltage produce by the time base circuit is amplified by the horizontal amplifier before it is applied to horizontal deflection plates 6. Trigger Circuit The signals which are used to activate the trigger circuit are converted to trigger pulses for theprecision sweep operation whose amplitude is uniform. Hence input signal and the sweep frequency can be synchronized. 7. Power supply: The voltages require by CRT, horizontal amplifier and vertical amplifier are provided by the power supply block. Power supply block of oscilloscope is classified in to two types (1) Negative high voltage supply (2) Positive low voltage supply The voltages of negative high voltage supply is from -1000V to -1500V.The range of positive voltage supply is from 300V to 400V EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 19 CATHODE RAY TUBE (CRT), The instrument employs a cathode ray tube (CRT), which is the heart of the oscilloscope. It generates the electron beam, accelerates the beam to a high velocity, deflects the beam to create the image, and contains a phosphor screen where the electron beam eventually becomes visible. For accomplishing these tasks various electrical signals and voltages are required, which are provided by the power supply circuit of the oscilloscope. Low voltage supply is required for the heater of the electron gun for generation of electron beam and high voltage, of the order of few thousand volts, is required for cathode ray tube to accelerate the beam. Normal voltage supply, say a few hundred volts, is required for other control circuits of the oscilloscope. Horizontal and vertical deflection plates are fitted between electron gun and screen to deflect the beam according to input signal. Electron beam strikes the screen and creates a visible spot. This spot is deflected on the screen in horizontal direction (X-axis) with constant time dependent rate. This is accomplished by a time base circuit provided in the oscilloscope. The signal to be viewed is supplied to the vertical deflection plates through the vertical amplifier, which raises the potential of the input signal to a level that will provide usable deflection of the electron beam. Now electron beam deflects in two directions, horizontal on X-axis and vertical on Y-axis. A triggering circuit is provided for synchronizing two types of deflections so that horizontal deflection starts at the same point of the input vertical signal each time it sweeps. A basic block diagram of a general purpose oscilloscope is shown in figure. Cathode ray tube and its various components will be discussed in the following Arts. BASIC FEATURES OF A CRT Electrostatic CRTs are available in a number of types and sizes to suit individual requirements. The important features of these tubes are as follows. 1. Size: Size refers to the screen diameter. CRTs for oscilloscopes are available in sizes of 1, 2, 3, 5, and 7 inches. 3 inches is most common for portable instruments For example a CRT having a number 5GPI . The first number 5 indicates that it is a 5 inch tube. Both round and rectangular CRTs are found in scopes today. The vertical viewing size is 8 cm and horizontal is l0 cm. EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 20 2. Phosphor: The screen is coated with a fluorescent material called phosphor. This material determines the color and persistence of the trace, both of which are indicated by the phosphor. The trace colors in electrostatic CRTs for oscilloscopes ale blue, green and But green. White is used in TVs. and blue-white, orange, and yellow are used for radar Persistence is expressed as short, medium and long. This refers to the length of time the trace remains on the screen after the signal has ended. The phosphor of the oscilloscope is designated as follows. Pl --Green medium P2--Blue green medium P5—Blue very short P11--Blue short These designations are combined in the tube type number. Hence 5GPl is a 5 inch tube with a medium persistence green trace. Medium persistence traces are mostly used for general purpose applications Long persistence traces are used for transients, since they keep the fast transient on the screen for observation after the transient has disappeared Short persistence is needed for extremely high speed phenomena, to prevent smearing and interference caused when one image persists and overlaps with the next one.P11 phosphor is considered the best for photographing from the CRT screen. 3. Operating Voltages: the CRT requires a heater voltage of 6'3 volts ac or dc at 600mA. Several dc voltages are listed below. The voltages vary with the type of tube used. (i) Negative grid (control) voltage 14 V to - 200 V. (ii) Positive anode no. 1 (focusing anode) -100 V to - ll00 V (iii) Positive anode no. 2 (accelerating anode) 600 V to 6000 V (iv) Positive anode no. 3 (accelerating anode) 200 v to 20000 V in some cases 4. Deflection Voltages: Either ac or dc voltages will deflect the beam. The distance through which the spot moves on the screen is proportional to the dc, or peak ac amplitude. The deflection sensitivity of the tube is usually stated as the dc voltage (or peak ac voltage) required for each cm of deflection of the spot on the screen 5. Viewing Screen: The viewing screen is the glass faceplate, the inside wall of which is coated with phosphor. The viewing screen is a rectangular screen having graticules marked on it. The standard size used nowadays is 8 cm x l0 cm (8 cm on the vertical and 10 cm on horizontal).Each centimeter on the graticule corresponds to one division (div). The standard phosphor color use d nowadays is blue EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 21 APPLICATIONS OF CRO Electricians use them to view signal voltages, usually as a two-dimensional graph of one or more electrical potential differences (vertical axis) plotted as a function of time or of some other voltage (horizontal axis). Oscilloscopes are used in the 1.sciences 2. Medicine 3.engineering 4.Telecommunications 5. Industry. 6. Laboratory experiments Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system, or to display the waveform of the heartbeat. laboratory experiments 6.Draw the block diagram of sampling oscilloscope and explain the principle. (8) (APRIL/MAY 2011) With a help of block diagram explain the working of sampling oscilloscope.Draw the block diagram of sampling oscilloscope. How does the sampling oscilloscope apparent frequency response of oscilloscope (Nov/Dec 2012) SAMPLING OSCILLOSCOPE An ordinary oscilloscope has a B.W. of 10 MHz the HF performance can be improved by means of sampling the input waveform and reconstructing its shape from the sample, i.e. the signal to be observed is sampled and after a few cycles sampling point is advanced and another sample is taken. The shape of the wave form is reconstructed by joining the sample levels together. The sampling frequency may be as low as 1/10th of the input signal frequency (if the input signal frequency is 100 MHz, the bandwidth of the CRO vertical amplifier can be as low as 10 MHz). As many as 1000 samples are used to EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 22 reconstruct the original waveform. Fig shows a block diagram of a sampling oscilloscope. The input is applied to the sampling gate. The input waveform is sampled whenever a sampling pulse opens the sampling gate. The sampling must be synchronized with the input signal frequency. The signal is delayed in the vertical amplifier, allowing the horizontal sweep to be initiated by the input signal. The waveforms are shown in fig 4.2 At the beginning of each sampling cycle, the trigger pulse activates an oscillator and a linear ramp voltage is generated. This ramp voltage is applied to a voltage comparator which compares the ramp voltage to a staircase generate-When the two voltages are equal in amplitude, the staircase advances one step and a sampling pulse is generated, which opens the sampling gate for a sample of input voltage. The resolution of the final image depends upon the size of the steps of the staircase generator. The smaller the size of the steps the larger the number of samples and higher the resolution of the image 7.Explain the measurement of quality factor of a coil. (8) APRIL/MAY 2011 What is Q-meter? Explain the circuit measurement methods(Nov/dec 2012) How to measure large capacitor and small coil using Qmeter((Nov/dec 2012)) EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 23 The Q factor or quality factor of an inductance is commonly expressed as the ratio of its series reactance to its series resistance. We can also express the Q factor of a capacitance as the ratio of its series reactance to its series resistance although capacitors are generally specified by the D or dissipation factor, which is the reciprocal of Q. A tuned circuit, at resonance, is considered to have a Q factor. In this case, Q is equal to the ratio of either the inductive reactance, or the capacitive reactance, to the total series loss resistance in the tuned circuit. The greater the loss resistance and the lower the Q, the greater the power lost on each cycle of oscillation in the tuned circuit and hence the greater the power needed to maintain oscillation. Another way to derive Q is as follows: Q = fo/Δf where fo is the resonant frequency Δf is the 3 dB bandwidth Finally, Q factor of a resonant circuit is equal to its voltage magnification factor and Q can also be expressed as the ratio of voltage developed across its reactive elements to the voltage injected in series with the circuit to produce the developed voltage. To measure Q factor, Q meters make use of this principle. PRINCIPLE A basic Q meter is shown in Figure 1. Terminals are provided to connect the inductance (Lx) to be measured and this is resonated by a variable tuning capacitor (C). Terminals are also provided to add capacitance (Cx), if required. The tuned circuit is excited from a tunable signal source which develops voltage across a resistor in series with the tuned circuit. The resistor must have a resistance small compared to the loss resistance of the components to be measured so that its value can be ignored. A resistance of a mere fraction of an ohm is necessary. Metering is provided to measure the AC injection voltage across the series resistor and the AC output voltage across the terminals of the tuning capacitor. The output measurement must be a high input impedance circuit to prevent loading of the tuned circuit by the metering circuit EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 24 BASIC Q METER Q is measured by adjusting the source frequency and/or the tuning capacitor for a peak in output voltage corresponding to resonance. Q factor is calculated as the ratio of output voltage measured across the tuned circuit to that injected into it. In practice, the signal source level is generally set for a calibrate point on the meter which measures injected voltage and Q is directly read from calibration on the meter which measures output voltage. APPLICATIONS OF Q METER The Q meter can be used for many purposes.It can measure Q and is generally used to check the Q factor of inductors. As the internal tuning capacitor has an air dielectric its loss resistance is negligible compared to that of any inductor and hence the Q measured is that of the inductor. The value of Q varies considerable with different types of inductors used over different ranges of frequency. Miniature commercial inductors, such as the Siemens B78108 types or the Lenox-Fugal Nanored types, made on ferrite cores and operated at frequencies up to 1 MHz, have typical Q factors in the region of 50 to 100. Air wound inductors with spaced turns, such as found in transmitter tank circuits and operating at frequencies above 10 MHz, can be expected to have Q factors of around 200 to 500. Some inductors have Q factors as low as five or 10 at some frequencies and such inductors are generally unsuitable for use in selective circuits or in sharp filters. The Q meter is very useful to check these out. The tuning capacitor (C) of the Q meter has a calibrated dial marked in pico-farads so that, in conjunction with the calibration of the oscillator source, the value of inductance (Lx) can be derived. The tuned circuit is simply set to resonance by adjusting the frequency and/or the tuning capacitor for a peak in the output voltage meter and then calculating the inductance (Lx) from the usual formula: Lx = 1/4π²f²C For L in μH, C in pF and f in MHz this reduces to: 25330/f²C Another use of the Q meter is to measure the value of small capacitors. EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 25 DISTRIBUTED COIL CAPACITANCE Direct measurement of Q in an inductor, as discussed in previous paragraphs. is based on the circuit having two components, inductance and capacitance. Inductors also have distributed capacitance (Cd) and if this represents a significant portion of the total tuning capacitance, the Q value read will be lower than its actual value. High distributed capacitance is common in large value inductors having closely wound turns or having multiple layers. Actual Q can be calculated from Qe, as read, from the following: Q = Qe (1 + Cd/C) where Cd = Distributed capacitance and C = Tuning Capacitance Resonating with a large value of tuning capacitance reduces Q value error, otherwise distributed capacitance can be measured and applied to the previous formula. Two methods of measuring distributed capacitance are described in the "Boonton Q Meter Handbook". The simplest of these is said to be accurate for distributed capacitance above 10 pF and this method is described as follows: 1. With the tuning capacitor (C) set to value C1 (say 50 pF), resonate with the sample inductor by adjusting the signal source frequency. 2. Set the signal source to half the original frequency and re-resonate by adjusting C to a new value of capacitance C2. 3. Calculate distributed capacitance as follows: Cd = (C2 -4C1) /3 Another effect of distributed capacitance in the inductor is to make its inductance value (as calculated from the calibration of the tuning capacitance and the calibration of the signal source) appear higher than its actual value. Again, this error can be reduced by tuning with a large value of capacitance C and/or adding Cd to C in the calculation. EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 26 8..Draw the block diagram of True RMS reading voltmeter and explain its operation. (8) APRIL/MAY 2011 TRUE RMS METERS RMS: The ‘Root Mean Square’ magnitude of an alternating current is the value of equivalent direct current that would produce the same amount of heat in a fixed resistive load. The amount of heat produced in a resistor by an alternating current is proportional to the square of the current averaged over a full cycle of the waveform. In other words, the heat produced is proportional to the mean of the square, so the current value is proportional to the root of the mean of the square or RMS. TRUE RMS METER A true RMS meter works by taking the square of the instantaneous value of the input current, averaging over time and then displaying the square root of this average. Perfectly implemented, this is absolutely accurate whatever the waveform. Implementation is, of course, never perfect and there are two limiting factors to be taken into account: frequency response and crest factor. For power systems work it is usually sufficient to measure up to the 50th harmonic, i.e up to a frequency of about 2500 Hz. The crest factor, the ratio between the peak value and the RMS value, is important; a higher crest factor requires a meter with a greater dynamic range and therefore higher precision in the conversion circuitry. A crest factor capability of at least three is required.It is worth noting that, despite giving different readings when used to measure distorted waveforms, meters of both types would agree if used to measure a perfect sinewave. This is the condition under which they are calibrated, so each meter could be certified as calibrated – but only for use on sinewaves. True RMS meters have been available for at least the past 30 years, but they used to be specialised and expensive instruments. Advances in electronics have now resulted in true RMS measurement capability being built into many handheld multimeters. Unfortunately, this feature is generally found only towards the top end of most manufacturers’ ranges, but they are still cheap enough to buy as ordinary instruments for everyone and everyday. The consequences of under measurement The limiting rating for most electrical circuit elements is determined by the amount of heat that can be dissipated so that the element or component does not overheat. Cable ratings, for example, are given for particular installation conditions (which determine how fast heat can escape) and a maximum working temperature. Since harmonic polluted currents have a higher RMS EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 27 value than that measured by an averaging meter, cables may have been under-rated and will run hotter than expected; the result is degradation of the insulation, premature failure and the risk of fire.Busbars are sized by calculating the rate of heat loss from the bars by convection and radiation and the rate of heat gain due to resistive losses. The temperature at which these rates are equal is the working temperature of the busbar, and it is designed so that the working temperature is low enough so that premature ageing of insulation and support materials does not result. As with cables, errors measuring the true RMS value will lead to higher running temperatures. Since busbars are usually physically large, skin effect is more apparent than for smaller conductors, leading to a further increase in temperature. Other electrical power system components such as fuses and the thermal elements of circuit breakers are rated in RMS current because their characteristics are related to heat dissipation. This is the root cause of nuisance tripping – the current is higher than expected so the circuit breaker is operating in an area where prolonged use will lead to tripping. The response of a breaker in this region is temperature sensitive and may appear to be unpredictable. As with any supply interruption, the cost of failure due to nuisance tripping can be high, causing loss of data in computer systems, disruption of process control systems, etc. Obviously, only true RMS instruments will give the correct measurements so that the ratings of cables, busbars and breakers can be determined properly. An important question is, ‘Is this meter a true RMS meter?’ Usually, if a meter is a true RMS meter it will say so quite prominently in the product specification but this is often not available when needed. A good idea of the answer can be obtained by comparing measurements with a known averaging meter (usually the cheapest to hand!) or a known true RMS meter while measuring the current in a non-linear load such as a PC and the current drawn by a filament lamp. Both meters should read the same current for the filament lamp load. If one instrument reads significantly (say more than 20 %) higher for the PC load than the other then it is probably a true RMS instrument, if the readings are similar, the meters are of the same type. True RMS measurement is essential in any installation where there is a significant number of non-linear loads (PCs, electronic ballasts, compact fluorescent lamps, etc.). Averaging reading meters will give an under measurement of up to 40 % which can result in cables and circuit breakers being under rated with the risk of failure and nuisance tripping. 9.Explain vector impedance meter with block diagram (Nov/Dec 2012) How is phase angle and magnitude of a component measured using vector impedance meter EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 28 VECTOR IMPEDANCE METER An instrument that not only determines the ratio between voltage and current, to give the magnitude of impedance, but also determines the phase difference between these quantities, to give the phase angle of impedance. A vector impedance meter is used to measure impedance and phase angle, this is done by calculating voltage and current through an impedance and then calculating Z and phase angle with that, now there are two modes for operation i.e constant current mode and constant voltage mode. CONSTANT CURRENT MODE CONSTRUCTION: First of all there is a wien bridge oscillator(w) to choose frequency then an AGC amplifier(a) to regulate current then a z switch control(zs) which regulates gain of AGC amplifer, feedback to AGC amplifier is done by an dc differential amplifier(dc) now there is an ac differential amplifier too(ac) which gets one input from the z switch and one from the unknown impedance(imp), and there is a transconductance amplifier too which gets one of his input from the unknown impedance Working: In constant current mode we have to maintain constant current through impedance so current is made to come to unknown impedance from z switch, then that current goes through trans-resistance amplifier, which converts that current to a voltage that is sent to a dc differential amplifier and is compared with a reference voltage in dc differential amplifier then the difference between voltages is amplified and sent to AGC amplifier, so AGC together with z switch this way maintains constant current through unknown impedance, now for calculation z-magnitude,sc differential amplifier gets input from unknown impedance and z switch, so difference is amplified and sent to a band pass filter which filters out then the filtered signal is sent to a z-magnitude meter which is calibrated to read z directly. 10.How to measure the RF voltage and power using RF millivolt meter(Nov/Dec 2012) Briefly discuss the problems in RF power measurements. DIGITAL READ OUT OSCILLOSCOPE The digital read out oscilloscope instrument has a CRT display and a counter display. The diagram shown is of an instrument where the counter measures the time Fig. BLOCK DIAGRAM EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 29 The input waveform is sampled and the sampling circuit advances the sampling position in fixed increments, a process called strobing. The equivalent me between each sample depends on the numbers of sample taken per cm and the sweep time/cm, e.g. a sweep rate of 1 nano-sec/cm and a sampling rate of J samples/cm gives a time of 10 pico-sec/sample. Figure 9.1 shows a block diagram of a digital read out oscilloscope when measuring voltage.Two intensified portions of the CRT trace identify 0% and 100% zones position. Each zone can be shifted to any part of the display. The voltage divider Bps between the 0% and 100% memory voltage EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 30 are set for start and stop timing, The coincidence of any of the input waveforms with the selected percentage point is sensed by this voltage comparator. The numbers of the clock pulse which correspond to the actual sample taken are read out digitally in a Nixie display tube in ns, μs, ms or seconds. Figure sows a block diagram of a digital readout CRO when used for voltage to time conversion.The CRT display is obtained by sampling the 0% reference voltage as chosen by the memory circuit. A linear ramp generator produces a voltage; when the ramp voltage equals the 0% reference the gate opens. When the ramp equals 100% reference the gate closes. The number of clock pulses that activate the counter is directly proportional to the voltage between the selected references and is read out in Mv or volts by the Nixie tube display (i) A and B Chopped Display Mode In chopped display mode of dual-trace oscilloscope, the electronic switch switches between the channels A and B at very high frequency (usually at 100-500 kHz). Due to very fast switching between the input channels, small segments (of about 1 us duration) of each input waveform get coupled alternately to the vertical amplifier and get traced on the screen. Thus, the display of input signal waveform will be a dashed-line trace of the actual input waveform, with small gaps between its segments. The continuity of the trace of the waveform depends on chopping (i.e., switching) frequency and the frequency of the input signal. Usually, the chopping frequency must be higher than the input signal frequency and sweep frequency. In chop mode, the traces of high frequency signals do not appear continuously as shown in fig Whereas in case of low frequency signals, the gaps between them EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 31 II) A AND B ALTERNATE DISPLAY MODE The alternate display mode also involves alternate switching of the input signals to the vertical amplifier with the help of an electronic switch but at low switching rates. In this mode, the electronic switch is allowed to switch between the input channels at a frequency equal to the sweep frequency. Due to this, the signal on channel A gets connected to the vertical amplifier and is traced on the CRO screen during one sweep. Similarly, the signal on channel B gets traced during the succeeding sweep, as shown in fig 10.2. As the two input waveforms are traced at different times, they do not appear to be displayed simultaneously on the screen. The alternate mode is preferred for high frequency signals (rather than low frequency signals) because the waveform traces appear to be continuous and displayed simultaneously due to high repetition frequency. 11.Explain in detail about DUAL TRACE CRO Dual Trace Oscilloscope Figure shows the block diagram of dual trace oscilloscope which consist of following steps, 1. Single electron gun EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 32 2. Two separate vertical input channels 3. Attenuators and pre-amplifiers 4. Electronic switch. With the help of electronic switching the two separate input signals can be applied to single electron gun. Produces a dual trace display. Each separate vertical input channel uses separate attenuators and pre-amplifier stages, so, that the amplitude of each signal can be independently controlled. Output of the pre-amplifiers is given to the electronic switch, which passes one signal at a time into the main vertical amplifier of the oscilloscope. The time base-generator is similar to that of single input oscilloscope. By using switch S2 the circuit can be triggered on either A or B channel, waveforms, or an external signal, or on line frequency. The horizontal amplifier can be fed from sweep generator or from channel B by switching S1. When switch S, is in channel B, its oscilloscope operates in the X-Y mode in which channel A acts as the vertical input signal and channel B as the horizontal input signal. From the front panel several operating modes can be selected for display, EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 33 like channel B only, channel A only, channels B and A as two traces, and signals A + B, A - B, B ~ A or - (A + B) as a single trace. Two types of common operating mode are there for the electronic switch, namely, 1. Alternate mode 2. Chop mode. 1. Alternate Mode In case of alternate mode, electronic switch alternately connects the main vertical amplifier to channel A and B and adds a different D.C. component to each signal. Due to this D.C. component the beam alternately goes to the upper and lower half of the screen. Switching is carried out at the start of each new sweep of the time base generator. To obtain the cathode ray tube spot it traces the channel A signal on one sweep and the channel B signal on the succeeding sweep. The switching rate of the electronic switch is synchronized to the sweep rate. The alternate mode cannot be used for displaying very low frequency signals. 2. Chop Mode In chop mode electronic switch runs at a very high frequency of the order of 100-500 kHz. This results in connecting small segment of waveform A and waveform B, alternately to vertical amplifier to display it on the screen. The display will be a continuous line for each channel when chopping rate much faster than horizontal sweep rate. In case when the chopping rate is slow the continuity of the display is lost hence it is preferable to use alternate mode of operation EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 34 ADVANTAGES OF DUAL BEAM FOR MULTIPLE TRACE OSCILLOSCOPES 1. A multiple trace oscilloscope making use of dual beam provides a simultaneous display of the two input waveforms on the CRO screen. Hence dual beam CRO is used to compare one signal with another signal. 2. It can capture two fast transient events. 3. It also provides a continuous display of the signals, whereas the display of the two signals provided by a dual trace oscilloscope consists of small gaps in the trace. 4. It has two separate vertical channels for two input signals. 5. It can also have two separate time base circuits (i.e. horizontal deflection systems). Hence, in dual beam CRO two input signals can be swept horizontally at different rates. Due to this feature,a fast signal can be graphically compared with a slow signal simultaneously on the CRO screen. 12. Explain in detail about TIME BASE OSCILLOSCOPES Triggered Sweep CRO The continuous sweep is of limited use in displaying periodic signals of constant frequency and amplitude. When attempting to display voice or music signals, the pattern falls in and out of sync as the frequency and amplitude of the music varies resulting in an unstable display. A triggered sweep can display such signals, and those of short duration, e.g. narrow pulses. In triggered mode, the input signal is used to generate substantial pulses that EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 35 trigger the sweep. Thus ensuring that the sweep is always in step with the signal that drives it. As shown in Fig. resistance R3 and R 4 form a voltage divider such that the voltage Vo at the cathode of the diode is below the peak voltage i/o for UJT conduction. When the circuit is switched on, the UJT is in the non-conducting stage, and C, charges exponentially through RT. towards VBB until the diode becomes forward biased and conducts; the capacitor voltage never reaches the peak voltage required for UJT conduction but is clamped at Vo. If now a –ve pulse of sufficient amplitude is applied to the base and the peak voltage Vp is momentarily lowered, the UJT fires. As a result, capacitor C. discharges rapidly through the UJT until the maintaining voltage of the UJT is reached; at this point the UJT switches off and capacitor CT charges towards VBB, until it is clamped again at VD fig shows the output waveform EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 36 13.Explain about DELAYED TIME BASE OSCILLOSCOPES DELAY LINE IN TRIGGERED SWEEP CIRCUIT Fig indicates the amplitude of the signal raise time and the relative position of the sweep generator output signal The diagram shows that when the delay line is not used, the initial part of the signal is lost and only part of the signal is displayed. To counteract this disadvantage the signal is not applied directly to the vertical plates but is passed through a delay line circuit, as shown in Fig.7.13. This gives time for the sweep to start at the horizontal plates before the signal has reached the vertical plates. The trigger pulse is picked off at a time t0 after the signal has passed through the main amplifier. The sweep generator delivers the sweep to the horizontal amplifier and the sweep starts at the HDP at time t0 + 80 ns. Hence the sweep starts well in time, since the signal arrives at the VDP at time t0 + 200 ns EC2351–Measurements and Instrumentation VI Sem ECE – R.Vanitha,AP/ECE Page 37