* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Page 1 of 12
Portable appliance testing wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Current source wikipedia , lookup
History of electric power transmission wikipedia , lookup
Power inverter wikipedia , lookup
Electrical substation wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Three-phase electric power wikipedia , lookup
Stray voltage wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Buck converter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
Opto-isolator wikipedia , lookup
Rectiverter wikipedia , lookup
PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. Dt of Revision : 02 : 17.9.2012 Issue No : 2 Issue Dt. : 30.06.2003 Page No. : 1 OF 3 Issued by Section Topic : QA Document : 0 : FORMAT 6 OF PROCUREMENT PROCEDURE OF CPRI (NON-WORKS) : DQM-01 FORMAT NO.:PUR/TENDDOC/P6/06 CPRI www.tenderwizard.com/CPRI Section II -Technical Specification Tender Enquiry No : PUR/ID-32/17-18 Name of the Equipment: Damped Oscillatory and Ring wave generator Note : 1) The Offers should be submitted only in this format otherwise the offer will be liable for rejection 2) All blue fields are mandatorily to be filled(mention NA or 0 wherever not applicable). 3) Pre-despatch Inspection & Training expenses shall be borne by CPRI. Information regarding the readiness of the equipment/machinery for the Pre-despatch Inspection should be sent in writing by the supplier atleast 70 (Seventy) days in advance, so as to obtain clearence from the concerned Ministries of Government of India for deputation of nominated CPRI officers by the Director General. A detailed technical catalogue/literature/phamplet and any other technical details shall be sent in hard copy in a sealed cover superscribing enquiry number and due date so as to reach the following address with the due date and time. This is very much essential to evaluate your offer. Name of the Vendor Offer Number and Date Sl.No. Parameters CPRI Specification / Requirements 1 Place where equipment to be supplied CPRI, Bangalore 2 Scope Supply, Installation, Commissioning and Training of 1 Damped Oscillatory and Ring wave Generator. Required generators & CDNs shall be supplied either built-in unit or independent units. Cost of the generators and CDNs shall be supplied separetly, if not included in the cost of the main unit. 3 Pre-qualification The Damped Oscillatory and Ring wave Generator with their CDNs shall have been supplied to at least two NABL accredited Govt. Laboratories. Demonstration of the equipment shall be arranged by the bidder. Page 1 of 12 Qty To be completed by the Bidder Guaranteed Deviation/ Technical Remarks Specify if Particulars (GTP) any 4 Purpose of use To test the Immunity of Electrical & Electronic products (Single phase & Three phase Delta and Star configuration) for Damped oscillations testing in accordance with latest IEC 61000-4-18, IEC 61000-4-10. Whereas Ring wave Immunity Test in accordance with IEC 61000-4-12 standard. 5 Application The equipment shall be suitable to use the generator as stand alone equipment for testing of electrical / electronic Industrial equipment, Telecom equipment etc. Further it shall able to test 'Measuring relays and protection equipment' as per IEC:60255-26. 6 Specifications of Slow & FastDamped Oscillatory wave generator: The quoted 'Slow & Fast Damped Oscillatory Wave Generator', CDNs & Magnetic field coil(s) with appropriate ratings shall meet following required specifications as per latest IEC 61000-4-18, IEC 61000-4-10 standards. A) Characterstics and performance of the slow damped oscillatory wave generator: Generator Specifications as per latest Standard IEC:61000-4-18: Output voltage rise time (T1 in Figure 1 of IEC: 61000-418) shall be 75ns ± 20%, Copy of Figure-1 is enclosed. voltage Oscillation frequecies (defined as the reciprocal of the period between the first and third zero crossings after the initial peak. This period is shown as T in figure1): 100kHz and 1MHz.±10%. Repetition rate: 40/s for 100kHz and 400/s for 1MHz ±10% Decaying (as per Figure 1): Pk5 must be > 50% of the Pk1 value and Pk10 must be <50% of the Pk1 value; Burst duration: Not less than 2 s. output impedance (calculated as open circuit voltage Pk1 divided by short circuit currentPk1) shall be 200 Ohm. Page 2 of 12 Open circuit voltage (Pk1 value): 250V - 3,000V ± 10% at CDN output or better (variable); Models with higher ratings shall be quoted separately. Short circuit current (Pk1 value): 1.25A to 15A ±20% Phase relationship with the power frequency: No requirement Polarity of the first half -period: Both positivie and negative. The schematic circuit diagram of the generator shall be as per Figure 2, copy enclosed. The waveform of the slow damped oscillatory wave with peak point marked is given in Figure 1, copy enclosed. B) Characterstics and performance of the fast damped oscillatory wave generator: Generator Specifications as per Standard IEC:61000-4-18: The output wave of the generator shall be as per Figure 1 of the standard, copy enclosed. Voltage rise time (T1 in Figure1): 5ns ± 30% voltage Oscillation frequecies (defined as the reciprocal of the period between the first and third zero crossings after the initial peak. This period is shown as T in figure1): 3MHz, 10MHz. and 30MHz.±10%. Repetition rate: 5000/s ±10% Decaying (as per Figure 1): Pk5 must be > 50% of the Pk1 value; and Pk10 must be <50% of the Pk1 value; Burst duration: 3MHz: 50ms ±20% 10MHz: 15ms ± 20% 30MHz: 5ms ± 20% Burst perio: 300ms ± 20% Page 3 of 12 output impedance (calculated as open circuit voltage Pk1 divided by short circuit currentPk1): Not less than 50 Ohm ± 20%. Open circuit voltage (Pk1 value): 250V - 4,000V ± 10% at CDN output or better (variable); Indicate other ranges and shall be quoted separately Phase relationship with the power frequency: No requirement Polarity of the first half -period: Both positivie and negative. Specifications of short-circuit: Current rise time (T1 of Figure 1): 3MHz: <330ns 10MHz: <100ns 30MHz: <33ns Current oscillation frequencies (defined as the reciprocal of the period between the first and third zero crossings after the initial peak. This period is shown as T in figure1): 3MHz, 10MHz and 30MHz ±30% Decaying (as per Figure 1): Pk5 must be >25% of the Pk1 value; and Pk10 must be <25% of the Pk1 value; Short circuit current (Pk1 value): 5A to 80A ±20% The schematic circuit diagram of the generator shall be as per Figure 2, copy enclosed. The waveform of the fast damped oscillatory wave is given in Figure 1, copy enclosed. C) Coupling / decoupling network for ac/dc power supply ports(Built in or external): The output waveforms from the coupling / decoupling network shall meet the same requiremnts as define in A & B for the generators themselves. Page 4 of 12 The residual damped oscillatory voltage (from Pk1 to Pk10) on the power supply inputs of the decoupling network when the EUT is disconnected shall not exceed 15% of the applied test voltage or twice the rated peak voltage of the coupling / decoupling network, which ever is higher. Number of phases: Suitable for both single phase and Three phase equipment. The CDN shall comply with all requirements of latest IEC 1+1 61000-4-18. Voltage rating/current ratings of CDN shall be 3x 415V/32A or better, 50/60 Hz & 250V/20A for DC or better. (it shall be suitable for single phase testing also). If cost of the CDN is not included in the cost of the generator, then the cost of the CDN shall quoted seperately. D) Coupling / decoupling network for signal and control ports: The network shall have the same specifications given #C with the exception below: The residual damped oscillatory voltage (from Pk1 to Pk10) on the power supply inputs of the decoupling network when the EUT is disconnected shall not exceed 10% of the applied test voltage or twice the rated peak voltage of the coupling / decoupling network, whichever is higher. The minimum decoupling attenuation may not be sufficient to protect auxiliary signal sources, and additional protection devices may be required. The network shall consist of single units in order to give the possibility of testing input / ouput ports with single circuits or groupling of circuits (for example, multi-wire with a common). The capacitive coupling clamp specified in IEC:61000-4-4 shall be used together with the fast oscillatory wave generator, when the CDN is not suitable for the operating signal of the EUT port to be exercised. If cost of the capacitive coupling clamp is not included in the cost of the generator, then the cost of the capacitive coupling clamp shall quoted seperately. Page 5 of 12 1 Suitable CDN for at least 4 signal / datalines shall be 1 provided for damped oscillatory waves. The CDN shall comply with all requirements of latest IEC 61000-4-18. If cost of the CDN is not included in the cost of the generator, then the cost of the CDN shall quoted seperately. The CDN shall comply with all requirements of latest IEC 1 60255-26. The coupler shall offer capability to test up to 4 pairs / 8 lines. . CDN suitable for conducting immunity test in both differential and common mode for Auxiliary power supply port , Communication port, Input and Output ports. If cost of the CDN is not included in the cost of the generator, then the cost of the CDN shall quoted seperately. Voltage rating/current ratings of CDN shall be 200V/1A or 1+1 better per line for ac (50Hz) and / or dc. If cost of the CDN is not included in the cost of the generator, then the cost of the CDN shall quoted seperately. E) Dampled oscillatory wave generator as per latest standard IEC:61000-4-10: Generator shall be able to deliver the required impulse current to the induction coils specified in clause no. 6.3 of IEC:61000-4-10, The copy is enclosed. The waveform, is specified as a short circuit current and therefore shall be measured with the induction coil connected. The test sytem comprises the damped oscillatory wave generator and the induction coil for a table-top test setup and in addition an RGP for a floor -standing test setup. Performance characterstics of the generator connected to the standard induction coil as per IEC:61000-4-10 shall meet the following requirements: Oscillations period shall be as per Table-3 of IEC:61000-410, copy enclosed. Current in the coils (pk1 value) shall be as per Table-2 of IEC:61000-4-10, copy enclosed. Page 6 of 12 Schematic circuit diagram of the test generator for damped oscillatory magnetic field shall be as per Figure 1, copy enclosed. Waveform of the damped oscillatory magnetic field shall be as per Figure-2 of IEC:61000-4-10, copy enclosed. Decay rate Dr1, Dr2: Pk5 shall be > 50% of the Pk1value and Pk10 shall be <50% of the Pk1 value. Repetition rate 1/Trep (see Figure 3 of IEC:61000-4-10, copy enclosed) shall be 40/s ±10% for 100kHz and 400/s ±10% for 1MHz. Test duration shall not be less than 2s. Phase shifting is not required. Oscillation frequeny is defined as the reciprocal of the period of the first and third zero crossing after the initial peak. This period is shown as T in Figure 2 of IEC:61000-410, copy enclosed. 5 Specifications of Ring wave generator: The quoted generator, CDNs with appropriate ratings shall meet following required specifications as per latest IEC 61000-4-12 standard. 1) Characterstics and performance of the Ring wave generator: Open circuit voltage (Pk1 value in Figure1 of IEC: 61000-412, copy enclosed): 250V - 6,000V ± 10% (variable) or better Voltage Rise time(T1 in Figure1 of IEC: 61000-4-12): 0.5µs ± 30% (open circuit condition) Current Rise time(T1 in Figure1 of IEC: 61000-4-12): ≤1µs (short circuit condition) Voltage oscillation frequency:100 kHz ± 10%. Decaying (Voltage only; see Figure 1 of IEC: 61000-4-12) 0.4<Ratio of Pk2 to Pk1<1.1 Page 7 of 12 0.4<Ratio of Pk3 to Pk2<0.8 0.4<Ratio of Pk4 to Pk3<0.8 No requirements for other peaks. Transient repetion: 1 to 60 transients per minute Output impedance:12 ohm & 30 ohm ± 20% (switchable). Short circuit current (Pk1 value in Figure1 of IEC: 61000-412): 500A ± 10% for 12 ohm generator setting; 200A ± 10% for 30 ohm generator setting; Phase relationship with power frequency shall be in a range between 0 to 360° relative to the phase angle of the ac line voltage to the equipment under test, with a tolerance of ±10° or better. Polarity of the first half-period: positive & negative selectable. Schematic circuit diagram of the test generator for ring wave shall be as per Figure 2 of IEC:61000-4-12, copy enclosed. waveform of the ring wave (open circuit voltage and short circuit current) shall be as per Figure-1 of IEC:61000-4-12, copy enclosed. 2. Coupling/Decoupling network for ac/dc power supply ports as per IEC:61000-4-12: The output wave forms from the coupling/decoupling network shall meet the same requirement of the test generator mentioned above (#1). The a.c. main voltage drop at the EUT connector of the coupling/decoupling network shall be less than 10% at the specified current rating of the coupler. Page 8 of 12 Specifications: The residual surge voltage on the power supply inputs of the decoupling network when the EUT is disconnected shall not exceed 15% of the applied test voltage or twice the rated peak voltage of the coupling/Decoupling network, whichever higher Insulation with stand capability of the coupling devices with the 1.2/50μs wave: 5kV. The CDN shall comply with all requirements of latest IEC 1+1 61000-4-12 . Voltage ratings/current ratings of CDN shall be 3x415V/32A or better for ac(50 Hz) & 250/20A for dc. If cost of the CDN is not included in the cost of the generator, then the cost of the CDN shall quoted seperately. 3) Coupling / decoupling network for signal and control ports: The network as the same specification as given in 2 (as above) with the exception, the residual surge voltage on power supply inputs of decoupling network when the EUT is disconnected shall not exceed 15% of the applied test voltage or twice the rated peak voltage of the coupling/Decoupling network, whichever higher. The minimum decoupling attenuation may not be suffient to protect auxiliary signal sources and additional protection devices may be required. The network may consits of single units in order to give the possibility of testing input/output ports with single circuits or grouping of circuits(for example, multi wire with a common) Coupling/Decoupling network (4 signal/data lines) for 1 unshielded unsymmetrical interconnection lines shall be provided. Voltage / current ratings shall be 200V/3A or better. If cost of the CDN is not included in the cost of the generator, then the cost of the CDN shall quoted seperately. 6 Protection Suitable CDN over current protection shall be provided. Please specify the type of protection. 7 Display LCD display or push button operator & interface remotely to PC. Page 9 of 12 LCD Display to display all programming parameters: Voltage, current, Burst duration, polarity ,frequency etc. shall be displayed simultaneously on the screen. Digital display for indicating Status of the test, test parameters and programming the test. 8 CRO trigger: Suitable Trigger signal for oscilloscope shall be provided. Suitable cable/ probe shall be provided. 9 Communication Interface RS 232/ USB/GPIB/IEEE 488/Ethernet(LAN) remote control interface allow programming of equipment functions from an external computer. 10 Input Supply voltage Single phase, 230V AC +10%/-15%, 50 Hz. Power cord suitable for Indian type conditions shall be provided. 11 Operating condition Temp: 15° to 35° C. 12 Safety regulation IEC 61010 and shall comply with relevant EMC & EMI standards. 13 Software The following software shall meet the overall damped oscillatory wave and Ring wave test system requirements as per the latest IEC 61000-4-10, IEC 61000-4-18 & IEC 61000-4-12 standards. To control the test including standard library, test report facility. Windows based menu driven, user friendly interactive operation. Software shall support Windows 7 or latest operating system. Download the result data in internal/external memory. 14 Functional There shall be manual and automated test modes. Pre-defined test routines assisted with software. Soft keys or touch buttons for programming of test parameters. Page 10 of 12 15 Other Accessories Bidder shall supply PC (Latest Generation Intel i7 with 4GB 1 RAM and 500GB HD. 20” LED Monitor or better . USB Interface and Latest Microsoft office.) along with quoted Damped oscillatory and ring wave Generator. Computer software compatible with latest version of Windows. software shall be compactable with PC . Cost shall be quoted separately if not included in the cost of the main equipment. Both hard and soft copies of Safety manual, Installation manual and Operating manual shall be supplied. Cost shall be quoted separately if not included in the cost of the main equipment. All required standard accessories, interconnecting cables, power supply chord, connectors, etc., shall be supplied. Cost shall be quoted separately if not included in the cost of the main equipment. 16 Operating condition Operating Temperature: 15 deg C – 35 deg C . Operating Relative Humidity: Upto 80%. 17 Calibration Calibration Certificate shall be submitted along with Combination Wave Generator and CDNs. The calibration certificate shall be from ILAC/APLAC/NABL accredited laboratoires as per ISO/IEC 17025. Calibration certificate shall cover all parameters at specfied impedences. The calibration results shall comply with the specifications as per Standard IEC:61000-4-18,IEC: 61000-4-10 & IEC : 61000-4-12. The calibration certifiate shall be in favour of CPRI, Bangalore and date of calibratiion shall be after the date of our purchase order. Cost shall be quoted separately if not included in the cost of the main equipment. Date of calibration shall not be older than one months from the date of dispatch of the item. 18 Training Three days Training to CPRI Officers after installation and commissioning shall be provided, at CPRI, Bangalore 19 Guarantee / Warranty Minimum three years from the date of installation. Note : Compliance to meeting all of the above technical specification requirement should be furnished in detail against each serial number in GTP column with supporting technical write up, illustrations, schematics, single line diagrams, drawings, catalogues of proposed sub-equipment & instruments suppliers etc. Page 11 of 12 PN : 1. A detailed technical catalogue/literature/pamphlet and any other technical details shall be sent in hard copy in a sealed cover super scribing tender enquiry number and due date so as to reach the following address within the due date and time. This is very much essential to evaluate your offer. 2. Letter of authorization issued by the foreign Principal shall also be sent by the Indian agents. 3. The supplier shall submit the offer in the above format only with compliant statement, failing which the offer will not be considered for evaluation. Address : Joint Director (Purchase) Central Power Research Institute, Sir C.V. Raman Road, P.B.No.8066, BANGALORE-560 080. PH. No.080-23602919/23602829. Extn: 2271/2274. Fax : 080 - 2360 4446 Page 12 of 12