* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download ELECTRICAL SURVEY REPORT
Mechanical-electrical analogies wikipedia , lookup
Electric power system wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electronic engineering wikipedia , lookup
Telecommunications engineering wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Electrical engineering wikipedia , lookup
Electrician wikipedia , lookup
Electrical substation wikipedia , lookup
Power engineering wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Single-wire earth return wikipedia , lookup
Rectiverter wikipedia , lookup
Stray voltage wikipedia , lookup
Three-phase electric power wikipedia , lookup
Overhead power line wikipedia , lookup
Alternating current wikipedia , lookup
Fault tolerance wikipedia , lookup
National Electrical Code wikipedia , lookup
Mains electricity wikipedia , lookup
Electrical wiring wikipedia , lookup
Portable appliance testing wikipedia , lookup
Residual-current device wikipedia , lookup
Ground (electricity) wikipedia , lookup
ELECTRICAL SURVEY REPORT This report is the National Regulator’s preferred method for accredited marine surveyors and other qualified persons to monitor and record the electrical survey for a Domestic Commercial Vessel. It is neither mandatory nor intended for this form to be provided to the vessel owner. Vessel Details Vessel name Unique identifier Owner of vessel Builder of vessel Details and Serial number of generator(s) Details and Serial number of inverter(s) Model and Calibration date of insulation testing device Model and Calibration date of RCD testing device Model and Calibration date of earth loop testing device Is the electrical installation on board the vessel? Extra Low voltage Low voltage High voltage Combination Does the vessel have a shore power connection? No Yes If yes, how many? Visual Inspection A visual inspection of an electrical installation is to be conducted, signed, and dated to confirm that the installation is in good repair, is fit for purpose, and does not show signs of damage. This inspection does not include any electrical testing. Item Pass Fail Surveyor Comments Cables condition, no evidence of overheating, burning or tracking. Cable/wiring security. Cable penetration devices are in good order. Cables have mechanical protection for the environment in which they are installed. Socket-outlets exhibit no physical damage and there is no evidence of overheating. Light fixtures exhibit no evidence of physical damage or undue overheating or arcing. Lamps do not exceed the wattage rating of the fittings in which they are installed. AMSA563 (1/17) Page 1 of 8 Item Pass Fail Surveyor Comments LV and ELV systems are separated. Electrical equipment is adequately supported. Electrical equipment and fixed-wired appliances forming part of the electrical installation are not damaged. Operational Tests (Require systems knowledge) Item Pass Fail Surveyor Comments Pass Fail Surveyor Comments Generator operation.(5B 2.21.1) Engine Governors.(5B 2.21.1) Parallel operation.(5B 2.21.1) Load sharing.(5B 2.21.1) Voltage regulator operation by instantaneous loading and unloading of generator.(5B 2.21.1) Safety devices, such as overspeed trips, reverse power trips, over current trips, load shedding together with the associated controls and alarms.(5B 2.21.1) Overload alarm circuits of essential service motors.(5B 2.21.1) Main engine safety alarms and trips.(5B 2.21.1) Machinery and equipment that incorporates remote controls, remote stops and limit switches.(5B 2.21.1) Emergency stop circuits.(5B 2.21.1) Vessel alarm systems.(5B 2.21.1) Other systems and equipment installed in the vessels. Switchboards Item a.c. and d.c systems segregated. ( AS/NZS 3004.2.2) Switchboard and electrical equipment have no conductor insulation deterioration. RCDs, MCBs, fuses and switches show no evidence of mechanical damage. AMSA563 (1/17) Page 2 of 8 Item Pass Fail Surveyor Comments Fail Surveyor Comments Semi-enclosed rewireable fuses, where fitted, have not deteriorated due to arcing and have no exposed live parts when the fuse carrier is fitted into the fuse base. NOTE: Semi-enclosed rewireable fuses are not permitted in new installations or in alterations and additions to an existing installation.(AS/NZS 3004.2 C10) There is adequate insulation and distance between live conductors and between live conductors and earth; where the conductors are bare.(AS/NZS 3004.2 C10) Switches and protective devices are clearly labelled showing the circuit type they control or protect. (AS/NZS 3004.2 C10) For boats with an IT AC system, a continuously operating earth fault or insulation monitoring and alarm system is installed and operational.(AS/NZS 3004.2 C10) When an inverter is installed, the hazard warning label is fitted to or beside the AC. switchboard.(AS/NZS 3004.2 C10) Where there are separate earth and neutral bars, earthing conductors are connected to the earth bar and neutral conductors are connected to the neutral bar.(AS/NZS 3004.2 C10) The main earthing conductor from the boat’s earth is correctly connected at the main switchboard .(AS/NZS 3004.2 C10) The switchboard is constructed and installed in such a manner that, in the event of fire, the spread of fire will be kept to a minimum .(AS/NZS 3004.2 C10) Residual current devices (RCDs) installed for personnel protection have a residual operating current of 30 mA or less.(AS/NZS 3004.2 C10) Conductors are securely held in terminals of fittings and are not subject to tension at the terminations. (AS/NZS 3004.2 C10 and AS/NZS 3004.2 C10) Earthing and Equipment Potential Bonding Item Pass The main earthing and equipotential bonding conductor terminations are accessible. Earthing connections are mechanically sound and fixed by a secure system. AMSA563 (1/17) Page 3 of 8 Item Pass Fail Surveyor Comments Pass Fail Surveyor Comments Pass Fail Surveyor Comments Earthing and equipotential bonding connections are protected against mechanical damage, corrosion and any vibration likely to occur. Conductors of cables are correctly identified and are connected to the correct terminals of fittings. The portions of the boat earth inside the boat show no evidence of corrosion, damage or poor connection of the earthing conductor(s). Fixed Appliances Item Appliances are correctly positioned and are suitable for the environment they are located in.(AS/NZS 3004.2 C10) Covers of fixed-wired appliances are not broken or missing, giving access to live parts or basic insulation. NOTE: Connections to electrical equipment need to be enclosed and require the use of a tool to gain access.(AS/NZS 3004.2 C10) Electrical appliances are correctly mounted and protected against mechanical damage.(AS/NZS 3004.2 C10) Electrical fittings in damp areas have the correct IP rating and are appropriate for the zone.(AS/NZS 3004.2 C10) Batteries Item Batteries shall be secured against movements and inclinations occurring during boat movement.(AS/NZS 3004.2 C10) Batteries shall be covered for protection of battery and battery terminals from loose and falling objects .(AS/NZS 3004.2 C10) Batteries shall not be installed directly above or below a fuel tank or fuel filter, and any other metallic component of the fuel system within 300 mm above the battery top, as installed, shall be electrically insulated .(AS/NZS 3004.2 C10) Battery overcurrent protection complies with the standard.(AS/NZS 3004.2 C10) Battery ventilation complies with the standard (NSCV 5B 3.9) Lithium ion battery installation complies with Clause 2.9.3.of AS/NZS3004.2 AMSA563 (1/17) Page 4 of 8 Item Pass Fail Surveyor Comments Fail Surveyor Comments Batteries shall be mounted IAW chapter 3.8 of the NSCV 5B Emergency Electrical Installations must comply with Chapter 5 of the NSCV 5B Shore Power (NSCV 5B 4.7 / 3004.2 3.5.1) Item Pass Where electricity is to be supplied to a vessel from a shore supply the shipboard shore power facility shall include the following: A circuit breaker operating in all live conductors of the supply, including neutral, fitted adjacent to the shore supply inlet on the vessel. A test device, connected on the supply side of the vessel's shore supply circuit breaker to check, and visually indicate, the polarity of the shore supply in relation to the vessel's system. An interlocking circuit to ensure the shore power cannot be connected unless the polarity is correct or a polarity reversal arrangement incorporating interlocking circuitry is installed. In three phase supplies: i) a means of checking the phase sequence in relation to the vessel's system; and ii) appropriate switchgear to facilitate the reversal of phase sequence. AMSA563 (1/17) Page 5 of 8 Verification by Testing (AS/NZS 3000 / 3017 / 3004.2) AS/NZS 3000 / 3017 & 3004.2 details the requirements for testing a boat’s electrical installation to confirm that the installation remains in good repair and does not exhibit indications of misuse or damage. This testing requires the disconnection of supply to all or parts of the installation. Inspection of electrical equipment and conductors shall include the applicable checks listed below plus any additional visual checks required to verify that the installation is in a safe condition. Earth Continuity Tests Item Pass Fail Surveyor Comments/meter reading The connection between any point on the installation required to be earthed and the switchboard earth bar or terminal is continuous. For boats with an IT a.c. system, a continuously operating earth fault or insulation monitoring and alarm system is installed The main a.c. earthing conductor between the main a.c. switchboard and the boat electrical earth is continuous and the resistance of the main earthing conductor does not exceed 0.5 Ω. The connection between any point on the installation required to be equipotentially bonded and the switchboard earth bar is continuous. The connection between any point on the installation required to be equipotentially bonded and the switchboard earth bar is continuous. The resistance of each equipotential bonding conductor does not exceed 0.5 Ω. There is a MEN connection between neutral and earth at each source of supply or where supplies operate in parallel at the main switchboard. NOTE: In this instance shore power must be isolated from the vessel system by an isolating transformer or converter Fixed wired appliances requiring earthing (Class I) are connected to earth. With the boat connected to shore power an earth fault loop impedance test shall be carried out from each a.c. outlet on the boat to confirm that the earth loop impedance in ohms meets the requirements of AS/NZS 3000 NOTE: For boats fitted with a galvanic isolator(s) this will also test the operation of the galvanic isolator(s). AMSA563 (1/17) Page 6 of 8 Polarity and Correct Connections (NSCV 5B and AS/NZS 3004.2) Item Pass Fail Surveyor Comments/meter reading In a multiphase circuit a switch, or circuitbreaker when used as an isolator, operates simultaneously in all active conductors of the circuit in which it is connected. Neutral conductors of circuits are connected to the neutral bar of the switchboard from which the circuit is supplied. The incoming main neutral is connected to the neutral bar of the main switchboard. Every RCD operates in the live conductors (active and neutral) of the circuit(s) to which it is connected. Single phase socket-outlets that accommodate flat-pin plugs are connected so that, when viewed from the front of the socket-outlet, earth, active and neutral are connected in a clockwise order and the earth is connected to the slot on the radial line. Where multiphase socket-outlets of the same type form part of an electrical installation the phase sequence of the socket-outlets shall be the same. The polarity of the supply lead and appliance inlet is correct. RCD and Insulation Testing (RCD trip time and current to be recorded) Item Pass Fail Surveyor Comments/meter reading Pass Fail Surveyor Comments/meter reading The correct operation of RCDs shall be verified by the use of special test equipment. Tests shall be performed on each final sub circuit protected by an RCD to verify that the RCD operates to disconnect the designated circuit. An insulation resistance test shall be carried out with test instruments to ensure, so far as practicable, that there is adequate insulation between live parts and earth and between LV and ELV systems a.c. Electrical Power Sources Item Confirm transfer from one nonsynchronized a.c. power source circuit to another is made by a means which opens all current-carrying conductors before closing the other source circuit and is interlocked by mechanical or electromechanical means. AMSA563 (1/17) Page 7 of 8 Item Pass Fail Surveyor Comments/meter reading Pass Fail Surveyor Comments/meter reading Verify by function testing to confirm synchronized a.c. power sources are provided with the following: Under/over voltage protection. Under/over frequency protection. Reverse power protection – generators. Backfeed protection – inverters. Confirm that the point at which neutral conductor of an AC. system is earthed either at: (a) at the source of power, e.g. at the onboard generator, the secondary of the transformer or the output of an inverter or a converter; or (b) by a removable link between the vessel main neutral and the main a.c. earth bus bars. NOTE: Option (b) is only possible when shore power connects to the vessel via a transformer or converter with isolation between the input and output. Confirm switchboard electrical instruments are indicating values within ±5% of the values indicated by the test instruments. Additional tests carried out Item AMSA563 (1/17) Page 8 of 8