Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Misure di compatibilita’ Elettromagnetica Roberto Sacchi Electronic Measurements Group Agilent Technologies EMC seminar Page 1 Agenda Introduzione alle misure EMI Terminologia; Sistema di misura (antenna, LISN, ricevitore, etc.); Detectors; Normative europee ed internazionali Misure di compatibilita’ elettromagnetica Misure di emissioni radiate Misure di emissioni condotte Misure di immunita’ (EMS) Setup di misura Camere anecoiche vs. OATS (Open Area Test Site) Soluzioni Agilent Introduzione al nuovo ricevitore EMI Full Compliance Agilent MXE Uso degli analizzatori Agilent della Serie-X per misure EMI pre-compliance. Sorgenti per i test di immunita’ Software applicativo Soluzioni complete tramite i nostri partners EMC seminar Page 2 Pre-compliance vs. Full compliance measurements Pre-compliance measurements Evaluate the conducted and radiated emissions of a device using correct detectors and bandwidths before going to a test house for compliance testing Full Compliance measurements Full compliance testing requires a receiver that meets all the requirements of CISPR 16-1-1 (response to a CISPR pulse gen), a qualified open area test site or semi anechoic chamber and an antenna tower and turntable to maximize EUT signals. EMC seminar Page 3 What is EMC? Electromagnetic Compatibility (EMC): The ability of equipment to function satisfactorily in its electromagnetic environment without introducing intolerable disturbances into that environment or into other equipment. Combination of Interference and Immunity. Electromagnetic Interference (EMI): Electromagnetic energy emanating from one device which causes another device to have degraded performance. Electromagnetic Immunity (Susceptibility, EMS): Tolerance in the presence of electromagnetic energy (Performance degradation due to electromagnetic energy). Compliance measurements require a receiver that meets the requirements of CISPR part 16 (for commercial) or MIL-STD-461 (for military). All EMI receivers require a pre-selector at lower frequencies to limit the input energy and maintain sufficient dynamic range to meet the CISPR 16 requirements. EMC seminar Definitions EMC – ElectroMagnetic Compatibility EMI – ElectroMagnetic Interference EMS – ElectroMagnetic Susceptibility (aka Immunity) EMC seminar EMI measurement system EMC seminar Page 6 Compliance EMI receiver requirements A CISPR 16-1-1 receiver must have the following functionality in the range 9 kHz - 18 GHz: A normal +/- 2 dB absolute accuracy CISPR-specified resolution bandwidths (-6 dB) Peak, quasi-peak, EMI average, and RMS average detectors Specified input impedance with a nominal value of 50 ohms; deviations specified as VSWR Be able to pass product immunity in a 3 V/m field Be able to pass the CISPR pulse test (implies pre-selector below 1 GHz) Other specific harmonic and intermodulation requirements EMC seminar Page 7 Receiver requirements above 1 GHz Above 1 GHz regulations require: 1 MHz bandwidth for measurements No quasi-peak detector No CISPR pulse test, meaning no additional pre-selector required excellent sensitivity According to current FCC regulations, the maximum test frequency is the fifth harmonic of the highest clock frequency for an “unintentional radiator” (for example, computers without wireless connectivity) and the tenth harmonic for an intentional radiator (such as a cellular phone or wireless LAN). EMC seminar Page 8 What is an EMI Receiver? Let’s begin with a spectrum analyzer Spectrum Analysis •Display and measure amplitude versus frequency for RF & MW signals •Separate or demodulate complex signals into their base components (sine waves) EMC seminar Page 9 Overview Types of Tests Made Modulation EMC Noise Distortion EMC seminar Page 10 Architecture of Modern Spectrum/Signal Analyzers What does “Modern” mean? Digitize the IF output, not detector output FFT and swept capability (neither one is optimum for everything) Complete spectrum analyzer & vector signal analyzer Data output available Connectivity Automated measurement features Ability to use new features and duplicate or expand necessary old ones EMC seminar 11 Theory of Operation Swept Spectrum Analyzer Block Diagram RF input attenuator mixer IF gain IF filter (RBW) Input signal envelope detector Log Amp Pre-Selector Or Low Pass Input Filter local oscillator video filter sweep generator Crystal Reference Oscillator ADC, Display & Video Processing EMC seminar Page 12 Traditional Spectrum Analyzer Scalar analysis Digitizing the video signal Product detector loss of phase information Classic superheterodyne swept spectrum analyzer EMC seminar 13 Digital IF Spectrum/Signal Analyzer Vector data CAN be preserved (mag/phase or I/Q) Digitizing the IF Signal Some troublesome operations and conversions are now fast, accurate DSP EMC seminar 14 Overview Different Types of Analyzers FFT Analyzer A Swept Analyzer Parallel filters measured simultaneously f1 f2 A f Filter 'sweeps' over range of interest f1 f2 f EMC seminar Page 15 Specifications Resolution: RBW Type Determines Sweep Time 8563E Analog RBW PSA Digital RBW PSA FFT RBW 280 sec 134 sec 13.5 sec EMC seminar Speed Improvements Nominal speed comparison, PSA example: Benchmark PXA PSA Speed improvement Preset (*RST) Marker peak search Local Update CF Tune and Transfer (4 - 5GHz) Remote sweep and trace transfer 28 ms 6.5 ms 13 ms 109 ms 18 ms 168 ms 78 ms 17 ms 186 ms 30 ms 6x 12x 1.3x 1.7x 1.67x Useful comparisons highly specific, many factors PXA mode switching typically faster than PSA Where speed is critical, consider modifying measurement routines to include features such as list sweep EMC seminar 17 Modern spectrum analyzer Resolution BW Selectivity or Shape Factor 3 dB 3 dB BW 60 dB 60 dB BW Selectivity = 60 dB BW 3 dB BW Determines resolvability of unequal amplitude signals EMC seminar Page 18 Specifications Resolution: RBW Type and Selectivity ANALOG FILTER Typical Selectivity Analog 15:1 Digital ≤5:1 DIGITAL FILTER RES BW 100 Hz SPAN 3 kHz EMC seminar Page 19 Digital Filter Shape Better shape factor, biggest selectivity benefit for different signal levels Equivalent selectivity at a wider, faster-sweeping RBW digital filters swept an additional 3-4x faster 30 kHz Digital Filter EMC seminar 20 CISPR Bandwidth Requirements Bandwidth -6dB -20dB Measurement Range CISPR Band CISPR Bandwidth 9 KHz – 150KHz A 200 Hz 150 KHz – 30 MHz B 9 KHz 30 MHz – 1 GHz C/D 120 KHz > 1GHz E 1 MHz EMC seminar Page 21 MIL-STD-461 Bandwidth Requirements Measurement Range -6dB Bandwidth 30Hz - 1 KHz 10 Hz 1 KHz -10 KHz 100 Hz 10 KHz - 150 KHz 1 KHz 150 KHz - 30MHz 10 KHz 30 MHz - GHz 100 KHz > 1GHz 1 MHz EMC seminar Page 22 Modern Spectrum Analyzer Accuracy Some modern analyzers approach accuracy of power meter + sensor • Even better for low-level signals, with narrower noise bandwidth and the benefit of frequency selectivity Some factors determining uncertainty: • Input connector (mismatch) • RF input attenuator • Mixer and input filter (flatness) • IF gain/attenuation (reference level) • RBW filters • Display scale fidelity • Calibrator EMC seminar 23 Modern Spectrum Analyzer Accuracy Examples EMC seminar 24 Line Impedance Stabilization Networks (LISN) Purpose of a LISN: 1. Isolates the power mains from the equipment under test. The power supplied to the EUT must be as clean as possible. Any noise on the line will be coupled to the X-Series signal analyzer and interpreted as noise generated by the EUT. 2. Isolates any noise generated by the EUT from being coupled to the power mains. Excess noise on the power mains can cause interference with the proper operation of other devices on the line. 3. The signals generated by the EUT are coupled to the X-Series analyzer using a high-pass filter, which is part of the LISN. Signals that are in the pass band of the high-pass filter see a 50-Ω load. EMC seminar Page 25 LISN EMC seminar Page 26 LISN @ Electrical Network Frequency @ 150 kHz to 30 MHz EMC seminar Page 27 Transient Limiter The purpose of the limiter is to protect the input of the EMC analyzer from large transients when connected to a LISN. Switching EUT power on or off can cause large spikes generated in the LISN. Limiter LISN DUT The Agilent 11947A transient limiter incorporates a limiter, high-pass filter, and an attenuator. It can withstand 10 kW for 10 μsec and has a frequency range of 9 kHz to 200 MHz. The high-pass filter reduces the line frequencies coupled to the EMC analyzer. EMC seminar Page 28 Field Strength Unit Radiated EMI emissions measurements measure the electric field. The field strength is calibrated in dBμV/m. Pt = total power radiated from an isotropic radiator Pd = the power density at a distance from the isotropic radiator (far field >λ/2π) Pt Pd 4 r 2 R 120 E2 Pd R Pt E2 R 4 r 2 [ohm] E Pt 30 r [V/m] EMC seminar Page 29 Field Strength and Antenna factors Radiated EMI emissions tests measure the electric field. The field strength is calibrated in dBμV/m. Antenna factors is the ratio of the electric field (V/m) present at the plane of the antenna versus the voltage out of the antenna connector. Log units: AF(dB/m) = E(dBμV/m) - V(dBμV) E(dBμV/m) = V(dBμV) + AF(dB/m) Notes: Antenna factors are not the same as antenna gain. dBμV = dBm + 107 EMC seminar Page 30 Antennas used in EMI emission measurements EMC seminar Page 31 Detectors: Convert IF Samples to Display Bins or “Buckets” Multiple simultaneous detectors Peak, Neg Peak, Sample Normal, Average, Neg Peak Display points or buckets Peak Volts Sample Neg Peak Screen Shot “Detector 3types” Time EMC seminar 32 Detectors Most radiated and conducted limits are based on quasi-peak detection mode. EMC seminar Page 33 Peak vs. Quasi-peak vs. Average V Peak Detection Quasi-Peak Detection Average Detection time V Peak Detection time Quasi-Peak Detection Average Detection EMC seminar Page 34 Peak ≧ QP ≧Average Peak Detector • Initially used • Faster than QP and Average modes • If all signals fall below the limit, then the product passes and no future testing is needed. QP • For CW signal, Peak = QP • Much slower by 2 or 3 order magnitude compared to using Peak detector • Charge rate much faster than discharge rate – the higher repetition rate of the signal, the higher QP reading Average • Radiated emissions measurements above 1 GHz are performed using average detection EMC seminar Page 35 Close field probe Measures the magnetic field H strength at the center of its sense loop. The plane of the probe tip loops must be perpendicular to the radiating magnetic field EMC seminar Page 36 Test example EMC seminar Page 37 International emissions regulations (summary) EMC seminar Page 38 CISPR changes… RMS-Average Preselector-less testing: enables use of spectrum analyzer for specific test cases.(no emissions with PRF < 20 Hz) CISPR 22 to 6 GHz Time Domain: sometimes required for the automotive market APD: soon to be required by CISPR11 EMC seminar Page 39 European Norms example EN55014 (CISPR 14) This standard applies to electric motor-operated and thermal appliances for household and similar purposes, electric tools and electric apparatus. Limit line use depends upon the power rating of the item. EN55014 distinguishes between household appliances, motors less than 700W, less than 1000W and greater than 1000W. Limits for conducted emissions are 150 kHz to 30 MHz, and limits for radiated emissions are 30 MHz to 300 MHz. EMC seminar Page 40 The compliance measurement process Before making measurements on your product, some preliminary questions must be answered. 1. Where will the product be sold (for example, Europe, United States, Japan)? 2. What is the classification of the product? a. b. c. d. Information technology equipment (ITE) Industrial, scientific or medical equipment (ISM) Automotive or communication Generic (equipment not found in other standards) 3. Where will the product be used (for example home, commercial, light industry or heavy industry)? With the answers to these questions, you can determine which standard your product must be tested against. EMC seminar Page 41 General Process for Making EMI Measurements Determine the country or countries in which the product will be sold which in turn identifies the regulator agency. Select the limit lines to be tested to (conducted/radiated). Select the band to be used. Correct for transducer loses and amplifiers gains. Identify signals above the limit that must be evaluated. Zoom in on failed signal and perform quasi-peak or average measurements. EMC seminar Page 42 Conducted Emissions Measurements 1. Connect DUT to the test system 2. Set the proper frequency range 3. Load limit lines and correction factors for LISN and limiter 4. View the ambient emissions with DUT OFF 5. Switch on the DUT and find signals above limits by using peak detector 6. Measure all signals above limits with quasi-peak and average detectors EMC seminar Page 43 EMC seminar Page 44 The challenge of measuring radiated emissions Radiated Emissions are difficult to measure because of multiple dimensions (five) and the use of quasi-peak detection below 1GHz 5 -Time 1 - Azimuth 2 - Antenna Height 3 - Field Strength 1500.260MHz 218.120MHz 4 - Frequency 41.2563MHz Radiated Emissions Measurements 1. Connect the antenna to the EMI receiver and separate the antenna from the DUT as specified by the regulation requirements 2. Set the proper frequency range and bandwidth 3. Load limit lines and correction factors for antenna and cable. 4. With DUT OFF, measure the ambient emissions and store them 5. Switch on the DUT and find signals above limits by using peak detector (only those not present during the ambient scan). Rotate the DUT to maximize the emissions. 6. Measure all signals above limits with quasi-peak and average detectors EMC seminar Page 46 Open Area Test Site (OATS) EUTs are measured in an open area test site (OATS) or anechoic chamber. ANSI C63.4 and CISPR 16-1-1 specify the requirements for an OATS, including: Preferred measurement distances of 3, 10, and 30 meters Antenna positioning at 1 to 4 meter Heights An area called the “CISPR ellipse” of major diameter 2X and minor diameter √3 • X, where X is the measurement distance; the ellipse must be free of any reflecting objects A metal ground plane for the measurement area Note: 10 meter anechoic chambers and GTEM cells can also be used for radiated compliance measurements. EMC seminar Page 47 1. Select the measurement range EMC seminar Page 48 2. Load Corrections factors Amplitude at point circled Amplitude referenced to blue line EMC seminar Page 49 3. Load Limit line Circle indicates the position of the amplitude frequency pair EMC seminar Page 50 4. Scan for signals above the limits with peak detector EMC seminar Page 51 5. Quasi-peak and average measurements EMC seminar Page 52 Troubleshooting Use the close-field probe to locate the sources of the radiated signals exceeding the limit lines EMC seminar Page 53 Immunity test setup Radiated Immunity 30 MHz – 18 GHz Amplifiers HF-Switch Conducted Immunity 100 kHz – 1 GHz EMC seminar Agilent Solutions EMC seminar Page 55 What is a CISPR 16-1-1 Compliant Receiver CISPR is a subcommittee of the IEC CISPR 16-1-1 is the document that defines the functionality of an EMI receiver Detectors Frequency response N9038A MXE EMI receiver is CISPR 16-1-1 2010 Compliant EMC seminar What is the MXE EMI Receiver? The Agilent MXE is more than a CISPR 16-1-1 compliant EMI receiver It is also an X-Series signal analyzer that can run a variety of measurement applications The MXE can evolve as technology changes X-Series signal analyzer CISPR 16 compliant EMI receiver EMC seminar N9038A MXE EMI Receiver in 30 seconds Compliant Preselection 20 Hz to 3.6 GHz in both EMI Receiver Mode and SA Mode on Both Inputs CISPR 16-1-1 2010 Compliant EMI Receiver 20 Hz to 1 GHz for Conducted Emissions (built-in limiter) Run X-Series applications 20 Hz to 26.5 GHz for Radiated Emissions LB 20 Hz -1GHz CFB INB DDS RFB Noise Source EMC seminar Agilent X-Series Signal Analyzers Multiple instruments in one box: Swept spectrum analyzer; FFT analyzer; RF and Baseband Vector Signal analyzer; Noise Figure analyzer. Fastest signal analysis measurements Broadest set of applications and demodulation capabilities Upgradeable HW Most advanced user interface & world-class connectivity EMC seminar Instrument Architecture Modern Spectrum Analyzers Architecture (PSA, X-Series) RF Section •Attenuation •Filtering •Downconversion ADC IF Section BB Section IF/BB Section on ASIC • RBW Filtering • Envelope Detection • Log Conversion • VBW Filtering • Peak/sample/rms detection • Averaging “All Digital” IF Architecture Modern Spectrum Analyzer Block Diagram Analog IF Filter Pre-amp Digital IF Filter Digital Detectors FFT Attenuation Swept vs. FFT YIG Digital Log Amp AD C Replaced by EMC seminar “All Digital IF” Advantages RF Section ADC FFT IF/BB Section on ASIC Flexibility: RBW filtering in 10% steps Filters with better selectivity Multiple operation modes (Swept, FFT, VSA, NFA) Accuracy: Log conversion practically ideal No drift errors; increased repeatability Speed: When Swept mode is slow, go FFT Techniques for Reducing DANL, Improving Dynamic Range Reduce attenuation Add preamp Reduce RBW Add external filtering Better/shorter cables, connectors Move analyzer closer Time averaging (where possible, not measurement avg.) Measurement processing (take advantage of Moore’s Law) • Noise power subtraction/noise correction/NNC • Noise floor extension (NFE) leverages deep knowledge of analyzer/circuit behavior EMC seminar 64 CW Signal Measured Near Analyzer Noise Floor Example: No noise subtraction or near noise correction Apparent Signal Displayed S/N Actual S/N CW Signal Ampl & Freq Axes Expanded This is fundamental, and often missed EMC seminar 65 Noise Floor Subtraction PobsS+N = PobsN + PS PS = PobsS+N − PobsN Analyzer noise adds incoherently to any signal to be measured Power calculations are performed on a linear power scale (watts, not dBm) and results typically are shown in dBm EMC seminar 66 Noise Subtraction, “Noise Floor Extension” New technique “NFE” improves D.A.N.L. analyzer noise power calculated/subtracted real time “No” error 3 dB error without NFE Improved noise floor or displayed average noise level EMC seminar 67 Analyzer Noise Floor with NFE Source still off, green trace shows analyzer noise level with NFE Other measurement conditions unchanged Note high variance result from subtraction of small, noisy numbers Analyzer DANL now far enough below source for minimal (0.2 - 0.4 dB) error EMC seminar 68 A Closer Look Source noise Level, no NFE Source Noise Level, with NFE Analyzer Noise, no NFE Analyzer Noise with NFE Pink trace adds to blue trace; result is yellow trace (NFE not used) Green trace is included in blue trace but resulting error very small EMC seminar 69 EMC Features standard in all X-Series Spectrum analyzers • Limit Lines (2000 pts) • Amplitude correction (2000 pts) • 40001 sweep points EMI Roadmap Page 70 6/28/2011 Option EMC in X-Series spectrum analyzer CISPR 16-1-1 detectors (to latest spec) Quasi Peak EMI Average (“CISPR-AVG”) RMS Average (“CISPR-RMS”) EMI Bandwidths (CISPR & MIL STD) EMI Presets Tune & Listen Measure at Marker EMI Peak, EMI Average, and Quasi Peak measurements displayed together Page 71 W/N6141A EMC measurement application Full Featured Pre-compliance Application Available in all X-Series models EMC seminar Page 72 Log Display Auto-detect peaks Peak List Page 75 Realtime Meters with any 3 Simultaneous Detectors Limit Delta N6141A measurement: Frequency Scan with Log Display - same functionality as E7400 Signal List Meters tune to selected signal EMC seminar Page 76 N6141A measurement: Strip Chart • Time record of zero span data scrolls to left • Up to three different detectors • Can be used to make “click” measurements Patent Applied For Click measurements are made on home appliances EMI Roadmap Page 77 6/28/2011 Option EDP (Enhanced Display Package) for the SA • Spectrogram • Trace Zoom • Zone Span Group/Presentation Title EMC seminar Agilent Restricted Page 78 N6141A EMI Measurement Application PXA MXA Pre-compliance EXA CXA Compliance Agilent MXE N9038A EMC seminar Agilent products for Immunity test (EMS) Signal generator 9 kHz – 3 GHz, AM, FM, Phase, Pulse IQ Modulator, 40 MHz Mod.-BW Signal generator N5182, N5182, N5183 100 kHz- 1,3, 6, 20, 40 GHz, AM, FM, Phase, Pulse, optional vector, 120 MHz Mod.-BW, step , sweep, USB-Power meter included Power meter/ Power sensors E441x, E191x, N8262, U200x 100 kHz – 40 GHz single channel, dual channel, USB, peak, envelope, pulse Accessories Directional Couplers, cables, Adapters, Switches etc. EMC seminar Solution partners for EMC Complete solution: 1. Automation software 2. Chambers 3. GTEM 4. Antennas 5. Power amplifiers 6. Accessories EMC seminar Page 81 Per documentazione su prodotti ed applicazioni EMI/EMC visitare il sito http://www.agilent.com/find/EMC Contatti: Agilent Technologies Italia Roberto Sacchi Application Engineer E-mail: [email protected] Giuseppe Savoia Signal Analysis and Generation Sales Specialist E-mail: [email protected] Agilent Contact Center E-mail: [email protected] Tel: 02 9260 8484 EMC seminar