LED Luminaire Installation for Magnetic Resonance Imaging Suites (MRI) Magnetic Resonance Imaging (MRI) machines generate strong magnetic fields to create images which aid in medical diagnoses. Objects and equipment inside the MRI suite must be non-ferromagnetic and the electrical wiring entering must be filtered so as not to interfere with the medical imaging. The light source operating inside the room must not produce interference. In the past, dimmable tungsten halogen lamps on direct current have been used but they were inefficient and had a very short life. Today, LED luminaires with remote constant current drivers are ideal for MRI applications since they are energy efficient, have a very long useful life and are dimmable. The Lighting Quotient offers several LED luminaires specifically designed for MRI suites with non-ferromagnetic components and remote drivers mounted outside of the shielded room. Each driver’s output must be filtered upon entry into the shielded MRI suite. Since MRI filters can be expensive it is recommended to contact The Lighting Quotient prior to specification as it may be possible to reduce the number of drivers and MRI filters required (depending upon the layout and type of luminaires). The Lighting Quotient offers accessory MRI room filters (AMR02050) to individually filter the output of each remote LED driver entering the shielded area of the MRI suite. AMR02050 Specifications Maximum Rated 250V Case Material Plated Steel Voltage Rated Current 2 wires @ 5A Operating -25°C to 85°C (amps) Temperature Overload 7.5A for 10 Output wires (load UL1015 minutes side) Hi-pot Rating Per UL 1283 Attenuation >100dB (5MHz to 10GHz) Voltage Drop at <1% IEC Climatic category 25/85/21 rated current AMR02050 filters provide 100 decibels of attenuation on the driver output lines from 5MHz to 10GHz up to 5 amps of current. Specifier shall confirm performance complies with filter requirements of the specific MRI equipment used.