Download 16-16-FL - EsaSafe

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Mechanical filter wikipedia , lookup

Aluminium-conductor steel-reinforced cable wikipedia , lookup

Alternating current wikipedia , lookup

Electromagnetic compatibility wikipedia , lookup

Mechanical-electrical analogies wikipedia , lookup

Vacuum tube wikipedia , lookup

Flexible electronics wikipedia , lookup

Electronic engineering wikipedia , lookup

Triode wikipedia , lookup

Stray voltage wikipedia , lookup

Video camera tube wikipedia , lookup

Tube sound wikipedia , lookup

Electrical connector wikipedia , lookup

Electrical engineering wikipedia , lookup

Mains electricity wikipedia , lookup

Ground loop (electricity) wikipedia , lookup

Portable appliance testing wikipedia , lookup

Ground (electricity) wikipedia , lookup

Tube socket wikipedia , lookup

Earthing system wikipedia , lookup

Electrician wikipedia , lookup

Home wiring wikipedia , lookup

Electrical wiring wikipedia , lookup

National Electrical Code wikipedia , lookup

Electrical wiring in the United Kingdom wikipedia , lookup

Transcript
16-16-FL
FLASH
October 2016
Supersedes 09-09-FL
Knob and tube wiring in residential installations
Issues with knob and tube wiring
Since January 2003, the Electrical Safety Authority (ESA) has received an increasing number of questions
about the safety of knob and tube wiring. In particular, purchasers or owners of older homes are finding that
many insurers will not provide or renew coverage on such properties. In some cases, the insurance companies
are requiring a total replacement of this wiring prior to providing insurance coverage.
Knob and tube wiring, more recently referred to as open wiring, was a wiring method used in the early 1900s to
1940s in the residential sector. Over the years wiring installation practices have changed in the residential
sector and knob and tube wiring is no longer installed, however, parts continue to be available for maintenance
purposes.
Diagram F1- Typical knob and tube installation
Existing knob and tube conductors concealed in walls, floor spaces, etc; supplying general lighting and
receptacle circuits are permitted to remain in place if:
• They are protected by a 15 A fuse or circuit breaker; and
• No additional outlets have been added to the original installation, so as to overload the circuit; and
• The conductors, where visible, appear to be in good condition.
If your home has knob and tube wiring, we recommend that you follow these guidelines:
• Have a licensed electrical contractor check the “knob and tube” conductors in your existing installations for
signs of deterioration and damage; or request a general inspection from ESA. The General Inspection report
will identify visible electrical safety concerns in your electrical wiring.
• “Knob & tube” conductors should be replaced where exposed conductors show evidence of mechanical
abuse and/ or deterioration, poor connections, overheating, or alterations that result in overloading, or if
changes to the wiring contravene any section of the Ontario Electrical Safety Code (OESC).
Page 1 of 3
FLASH
16-16-FL
Homes with knob and tube wiring may not have the electrical capacity to meet today’s needs. As a result,
homeowners have modified their electrical system with what ESA classifies as unsafe practices:
• Improper use of extension cords – using improperly rated extension cords, or using extension cords as
permanent wiring;
• Improper fuse replacement – using 20 or 30 A fuses to replace15 A;
• Improper connections - adding receptacles and outlets on existing circuits or improperly connecting to the
knob and tube wiring (this work should be done by a licensed electrician);
• Removing ground pins – ground pins on power bars or electrical equipment should not be removed to
accommodate the two pin receptacles used in knob and tube wiring (2 pin to 3 pin are not permitted)
• Improper replacement of two pin receptacles. If you require a three prong receptacle, only use a ground
fault circuit interrupter (GFCI) receptacle.
Homeowners who are planning to modify their knob and tube wiring, or any other electrical wiring, should have
the work performed by a licensed electrical contractor or electrician and arrange for an electrical inspection by
ESA.
Receptacles in existing knob and tube installations
Where grounding type receptacles (three pin) are installed in existing knob and tube installations to replace the
ungrounded type (two pin) receptacles, special caution must be exercised.
Diagram F2-Two and three pin receptacle configuration
Two Pin (ungrounded) Three Pin (Grounded)
Rule 26-700(7) requires the installation of a bond conductor, to bond the receptacle to ground. This is permitted
to be an external bonding conductor that is connected to either the system ground conductor or a metallic cold
water pipe that is bonded to ground. This method may be difficult to accomplish.
As an alternative to bonding, Rule 26-700(8) of the Code also states that "grounding type receptacles without a
bonding conductor shall be permitted to be installed, provided each receptacle is protected by a GFCI of the
Class A type, that is an integral part of this receptacle; or supplied from a receptacle containing a GFCI of the
Class A type; or supplied from a circuit protected by a GFCI of the Class A type (a GFCI breaker in the panel, or
either a GFCI receptacle or a GFCI dead front mounted in an outlet box next to the panel). Where this option is
used, no bonding conductor is permitted between outlets, unless that conductor is in turn connected to ground.
GFCI protection of the receptacles does not provide a ground reference to the U-ground slot of the receptacles.
Some appliances require a bond be connected to the U-ground slot in order to function properly. For example,
surge protective devices for computer or entertainment equipment will not function without a ground reference.
As new electrical equipment is introduced into the dwelling unit there might be a need for additional outlets to be
installed. Extension cords are not to be used as a substitute for permanent wiring. The following shall be
followed when installing new receptacles:
• Outdoor receptacles shall be GFCI protected,
• Bathroom and washroom receptacles shall be GFCI protected.
• Kitchen receptacles within 1 m of a sink shall be GFCI protected
• New outlets shall follow the current OESC requirements for wiring, meaning a new branch circuit shall be
grounded and receptacles that utilize the three pin grounded configuration, listed in Diagram F2.
Page 2 of 3
FLASH
16-16-FL
Benefits of new wiring
While knob and tube conductors in good condition that have not been inappropriately altered will not present
undue hazards, it is worth noting that modern electrical installations contain safety benefits not found in older
electrical systems. These include:
• Generally larger electrical capacity and more electrical circuits reducing the need to use extension cords
• Splices and joints made in approved electrical boxes
• Dedicated electrical circuits for certain types of electrical equipment or appliances
• Grounded and bonded receptacles, switches and light fixtures
• Tamper resistant receptacles in homes
• Ground fault circuit interrupters in bathrooms and outdoor locations as per the latest edition of the OESC
• Arc Fault Circuit Interrupters in bedroom receptacle circuits
• GFCIs near sinks.
Homeowners who are planning to modify their knob and tube wiring, or any other electrical wiring, should have
the work performed by a licensed electrical contractor or electrician and arrange for an electrical inspection by
ESA.
Myths
• Knob & Tube wiring is unsafe.
• All knob and tube wiring must be disconnected and replaced.
• The OESC no longer recognizes knob and tube wiring as an acceptable wiring method.
Facts
• Knob & Tube wiring is safe, provided it is properly maintained by competent licensed people as outlined
above.
• The ESA as well as the OESC recognize and accept knob and tube wiring methods.
• The OESC contains rules that govern the installation of open type wiring methods (knob & tube).
Rules 12-202 to 12-224 set out the minimum safety standards for the installation of open wiring, which may
still be installed to this day.