Rotameter Process condition details S. No. Tag Description Range Fluid Operating Operating Temp. temp. Pressure range 80 kg/hr 12V2 to 17T3 gas Syn gas + to 800 -10°C flow NH3 kg/hr 1 17 FIT 105 2 17 FIT 128 Reflex to 17C4 3 17 FIT 120 KNH2 to 17T3 ANNEXURE-A Design Design Temp Pressure Density at operating condition Viscosity at operating condition Material of construction Process Connection 132 kg/cm2 -20 to + 50° C 50°C 160Kg/cm² 0.048 kg/ltr 0.0176 cps i) Body SS 316 iii)Internal 1/2" RF flange ii) Flange (without s (float) SS 316 SS 316L serration) 1500# 2.6 kg/hr Liquid to 26 40°C ammonia kg/hr 139 kg/cm2 -20 to + 50° C 50°C 160Kg/cm² 0.134 cps i) Body SS 316 iii)Internal 1/2" RF flange ii) Flange (without s (float) SS 316 SS 316L serration) 1500# 1 kg/hr to 10 kg/hr 132 kg/cm2 -20 to + 50° C 50°C 160Kg/cm² 0.730 kg/ltr 0.2 cps i) Body SS 316 iii)Internal 1/2" RF flange ii) Flange (without s (float) SS 316 SS 316L serration) 1500# Liquid ammonia + KNH2 30°C 0.60 kg/ltr