Download Screw-in Immersion Heater Design Drawing Description Features

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Switched-mode power supply wikipedia , lookup

Stray voltage wikipedia , lookup

Alternating current wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Opto-isolator wikipedia , lookup

Vacuum tube wikipedia , lookup

Second Industrial Revolution wikipedia , lookup

Tektronix analog oscilloscopes wikipedia , lookup

Thermal runaway wikipedia , lookup

Tube socket wikipedia , lookup

Phone connector (audio) wikipedia , lookup

Triode wikipedia , lookup

Voltage optimisation wikipedia , lookup

Thermostat wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
INDUSTRIAL THERMAL MANAGEMENT
Screw-in Immersion Heater
Standard sizes for application in water
Power (W)
2000
3000
4500
6000
7500
Input Voltage (V)
230
400
230
400
230
400
230
400
230
400
Immersion Length (mm)
190
250
375
475
600
3
3
3
3
3
Number of Tubes
Features
Heating elements for direct heating
of liquids, viscous substances, gases
U-bend tubular heaters that are directly immersed in the
substance to be heated. Heating elements are joined to
a srew plug or to a blind flange thus forming a self-contained
heating unit that can be furnished with enclosure and
control device if desired.
Design
Characteristics
Screw plug made of brass, St37.2 or stainless steel
Thread G 1 1/4", G 1 1/2", G 2"
2 - 6 tubes depending on thread of screw plug
Blind flanges IAW DIN 2527 form B,
Sizes B50, B65, B80, B100, B170, B175, B200, B250
Material St37.2 stainless steel on request
Number of tubular elements according to application
Capillary thermocouple optional,
temperature ranges 0 - 85°C, 30 - 110°C, 50 - 300°C
With enclosure, Ø 80 x 97, IP 65,
with temperature limiter 110°C or 135°C inside
Operating voltage 230V, 230/400V
Special voltages up to 500V
Installation with gasket in threaded bore or with companion
nut, for flat flange with matching companion flange
Note that immersion heaters should not be operated under
dry conditions
Applications
Boilers, heating of vessels, containers and tanks, oil tubes,
oil sump of engines, hydraulic equipment, deep fat fryers,
fat containers, washing machines, steam generators,
laboratory equipment, medical apparatuses, instantaneous
water heaters
G 1 1/2”
G 1 1/4”
Design Drawing
Protection class I DIN EN 60335-1
This
DBK 231012.
information is subject to change without notice. Data is given for illustration purposes only and does not release the customer from independent application tests.
Description
For further information or locating a sales office near you, please visit our website at www.dbk-group.com.