Download Solid State Timers and Controllers Solid State DC Flasher

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Standing wave ratio wikipedia , lookup

Amplifier wikipedia , lookup

TRIAC wikipedia , lookup

Analog-to-digital converter wikipedia , lookup

Transistor–transistor logic wikipedia , lookup

Multimeter wikipedia , lookup

Josephson voltage standard wikipedia , lookup

Ohm's law wikipedia , lookup

Integrating ADC wikipedia , lookup

Valve RF amplifier wikipedia , lookup

CMOS wikipedia , lookup

Operational amplifier wikipedia , lookup

Current source wikipedia , lookup

Power MOSFET wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Schmitt trigger wikipedia , lookup

Power electronics wikipedia , lookup

Surge protector wikipedia , lookup

Current mirror wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Voltage regulator wikipedia , lookup

Opto-isolator wikipedia , lookup

Rectiverter wikipedia , lookup

Transcript
Solid State Timers and Controllers
Solid State
DC Flasher
423
Unlike most solid state devices that switch the low or ground side of the DC
operating voltage, the model 423 switches the high side of the DC operating
voltage to an external load circuit when switched "ON." The flash rate can be
specified over a wide range from 1 flash per minute to 600,000 flashes per
minute. The duty cycle of the flashing rate is 50%. Load currents to 1 ampere
may be driven with the output of the model 423. The model 423 has internal
transient protection devices to assure reliable operation even when driving
inductive load circuits such as relays or solenoids. The model 423 is available
only in a fixed flash rate version.
Mechanical & Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MTG. HOLES
156 DIA.
(4 PLACES)
.90
2.25
L
O
A
D
2.65
+
+
Alternate Wiring
.250 Quick Connect
Terminals
Timing Diagram . . . . . . . . . . . . . . .
Output Always Turns ON First
With Application Of Control Voltage
ON time = OFF time
ON
Output
.27
.36
How To Find The Flash Rate. . . . . . . . . . . . . . . . . .
The timing diagram shown below is for an application that
requires the load circuit to be ON for 60 milliseconds and OFF for
60 milliseconds. (Remember - the ON and OFF times will
essentially be equal due to the 50% duty cycle specification
inherent in the model 423)
The voltage across the load circuit would look something this:
ON Time = .06 Second (60 milliseconds)
CLOSED
OPEN
.76
.20
-
L
O
A
D
AC
DC
OPERATING
VOLTAGE
AC
DC
OPERATING
VOLTAGE
-
1.70
OFF Time = .06 Second (60 milliseconds)
Start Switch
Flashing Output Begins When
Start Switch Is Closed
ON
Operating Voltage
50%
ON
50%
OFF
Flash Period = ON + OFF Time
Flash Period = .06 + .06 = .12Seconds
Flash Rate in Flashes Per Minute (F P M)
F P M = 60 ÷ Flash Period
F P M = 60 ÷ .12 = 500 Flashes-Per-Minute
Solid State Timers and Controllers
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage: 5V DC, 12V DC, 24V DC, 48V DC.
Voltage Tolerances: ±20%.
Timing Mode: Flasher.
Fixed Flash Rate: Factory fixed at any rate from 1 to 600,000 flashes-perminute (FPM)
Flash Rate Duty Cycle: 50%.
Flash Rate Duty Cycle Tolerance: ±10%.
Tolerances On Flashing Rate: ±10%
Flash Rate Variation: Less than 4% over full temperature and voltage range.
Repeatability Of Flashing Period: ±1% at stabilized operating voltage temperature.
Recycle Time: Operating voltage must be removed for a minimum of 10
milliseconds to assure that the flasher and output circuits are
reset.
Output Rating: 0 to 1A inductive with inrush current to 20A for 10
milliseconds.
Output Switch Characteristics: 3 volt drop maximum across output switch when ON and load
current is 1A, 5mA leakage when OFF.
Dielectric: 1500V rms all terminals to case.
Operating Temperature: -20˚C to +85˚C.
Construction: Encapsulated module with .25 quick connect wiring
terminals.
Data Sheet Revision Date: September 5, 2000
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Part Number
423 -
Operating Voltage
Flash Rate
5V DC
12V DC
24V DC
48V DC
Specify In
Flashes Per Minute
FPM
From 1 To 600,000
Examples Of Part Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
423 - 12VDC - 90
Is a model 423 with 12V DC operating voltage, with a fixed FPM (Flashes Per Minute)
of 90
Voltage to the load circuit is ON for 333 milliseconds, and OFF for 333 milliseconds.
423 - 24VDC - 500
Is a model 423 with 24V DC operating voltage, with a fixed FPM (Flashes Per Minute)
of 500.
Voltage to the load circuit is ON for 60 milliseconds, and OFF for 60 milliseconds.
423 - 24VDC - 30000 Is a model 423 with 24V DC operating voltage, with a fixed FPM (Flashes Per Minute)
of 30,000.
Voltage to the load circuit is ON for 1 millisecond, and OFF for 1 millisecond.