Download Heat Transfer Equipment Wort kettle – External calandria

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Thermal comfort wikipedia , lookup

Radiator (engine cooling) wikipedia , lookup

Hypothermia wikipedia , lookup

Passive solar building design wikipedia , lookup

Space Shuttle thermal protection system wikipedia , lookup

HVAC wikipedia , lookup

Insulated glazing wikipedia , lookup

Underfloor heating wikipedia , lookup

Thermal conductivity wikipedia , lookup

Convection wikipedia , lookup

Heat pipe wikipedia , lookup

Heat sink wikipedia , lookup

Thermoregulation wikipedia , lookup

Dynamic insulation wikipedia , lookup

Solar water heating wikipedia , lookup

Intercooler wikipedia , lookup

Solar air conditioning wikipedia , lookup

Heat equation wikipedia , lookup

Cogeneration wikipedia , lookup

Building insulation materials wikipedia , lookup

Heat exchanger wikipedia , lookup

Economizer wikipedia , lookup

Copper in heat exchangers wikipedia , lookup

Heat wave wikipedia , lookup

R-value (insulation) wikipedia , lookup

Thermal conduction wikipedia , lookup

Hyperthermia wikipedia , lookup

Transcript
So Far:
Conservation of Mass and Energy
Pressure Drop in Pipes
Flow Measurement Instruments
Flow Control (Valves)
Types of Pumps and Pump Sizing
This Week:
Short Course in Thermodynamics
- Energy Balance, Steam
Heat Transfer
Energy Balance Example
The power goes out at your brewery due to
an overheated transformer, shutting down
your fermentation cooling mechanism.
Consider a 25 m3 cylindroconical vessel
that is full with a product at 10oC, specific
heat of 3.4 kJ/kg.K, and density of 1025
kg/m3. Assuming that the sum of heat
gains from the surroundings and
conversion from fermentation is 7 kW,
determine the temperature after 4 hours.
How would the 7 kW load change over
time?
Energy Balance Example
Water at 20oC and 15 kg/s is mixed with
water at 80oC and 25 kg/s. This mixture
then passes through a cooler, which
decreases it’s temperature to 34oC.
Determine:
a. the temperature after mixing
b. rate of heat transfer in the cooler
Heat Transfer Equipment
Mash Tun – External heating jacket
Kettle – External jackets/panels, internal coils,
internal or external calandria
Wort cooler – Plate heat exchanger
Fermenter – Internal or external coils or panels
Pasteurisers – Plate heat exchangers, Tunnel
Refrigeration equipment – Shell and tube heat
exchangers, evaporative condensers
Steam and hot water equipment – Shell and tube
Heat Transfer Equipment
Steam
in
Wort
Steam
out
Mash Tun – External heating jacket
Heat Transfer Equipment
Mash Tun – External heating jacket
Heat Transfer Equipment
Steam
Wort kettle – Internal calandria
Heat Transfer Equipment
Steam
Wort kettle – External calandria
Heat Transfer Equipment
Wort kettle – Internal calandria
Heat Transfer Equipment
Plate Heat Exchanger
Heat Transfer Equipment
Plate Heat Exchanger
Heat Transfer Equipment
Shell and tube heat exchanger
Heat Transfer Equipment
Watch Peppermill Hotel and Casino Heat
Exchanger Video
Heat Transfer
Transfer of energy from a high temperature
to low temperature
Conservation of Energy
Ein – Eout = Esystem
Qin = m(u2 – u1) = mc(T2-T1)
Qin
Wort
Heat Transfer
Rate of Ein – Rate of Eout = Rate of E Accumulation
 Q out  m (hin  hout )  0
 c p Tin  Tout 
Q out  m
Qout
min
Wort
Calculate the rate of heat transfer required to
cool 100 L/min of wort from 85 to 25C. The wort
has a density of 975 kg/m3 and specific heat of
4.0 kJ/kg.K.
Heat Transfer
Rate of Ein – Rate of Eout = Rate of E Accumulation
H2O
Wort


Q in, H 2O  m H 2O c p , H 2O TH 2O,in  TH 2O,out  0
 Q out, wort  m wort c p , wort Twort,in  Twort,out   0


 wort c p,wort Twort,in  Twort,out   m
 H 2Oc p, H 2O TH 2O,in  TH 2O,out  0
m
Heat Transfer
Rate of Ein – Rate of Eout = Rate of E Accumulation
H2O
Wort
Wort is being cooled with chilled water in a heat
exchanger. The wort enters at 85C with a flow
rate of 100 L/min and it exits the heat exchanger
at 25C. The chilled water enters at 5C with a
flow rate of 175 L/min. The specific heat of the
wort and water are 3.5 and 4.2 kJ/kg.K Determine
the exit temperature of the chilled water.
Conduction
Transfer of microscopic kinetic energy from one
molecule to another
1-D Heat Transfer, Fourier Equation:
T

Q  kA
x
or
T

Q
R
x
R
kA
A 0.5 m2, 1.75 cm thick stainless steel plate (k =
50 W/m.K) has surface temperatures of 22.5 and
20C. Calculate the rate of heat transfer through
the plate.
Conduction
Same equations apply for multi-layer systems
1-D Heat Transfer, Fourier Equation:
T

Q
RTotal
RTotal
x3
x1
x2



 ...
k1 A k 2 A k3 A
How would the rate of heat transfer change if a
2.5 cm thick layer of insulation (k = 0.05 W/m.K)
were added to the “low” temperature side of the
plate?
What is the temperature at the interface of the
stainless steel and insulation?
Draw the temperature profile of the system.
Conduction
Hollow cylinders (pipes)
r1
RTotal
r2
x

kAm




r2  r1 

Am  2L
 r2 
 ln

r1 

A 3 cm diameter, 15 m long pipe carries hot wort
at 85C. The pipe has 1.0 cm thick insulation,
which has thermal conductivity of 0.08 W/m.K.
The insulation exterior surface temperature is
35C. Determine the rate of heat loss from the
pipe.
Convection
Transfer of heat due to a moving fluid
Natural convection – buoyant forces drive flow
Temperature
Forced convection – mechanical forces drive flow
Fluid
Wall
Tfluid
Twall

Q convection  hA T fluid  Twall

Heat Transfer
Overall Heat Transfer Coefficient
T

Q  U total AT 
Rtotal
1
x
Rconduction 
Rconvection 
kA
hA
For “thin walled” heat exchangers, Ai = Ao
1
1
x
1



Uo houtside kw hinside
Convection
A tube-in-tube heat exchanger carries hot wort at
85C in the inner tube and chilled water at 5C in
the outer tube. The tube wall thickness is 4 mm
and its thermal conductivity is 100 W/m.K. The
wort film coefficient is 750 W/m2.K and the chilled
water film coefficient is 3000 W/m2K. Determine
the overall heat transfer coefficient and the rate of
heat transfer per meter of heat exchanger length.
The diameter of the pipe is 4.0 cm.
Convection
Condensation
Constant temperature process
Occurs when a saturated comes in contact
with a surface with temperature below Tsat
for the vapor
Film coefficients: 5,000-20,000 W/m2.K
Boiling
Constant temperature process
Some surface roughness promotes boiling
Bubbles rise – significant natural convection
Fraction of surface “wetted” effects Q
Fig 9, page 114 in Kunze.
Radiation
Vibrating atoms within substance give off photons
Energy Radiated  T
4
Emissivity of common substances
Polished aluminum: 0.04
Stainless steel:
0.60
Brick:
0.93
Water:
0.95
Snow:
1.00
Radiation between surface and surroundings:

4
4

Q   surf Asurf Tsurf  Tsurr

Radiation
Sometimes, we’ll make an analogy to convection

Q
rad  hrad Asurf Tsurf  Tsurr 
A 3 cm diameter, 15 m long pipe carries hot wort
at 85C. The pipe has 1.0 cm thick insulation,
which has thermal conductivity of 0.08 W/m.K.
The insulation exterior surface temperature is
35C and its emissivity is 0.85. The temperature of
the surroundings is 20C. Determine the rate of
heat loss by radiation.
T1
T
T2
Length
Temperature
Temperature
Log Mean Temperature Difference
Parallel Flow
Counter Flow
T1
T
T2
Length
Log Mean Temperature Difference
T1  T2
Tm 
T1
ln
T2
A tube-in-tube, counterflow heat exchanger carries hot
wort at 85C in the inner tube and chilled water at 5C in
the outer tube. The tube wall thickness is 4 mm and its
thermal conductivity is 100 W/m.K. The wort film
coefficient is 750 W/m2.K and the chilled water film
coefficient is 3000 W/m2K. Determine the overall heat
transfer coefficient and the rate of heat transfer per meter
of heat exchanger length.
Calculate the LMTD.
Fouling
Layers of dirt, particles, biological growth, etc.
effect resistance to heat transfer
1
U o, dirty
1

 Ro  Ri
Uo
We cannot predict fouling factors analytically
Allow for fouling factors when sizing heat transfer
equipment
Historical information from similar applications
Little fouling in water side, more on product
Typical values for film coefficient, p. 122
Heat Exchanger Sizing
Beer, dispensed at a rate of 0.03 kg/s, is chilled in an ice
bath from 18C to 8C. The beer flows through a
stainless steel cooling coil with a 10 mm o.d., 9 mm i.d.,
and thermal conductivity of 100 W/m.K. The specific
heat of the beer is 4.2 kJ/kg.K and the film heat transfer
coefficients on the product and coolant sides are 5000
W/m2.K and 800 W/m2.K, respectively. The fouling
factors on the product and coolant sides are 0.0008 and
0.00001 m2K/W. Assume that the heat exchanger is thin
walled.
a. Determine the heat transfer rate
b. Determine the LMTD
c. Determine the overall heat transfer coefficient
d. Determine the outside area required
e. Determine the length of tube required
Heat Losses
Total Heat Loss = Convection + Radiation
Preventing heat loss, insulation
Air – low thermal conductivity
Air, good
Water – relatively high thermal conductivity
Water, bad
Vessels/pipes above ambient temperature –
open pore structure to allow water vapor out
Vessels/pipes below ambient temperature closed pore structure to avoid condensation