* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 800 kVA - 1153 Amps per phase
Power over Ethernet wikipedia , lookup
Current source wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Audio power wikipedia , lookup
Electrical ballast wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power factor wikipedia , lookup
Power inverter wikipedia , lookup
Electric power system wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Standby power wikipedia , lookup
Electrical substation wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Power MOSFET wikipedia , lookup
Opto-isolator wikipedia , lookup
Electrification wikipedia , lookup
Voltage regulator wikipedia , lookup
Three-phase electric power wikipedia , lookup
Stray voltage wikipedia , lookup
Surge protector wikipedia , lookup
History of electric power transmission wikipedia , lookup
Buck converter wikipedia , lookup
Power engineering wikipedia , lookup
Power electronics wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
MODEL : PP 800 SP Powered by: GENERATING SET PERFORMANCE 50Hz VOLTAGE V400 PHASES Three PRIME RATED POWER 800kVA STANDBY RATED POWER 900kVA POWER FACTOR 0.80 PF FUEL USAGE @ 75% 130.0 L/hr 60Hz ENGINE ENGINE PERKINS 4006-23TAG3A PERFORMANCE 50Hz 60Hz BASELOAD RATED POWER TBA PRIME RATED POWER 760KWm STANDBY RATED POWER 795KWm FUEL CONSUMPTION 172 L/hr @ 100% 130 L/hr @ 75% 90 L/hr @ 50% TYPE Diesel 4 stroke ASPIRATION Turbocharged and air to air charge INJECTION TYPE Direct injection ENGINE GOVERNOR Electronic governor CYLINDERS AND ARRANGEMENT Six in line BORE AND STROKE 160mm x 190mm COMPRESSION RATIO 13.6 : 1 ELECTRICAL SYSTEM VOLTAGE 24 volt BATTERY TYPE Lead acid, 24V DERATING FOR TEMPERATURE 40deg C DERATING FOR ALTITUDE 1000m DERATING FOR HUMIDITY 90% ALTERNATOR ALTERNATOR PERFORMANCE STAMFORD 50Hz MODEL HCI634G BASELOAD RATED POWER 40 deg C 760kVA PRIME RATED POWER 40 deg C 810kVA STANDBY RATED POWER 40 deg C 830kVA STANDBY RATED POWER 27 deg C 860kVA EFFICIENCY 94% STANDARD WING CONNECTIONS Star Delta EXCITER Separately excited by P.M.G POLES 4 poles PHASES Three phases WIRES 6 leads VOLTAGE REGULATION +/- 0.5% INSULATION CLASS Class H ENCLOSURE IP23 MAXIMUM OVERSPEED 150% STANDARD AVR MODEL MX341 OPTIONAL AVR MODEL TBA DERATING FOR TEMPERATURE 40 deg C DERATING FOR ALTITUDE 1000mm 60Hz DIMENSIONS DIMENSIONS AND CAPACITY STANDARD MODELS SOUNDPROOFED TYPE 85dB(A)@ 1 metre INTEGATED FUEL TANK CAPACITY WEIGHT STANDARD OPTIONAL KG LENGTH WIDTH HEIGHT 11000kg 6100mm 2500mm 2700mm 950 GENERATOR SET EQUIPMENT STANDARD MODELS Heavy duty steel base frame Pad type anti– vibration dampers Integrated fuel tank, base mounted Silencer industrial type (open skid type) 24V battery Key start switch Emergency stop button TBA DIMENSIONS CONTROLLER AUTOMATIC MODELS – EQUIPMENT 4 poles ABB circuit breaker, electronic control unit ComAp AMF25-NT control panel box key, emergency stop button, water jacket heater, battery charger, anti condensation heater. AUTOMATIC MODELS – PROTECTORS Low oil pressure, low fuel level, overload, over/ under frequency, low voltage, over/ under battery voltage, belt breakage. AUTOMATIC MODELS – INSTRUMENTATION Voltmeter, ammeter (3 phases), frequency meter, hour– meter, battery voltage, fuel level. 4000 Series 4006-23TAG3A Diesel Engine – ElectropaK 760 kWm at 1500 rpm 795 kWm at 1800 rpm Economic power Individual 4 valve cylinder heads giving optimised gas flows Unit fuel injectors ensure ultra fine fuel atomisation and hence controlled rapid combustion Commonality of components with other engines in the 4000 Series family for reduced stocking levels. Reliable power The Perkins 4000 Series is a family of 6, 8, 12 and 16 cylinder diesel engines, designed to address today's uncompromising demands within the power generation industry with particular aim at the standby market sector. Developed from a proven engine range that offers superior performance and reliability. The 4006-23TAG3A is a newly developed, turbocharged and air-to-air charge cooled, 6 cylinder diesel engine offered with either temperate or tropical cooling. Its premium features and design provide economic and durable operation as well as an exceptional power to weight ratio, excellent load acceptance and improved gaseous emissions, plus the overall performance and reliability characteristics essential to the power generation market. Engine Speed (rev/min) Type of Operation Developed and tested using the latest engineering techniques Piston temperatures controlled by an advanced gallery jet cooling system Tolerant of a wide range of temperature without derate Perkins global product support is designed to enhance the customer experience of owning a Perkins powered machine. We deliver this through the quality of our distribution network, extensive global coverage and a range of Perkins supported OEM partnership options. So whether you are an end-user or an equipment manufacturer our engine expertise is essential to your success Compact, clean and efficient power Exceptional power to weight ratio and compact size give optimum power density for easier transportation and installation Designed to provide excellent service access for ease of maintenance Engines to comply with major international standards Low gaseous emissions that will satisfy the requirements of 1⁄2 TA Luft (1986) Engine Power Typical Generator Output (Net) Gross Net kVA kWe kWm bhp kWm bhp 1500 Continuous Baseload Prime Power Standby (maximum) 640 800 900 512 640 720 566 705 786 759 945 1054 540 679 760 724 911 1019 1800 Continuous Baseload Prime Power Standby (maximum) 675 844 938 540 675 750 614 759 839 823 1018 1125 570 715 795 764 959 1066 The above ratings represent the engine performance capabilities to conditions specified in ISO 8528/1, ISO 3046/1:1986, BS 5514/1. Derating may be required for conditions outside these; consult Perkins Engines Company Limited. Generator powers are typical and are based on an average alternator efficiency and a power factor (cos. θ) of 0.8. Fuel specification: BS 2869: Part 2 1998 Class A2 or ASTM D975 D2. Lubricating oil: 15W40 to API CG4. Rating Definitions Baseload Power: Power available for continuous full load operation. No overload is permitted on baseload power. Prime Power: Power available at variable load with a load factor not exceeding 80% of the prime power rating. There is no overload permitted on baseload power. Standby Power: Power available in the event of a main power network failure up to a maximum of 500 hours per year of which up to 300 hours may be run continuously. Load factor may be up to 100% of standby power. No overload is permitted. All information in this document is substantially correct at time of printing and may be altered subsequently Publication No. 1739/01/08 Produced in England ©2006 Perkins Engines Company Limited 4000 Series 4006-23TAG3A Standard ElectropaK Specification Air inlet 1,643 mm 1,706mm 3,027mm 2,955 mm Mounted air filter Fuel system 1,964mm 1,792 mm Direct fuel injection system, fuel lift pump Fuel cooler Governing 2,414mm 2,342 mm Heinzmann digital governor – governing to ISO 8528-5 Class G2 Lubrication system Wet sump with filler and dipstick Lubrication oil filters Oil cooler with separate filter header Engine Speed Cooling system Standby Twin thermostats, water pump System designed for ambients up to 35ºC or 50ºC Radiator supplied loose incorporating air-to-air charge cooler Electrical equipment 24 volt starter motor, 24 volt 70 amp battery charging alternator with integral voltage regulator and activating switch High coolant temperature switch Low oil pressure switch Flywheel and Housing SAE J620 size 18 flywheel SAE ‘0’ flywheel housing Fuel Consumption 1500 rev/min 1800 rev/min g/kWh l/hr g/kWh l/hr 212 User’s Handbook and Parts Manual Optional Equipment Heavy-duty air cleaners – paper element with pre-cleaner Changeover lubrication oil filter Changeover fuel filter Immersion heater with thermostat Additional manuals 4 metre wiring harness Tropical or temperate radiator kit Temperate fan Perkins Engines Company Limited Peterborough PE1 5NA United Kingdom Telephone +44 (0)1733 583000 Fax +44 (0)1733 582240 www.perkins.com All information in this document is substantially correct at time of printing and may be altered subsequently Publication No. 1739/01/08 Produced in England ©2006 Perkins Engines Company Limited 230 224 Prime power 210 172 226 200 Baseload power 208 137 213 152 75% of prime power 210 130 214 144 50% of prime power 213 90 205 96 General Data Number of cylinders Cylinder arrangement Cycle Induction system Literature 194 Combustion system Cooling system Bore and stroke Displacement Compression ratio Direction of rotation Firing order Total lubrication system capacity Total coolant capacity Length Width Height Dry weight (engine) Distributed by 6 Vertical in-line 4 stroke Turbocharged and air-to-air charge cooled Direct injection Water-cooled 160 x 190 mm 22.921 litres 13.6:1 Anti-clockwise, viewed on flywheel 1, 5, 3, 6, 2, 4 113.4 litres 105 litres 3,027 mm 1,706 mm 1,964 mm 2,524 kg HCI634G - Technical Data Sheet HCI634G SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359. Other standards and certifications can be considered on request. Standard generators feature a main stator with 6 ends brought out to the terminals, which are mounted on the frame at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access. VOLTAGE REGULATORS SHAFT & KEYS MX321 AVR - STANDARD All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. This sophisticated Automatic Voltage Regulator (AVR) is incorporated into the Stamford Permanent Magnet Generator (PMG) system and is fitted as standard to generators of this type. The PMG provides power via the AVR to the main exciter, giving a source of constant excitation power independent of generator output. The main exciter output is then fed to the main rotor, through a full wave bridge, protected by a surge suppressor. The AVR has in-built protection against sustained overexcitation, caused by internal or external faults. This de-excites the machine after a minimum of 5 seconds. Over voltage protection is built-in and short circuit current level adjustments is an optional facility. WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th …) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion. INSULATION/IMPREGNATION The insulation system is class 'H'. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. QUALITY ASSURANCE Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001. The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 61000-6-2:2001. At no time will the steady-state voltage regulation exceed 2%. NB Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing typical of product range. 2 HCI634G WINDING 312 CONTROL SYSTEM A.V.R. SEPARATELY EXCITED BY P.M.G. MX321 VOLTAGE REGULATION SUSTAINED SHORT CIRCUIT ± 0.5 % With 4% ENGINE GOVERNING REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7) CLASS H INSULATION SYSTEM IP23 PROTECTION 0.8 RATED POWER FACTOR DOUBLE LAYER LAP STATOR WINDING TWO THIRDS WINDING PITCH 6 WINDING LEADS STATOR WDG. RESISTANCE 0.003 Ohms PER PHASE AT 22°C STAR CONNECTED ROTOR WDG. RESISTANCE 1.75 Ohms at 22°C R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% MAXIMUM OVERSPEED 2250 Rev/Min BALL. 6224 (ISO) BEARING DRIVE END BALL. 6317 (ISO) BEARING NON-DRIVE END 1 BEARING 2 BEARING WEIGHT COMP. GENERATOR 1965 kg 1989 kg WEIGHT WOUND STATOR 934 kg 934 kg WEIGHT WOUND ROTOR 814 kg 766 kg 2 WR² INERTIA 17.8009 kgm2 18.3482 kgm 2023kg 2029kg 183 x 92 x 140(cm) 183 x 92 x 140(cm) 50 Hz 60 Hz SHIPPING WEIGHTS in a crate PACKING CRATE SIZE THF<2% TIF<50 1.614 m³/sec 3420 cfm 1.961 m³/sec 4156 cfm TELEPHONE INTERFERENCE COOLING AIR VOLTAGE STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277 VOLTAGE DELTA 220 230 240 254 240 254 266 277 kVA BASE RATING FOR REACTANCE VALUES Xd DIR. AXIS SYNCHRONOUS 800 800 800 800 875 925 963 1000 3.14 2.83 2.63 2.34 3.53 3.34 3.18 3.03 X'd DIR. AXIS TRANSIENT 0.25 0.23 0.21 0.19 0.28 0.26 0.25 0.24 X''d DIR. AXIS SUBTRANSIENT 0.18 0.16 0.15 0.13 0.21 0.20 0.19 0.18 Xq QUAD. AXIS REACTANCE 1.88 1.70 1.58 1.40 2.10 1.98 1.89 1.80 X''q QUAD. AXIS SUBTRANSIENT 0.21 0.19 0.18 0.16 0.24 0.23 0.22 0.21 XL LEAKAGE REACTANCE 0.10 0.09 0.08 0.07 0.12 0.11 0.10 0.10 X2 NEGATIVE SEQUENCE 0.22 0.20 0.19 0.17 0.24 0.23 0.22 0.21 X0 ZERO SEQUENCE 0.03 0.03 0.03 0.02 0.03 0.03 0.03 0.03 REACTANCES ARE SATURATED T'd TRANSIENT TIME CONST. T''d SUB-TRANSTIME CONST. T'do O.C. FIELD TIME CONST. Ta ARMATURE TIME CONST. SHORT CIRCUIT RATIO VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED 0.185 0.025 2.35 0.04 1/Xd 3 50 Hz 4 HCI634G Winding 312 THREE PHASE EFFICIENCY CURVES HCI634G Winding 312 Locked Rotor Motor Starting Curve 50 Hz 30 346V 380V 400V 415V 440V PER CENT TRANSIENT VOLTAGE DIP . 25 20 15 10 5 0 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 LOCKED ROTOR kVA 60 Hz 30 380V 416V 440V 1800 2000 460V 480V PER CENT TRANSIENT VOLTAGE DIP . 25 20 15 10 5 0 0 200 400 600 800 1000 1200 1400 LOCKED ROTOR kVA 6 1600 2200 2400 2600 HCI634G Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated Speed Based on star (wye) connection. 50 Hz CURRENT (Amps) 100000 SYMMETRICAL ASYMMETRICAL 10000 1000 0.001 0.01 0.1 TIME (secs) 1 10 1 10 Sustained Short Circuit = 2,900 Amps 60 Hz CURRENT (Amps) 100000 SYMMETRICAL ASYMMETRICAL 10000 1000 0.001 0.01 0.1 TIME (secs) Sustained Short Circuit = 3,500 Amps Note 1 The following multiplication factors should be used to adjust the values from curve between time 0.001 seconds and the minimum current point in respect of nominal operating voltage : 50Hz Voltage 380v 400v 415v 440v 60Hz Factor X 1.00 X 1.07 X 1.12 X 1.18 Voltage 416v 440v 460v 480v Note 2 The following multiplication factor should be used to convert the values calculated in accordance with NOTE 1 to those applicable to the various types of short circuit : 3-phase Factor x 1.00 x 1.06 x 1.12 x 1.17 The sustained current value is constant irrespective of voltage level 2-phase L-L 1-phase L-N x 1.30 x 3.20 x 2.50 2 sec. Instantaneous x 1.00 x 0.87 Minimum x 1.00 x 1.80 Sustained x 1.00 x 1.50 Max. sustained duration 10 sec. 5 sec. All other times are unchanged Note 3 Curves are drawn for Star (Wye) connected machines. For Delta connection multiply the Curve current value by 1.732 7 HCI634G Winding 312 0.8 Power Factor RATINGS Class - Temp Rise 50Hz 60Hz Cont. F - 105/40°C Cont. H - 125/40°C Standby - 150/40°C Standby - 163/27°C Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440 Delta (V) 220 230 240 254 220 230 240 254 220 230 240 254 220 230 240 254 kVA 750 760 750 750 800 810 800 800 820 830 820 820 850 860 850 850 kW 600 608 600 600 640 648 640 640 656 664 656 656 680 688 680 680 Efficiency (%) 94.5 94.6 94.8 95.0 94.2 94.4 94.6 94.8 94.1 94.3 94.5 94.7 93.9 94.2 94.4 94.6 kW Input 635 643 633 632 679 686 677 675 697 704 694 693 724 730 720 719 Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480 Delta (V) 240 254 266 277 240 254 266 277 240 254 266 277 240 254 266 277 kVA 813 844 888 913 875 925 963 1000 913 969 1008 1046 950 1000 1044 1088 kW 650 675 710 730 700 740 770 800 730 775 806 837 760 800 835 870 Efficiency (%) 94.6 94.7 94.8 94.8 94.4 94.5 94.5 94.6 94.2 94.3 94.4 94.4 94.1 94.2 94.3 94.3 713 749 770 742 783 815 846 775 822 854 886 808 849 886 923 kW Input 688 DIMENSIONS © 2002 Newage International Limited. Reprinted with permission of N.I. only. Printed in England. SAE 14 18 21 24 AN 25.4 15.87 0 0 PO Box 17 • Barnack Road • Stamford • Lincolnshire • PE9 2NB Tel: 00 44 (0)1780 484000 • Fax: 00 44 (0)1780 484100 Website: www.newage-avkseg.com TD_HCI634G.GB_05.03_02_GB New InteliLite NT CREATIVE ENGINEERING SINGLE SET GEN-SET CONTROLLER Description InteliLiteNT models are the new integrated controllers for gen-sets operating in single standby mode. Based on the field proven InteliLite architecture, the new controllers fulfill every requirement needed for AMF and MRS applications – including modem and Internet control, user configuration and complete gen-set monitoring and protection. InteliLiteNT controllers are easy to use and feature an intuitive user interface with graphic display. The built-in event and performance log with backed-up real time clock makes troubleshooting even simpler. The new design brings seamless integration with the latest breed of EFI diesel engines from all major manufacturers. This offers a higher level of functionality with users able to display a full range of values from the EFI engine on standard analog gauges and true RMS measurement of electric values. Benefits Less wiring and components Less engineering and programming History log – easy troubleshooting and warranty claim handling Remote monitoring reduced call-out costs of service engineers Analog gauge (VDO, Datcon, …) outputs – operator friendly Perfect price/performance ratio ComAp is a member of AMPS (The Association of Manufacturers of Power generating Systems). ComAp products meet the highest standards, with every stage of production undertaken in accordance with the ISO certification obtained in 1998. InteliLite NT Features • • • 3 phase AMF function* Over/Under frequency Over/Under voltage Voltage asymmetry Event and performance log + RTC • Event based history with 119 events* Reason, Data and Time + all important values are stored • Battery backed-up RTC • Test Run scheduler • • • • 3 phase generator protections Over/Under frequency Over/Under voltage Current/Voltage asymmetry Overcurrent/Overload • • • • User interface Graphic 128 × 64 pixels display Multiple language capability Setpoints adjustable via keyboard or PC Buttons with mechanical feedback • • • • True RMS Voltage measurement 3 phase generator and mains* voltages Voltage range 277 V p-n, 480 V p-p Maximal measured voltage 300 V p-n PT ratio range 0.1–500 • • • • True RMS current measurements 3 generator phase currents Current range 5 A Maximal measured current 10 A CT ratio range 1–5000 • • • • • • Inputs and outputs 3 configurable analog inputs 6 or 7* Binary inputs 6 or 7* Binary outputs Magnetic pick-up input D+ preexcitation terminal Optional 8 analog gauge drive outputs, compatible with VDO, Datcon gauges • Optional USB and RS232 plug-in modules • MODBUS RTU (requires RS232 module) • Internet • • • • Mechanical and operation parameters Unit dimension 120 × 180 mm Sealed front face rated for IP65 Hard plexiglass LCD cover Operation temperature -20°C – +70°C standard version -40°C – +70°C low temperature version • Power supply voltage 8–36 V • Voltage drops shorter than 50 ms do not affect operation Extension modules EFI engine support • Cummins MODBUS • Engine specific J1939 for all major manufacturers • Diagnostic messages in plain text Power measurements • Act / React Power and Power Factor per phase • Active and Reactive Energy counter IL-NT RS232 IL-NT USB IL-NT AOUT8 IL-NT RD IG-IB IGS-PTM** IGS-IOM** IGL-RA15** RS232 plug-in interface USB plug-in interface gauge plug-in interface remote display Internet module extension I/O module extension I/O module 15 LED remote annunciator * Only for Models AMF 20 and AMF 25 ** Only for Models MRS 15, MRS 16 and AMF 25 Communication interfaces or +24V or RM ALA P STO 8 GAU PLUG ULE IN MOD RS 232 CE FA ULE INTER IN MOD PLUG UTS Y OUTP ) BINAR OLLECTOR C (OPEN xx S R M 4x F xx 5x AM TS S IVER GE DR Y INPU BINAR xx S 6x MR xx F 7x AM IL-NT J1939 N CAN TENSIO I/O EX 1 MAIN 3ph ONT .C C.B .B. C SC OR RAT ROL ONT 3ph ROL id leno ure 3ph ress l So 2 3 LOAD 1 Values ATOR NGINE AS E SEL/G DIE 1 ECU GENER uest ed Req top - Spe Start/S only on 3 MAINS J1939 + Fault Codes RS15, odels M M only on 2 E GEN RPM Oil P ter Star r rnato Alte n Aux xcitatio e Pre Fue 2 15 NT EME SUR MEA E TAG VOL NT EME SUR MEA E TAG VOL ENT R CUR D+ Y BINAR TS OUTPU (OPEN TOR) C E LL O C IGS-PTM IG-IOM 1 ATOR G ANALO INPUTS or IGL-RA MAINS GENER °C E ENGIN IG-IB D IL-NT R M MODE PC PLY R SUP POWE VDC 8 to 36 + or Models AMF 20 F 25 and AM F 25 and AM S 15 d MR S 10 an els MR Mod not on MRS 16 Available models MRS 10 MANUAL AND REMOTE START CONTROLLER 3 configurable analog inputs magnetic pickup input D+ preexcitation terminal 6 binary inputs 6 binary outputs MRS 15 MANUAL AND REMOTE START CONTROLLER WITH SUPPORT FOR EFI ENGINES 3 configurable analog inputs magnetic pickup input D+ preexcitation terminal 6 binary inputs 6 binary outputs CAN with J1939 support extension modules capability event and performance log MRS 11 MANUAL AND REMOTE START CONTROLLER 3 configurable analog inputs magnetic pickup input D+ preexcitation terminal 6 binary inputs 6 binary outputs GCB control MRS 16 MANUAL AND REMOTE START CONTROLLER WITH SUPPORT FOR EFI ENGINES 3 configurable analog inputs magnetic pickup input D+ preexcitation terminal 6 binary inputs 6 binary outputs GCB control CAN with J1939 support extension modules capability event and performance log AMF 20 AUTOMATIC MAINS FAILURE START CONTROLLER 3 configurable analog inputs magnetic pickup input D+ preexcitation terminal 7 binary inputs 7 binary outputs GCB and MCB control AMF 25 AUTOMATIC MAINS FAILURE START CONTROLLER WITH SUPPORT FOR EFI ENGINE 3 configurable analog inputs magnetic pickup input D+ preexcitation terminal 7 binary inputs 7 binary outputs GCB and MCB control CAN with J1939 support extension modules capability event and performance log The Chart of Functions of InteliLiteNT Controllers FUNCTIONS/CONTROLLERS IL-NT MRS 10 IL-NT MRS 15 IL-NT MRS 11 IL-NT MRS 16 IL-NT AMF 20 IL-NT AMF 25 6/6 6/6 6/6 6/6 7/7 7/7 Analog inputs 3 3 3 3 3 3 Binary inputs/outputs Magnetic pick-up l l l l l l AMF function – – – – l l Input configuration l l l l l l Output configuration l l l l l l 3 ph / – 3 ph / – 3 ph / – 3 ph / – 3 ph / 3 ph 3 ph / 3 ph Current measurement 3 ph 3 ph, IDMT overcurrent 3 ph 3 ph, IDMT overcurrent 3 ph 3 ph, IDMT overcurrent kW/kWh measurement l/– l/l l/– l/l l/– l/l History file – l – l – l RTC with battery l l l l l l GCB/MCB control with feedback – /– – /– l /– l /– l/l l/l Battery charging alternator circuit l l l l l l Voltage measurement Gen. / Mains 1) 1) 2) 2) J1939 interface – l – l – l Internet support with IG-IB with IG-IB with IG-IB with IG-IB with IG-IB with IG-IB – IGL-RA15, IG-IOM, IGS-PTM – IGL-RA15, IG-IOM, IGS-PTM – IGL-RA15, IG-IOM, IGS-PTM 8 analog gauge drivers O O O O O O RS232 interface O O O O O O Extension modules Modem interface O O O O O O MODBUS interface O O O O O O Remote display O O O O O O Cummins MODBUS O O O O O O Key: l – O 1) 2) included excluded optional – plug-in module required Automatic GCB control without feedback Manual/Automatic GCB control, but without feedback Legend: IG-IOM/IGS-PTM: I/O extension modules IGL-RA15: Remote annunciator GCB: Generator circuit breaker MCB: Mains circuit breaker For more information about our products and solutions visit our web-page www.comap.cz Manufacturer: Local Distributor / Partner: ComAp, spol. s r. o. Czech Republic Phone:+ 420 246 012 111 Fax: + 420 266 316 647 E-mail: [email protected] Internet: www.comap.cz Features and specification are subject to change without prior notice 2007-09