Technical features of NT 85x test systems:
• Max. 131072 test points in corresponding test point units, continuity test up to 2
ADC, Kelvin measurement from 1 mΩ
• Short circuit , insulation and dielectric strength test up to 3750 VDC / 2650 VAC
• Component test of resistors, capacitors, diodes, Zener-diodes, LEDs, varistors
and surge arrestors
• Voltage measurement AC / DC, external voltage recognition
• Function test of assemblies (operating voltage up to 250 V DC/AC)
• Control and visualization of the test process via standard PC
• User-friendly operating software NT Control, language selectable: German,
English, French, Italian, Polish, Czech, Hungarian, Korean, Chinese….
• Self-diagnostics, multimeter, pin number probe
• Integration of external generators and measuring devices (programmable power
supplies AC/DC , digital multimeter…)
• Detailed report of the test runs and the test results
• Individual test sequence programming (TSE)
• Temperature and humidity report
• CAD data import (UNICAD) in consideration of the voltage levels
• Bus communication, for example MVB
NT Control
Testpanel
adaptronic Prüftechnik GmbH
Dörlesberg-Ernsthof
D-97877 Wertheim
Germany
Quality Management System
VDA 6.4
DIN EN ISO 9001
Telefon ++49 (0) 9345 / 930-0
Telefax ++49 (0) 9345 / 930-100
E-Mail [email protected]
Internet www.adaptronic.de
NT 85x
Distributed Test
for the Test of Railway Applications
Test Point Units (TPU)
Example TPU 16/7
Front-side: Test point interfaces HAN 46EE (32 used) and pin number probe socket
TPU approx. 540 x 350 x 650 mm (W x H x D) with 160 function points
We are a medium-sized company – innovative, future-oriented, certified according
DIN EN ISO 9001 / VDA 6.4 and well established on the market since more than 25 years.
At two locations in Germany, high skilled employees produce, sell and service high quality cable- and
wiring test systems as well as adaptation systems.
The TPU supports intelligent adapter cables.
The test point interfaces can be realized application specific.
The test system NT 85x is designed for application specific high voltage tests and high current tests
with functional tests for cable harnesses of large dimensions, for complete railway vehicles
assemblies up to function tests of assemblies.
Rear-side: TPU bus interfaces
The signals are concentrated in a single connection cable.
The requirements of the insulation test according EN50343 are totally covered by this test system.
Herewith electrical circuits of railway vehicles with a nominal voltage up to 440 VAC can be tested
with the dielectric strength test.
The modular software and hardware architecture allows the easy integration into existing test
procedures and production environments. Our NT 85x test system is operated via a PC with the
graphical user interface NT Control.
System Overview (example)
TPU 4.3
System Topology
car to car interface
example wagon
max. 1024 TP‘s
8
NT 85x
max. 1024 TP‘s
max. 1024 TP‘s
1
TPU
TPU
2
3
7
7
coupling area
5
7
7
control
stand
max. 16384 Test Points
(1024 x 16)
TPU
TPU 3.3
TPU 1.4
TPU 3.2
6
4
4
4
5
5
16
TPU 1.2
TPU 1.1
TPU 2.2
TPU 2.1
Adaptation points:
NT 850
TPU
1
TPU
TPU
2
3
TPU
TPU
2
3
max. 16384 Test Points
(1024 x 16)
TPU
16
1
TPU
1
Example wagon:
1
car to car interface
2
door
3
door
4
under floor duct
Example power car:
5
power units
6
door
7
ceiling duct
8
door
9
control stand
10
coupling area
max. 16384 Test Points
(1024 x 16)
TPU
16
max. 131072 Test Points
max. total length:
approx. 120 m at up to10 TPUs per interface
approx. 60 m at up to10 TPUs per interface
TPU = Test Point Unit
mobile operating panel
(example)
10
TPU 3.1
2
TPU 1.3
2
8
max. 1024 TP‘s
1
TPU
example multiple unit
5
3
TPU 4.2
TPU-trolley
(example)
9
TPU 4.1
Test Point Units (TPU)
Example TPU 16/7
Front-side: Test point interfaces HAN 46EE (32 used) and pin number probe socket
TPU approx. 540 x 350 x 650 mm (W x H x D) with 160 function points
We are a medium-sized company – innovative, future-oriented, certified according
DIN EN ISO 9001 / VDA 6.4 and well established on the market since more than 25 years.
At two locations in Germany, high skilled employees produce, sell and service high quality cable- and
wiring test systems as well as adaptation systems.
The TPU supports intelligent adapter cables.
The test point interfaces can be realized application specific.
The test system NT 85x is designed for application specific high voltage tests and high current tests
with functional tests for cable harnesses of large dimensions, for complete railway vehicles
assemblies up to function tests of assemblies.
Rear-side: TPU bus interfaces
The signals are concentrated in a single connection cable.
The requirements of the insulation test according EN50343 are totally covered by this test system.
Herewith electrical circuits of railway vehicles with a nominal voltage up to 440 VAC can be tested
with the dielectric strength test.
The modular software and hardware architecture allows the easy integration into existing test
procedures and production environments. Our NT 85x test system is operated via a PC with the
graphical user interface NT Control.
System Overview (example)
TPU 4.3
System Topology
car to car interface
example wagon
example multiple unit
5
max. 1024 TP‘s
max. 1024 TP‘s
coupling area
5
8
3
max. 1024 TP‘s
TPU 4.2
7
7
7
7
control
stand
max. 1024 TP‘s
10
8
TPU
NT 85x
1
TPU
TPU
2
3
max. 16384 Test Points
(1024 x 16)
TPU
TPU 3.3
TPU 1.4
1
TPU 3.2
TPU 3.1
2
6
4
4
4
5
5
16
TPU 1.3
TPU 1.2
TPU 1.1
TPU 2.2
TPU 2.1
Adaptation points:
NT 850
2
TPU
1
TPU
TPU
2
3
TPU
TPU
2
3
max. 16384 Test Points
(1024 x 16)
TPU
16
1
TPU
1
Example wagon:
1
car to car interface
2
door
3
door
4
under floor duct
Example power car:
5
power units
6
door
7
ceiling duct
8
door
9
control stand
10
coupling area
max. 16384 Test Points
(1024 x 16)
TPU
16
max. 131072 Test Points
max. total length:
approx. 120 m at up to10 TPUs per interface
approx. 60 m at up to10 TPUs per interface
mobile operating panel
(example)
TPU = Test Point Unit
TPU-trolley
(example)
9
TPU 4.1
Technical features of NT 85x test systems:
• Max. 131072 test points in corresponding test point units, continuity test up to 2
ADC, Kelvin measurement from 1 mΩ
• Short circuit , insulation and dielectric strength test up to 3750 VDC / 2650 VAC
• Component test of resistors, capacitors, diodes, Zener-diodes, LEDs, varistors
and surge arrestors
• Voltage measurement AC / DC, external voltage recognition
• Function test of assemblies (operating voltage up to 250 V DC/AC)
• Control and visualization of the test process via standard PC
• User-friendly operating software NT Control, language selectable: German,
English, French, Italian, Polish, Czech, Hungarian, Korean, Chinese….
• Self-diagnostics, multimeter, pin number probe
• Integration of external generators and measuring devices (programmable power
supplies AC/DC , digital multimeter…)
• Detailed report of the test runs and the test results
• Individual test sequence programming (TSE)
• Temperature and humidity report
• CAD data import (UNICAD) in consideration of the voltage levels
• Bus communication, for example MVB
NT Control
Testpanel
adaptronic Prüftechnik GmbH
Dörlesberg-Ernsthof
D-97877 Wertheim
Germany
Quality Management System
VDA 6.4
DIN EN ISO 9001
Telefon ++49 (0) 9345 / 930-0
Telefax ++49 (0) 9345 / 930-100
E-Mail [email protected]
Internet www.adaptronic.de
NT 85x
Distributed Test