Download Analog Meters Clamping to DIN Rails

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Mercury-arc valve wikipedia , lookup

Transistor wikipedia , lookup

Decibel wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Mathematics of radio engineering wikipedia , lookup

Heterodyne wikipedia , lookup

Spark-gap transmitter wikipedia , lookup

Utility frequency wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Power inverter wikipedia , lookup

Electrical substation wikipedia , lookup

Three-phase electric power wikipedia , lookup

History of electric power transmission wikipedia , lookup

Stepper motor wikipedia , lookup

Schmitt trigger wikipedia , lookup

Galvanometer wikipedia , lookup

Distribution management system wikipedia , lookup

Electrical ballast wikipedia , lookup

Variable-frequency drive wikipedia , lookup

P–n diode wikipedia , lookup

Rectifier wikipedia , lookup

Islanding wikipedia , lookup

Triode wikipedia , lookup

Current source wikipedia , lookup

Metadyne wikipedia , lookup

Power electronics wikipedia , lookup

Power MOSFET wikipedia , lookup

Multimeter wikipedia , lookup

Ohm's law wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Voltage regulator wikipedia , lookup

Opto-isolator wikipedia , lookup

Surge protector wikipedia , lookup

Buck converter wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Current mirror wikipedia , lookup

Stray voltage wikipedia , lookup

Voltage optimisation wikipedia , lookup

Alternating current wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
Analog Meters Clamping to DIN Rails
EQ
35
Data Sheet
PQ
35
ZQ
35
Analogue Meter Clamping
to DIN Rails
Applications
Electrical Data
The analog EQ 35, PQ 35, ZQ 35 meters, designed for
the measurement of current, voltage & frequency in distribution,
installations which utilizes 35 mm.DIN rails for equipment
mounting. The mounting width is 45 mm.
These meters housed in molded Polycarbonate cases are
suitable for the measurement of AC current & voltage, DC current
& voltage & Frequency. The moving iron meters indicate rms
values practically independent of wave - form even of high
harmonics. Error of indication may occur for extreme wave - forms
(eg. phase getting controls) & for frequencies above 100 kHz.
For the CT operated Ammeters, dials can be eld tted based on
CT ratio.
Frequency meters are designed to measure system
frequency from 45..65 Hz with different system voltages.
Measuring unit
Features
• Easy mounting with 35 mm Din-rail.
• Near linear scale for EQ & linear scale for PQ & ZQ
• Glass lled polycarbonate housing.
EQ 35
PQ 35
ZQ 35
moving-iron movements with shell-type system, silicon oil
damping and spring loaded jewel bearings, pivot
suspension.
moving-coil movement with core-type magnetic system,
dual spring loaded jewel bearings, pivot suspension.
moving-coil movement with core-type magnetic system,
dual spring loaded jewel bearings, pivot suspension,
alongwith frequency transducer.
Scale and Pointer
PQ 35/ ZQ 35
Scale Division
Scale Length
Over-Range Scaling
Ammeters
Voltmeters for
use on Voltage
transformers
Scale Interchangeability
: Knife- edge pointer
: Interchangeble
: 0...900
: Near linear above 10% of
nominal full scale value
: Linear
: Coarse-ne
: 38mm
: 2 times rated current
: 1.2 times rated voltage
: Possible in all the ranges
Material of case
Color of case
Material of window
Position of use
Terminals
Dimensions LxWxH
Weight approx.
Short duration
Voltmeters
Ammeters
Power consumption EQ 35
Voltmeters
Ammeters
5 second max.
1 second max.
Protection class
Enclosure code
: Projecting case clamping to 35
mm mounting rail complying with
DIN EN 50022
: Thermoplastics, selfextinguishing
: Ivory
: Polycarbonate
: vertical ± 50
: Brass Hexagon studs, M4 screw
& self lifting wire clamps E3
(DIN 46282)
: 85 mm x 45 mmx 65 mm
: EQ 35 PQ 35 ZQ 35
0.1 kg 0.1kg
0.1kg
: 1.2 times rated voltage / current
(5s max.)
: 2 times rated voltage max.
1000V upto 5s
: 10 times rated current 10 times
: approx. 1.5 ... 3 VA
: approx. 0.5 ... 1VA
: 10 times(200A max)
: 40 times (250A max)
:I
: IP 52 case
IP 00 for terminals without
protection against accidental
contact
: group A according to VDE 0110
: 660 V
: 3 kV 50 Hz, 1 min acc. To DIN
57 410
Accuracy at Reference Conditions
Accuracy class
: 1.5 according to EN 60051/ IS
1248
Reference conditions :
Frequency
Wave form
Other conditions
0
0
: 23 C +/- 2 C
: Nominal position +/-1.0
: Rated value of measured
quantity
: 45...65Hz
: Sinusoidal, Distortion
factor <= 5%
: As per EN 60051/IS 1248
Nominal Range of Use
Ambient Temperature
Position of Use
Frequency
Wave form
Other conditions
Position of use
Frequency
Mechanical Data
Case details
Continuously
Ambient Temperature
Position of Use
Input Quantity
Specications
Pointer
Dial
Pointer Deection
Scale Characteristics
EQ 35
Overload capacity
Insulation class
Rated insulation
voltage
Dielectric test
Functional Principle
: EQ 35 AC Voltage or AC current
PQ 35 DC Voltage or DC current
ZQ 35 Frequency
Stray magnetic eld
0
: 0 ... 50 C
0
: Vertical +/-5.
: 15 ... 100 Hz (voltage)
15 ... 400 Hz (current)
: Sinusoidal, Distortion
factor <= 5%
: As per EN 60051/IS 1248
0
: Nominal position +/- 5
: 15 ... 100 Hz (voltage)
15 ... 400 Hz (current)
: 0.5 mT
Environmental Conditions
Climatic Suitability
: Climatic class 3 according
to VDE/VDI 3540
Storage temperaturerange
Relative Humidity
: -25 ... + 65 C
Shock Resistance
Vibration Resistance
0
: < 75% annual average,
non-condensing
: 15 g, 11ms
: 1.5 g, at about 50 Hz
Measuring Ranges
Options
Dial
AC Current EQ 35
1A
1.2 A
5A
6A
10 A
12 A
15 A
(For use on
Current transformer1 )
N/1 A
N/5 A
AC Voltage EQ 35
100 V
120 V
150 V
250 V
300 V
500 V
600 V
(For use on
Potential transformer1)
.../ 100 V sec.
.../ 110 V sec
1
1.5
2.5
4
5
6
10
15
20
25
40
60
100
150
250
400
600
1
1.5
2.5
4
6
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
A
A
A
A
A
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
internal
resistance
100m V
150m V
250m V
400m V
600m V
1V
1.5 V
2.5 V
4V
6V
10 V
15 V
25 V
40 V
60 V
100 V
150 V
250 V
400 V
500 V
600 V
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
Coloured sector
Logo on the dial
Overload scaling EQ 35
:
:
:
:
marked initial and end values
to be specied e.g. “Generator”
to be specied
red, green or blue for important
scale values
: red, green or blue within scale
division
: none or to be specied
: no overload range
Applicable Standards
please state transformer ratio ordering.
1) full scale value = 2 times rated current (overload scaling)
2) full scale value = 1.2 times rated voltage (overload scaling)
DC current PQ 35
DC voltage PQ 35
voltage drop
aprox.
Blank dial
Additional lettering
Additional guring
Coloured marks
/ V*
/V
/V
/V
/V
/V
/V
/V
/V
/V
/V
/V
/V
/V
/V
/V
/V
/V
/V
/V
/V
Case & Cutout dimensions
: DIN 43700 / IS 2419
Scale & Pointer
: DIN 43802 / IS 1248
Connections & Terminal
: DIN 43807 / IS 1248
marking
Safety Requirements &
: IEC / EN 61010
Protective measures
:
Performance Specication
IEC / EN 60051
Front Frame / Bezel
: DIN 43718
UL Combustibility (Case &
: UL 94 V-0
Bezel)
European Directives(EMC
Directive) 73/23/EEC (Low
voltage directive) &
ammendment 93/68/EEC,for
CE mark
: 89/336/EEC
Mounting rails
: DIN EN 50 022
Dimensions
20
For use with external shunt
/V
/V
45
1000
1000
85
60 mV
150 mV
a total lead resistance of 0.05 is considered in the calibration
2
of the indicator for connecting leads 1 m, 2 x 0.75 mm
FREQUENCY ZQ 35
45-55 Hz
55-65 Hz
45-65 Hz
45-55 Hz
55-65 Hz
45-65 Hz
45-55 Hz
55-65 Hz
45-65 Hz
VOLTAGE ZQ 35
110 V
110 V
110 V
220 V
220 V
220 V
440 V
440 V
440 V
62
45
* the resistance values are limited to a tolerance of + 20%
20
5
4
21