Download Monitoring technique

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Heterodyne wikipedia , lookup

Power inverter wikipedia , lookup

Ground loop (electricity) wikipedia , lookup

Ohm's law wikipedia , lookup

Three-phase electric power wikipedia , lookup

Pulse-width modulation wikipedia , lookup

History of electric power transmission wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Current source wikipedia , lookup

Ground (electricity) wikipedia , lookup

Earthing system wikipedia , lookup

Electrical ballast wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Islanding wikipedia , lookup

Fault tolerance wikipedia , lookup

Electrical substation wikipedia , lookup

Rectifier wikipedia , lookup

Distribution management system wikipedia , lookup

Power electronics wikipedia , lookup

Buck converter wikipedia , lookup

Voltage regulator wikipedia , lookup

Alternating current wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Metadyne wikipedia , lookup

Surge protector wikipedia , lookup

Schmitt trigger wikipedia , lookup

Stray voltage wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Voltage optimisation wikipedia , lookup

Opto-isolator wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
Monitoring technique
Fault annunciator system EP 5966, EP 5967
infomaster
0226826
· New fault annunciation with single frequency flashlight
according to DIN 19235
· Expandable from 16 up to 160 inpus
· Open circuit operation / closed circuit operation in 2 groups
of 8 inputs selectable
· Input voltage up to max. AC/DC 240 V
· Delayed inputs
· Exchangeable front for individual scale
· Removable terminals
· Flush mounting
· Frame 72 x 144 mm
Function diagram
EP 5966:
· 16 inputs in control unit
· Output relay for common signal and audible alarm
· Built in and external connected pushbuttons for lamp test,
acknowledgment of horn and of alarm
· Extension module with 16 inputs
EP 5966/67
fault signal 1
Approvals and marking
LED 1
fault signal 2
LED 2
LED common alarm
EP 5966
output common alarm
contact 23-24
Applications
Monitoring of industrial plants and buildings
audible alarm contact 13-14
acknowledge fault signal
acknowledge audible alarm
lamp test
Circuit diagram
Function
The unit EP 5966 controls the system and includes the common alarm
output for all connected extension modules EP 5967.
For audible alarm as well as for common alarm 2 relay outputs (NO) are
available. The acknowledgement (QH and QS), as well as the lamp test
(LT) can be effected through built in and external pushbuttons. The
pushbutton lamp test (LT) is for the checking of the LED´s in the control
unit and the subsequent extension modules. The associated common
alarm output contact 23-24 will be closed.
On EP5966 and EP 5967 open circuit operation or closed circuit operation
can be selected by bridging terminals X3/X4 or X5/X6 for
2 groups of 8 inputs.
To avoid unnecessary fault signalling an operate delay of 1 s, 3 s or 10
s to the inputs is available.
The fault annunciator lamps can be marked by the customer on an
attached label. Spare labels ET 5966 are available. Extension modules
can be mounted in neighbour cabinets. In this case the connection cable
must be screened.
Indication
One LED for each signal
EP 5966 with addiational LED for common alarm
Notes
The inputs for the control signals as well as the inputs for programming
(open circuit / closed circuit) are not protected agains false connection to
mains voltage.
The inputs are not galvanic separated from the supply voltage. At DC
units 0V must always be connected to A2.
All technical data in this list relate to the state at the moment of edition. We reserve the right
for technical improvements and changes at any time.
1
EP 5966, EP 5967 / 15.09.99 d
Ordering example
Standard type
EP 5966 AC/DC 110 ... 240 V UH AC 230 V 1 s
EP 5966 AC/DC 24 ... 60 V U H DC 24 V 1 s
Article number:
0041660
· Input voltage:
AC/DC 24 ... 60 V
· Auxiliary voltage U H:
DC 24 V
· Operate delay:
1s
Operate delay
Auxiliary voltage
Supply voltage
Type
EP 5967 AC/DC 24 ... 60 V U H DC 24 V 1 s
Article number:
0041662
· Input voltage:
AC/DC 24 ... 60 V
· Auxiliary voltage U H:
DC 24 V
· Operate delay:
1s
EP 5967 AC/DC 110 ... 240 V UH AC 230 V 1 s
Operate delay
Auxiliary voltage
Supply voltage
Type
Technical data
Input
Dimensions
Auxiliary voltage UH (A1, A2): AC 24, 42, 110, 127, 230 V
DC 24 V
Special voltages:
DC 48, 60, 110, 230 V
(on request)
Voltage range:
0,8 ... 1,1 U N
Nominal consumption
EP 5966:
approx. 5 VA
EP 5967:
approx. 5 VA
Nominal frequency:
50 / 60 Hz
Min. time for input signal:
³ 100 ms + operate delay
Min. time for
acknowledgement:
³ 200 ms
Input voltage (S1 ... S16):
AC/DC 24 - 60 V
AC/DC 110 - 240 V
Width x height x depth:
Front panel cut-out:
Accessories
Spare scale:
Output
Operate delay tV:
Thermal current I th:
Switching capacity
to AC 15:
Electrical life
to AC 15 at 3 A, AC 230 V:
1 s, 3 s, 10 s
3A
3 A / AC 230 V
EN 60 947-5-1
EN 60 947-5-1
5 x 10 5 switching cycles
General data
Operating mode:
Temperature range:
Clearance and creepage
distances
overvoltage category /
contamination level:
EMC
Electrostatic discharge:
HF irradiation:
Fast transients:
Surge voltages
between
wires for power supply:
between wire and ground:
Interference suppression:
Degree of protection:
Housing:
Vibration resistance:
Climate resistance:
Wire connection:
Wire fixing:
Mounting:
Weight
EP 5966:
EP 5967:
Continuous operation
- 20 ... + 50°C
4 kV / 2
4 kV (air)
10 V / m
2 kV
72 x 144 x 134 mm
66+0,7 x 138 +1 mm
DIN VDE 0110-1 (04.97)
EN 61 000-4-2
EN 61 000-4-3
EN 61 000-4-4
2 kV
EN 61 000-4-5
4 kV
EN 61 000-4-5
Limit value class B
EN 55 011
Housing: IP 40
EN 60 529
Terminals: IP 20
EN 60 529
Thermoplastic with V0 behaviour
according to UL subject 94
Amplitude 0,35 mm
frequency 10 ... 55 Hz EN 60 068-2-6
20 / 50 / 04
EN 60 068-1
2 x 1,5 mm 2 solid DIN 46 288,
1 x 1,5 mm2 or 2 x 0,75 mm 2
stranded wire with sleeve
DIN 46 228-1/-2/-3/-4
Box terminal with wire protection
removable terminal strips
flush mounting
520 g
approx. 480 g
2
ET 5966
Application example
S1 - S16
LT
QH
QS
13/14
23/24
UQ
UE
inputs
lamp test
acknowledge audible alarm
acknowledge fault signal
relay contact audible alarm
relay contact common alarm
control voltage of the acknowledge inputs
control voltage of the inputs
with bridge X3 / X4 ww. X5 / X6 n.o. circuit operation
without bridge X3 / X4 ww. X5 / X6 n.c. circuit operation
3