* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download doctor - Shodhganga
Spark-gap transmitter wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Ground (electricity) wikipedia , lookup
Power inverter wikipedia , lookup
Electrical ballast wikipedia , lookup
Power engineering wikipedia , lookup
Current source wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Power MOSFET wikipedia , lookup
Power electronics wikipedia , lookup
Earthing system wikipedia , lookup
Single-wire earth return wikipedia , lookup
Voltage regulator wikipedia , lookup
Stray voltage wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Electrical substation wikipedia , lookup
Surge protector wikipedia , lookup
Voltage optimisation wikipedia , lookup
Opto-isolator wikipedia , lookup
History of electric power transmission wikipedia , lookup
Three-phase electric power wikipedia , lookup
Distribution management system wikipedia , lookup
Mains electricity wikipedia , lookup
Network analysis (electrical circuits) wikipedia , lookup
Buck converter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
From Dr.Amiya Prasad Dash Reader in Physics, G.M.Autonomous College Sambalpur 768004 Sambalpur Dated: CERTIFICATE This is to certify that the thesis entitled "Analysis of Transformer core behavior under transient conditions for the study of series ferroresonant circuits" being submitted by Mrs.Pratima Rath for the award of the degree of Doctor of Philosophy in Physics of the Sambalpur University,Burla,Sambalpur,Orissa is a record of bonafide research work carried out by her for more than eight years in G.M.Autonomous College,Sambalpur and University College of Engineering,Burla, Orissa and the thesis has reached the standard fulfilling the requirements of the regulation relating to the degree. No part of this thesis has been submitted to any institution or university for the award of any degree or diploma. (Amiya Prasad Dash) 2 CONTENTS Page No 4 5-7 Acknowledgement Synopsis List of Principal Symbols CHAPTER 1: INTRODUCTION CHAPTER 2: ANALYSIS OF FERRORESONANT CIRCUIT 2.1: Preliminaries 2.2: Power system ferrroresonance 2.4: Review of work done by G.W Swift and R.J Javora etal 2.5: Conclusions CHAPTER 3: TRUE SATURATION CHARACTERISTICS 3.1: Preliminaries 3.2: Meaning of true saturation characteristic 3.3: Assumptions for the saturation characteristic 4.4: Conclusions CHAPTER 4: ANALYSIS OF TRANSFORMER CORE BEHAVIOUR 4.1: Preliminaries 4.2: Expression for hysteresis loop 4.3: Hysteresis loss 4.4 Suggested methods: 4.5 Comparison of suggested methods 4.6 Experimental observations 4.7 Conclusions 9-11 12-19 20-22 23-42 CHAPTER 5: SERIES FERRORESONANT CIRCUIT UNDER TRANSIENT CONDITION 43-47 5.1 Preliminaries 5.2 Analysis of ferroresonant circuit considering core behavior 5.3 Response curve considering saturation curve as piecewise linear 5.4 Representation of B-H loop 5.5 Switching transients 5.6 Representation of magnetic characteristic of the nonlinear inductor. 5.7 General equations for the study of transients 5.8 Conclusions CHAPTER 6: SYSTEM UNDER INVESTIGATIONS AND FINDINGS 48-62 6.1: Preliminaries 6.2: System characteristics 6.3: True saturation characteristics curve 6.4: Transient of Series Ferroresonant circuit under study 6.5: Initial change of capacitor and switching angles 6.6: Effect of input voltage 3 6.7: Computed results 6.8: Experimental results 6.9: Study of transients 6.10: Conclusions CHAPTER 7: GENERAL CONCLUSIONS AND SUGGESTIONS FOR FUTURE WORK 65-68 7.1: General conclusions 7.2: Suggestions for future work REFERENCES 69-74 APPENDICES 75-87 4 ACKNOWLEDGEMENT I am most grateful to Dr.Amiya Prasad Dash, Reader in Physics, G.M.Autonomous College,Sambalpur for his sincere guidance and supervision through out this work.I am also grateful to all the staff members of G.M.Autonomous College and Electrical Engineering Department, University college of Engineering, Burla for cooperation and help during the thesis work. My sincere thanks are also to Principal, U.C.E.Burla and G.M.Autonomous College for the facilities provided at their colleges for the laboratory and computational work. My sincere thanks are also to all my colleagues and family members for their help and cooperation during this research work. I appreciate the help rendered by the laboratory staff of the Electrical Department, U.C.E.Burla and G.M.Auto.College, Sambalpur.Lastly I thank Sri B.K.Sahu for typing the manuscript and for various graphical works. Pratima Rath 5 SYNOPSIS The present thesis is an embodiment of four research papers two published in national journals and two communicated to international publication. The present work developed an accurate procedure for an in-depth study of dynamic behavior of transformer core including parameters like saturation, hysteresis and residual flux. The piece wise linear model for the magnetic characteristic of the iron core has been utilized in the analysis. A detail investigation was done both analytical and graphically to find the critical parameters for initiation and sustenance of ferrroresonance phenomena. The effect of variation of phase angle of the voltage on switching in the ferrroresonance phenomena has been investigated in details. True saturation curve of transformer represented by two terms fifth degree polynomial has been predetermined by a new method from the r.m.s saturation data supplied by the manufacturer. The method needs careful selection of two points on the r.m.s curve.The accuracy of the technique has been verified by the experimental results. The method described here has advantage over old method since the computation for obtaining the curve does not involve trial and error method. A computer aided method for optimizing number of segments necessary for the true saturation characteristic has been suggested. The dynamic behavior of transformer core has been analyzed from the data of two points of r.m.s saturation curve and no load loss. The weighted method of least squares is also applied for determining the expression for hysteresis loop including both the major and minor loops. The mathematical expression used also exhibits the hysteric property of increasing the loop area with increase of frequency of operation. The energy loss expression associated with hysteresis loop is derived from the expression suggested. A new approach has been made to incorporate dynamic models of representing the instantaneous saturation curve to get a composite model. The suggested method has 6 been utilized by optimizing it over a desired range. This technique is utilized to study dynamic behavior of transformer core at different switching angle, different remnant magnetism and different circuit parameters. The contributions made within its scope are given below. 1. For fixed value of resistance and capacitance and zero degree switching angle,the amplitude of transient current increases the magnitudes of applied input voltage increases. 2. The magnitude of jumps for the suddenly applied voltage is lower than that when applied gradually. 3. The dynamic core behaviour resulting ferrroresonance is more severe when the capacitance is increased with a fixed value of resistance in the system. 4. The effect of the increase in the value of resistance with a fixed value of capacitance under transient conditions is less than that in steady state condition. 5. Ferrroresonance leading to high voltages and high currents occurs aacross the transformer core for zero degree switching angles. The circuit is non resonant for switching angle of ninety degree 6. Development of a new method to determine an analytical expression for true saturation characteristic of transformers. 7. Development of new method to estimate the third harmonic flux linkage for correct analysis of transformer core behavior under transient condition. 8. The development of a new and accurate method by which hysteresis loop is determined for study of its dynamic behavior under ferroresonant conditions. 7 9. A new mathematical method hs been developed for analysis of transformer core behavior under transient conditions. This method reveals a better understanding to the problem then methods earlier. The report in this thesis has been organized in eight chapters. Chapter 1- provides a brief introduction to the ferrroresonance phenomena. Chapter 2-is devoted to the analysis of series ferroresonant circuits and various practical cases found in distribution network. It reviews the work of earlier workers and the suggested methods used in the present work. Chapter-3-deals with basic definition of the true saturation characteristic and methods used in deriving it.. Chapter 4-is devoted to the analysis of transformer core behavior including core loss. It has provided various methods to calculate core loss and compared with experimental results. Chapter 5 –is devoted to series ferroresonant circuit under transient condition. It discusses the general equations for the study of transients.. Chapter 6- is devoted to the system under investigation and various findings considering initial charge of capacitor, effect of input voltages and switching angles. It discusses the various experimental results. Chapter 7--is devoted to general conclusions and suggestions for future work in this field. Amiya Prasad Dash. Pratima Rath. 8 LIST OF PRINCIPAL SYMBOLS I - R.M.S. Current Ih - Loss Component of no load current Iμ - Magnetizing Component of no load current i - Instantaneous current ib - Base Quantity of Instantaneous current K - Slope of a Linearised Segment for I.C L - Inductance of the transformer winding N - Number of zones for r.m.s curve. N - Order of nonlinearity. R - Resistance of the Transformer winding Number of Segments for a Linearised I.C. S - Slope of Linearised Segments for R.M.S. curve. V - R.M.S. Voltage Vb - Base Quantity of R.M.S Voltage Vm - Maximum voltage V - No load loss α - Angle of the Harmonic Component λ - Instantaneous Flux Linkage λb - Base Quantity of Flux Linkage λm - Maximum Flux Linkage λ1m - Maximum flux linkage of fundamental component λ3m - Maximum flux linkage of third component w - Normal Angular Frequency wb - Base Angular Frequency A, B - coefficient of polynomial representing I.C in terms of voltage. A', B' - coefficient of polynomial representing I.C in terms of Flux linkage. A'1B'1 - Per Unit Coefficients Corresponding to A',B' C', D' - Coefficients of Polynomial Representing the Lose Part. C'1, D'1 - Per Unit Coefficient Corresponding to C' and D' 9 CHAPTER 1 INTRODUCTION The iron cored coil is a common nonlinear element in series ferroresonant circuit. The behavior of the transformer core under transient condition in ferroresonant circuit needs different approach then that in steady condition(2,3,4,7) The analysis of transformer core is very much desirable in transient simulation studies such as harmonic oscillations, self excitation, ferrroresonance phenomena, transformer core loss with and without residual flux, effect of switching angle and circuit parameter like capacitor etc(5,10,13,.17).It is also necessary to analyze for the predetermination of the problem and to find suitable methods to solve it in electrical distribution system(69). In the past literature many workers have tried to determine transient voltages by geometrical models, equivalent circuits, and electromagnetic models etc.In the year 1950 P.A.Abetti (2) first developed an electromagnetic model by taking care of the demerits of other models .He combined an equivalent circuit of capacitance and geometrical model for the self and mutual inductance. In the year 1970 L.O.Chua and K.A.Stromasmoe (4) used analytical expression for modeling the dynamic hysteresis loop. In the year 1972 A.Clerici (27)developd transformer model in response to the requirement of analog and digital computers for simulating power system transient. In 1975 S.N.Talukdar (1) has suggested an algorithm for converting saturation magnetic characteristics expressed in R.M.S.to instantaneous values. In 1980 S.Prusty and M.V.S.Rao(21.22.23) and again in the year 1982 S.N.Bhadra(25) have given various important direct methods to predict and predetermine magnetization characteristics of transformer including hysteresis.They have also developed a direct saturation curve to instantaneous curve and vice versa. Also in the literature Fourier series, power series and exponential functions were used for modeling to give a single expression to describe the whole saturation curve of a transformer(20,,30,33,34,35,38,42,43).S.N Bhadra(25) & S.Prusty et al (22,23)in 1984 have raised new expression to improve the modeling of dynamic hysteresis loop by including weightage factors to square method. In 1986 I.DMayergoyz (42) gave a mathematical model of hysteresis which is modified by S.Ray (66) and again in 1993 for prediction of hysteresis losses in single phase transformer. 10 In 1993 G.Bertotti et al (39) gave a modified dynamic model for a three phase power transformer core during transient condition. In 1995 F.D Leon (56) gave a simple representation of dynamic hysteresis losses in power transformer. S.K.Chakravarthy et al (72) extended it in that year for the three phase three limb transformer. A Fourier description model of hysteresis loop for sinusoidal and distorted wave forms including minor loops was given by Ismail A.Mohmmad etal in 1997(44). Torre E.D.(46) gave a new approach to magnetic hysteresis improving the work of M.A.Coulson et al (40) in Presiach's theory.G.W Swift(3,11) gave a new technique to study ferrroresonance problem. Many workers after this analyzed the ferrroresonance problem utilizing various aspects of transformer modeling (47, 4914, 15, 18) E.P.Dick and W.Watson (10) and S.S.Udpa et al (52) calculated the transient performance of transformer including core hysteresis. Iwaahara et al (12) and.Lamba et al (37) gave a new approach to the effect of circuit parameters on ferroresonant circuits and for its various solutions in the electrical networks. In 2000 M.R Iravani et al (14) gave a detailed picture of modeling and analysis guidelines for slow transient in the study of various magnetic core models in comparison with the laboratory test on a 33 KV voltage transformer. In the year 2006,Li,H. et al(15) gave a detailed picture of dynamic core behavior in their paper on chaos and ferrroresonance.For analysis of transient phenomena.Afshin Rezaei-Zave et al in 2007(16,18) gave detailed account of analysis of ferrroresonance modes in power transformers using Preisach type magnetic inductance. In 2008, the same group of workers namely Afshin R-Zave et al (17) gave a modified version to get an accurate hysteresis model for ferrroresonance analysis of a transformer in series circuits. The aim of the present work is to develop an accurate procedure for study of transformer core behavior including various losses like saturation,hysteresis and eddy current for the study of series ferroresonant circuits under transient condition. Computation of critical voltages for various circuit parameters have been analyzed by considering instantaneous saturation curve as piecewise linear. All the analysis have been carried out considering switching angles, residual flux, capacitor charge etc.The present work finds computational techniques to accurately predict and predetermine transient 11 over voltages in various electric network at no load condition and to provide suitable steps to solve it in distribution network. Various computer aided methods have been proposed to study the effects carefully and suitable methods have been proposed to derive saturation characteristic in piecewise linearised segments by optimizing it over a desired range58, 59, 60, 62). For the loss part polynomial approximations of cubic and quintic orders have been considerd.The technique is utilized to study transient behavior of the circuit at different switching angle .Camera fitted oscilloscope has been proposed to take all the photographs of the core behavior under transient condition. The various computational techniques used for transient simulation studies are supported by experimental observations in laboratory condition. *********************************************************************** 12 CHAPTER 2 ANALYSIS OF SERIES FERRORESONANT CIRCUIT 2.1 Preliminaries: Ferroresonant is special types of jump phenomenon associated with electrical circuits containing a linear capacitor and a nonlinear inductor with or without any other element present in the circuit (fig 2.1).The magnetic core of the voltage transformer behave as nonlinear inductor. Due to interaction between linear capacitor and nonlinear inductor, resonance occurs. For certain circuit parameters and forcing frequency, when a slight variation in one of them occurs, the signal is suddenly enhanced somewhere in the circuit. There are many situations found in electrical system networks in which each case of the above circuit parameters can give rise to the ferrroresonance phenomena. The following sub sections discus some important situation in which ferrroresonance occurs. 2.2 Power system ferrroresonance: Ferrroresonance being a forced oscillation in a non-linear circuit, it is necessary in order to study it ,to define the excitation voltage of the source delivering the energy which maintains the phenomenon. The oscillation or resonance occurs between a linear capacitance and a nonlinear inductance. The capacitance can be due to a large number of capacitive elements. Similarly the nonlinear inductance can be that of a single element for example the magnetic core of a voltage transformer or it may have the structure of a three phase power transformer [69]. 2.2 Power System Ferrroresonance: 2.2.1 Single-phase Ferro-resonance on a voltage transformer connected to a highvoltage line, disconnected but running alongside another energized line: This effect can occur when two high-voltages lines are strung on the same pylons but are operated at different voltages like for example 150 and 70 kV.[fig 2.2].As shown in the figure line A at the higher operating voltage is energized, line B disconnected at both ends. Only a voltage transformer Xs is still connected to line B and possibly a current transformer and a lighting arrester. The potential on one conductor RB of the de-energized line depends on the capacitances between these conductors on the one hand and earth and the energized wires on the other 13 .Considering from the terminals of the voltage transformer, one can reduce the lines to a single-phase source in series with a capacitance by applying the Thevenin theorem. He same procedure is repeated for each phase of the disconnected line.It is established that Ferro-resonance occurs only exceptionally in the circuits. The possibility of its occurrence depends on the supply voltage, the value of the capacitance and the magnetic characteristics of the non-linear element. 2.2.2 Single-phase Ferro-resonance between voltage transformers and the h.v./m.v. capacitance of a supply transformerThe phenomenon can occur with a supply transformer where the h.v. neutral is insulated from earth although the h.v. system is earthed at other points. The m.v. also insulated from earth is connected to a set of three voltage transformers [fig 2.3] but does not supply any load. Following a fault to earth on the h.v. system on the supply side of the transformer, its h.v.neutral potential can be raised temporarily to a high voltage to 70 percent maximum of the phase to earth voltage. The circuit formed by this voltage En, the capacitance Cn and on each phase the capacitance Cn in parallel with XS can thus be brought to a state of fundamental Ferro-resonance giving rise to an over voltage on the m.v. system. After clearance of the fault on the h.v. system, the Ferro-resonance condition may be maintained by the normal voltage existing on the h.v. neutral point. The normal condition is generally returned by greatly increasing the zero-sequence capacitance C0 by the connection of a cable to a load on the m.v. side of the circuit. 2.2.3 Single-phase Ferro -resonance between a voltage transformer and the capacitance constituted by an open circuit breakerThe phenomenon can occurs with a circuit-breaker having a number of interrupter heads carrying a small capacitor in parallel for voltage distributor [fig 2.4].On the supply side of the open circuit breaker there is a set of busbars.On the other side only a voltage transformer and an open isolator leading towards a line. There may be in addition a current transformer and a lighting arrester. The Thevenin theorem is used to reduce the linear circuit at the terminals of the voltage transformer to a 14 voltage in series with a capacitor. This voltage becomes zero and the phenomenon becomes impossible when the capacitance of the open circuit breaker becomes negligible compared with the zero-sequence capacitance of the system like for example when the isolator which follows the system is closed on an h.v. line. 2.2.4 Three-phase Ferro-resonance with voltage transformers connected to a system with insulated neutral and very low zero-sequence capacitanceThis concerns the classic phenomenon of Ferro-resonance and to one to which the majority of publications[69] are devoted [fig 2.5].The figure gives only one example of the situation where the phenomenon can occur, another situation is for example where the voltage transformers are connected to the terminals of an alternator. The essential conditions are that system be one with an insulated neutral that the three voltage transformers be connected between phase and earth and that the capacitance C0 between phase and earth be very small which is satisfied when its impedance is of the same order of magnitude as the impedance of the voltage transformers. If the load of the voltage transformers is ignored, the circuit can be reduced to its simplest expression .In this case the voltage source is represented schematically in star connection. There remains in each phase only the non-linear inductance XS of the voltage transformer in parallel with C0. the phenomenon is three-phase and cannot be reduced to single-phase circuits. For example, it becomes impossible if the two neutral points are earthed that is the neutral of the power system is earthed. The fundamental Ferro-resonance as well as the sub-harmonic and higher harmonic Ferro-resonance can occur in this configuration depending upon the relative value of the impedances of XS and C0 .There is however an important difference versus a single phase circuit. In the later there appears a sub-harmonic or a higher harmonic which is an exact multiple or submultiples of the supply frequency. In three phase Ferro-resonance there appears a frequency which is near harmonic but slightly different from it so that a beat phenomenon is obtained. It is said generally that the phenomenon only occurs on an unloaded system which is correct insofar as the connection of a load normally increases the zero-sequence capacitance to such an extent that the phenomenon becomes impossible. 15 2.2.6 Ferro-resonance with an unloaded power transformer supplied accidentally on one or two phasesIf between the system and an unloaded transformer or a very lightly loaded one, one or two phases are interrupted by a fuse blowing, the operation of a single-pole circuit, the non-simultaneous operation of the contacts of a three-phase circuitbreaker or again a conductor breaking, very high voltages can occur on the open conductor or conductors and this takes place on the transformer side.In addition reversal of phase rotation is possible at the secondary terminals of the transformer [69]. The capacitance, positive-sequence and zero-sequence, of the connection, cable or line, between the power system and the transformer plays an essential part [fig 2.6].as shown in the figure a star-delta transformer with three limbs is shown. The three elements the primary and secondary winding connections and the structure of the core play important part .The same situation is also encountered with three single-phase transformers. The phenomenon generally occurs when a primary winding of the transformer is insulated from earth but with the neutral earthed. 2.3 Review of work done by G.W Swift and R. Javora etal: G.W.Swift [3] has in his paper has studied the power transformer core behavior under transient condition. In the paper he has stated when analyzing electric utility networks it is sometimes necessary to stimulate the dynamic behavior of a transformer or reactor, that is, to simulate the time dependent relationships among current, voltage and flux for a winding on an iron core. Three examples of problems in which nonlinear effects must be included are ferrroresonance, subharmonics and transformer inrush current. The qualification "unloaded" is used because this is the condition most likely to cause Ferro-resonance or subharmonics.An unloaded transformer has one winding open-circuited and therefore equivalent to a reactor for calculation purposes. The term iron core referred to a laminated core of grain-oriented silicon-iron sheet, universally used in modern power transformers and reactors. As stated by Swift there are three non-linear effects introduced by iron cores. They are magnetic saturation, hysteresis and eddy-currents. These three 16 effects were carefully distinguished .In the literature it is seen that some consider saturation and hysteresis only; some consider saturation and eddy-current effect only. There are few papers which consider all three for only in specific cases like in isotropic iron and not in the study of transformer core behavior under transient condition. Hence He has shown that if hysteresis is to be considered in a particular circuit analysis, then eddy-currents must also be considered because they represent a larger effect and a linear modeling of the eddy-current effect is very accurate for commercial power transformers. Three non-linear effects: Of the three effects saturation is the most predominant not found in linear systems. The factor which distinguishes the saturation effect from the other is that energy loss is involved in the others, that is energy is dissipated as heat loss in the cases of hysteresis and eddy-currents. Saturation it self does not introduce loss. Even though saturation is the predominant effect, t is sometimes necessary to include loss-associated effects as for example in cases where the total system loss appears to be a major determinant as to whether or not sub harmonic oscillations will be self-sustaining. Display of losses: The voltage current relationship ∫e dt and i will provide the loss per cycle. The area bounded by the curve considering ∫e dt along Y axis and I along X axis will provide the loss of the transformer core per cycle given by W = ∫0T p dt (i) Where p is the power being dissipated and T is the time for one cycle of the periodic voltage, current or flux. If we take ∫e dt = y for notation convenience then the area enclosed by the contour is given by A=∫ I dy = ∫(dy/Idt)dt = ∫Ie dt = ∫p dt (ii) Comparing this with (i) it is seen that A=W that is the loop area is equal to tha energy loss per cycle. Considering two cases (i) a resistor and (ii) an iron cored coil with negligible winding resistance.If sinusoidal voltage is applied in each case ,the iron cored coil loss cycle is recognizable as a hysteresis loop and this is to be expected since 17 e= N A (dB/dt) or B= (1/NA) ∫e dt Where N is the number of coil turns,B is the effective core flux density, and A is the effective core cross-sectional area and the current I is proportional to the magnetic field intensity within the core. Eddy-current effect: The shape of the contour is dependent on the rate at which the contour is traversed.For very slow traversal of the loop,the loss can be termed as pure hysteresis loss and is attributable to domain wall movements back and forth across crystal grain boundaries ,non magnetic inclusion and imperfections.Increasing the frequency increases the loss per cycle.Any increase in loss above the value at zero frequency has been attributed to "eddy-current effect", and for modern commercial grain-oriented silicon-iron sheet this effect accounts for about three times as much loss as does the pure hysteresis.It is seen in the literature[21,23] on domain wall motion and shape indicate that the pure hysteresis effect is frequency dependent. The total core loss is divided in to frequency-dependent part and a nonfrequency-dependent part.The following expression [ ] gives the value of magnetic field intensity due to eddy-currents He= K cos(1-sinwt) [900 < wt < 1800] Where K is a constant for a particular core and w is the radian frequency of an applied cosine voltage e . Let He be proportional to a component of coil current Ie associated with it. We now have e = Em cos wt giving ∫e dt = (Em/w)sin wt Where Em is rthe peak value of the coil voltage e and the constant of integration is zero in the steady state.Also Ie = K' cos wt (1-sinwt) where K' is a constant incorporating K and the linear proportionality between He and Ie . The graph between ∫e dt and Ie gives the loss cycle due to eddy-current. 18 Hysteresis Effect: The modeling of hysteresis effect is more complex.The pure hysteresis loss is only about one-third of the other loss like eddy-current loss [ ].The saturation characterstic is given by the relation I0= α∫e dt + β[∫e dt]5 Where α and β are constants and I0 is the mean value current of the hysteresis loop family of curves. Hence Swift concluded that when the nonlinear aspects of an inductor (transformer or reactor) are to be considered in a circuit theory analysis, it is important to include the eddy current effect when the pure hysteresis effect is also included since eddy-currents cause more loss than does hysteresis in modern power transformer core under transient condition. The eddy-current effect is approximated in a linear way. Demerits: In the paper Swift has considered the three effect of the transformer core has been considered separately which in practical cases need simultaneous consideration as all these occurred together wlile analyzing power system network to study ferro-resonance phenomenon. R.Javora et al paper [6] is an improvement over the paper of Swift in that they have considered a small resistance in parallel to the iron core inductor. They have discussed the phenomenon in the following ways: Javora et al have discussed the cases in which a resistor is used in parallel with the inductor to account for the core loss. According to them a lot of articles concerning ferrroresonance phenomenon in electric power distribution systems consider a single-value resistor connected in parallel with a nonlinear inductor to represent core losses of the of the transformer under study. Such a resistor cannot properly describe the behavior of transformer in the saturated area. There better and more complex model of the transformer core losses is necessary. They have recommended for further improvement of the ferrroresonance studies in electric power systems by considering a dynamic behavior of transformer core losses. 19 They have compared the results by using static (single-value resistor) and dynamic (nonlinear resistor) representation of core losses .Javora et al have shown that by employing only a static description of core losses there is a higher level of instability for solutions. Measurements by them shows higher damping effect and lower level of instability in dynamic representation of core than by using static representation. Demerits: Javora et al have not introduced the most accurate model of transformer. The proposed method provides only one possible way for a qualitative description of the effects of magnetic hysteresis in magnetic circuits. and the consequences of assuming the static and the dynamic representation of core losses. 2.4 Conclusion: The present thesis has taken in to the merits and demerits of earlier workers and more particularly the work of Swift and Javora et al and developed a new mathematical technique to calculate the transformer core loss by putting a small resistance in parallel with the iron core inductor.This technique is found to yield better result in the study of transformer core loss and transformer core behavior under transient conditions.The methods used by Swift and Javora et al needs more in field test and tedius calculation where as the suggested method in the thesis is more straight forward , analytical and easy to implement in the electrical distribution system. ************************************************************* 20 CHAPTER 3 TRUE SATURATION CHARACTERISTICS 3.1 Preliminaries: The true saturation characteristic of magnetization of iron core coil or transformer behaves quite differently in ferrroresonance condition then that in normal condition.Its proper determination under dynamic condition is a challenge to all workers in this field as the core flux linkage is a nonlinear function of the current across it.The true saturation characteristic of a transformer or an iron cored reactor gives the relationship between peak values of flux linkage (λ) and the magnetizing current (i) when core loss is neglected. This is shown in fig (3.1).The symmetrical nonlinear characteristic can be represented by a polynomial i= a1λ+ a3λ3 + a5λ5 +……..+ anλn (3.1) Where n is an odd integer and a1, a3, a5…….. an are constants. It has been seen by many workers (9,13,69 ) that two term polynomial is sufficient to represent the magnetizing characteristic for power system transient studies. Therefore the equation for true saturation characteristic of a transformer is i= a1λ+ anλn for n= 5, 7,9,11 (3.2) 3.2 Meaning of the true saturation characteristic: The saturation characteristic of a transformer is in the R.M.S. form supplied by the manufacturer.But the R.M.S. form of saturation characteristic is not useful directly to work with the study of transformer core behavior. In general the current and flux linkage relationship of an iron cored transformer is a nonlinear and multivalued .There may be several flux linkage values corresponding to one current value and vice versa. It is not practicable to tackle and use them for core studies during dynamic condition. To simplify them to a single valued functional relationship between the flux linkage and the magnetizing current can be used.This is the curve relating the d.c. flux linkage and the corresponding d.c. magnetization current when the core is in demagnetized condition and is known as true saturation curve. The true saturation characteristic is very much useful for study of saturation effect of the core material and to calculate the total core loss .It may be 21 obtained experimentally using sinusoidal a.c. voltage for energization of a transformer. The peak currents corresponding to various peak voltages are measured with the help of a C.R.O. shown in fig (3.2).But this method is not convenient for transformers which are already in service in the network. Hence it is desirable to develop some methods to derive the characteristic from the R.M.S. saturation data supplied by the manufacturer. 3.3 Assumptions for the saturation characteristic: The true saturation characteristic of a transformer can not be directly obtained from the readings given by R.M.S.meters used in the test. The characteristic as shown in fig( 3.1) is obtained by joining the tips of magnetization characteristic without considering the losses in the core. Considering a transformer for which applied voltage V produces current I and flux linkage λ , we get V= (d λ/dt) +R I (3.3) Where t denotes time and R is the resistance that simulates the electrical energy losses in the transformer.When the loss is neglected equation (4.3) becomes V= (d λ/dt) (3.4) Let λ = λmsin wt (3.5) From equations (3.4) and (3.5) , we get Vm = λm.w Or V = (λmw)/sqrt 2 (3.6) From equation (3.6) it is clear that λm is directly proportional to the applied voltage V at a given angular frequency w. As there is functional relationship between the maximum flux linkage of the winding of a transformer and the corresponding maximum value of no load current, the curve relating the two quantities can be obtained with some extra arrangements rather than with only R.M.S. meters. The same characteristic may also be predetermined from the R.M.S. curve data. Therefore the true saturation characteristic should satisfy the following assumptions (i) the core are in a demagnetized state (ii) The core losses are negligible. 3.4 Conclusions: The saturation curve data obtained from the manufacturer is of the R.M.S. form. This data is most reliable for study of various transformer core behavior than is obtained from test result. The experiment to be performed to obtain such data is not feasible as all 22 the practical transformers have been in the distribution network.Hence it is suggested in the thesis to use manufacturer's data in the study related to transformer core behavior from the available manufacturer's data. Predetermination of the phenomena and taking suitable precaution to avoid the occurrence such ferrroresonance problem in series ferroresonant circuits are more important. *********************************************** 23 CHAPTER 4 ANANLYSIS OF TRANSFORMER CORE BEHAVIOR INCLUDING CORE LOSS 4.1 Preliminaries: In the case of dynamic hysteresis loop of transformer, it can be identified that it has two symmetrical parts. The first part is the true saturation characteristic of a transformer which is represented as gob in fig (4.1) and which is hereafter called 'true saturation part'. The saturation part is the locus on the mid points (abscssae) of the hysteresis loop and represents the ideal magnetization characteristic of the transformer,.The second part is the 'loss part' because it is the main part to contribute proper shape and area to the hysteresis loop. The periphery of the hysteresis loop, which is same as the actual hysteresis loop is obtained by adding or subtracting 'loss part' to the 'true saturation part'. Usually for modern transformers, true saturation characteristic is approximated by a fifth order polynomial given by I=A'λ+B'λ5 (4.1) Where λ =λmsin θ (4.2) and θ=ωt (4.3) The nature of the loss part is that it is maximum when the true saturation part is zero and it is zero when true saturation part is maximum. Hence the loss part is represented by f(λ) or g(λ, λ') where λ'=dλ/dt 4.2 Expression for the hysteresis loop: The hysteresis loop is represented by an addition or subtraction of thee loss part to the true saturation part. Incorporating a plus or minus sign implicit in f (λ') or g(λ, λ'), the mathematical expressions for the hysteresis loop are I=A' λ+B' λ5+f(λ') Or (4.4a) 24 I=A' λ+B' λ5+f(λ,λ') (4.4b) For the cubic order f(λ') approximation of the loss part f(λ')=C'(λ)+D'(λ')3 (4.5a) =C(λm cos ωt)+D(λm cos ωt)3 (4.5b) Where C=C'ω and D=D'ω3 Substituting eqns(4.5) and eqns(4.2) in eqn 4.4a and simplifying, we have I=SQRT [(A' λm+5/8B' λ5m)2+(C λm+3/4D λ3m)2] Sin (ωt+α1) +SQRT [(5/16 B' λm5)2+ (D/4 λm3)2] Sin (3ωt+α3) + (1/16B' λm5) sin5 ωt (4.6a) Or I=Im1sin (ωt+α1) + Im3 sin(ωt+α3)+ Im5 sin(5ωt) (4.6b) Where α1=tan-1 [C λm+3/4D λm3] /[A' λm+5/8B' λm5 ] α3=tan-1 [D/4 λm3] / [-5/16B' λm5 ] (4.7) And A', B', C and D are the constants to be evaluated. The r.m.s. current is given by I0=[1/ sqrt(2)]sqrt[(Im12+ Im32+ Im52)] =sqrt[(Iμ2+ Ih2)] (4.8) (4.9) Where Iμ and Ih are the r.m.s. magnetizing and hysteresis loss components of the no load current which are obtained either from manufacturers data or no load test on the transformer. The magnetizing components of no load current are calculated as follows: Say I0 and w0 are the no load currents and loss respectively of a given transformer, when a voltage of V volts is applied to it. The loss component of no load current of a transformer at the given voltage is Ih= w0/V (4.10) Then,the magnetizing component of no load current is given by Iμ=sqrt [(I02-I h2)] (4.11) From equation 4.6a and 4.9.separating the components, we have Iμ=[1/sqrt (2)]/sqrt[(A' λm+5/8B' λm5)2+(5/16B' λm5) 2 +(1/16B' λm5) 2 (4.12) 25 And Ih=[1/sqrt(2)]sqrt[(C λm+3/4D λm3)2+(D/4 λm3 ) 2 ] (4.13) The expressions for r.m.s. magnetizing and hysteresis loss components of current when hysteresis loop has loss part approximation by(1) quintic order f(λ') cubic order g(λ,λ'),and quintic order g(λ,λ') . 4.3 Hysteresis loss: The energy loss during each cycle associated with the hysteresis loop is equal to the area of the loop and is W=∫idx (4.14) For the loss part approximation by cubic order f(λ') using eqns.(4.14.)(4.6a) and (4.2) and simplifying W=π λm2(C'ω+3/4D' ω3 λm2) joules/cycle (4.15) For the loss part approximation by cubic order f(λ') W=π λm2(C'ω+5/8D' ω5 λm4) joules/cycle (4.16) Similarly for loss part approximation by cubic g(λ,λ') W=π λm2(C'ω+D'/4 λm2)ω joules/cycle (4.17) Similarly for loss approximation by quintic g(λ,λ') W=π λm2(C'+D'/8 λm4) ω joules/cycle (4.18) From eqns 4.15 through 4.18, it is evident that the loop area increases with the increase of frequency of operation. 4.4 Suggested methods: Two point data method: The hysteresis loop is represented by a fifth order polynomial expression and with the help of eqns (4.4a),(4.5 )and (4.2) for an approximation of the loss part by cubic order f(λ'), it is described as I=A'(λmsinθ) +B'(λmsinθ)5+C λmcosθ+D (λmsinθ )3 (4.19) The coefficients of eqn. (4.19) are to be evaluated in order to model the transformer magnetization characteristic including hysteresis loss. For the purpose,of the r.m.s. saturation current along with no load loss is used. The method of evaluation of the coefficients requires only two points of the data and it is as follows. 26 The hysteresis loop consists of two parts (4.12) and (4.13.) derived by the use of eqn (4.4a) for the approximation of the loss part by cubic order f(λ') are used for the evaluation of the coefficients A',B',C and D for the purpose, the equations are modified as aA'2+bB'2+cA'B'=d (4.20) And a'C2+b'D 2+c C D = d' (4.21) Where a = (1/2) λm2 b= (126/512) λm10 c= (5/8) λm6 d = Iμ2 (4.22) And Where a' = (1/2) λm2 b'= (10/32) λm10 c'= (3/4) λm6 d' = Ih2 (4.23) The coefficient A' and B' for finding out the true saturation part is evaluated using equation (4.20) using two point data of magnetizing component of no load current at two different voltages on the R.M.S. curve. The coefficients C and D can also be found out with the help of equation (4.21) using the data of loss components of no load current at two different voltages on the R.M.S.curve. Both the equations are nonlinear in nature and the coefficients either A' and B' or C and D at a time can be computed using two point data. Multi point data method: It is clear from equations (4.20) and (4.21) that only two unknown coefficients either A' and B' or C and D can be evaluated by using a corresponding R.M.S. saturation data and so the predetermination of magnetization characteristic of a transformer including hysteresis is possible with two point data but for better accuracy the entire no load test data may also be used .However the multipoint data can not be used for the evaluation unless a numerical algorithm like least squares method used by many workers[1,25,29,33 ]. The evaluation of the coefficients can be done by the least squares method using multi point data. The transformer magnetization curve can be modeled more accurately by 27 including the hysteresis and evaluating the coefficients A',B',C' and D using multi point data instead of two point data of the no load test. In the case of modeling with multipoint data the coefficients are found by a method of minimization of the sum of the squares of the errors at various data points of the saturation curve .The error it self cant become proper basis for accounting the derivations over the entire range of the curve, the per unit error at a data point is made as the basis for finding the modeling expression (22, 23) For the purpose, the sum of squares of the per unit errors at different data points is reduced to a minimum by method of least squares. Thus while calculating the per unit error, a weighting factor, varying at different points of data, described by a function of r.m.s. current automatically creeps into the calculations. This method of calculation is the weighted method of least squares. In this case the data of the set {V, Iμ} at various voltages of the R.M.S. curve is used for computing the coefficients A' and B' and similarly the data for calculating the coefficients C and D of the loss part of magnetization curve is the set {V,Ih} at different voltages of the R.M.S. curve. The equations (4.10 ) and (4.11) are used for these purpose .The unweighted and weighted method of least squares have been used for the calculation of the transformer core behavior and for the calculation of the coefficients to study the magnetization characteristic of transformer . Unweighted method of least squares: In this method the R.M.S. saturation data that is one of the sets {V, Iμ} and {V,Ih} as required is converted in to per unit data on some base quantity with usually the rated value. By this unweighted method of least squares the error or residual at each data point is considered.The sum of the squares of errors for all the data points of the R.M.S. curve is minimized by the method of least squares. Let the true saturation part of the magnetization characteristic including hysteresis be expressed as Iμ = A'λ + B'λ5 (4.24) I1μ = A1'λ1 + B1'λ15 (4.25) But I1μ = Iμ/ Iμb and λ1 = λ/ λb with λb = sqrt (2)Vb ) / w 28 Where w = 2πf and Iμb = A'λb + B'λb5 with λb and Iμb the base quantities of of flux linkages and magnetizing current respectively. The coefficients of equations (4.24) and (4.25) are related as follows A1' = [A'λb / A'λb + B'λb5] (4.26) B1' = [B'λb5/ A'λb + B'λb5] Substituting λ= λm sin wt in equation (4.24) and simplifying we get Iμ = sqrt [(λm2 A'2)/2 + (5/8) λm6 . A'.B' + (63/256) λm10 B'2] (4.27) Putting w λm = sqrt (2)V in equation (4.27) we get (V2 A'2/w2) + 5 V6 A' . B'/w6 ) + 63V10 . B'2/w10 - Iμ2 = 0 (4.28) A relation between V1 and I1μ can be derived p B1'2 + q B1' + r =0 (4.29) Where p = (63/128)V110 – (5/4) V16 + V12 –(31/128) I1μ2 (4.30) q = (5/4) V16 - 2 V12 + (3/4) I1μ2 r = V12 - I1μ2 The entire R.M.S. data for true saturation part expressed in per unit values that is the set {V1, I1μ} can be used to evaluate the constants B1' of the equation (4.29) by the method of least squares. Applying the method of least squares the equation (4.29) becomes d/d B1' (p B1'2 + q B1' + r)2 = 0 that is 2 B1'3 Σn pi2 + 3 B1'2 Σn pi qi + B1' Σn (qi2 + 2pi ri)+ Σn qi ri = 0 (4.31) Where n is the number of points chosen from the R.M.S. data. The positive real root less than 1 is the required solution of the equation (4.31).The other two roots are in general complex. Substituting B'/A' = K in equation (4.28) we get A'2ΣVi2 /w2) + 5K Vi6 /w6) + (63/8)K2 Vi10 . B'2/w10 = Σ nIμ i 2 (4.32) Where (Vi, Iμ i) is a point on the R.M.S. saturation curve. A' and B' are obtained by using equation (4.32) .Then A and B are also calculated. The procedure for the evaluation of C and D with the data of the set {V,Ih }by the unweighted method of least squares .By using equations (4.4) and (4.6) the loss part of the hysteresis loop is calculated by using ih= C' λ' + D' (λ')3 (4.33) 29 By using λ' = (d λ/dt) = λm w cos wt (4.34) Substituting equation (4.34) in equation (4.33) and solving we get ih = [C λm +( 3/4 )D λ3m]cos wt +[ (1/4)D λ3m] cos 3 wt (4.35) The R.M.S. value of the loss component of no load current is ih =sqrt [{C λm +( 3/4 )D λ3m}/sqrt 2]2 + [ { (1/4)D λ3m}/sqrt2]2 = sqrt [(1/2) (C2 λ2m + (5/8) D2 λ6m + (3/2) λ4m] (4.36) Substituting C=C'w and D= D'w3 and λm=sqrt(2)V/w in equation (4.36) I2h = C' 2V2 + (5/2) D' V6 + 3 C' D' V4 (4.37) The base quality of flux linkage, the loss component becomes ihb = C' λ'1 b+D'(λ'1 b)3 (4.38) Dividing the equation (4.31) by ihb we get i1h = C1 ' λ'1 +D1 '(λ'1)3 (4.39) The above equation describes the per unit based representation of the loss part of the magnetic characteristic A relation between V1 and I1h is derived in quadratic form of D'1 as given in equation (4.38) pD1' 2+ q D1' + r = 0 (4.40) Where p= (5/8V1 6-(3/2) V14 + V12-(1/8) I2 1h q= (3/2) V1 4-2 V12 + V12+ (1/2) I2 1h r= V12- I2 1h The data for loss component of no load current can be used to evaluate constant D1' By least squares method. Minimising the sum of the squares of the errors given in equation (4.40) we get 2 D1'3Σn pi2 + 3 D1'3Σnpi qi + D1'Σn (qi2+ 2pi ri)+ Σn qi ri =0 (4.41) Where n is the number of points chosen from the data of R.M.S. voltage versus loss component of no load current. The positive real root less than 1 is the required solution of equation (4.41) Substituting (D'/C') =K in (4.41) C'2Σn (Vi2 + (5/2) K2V6i + 3 K V4i)= Σn I2 hi = 0 (4.42) 30 Where (Vi, I hi) is a point from the data of voltage versus loss component of no load current. The coefficients C, D, C' and D' are obtained from equations (4.42) The loss part or the instantaneous value of loss component of no load current I h can be assumed to have the other approximation (i) quintic order f(λ),(ii) cubic order g (λ, λ'). Weighted method of least squares The weighted method of least squares yields more accurate true saturation curve than that of unweighted method of least squares. For representation of magnetization curve of a transformer including hystresis, the coefficients A', B', C and D are to be evaluated from the r.m.s. saturation data and no load loss. By applying the weighted method of least squares, the evaluation of the coefficients A', B', C' and D are obtained more accuarately than the unweighted method of least squares. For the method of evaluation of coefficients A' and B' by the weighted method of least squares, eqn (4.29) is to be modified conveniently. For bringing the expression in to a convenient form so that the weighting factor can be incorporated, the eqn (4.29) is written in a form to represent per unit error at a point as Є'= [pB12+qB1+r'-I'2μ ]/ I12μ (4.43) Where p and q are given by eqn 4.40 and r'=V'2 Minimizing the sum of the squares of the per unit error given by equation (4.43)by the method of least squares, we have 2 B1'3Σn pi2/I' 4 μ1+ 3 B1'2Σnpi qi/ I' 4 μ1 + B1'Σn (qi2+ 2pi ri)/ I' 4 μ1+ Σn qi ri / I1 4 μ1=0 (4.44) Where n is the number of points chosen from the data R.M.S. voltage versus magnetizing component of no load current .The eqn(4.44) contains a weighting factor 1/I12μ1 that changes automatically through out the range of the data. The positive root less than 1 is required solution of eqn 4.44.The other two roots in general are complex.eqns are useful in calculating the ratio B'/A' say K. Substititing K in eqn (4.32)A' is evaluated. Then the coefficients A and B are obtained.. For the evaluation of C and D by the weighted method of least squares, the equation (4.40) is modified to represent the per unit error at a given data point as 31 Є'= pD'2+qD'+r'-I'2h/ I'2h (4.43) Where p and q are given by eqn(4.40) and r'=V'2 Applying the method of least squares to eqn 4.43, we obtain 2 D1'3Σn pi2/I1 4 h1+ 3 D1'2Σnpi qi/ I14h1 + B1'Σn(qi2+ 2pi ri)/ I1 4 h1+ Σn qi ri / I1 4 h1= 0 (4.44) Where n is the number of points chosen from the R.M.S. data versus loss component of no load current. The equation contains a weighing factor 1 / I1 4 h1 that automatically changes through out the range of data. The positive root less than 1 is the required solution for D1' .The knowledge of this will help to find out the other coefficient C' .Thus all the coefficients of the loss part C, D,C' and D' are evaluated. The instantaneous value of loss component of no load current can also be represented by other approximations like quintic order and for cubic order. 4.5 Comparison of suggested methods: The hysteresis loop currents computed for the four different forms of approximations of loss part by the three methods are compared with the measured values at 200V,230 V and 260 V in tables (4.2) (4.3) and (4.3) .The computed hysteresis loop currents obtained for quintic approximation by all the three methods suggested and the measured one at the operating voltage 230 Volts are shown for graphical comparison in fig [4.2 ].Also the computed current wave form obtained for quintic approximation of the loss part by all the three methods suggested and the measured one at the same voltage are presented for comparison in fig[4.3 ] . In order to find the accuracy of the hysteresis loop currents obtained with different approximations by the three methods suggested, R.M.S. error in the loop currents has been computed and presented in tables (4.2),(4.3) and (4.4) It is found from the comparison that the weighed method and the two point methods give one for the study of transformer core loss and its behavior under transient condition. 32 4.5 Experimental observations: In order to apply the suggested methods to predetermine the magnetization characteristic including hysteresis, a laboratory type single phase transformer rated at 3kVA, 230/230V, 50 Hz has been selected. The readings by varying the voltage across the transformer up to 300 Volts are recorded. The magnetizing and the hystersis loss components of no load current at different voltages are calculated and the data thus obtained is used to predetermine the coefficients A', B, C and D. Table 4.2a .Measured and computed currents (two point method) at 200 V: Angle in Flux Measured Computed current Degree linkage in Current Cubic Quinticf(λ') Cubic Wb.turns in f(λ') in A In Ampere g(λ, λ') λ') in Ampere Quintic Ampere 0 0 0.15 0.157 0.159 0.158 0.16 18 0.223 0.21 0.228 0.227 0.2265 0.23 36 0.423 0.27 0.285 0.285 0.286 0.28 54 0.583 0.35 0.356 0.355 0.356 0.355 72 0.69 0.43 0.427 0.427 0.427 0.43 90 0.72 0.465 0.43 0.43 0.4305 0.432 108 0.69 0.34 0.3288 0.331 0.327 0.327 126 0.583 0.165 0.168 0.169 0.166 0.168 144 0.423 0 0.027 0.0277 0.027 0.0274 162 0.223 -0.1 -0.077 -0.076 -0.075 -0.074 180 0 -0.14 -0.1574 -0.1582 -0.1574 -0.1582 2.06 2.07 2.07 2.08 R.M.S. Error in% g(λ, 33 Table 4.2b.Measured and computed currents (two point method) at 230 V: Angle Flux Measured in linkage in Current Cubic Quinticf(λ') Cubic Wb.turns in f(λ') in A In Ampere g(λ, λ') in Ampere Degree Computed current Quintic g(λ, λ') Ampere 0 0 0.226 0.2265 0.227 0.226 0.227 18 0.32 0.3 0.335 0.334 0.329 0.328 36 0.61 0.426 0.475 0.474 0.476 0.475 54 0.84 0.86 0.82 0.82 0.827 0.832 72 0.98 1.34 1.3 1.3 1.31 1.3 90 1.04 1.6 1.5 1.5 1.51 1.5 108 0.99 1.1 1.16 1.16 1.15 1.15 126 0.84 0.5 0.55 0.55 0.54 0.54 144 0.61 0.1 0.098 0.099 0.096 0.098 162 0.32 -0.14 -0.112 -0.111 -0.107 -0.105 180 0 -0.226 -0.227 -0.228 -0.227 -0.228 4.65 4.65 4.4 4.34 R.M.S.Error % 34 Table 4.2c.Measured and computed currents (two point method) at 260 V: Angle Flux Measured n linkage in Current Cubic Quinticf(λ') Cubic Wb.turns in f(λ') in A In Ampere g(λ, λ') in Ampere Degree Computed current Quintic g(λ, λ') Ampere 0 0 0.25 0.256 0.25 0.256 0.258 18 0.36 0.35 0.38 0.381 0.36 0.35 36 0.69 0.6 0.597 0.595 0.59 0.596 54 0.945 1.2 1.21 1.21 1.22 1.23 72 1.11 2.1 2.11 2.11 2.12 2.13 90 1.17 2.5 2.52 2.52 2.52 2.53 10 1.11 1.8 1.95 1.95 1.94 1.94 126 0.945 0.9 0.91 0.91 0.89 0.89 14 0.69 0.15 0.167 0.168 0.16 0.167 162 0.36 -0.1 -0.127 -0.128 -0.12 -0.118 180 0 -0.25 -0.255 -0.257 -0.26 -0.26 4.93 4.9 4.59 4.4 R.M.S.Error % 35 Table 4.3 a. Measured and computed currents (unweighted method of least squares) at 200 V: Angle Flux Measured in linkage in Current Cubic Quinticf(λ') Cubic in f(λ') in A In Ampere g(λ, λ') in Ampere Degree Wb.turns Computed current Quintic g(λ, λ') Ampere 0 0 0.14 0.09 0.133 0.083 0.136 18 0.222 0.2 0.15 0.158 0.11 0.154 36 0.423 0.26 0.158 0.172 0.15 0.175 54 0.582 0.34 0.21 0.22 0.23 0.232 72 0.685 0.44 0.28 0.293 0.30 0.308 90 0.72 0.45 0.31 0.31 0..31 0.31 10 0.685 0.34 0.223 0.21 0.208 0.2 126 0.582 0.16 0.078 0.063 0.059 0.051 14 0.423 0 -0.037 -0.05 -0.03 -0.053 162 0.222 -0.1 -0.11 -0.11 -0.062 -0.106 180 0 -0.14 -0.09 -0.13 -0.08 -0.137 9.8 9.4 10.1 9.3 R.M.S.Error % 36 Table 4.3 b. Measured and computed currents (unweighted method of least squares) at 230 V: Angle Flux Measured in linkage in Current Cubic Quinticf(λ') Cubic in f(λ') in A In Ampere g(λ, λ') in Ampere Degree Wb.turns Computed current Quintic g(λ, λ') Ampere 0 0 0.225 0.13 0.19 0.117 0.197 18 0.31 0.3 0.28 0.26 0.174 0.227 36 0.60 0.425 0.34 0.33 0.334 0.345 54 0.83 0.35 0.68 0.69 0.753 0.75 72 0.98 1.35 1.25 1.26 1.32 1.328 90 1.03 1.6 1.53 1.53 1.53 1.53 10 0.98 1.1 1.16 1.15 1.09 1.09 126 0.83 0.5 0.47 0.46 0.408 0.41 14 0.60 0.1 -0.014 -0.01 -0.007 -0.017 162 0.31 -0.15 -0.21 -0.192 -0.098 -0.15 180 0 -0.226 -0.13 -0.191 -0.118 -0.197 8.9 9.4 8.75 6.75 R.M.S.Error % 37 Table 4.3 c. Measured and computed currents (unweighted method of least squares) at 260 V: Angle Flux Measured in linkage in Current Cubic Quinticf(λ') Cubic in f(λ') in A In Ampere g(λ, λ') in Ampere Degree Wb.turns Computed current Quintic g(λ, λ') Ampere 0 0 0.25 0.147 0.216 0.133 0.23 18 0.36 0.35 0.356 0.339 0.21 0.26 36 0.68 0.6 0.48 0.471 0.47 0.47 54 0.94 1.2 1.136 1.144 1.23 1.25 72 1.11 2.1 2.21 2.226 2.3 2.33 90 1.17 2.5 2.747 2.747 2.75 2.74 10 1.11 1.8 2.1 2.09 2.01 1.98 126 0.94 0.9 0.88 0.87 0.78 0.77 14 0.68 0.15 0.032 0.042 0.04 0.036 162 0.36 -0.1 -0.265 -0.25 -0.116 -0.17 180 0 -0.25 -0.147 -0.216 -0.13 -0.22 15.05 9.4 8.75 13.6 R.M.S.Error % 38 Table 4.4a. Measured and computed currents (weighted method of least squares) at 200 V: Angle Flux Measured in linkage in Current Cubic Quinticf(λ') Cubic in f(λ') in A In Ampere g(λ, λ') in Ampere Degree Wb.turns Computed current Quintic g(λ, λ') Ampere 0 0 0.14 0.167 0.149 0.174 0.161 18 0.222 0.20 0.229 0.213 0.232 0.220 36 0.423 0.26 0.277 0.262 0.261 0.272 54 0.582 0.34 0.344 0.333 0.348 0.343 72 0.685 0.44 0.418 0.412 0.420 0.419 90 0.720 0.46 0.423 0.423 0.423 0.423 10 0.685 0.34 0.314 0.320 0.311 0.312 126 0.582 0.16 0.145 0.157 0.141 0.146 14 0.423 0 0.002 0.016 0.002 0.007 162 0.222 -0.1 -0.096 -0.080 -0.099 -0.087 180 0 -0.14 -0.167 -0.149 -0.174 -0.161 15.05 9.4 8.75 13.6 R.M.S.Error % 39 Table 4.4 a. Measured and computed currents (weighted method of least squares) at 230 V: Angle Flux Measured in linkage in Current Cubic Quinticf(λ') Cubic in f(λ') in A In Ampere g(λ, λ') in Ampere Degree Wb.turns Computed current Quintic g(λ, λ') Ampere 0 0 0.22 0.24 0.21 0.25 0.23 18 0.32 0.3 0.337 0.33 0.33 0.32 36 0.60 0.43 0.47 0.457 0.475 0.467 54 0.837 0.85 0.84 0.824 0.846 0.856 72 0.984 1.35 1.37 1.36 1.376 1.39 90 1.035 1.6 1.598 1.59 1.598 1.59 10 0.984 1.1 1.22 1.23 1.216 1.2 126 0.837 0.5 0.55 0.566 0.544 0.535 14 0.60 0.1 0.069 0.08 0.065 0.07 162 0.32 -0.15 -0.14 -0.136 -0.14 -0.123 180 0 -0.225 -0.24 -0.214 -0.25 -0.232 4.58 4.77 4.56 3.9 R.M.S.Error % 40 Table 4.4c. Measured and computed currents (weighted method 0f least square) at 260 V: Angle Flux Measured in linkage in Current Cubic Quinticf(λ') Cubic in f(λ') in A In Ampere g(λ, λ') in Ampere Degree Wb.turns Computed current Quintic g(λ, λ') Ampere 0 0 0.25 0.272 0.242 0.283 0.262 18 0.361 0.35 0.387 0.400 0.384 0.364 36 0.687 0.60 0.600 0.591 0.603 0.599 54 0.946 1.20 1.270 1.254 1.278 1.303 72 1.113 2.1 2.270 1.260 2.276 2.309 90 1.170 2.5 2.731 2.731 2.731 2.731 10 1.113 1.8 2.100 2.110 2.094 2.061 126 0.946 0.9 0.943 0.959 0.935 0.909 14 0.687 0.15 0.141 0.149 0.137 0.141 162 0.361 -0.1 -0.160 -0.173 -0.157 -0.137 180 0 -0.25 -0.272 -0.242 -0.283 -0.262 13.00 13.14 12.9 12.7 R.M.S.Error % 41 Table 4.5 Measured and computed energy loss per cycle (two point method) Voltage Measured Computed energy loss In energy Cubic Quintic Cubicg(λ,λ') in quintic Volts Loss in joules f(λ') in f(λ') in joules in joules joules joules 200 0.354 0.361 0.358 0.361 0.359 230 0.76 0.759 0.739 0.759 0.755 260 0.975 0.979 0.945 0.978 0.978 g(λ,λ') Table 4.6Measured and computed energy loss per cycle (unweighted least square method) Voltage Measured Computed energy loss In energy Cubic Quintic Cubicg(λ,λ') in quintic Volts Loss in joules f(λ') in f(λ') in joules in joules joules joules 200 0.354 0.238 0.301 0.235 0.320 230 0.75 0.759 0.622 0.601 0.734 260 0.975 1.09 0.795 0.845 1.012 g(λ,λ') Table 4.7 Measured and computed energy loss per cycle (weighted least square Method) Voltage Measured Computed energy loss In energy Cubic Quintic Cubicg(λ,λ') in quintic Volts Loss in joules f(λ') in f(λ') in joules in joules joules joules 200 0.355 0.386 0.337 0.396 0.370 230 0.76 0.812 0.697 0.822 0.793 260 0.975 1.049 0.891 1.053 1.044 g(λ,λ') 42 Coefficients by different methods The coefficients A',B' are are determined by all the suggested methods namely two point method,unweighted least square method and weighted method of least squares given in table (4.8).Similarly the coefficients C and D of the loss part of the magnetization have been computed as given in the table(4.8) Table4.8 Coefficient A,B,C,and D by different methods Method A' B' Cubicf(λ) Quintic f(λ) Cubic f(λ,λ') Quintic f(λ, λ') C Two D C D C D C D point 0.33 0.969 0.218 0.008 0.219 0.006 0.218 0.002 0.219 0.03 method Unweighted 0.10 1.195 0.125 0.124 0.184 0.052 0.113 0.241 0.190 0.191 method Weighted 0.29 1.08 0.23 0.01 0.20 0.03 0.24 0.07 0.22 0.07 method 4.6 Conclusions: It is observed from the comparison that the two point method and the weighted method of least squares yield better results for the calculation of energy loss per cycle.The magnetizing characteristic of a transformer including hysteresis has been represented in an analytical form containing two polynomial expressions.One polymomial expression represents the true saturation part and the other represents the loss part .The data for the R.M.S. voltage versus magnetizing component of no load current is useful to evaluate the coefficients of the polynomial representing the true saturation part of the magnetizing characteristic.All the expression for hysteresis loop and the energy loss derived by the three methods with different approximations for the loss part were found to agree well with the experimental results. ********************************************************** 43 CHAPTER 5 SERIES FERRORESONANT CIRCUIT UNDER TRANSIENT CONDITION 5.1Preliminaries: The behavior of the series ferroresonant circuit fig (5.1) under the transient condition needs a different approach to the problem than that used under the steady condition [7,69].The variation of amplitude of oscillations with frequency is shown fig (2.1) for both linear and nonlinear system with negligible damping.It has been found in the nonlinear system that the amplitude of the oscillation increases as the frequency is increased till the point B is reached. A slight change in the frequency makes the amplitude to jump to the point C. The operating point does not return back to the pre jump conditions when the frequency is gradually decreased. When the point D is reached during the decrease in frequency, a jump down occurs at another critical frequency and the operating point returns to D'. The variation of amplitude of oscillations with forcing function at the constant frequency fig (5.2). The amplitude of oscillation jumps from A to B at the critical value of input V01 and then moves along BL with increase in the value of forcing function. When the forcing function is decreased, it traces the path BC instead of BA.At the point C,it jumps back to D at another value of the critical input V01. The operating point follows the path DO with further decreases in the forcing function. The zone separated by discontinuous jump points is very unstable and unrealizable. 5.2 Analysis of Ferroresonant series circuit considering transformer core behavior: A series circuit shown in fig (5.1a) is considerd in the analysis. As shown in the circuit the nonlinear inductor is connected in series with a resistance R and a capacitor C. A low resistance 'r' in parallel with the inductor is modeled as the transformer core loss to account saturation effect, hysteresis loss and eddy-current effect. The circuit is fed with voltage E0.The current flowing in the circuit thus have two component representing the loss component (Ir) and the magnetizing component (IL) fig (5.3).Thus from the basic theory of electricity we write the core loss in the inductor (W) as W = VL I cos θ Where θ is the power factor angle. (5.1) 44 By using the relation for the loss component and magnetizing component Ir = I cos θ IL = I sin θ And again VL = Ir . r Or, r = (VL/ Ir) (5.2) Similarly VL = IL .XL And XL = (VL / IL) (5.3) The voltage equation of the circuit is given by E0= VL + I(R-jXC) (5.4) Also I = Ir – j IL (5.5) Ir = VL/r , XC = (1/wC) where w =1 The equation (5.4) can be written as E0= VL + IR-j IXC (5.6) The equation (5.6) after substituting the value of I becomes E0= VL + ( Ir – j IL)R-j( Ir – j IL )XC (5.7) E0= (VL + IrR – IL XC )-j(ILR+ IrXC) (5.8) E0= [VL + (VL R)/r – (IL XC )]-j(ILR+[(VL /r)XC] [E0]2 = {VL + ( VL R)/r – (IL XC )}2 + j {ILR+[(VL /r)XC}2 [E0]2 = SQRT [{VL + (VL R)/r – (IL XC)}2 + j {(ILR+(VL /r)XC}]2 (5.9) The response curve of the circuit can be plotted using the equation (5.9) with fixed value of resistance R and capacitance C. 5.3 Response curve considering saturation curve as piecewise linear: The magnetizing current versus the applied voltage curve derived from the data of R.M.S. saturation and loss curve can be approximated by a finite number of straight line segments fig(5.4) .The voltage across the non linearity VL will lie on the kth segment if ck <= VL < ck+1.This can be expressed as VL = bk( IL- ak) + ck (5.10) Where bk is the slope of the kth segment and is a known value for the given ak and ck. The equations (5.9) and (5.10) can be used to draw the response curve for any circuit 45 parameter. The flow diagram is shown in fig (5.5) and the computer program is given in the appendix. 5.4 Representation of B-H loop by Hysteresis model for studying transients: The transformer used in electrical networks has a highly nonlinear inductance with iron core losses. A major consequence of hysteresis among other things is that when a transformer is disconnected from the source, residual core flux is established. This remnant magnetism in the transformer core affects among other things on the transients.Moreever the size and type of load if any plays a major role in the final stages of the core after the supply is disconnected. The magnitude of the residual flux depends more importantly on the instant of switching off the supply. The transformer core flux is taken as a function of the flux density and hence the function of voltage. This is because to enable the hysteresis loss, eddy current loss or a combination of both losses to be included in the study of transformer core behavior under transient condition. 5.5 Switching Transients: The effect of switching instant on the possibility of ferrroresonance provides enough data for the analysis of the transformer core under the transient condition. The exact simulation of the transient phenomenon between the switching-in of a circuit and the possible core behavior is essential [5, 13].It is in fact a characteristic of ferrroresonance phenomena that in a given circuit, with same parameters and same supply voltage, different transformer core behavior possible. Obtaining one or other conditions is dependent on the initial conditions namely the remnant magnetism, the phase angle of the voltage on switching in and the capacitor charge etc. The voltage across the transformer rises suddenly during switching-in or due to some other disturbance at a particular input voltage in the same power systems containing transformers and capacitors. As shown in the figure (5.1b) when the circuit is suddenly switched on with a voltage OG, the operating point may either be E or F depending upon the switching instant. Hence the conditions immediately prior to the disturbance must be accurately known. 5.6 Representation of magnetic characteristic of the nonlinear inductor: Linear inductance: The linear current relationship for an inductance is represented as 46 V = L (di/dt) Or i = (1/L) ∫ V dt (5.11) (5.12) For a sinusoidal excitation V = Vm cos wt Or, i= (1/Lw) Vm sin wt (5.13) Nonlinear inductance: The variation of flux linkages with the current can be represented by few piecewise linear segments for the analysis of transformer core behavior. The flux linkage λ lying on the kth segment can be written as λk = bk( i- ak) + ck or (5.14) bk = [λk - ck]/[ i- ak] (5.15) Where bk is the slope of the kth line representing the incremental inductance ak and ck are the co-ordinates of the lower end of the kth segments. 5.7 General equations for the study of transients of Series Ferroresonant Circuits: The series ferroresonant circuit as shown in figure (5.3 a) is considered for the investigation.The nonlinear inductor is connected in series with a resistance R and a capacitor C. As the transformer core behavior including the loss is important in the analysis and hence the coreloss of the transformer core is modeled as a small resistance 'r'in parallel with the inductor. When a sinusoidal input voltage Em sin(wt + Ф) is fed to the circuit. Where Ф is the switching angle.Then the basic equations for the series circuit are Ri + Lk (diL /dt) + 1/C∫i dt = Em sin(wt + Ф) Or, Lk (diL /dt) – ir.r =0 (5.17) ir = (Lk/r)( diL /dt) (5.18) From the circuit i = i r + iL (5.19) (5.16) If the initial values of iL and Q are given as iL0 and Q0, the solution of the differential equation (5.16) will yield (appendix) iL = A exp –(Rt/2 Lk) sin (ν t + θ2) + [Em sin(wt + Ф + θ1)]/Z Where Z= sqrt {(R)2 + (w LK – 1/wC)2} (5.20) 47 tan θ1 = (1/wC – w LK ) /R A sin θ2 = iL0 – [Em sin( θ1 + Ф )/Z] A cos θ2 = (1/ν LkC) [-Q0- (Em cos (Ф + θ1)/ wZ] ν = sqrt {(1/ LK C) – (R2/4 LK2 ) The equation (5.20) is used for the investigation of transients of series ferroresonant circuit and transformer core behaviors under transient condition.The effect of switching angle and circuit parameters on the transients are also investigated in this work. 5.8 Conclusions: The series ferroresonant circuit is investigated to analyze the transformer core behavior under transient conditions. In the investigation a small resistance is connected in parallel to the iron core inductor to study the various core losses like hysteresis and eddy-current besides saturation effect. ************************************************************** 48 CHAPTER 6 SYSTEM UNDER INVESTIGATION AND FINDINGS 6.1 Preliminaries The transformer core behavior under transient condition in a series ferroresonant circuit is much different than in steady state condition. There are many factors which come in to play .Some of the important factors are like magnetizing characteristics of nonlinear inductor, residual flux ,switching angle, capacitor effect and various core loss like hysteresis,saturation and eddy current etc .Besides these the circuit parameters like resistance and capacitance have significant effect in the analysis of core behavior under transient conditions. In the transient condition the circuit exhibits high magnitudes of currents and voltages due to the phenomena. The flux linkage versus magnetizing current characteristic is considered to be piecewise linear unlike the polynomial form in the calculation of loss part. This is because piecewise form is better for computational purposes than the polynomial form in case of study of transformer core behavior. The present investigation includes transformer core loss, residual flux, capacitor effect; switching angle .The investigation on the analysis of transformer core behavior under transient condition has been validated by experimental results. 6.2 System characteristics: The laboratory study is carried on by setting up a single series ferroresonant circuit. (Fig 6.1) The linear parameter chosen are as follows R = 1 ohm C= 12 Microfarads The primary winding of an open circuited transformer with the characteristic as follows 3 KVA, 230 V/230V, 50 Hertz, single phase The effect core loss is represented by a low variable resistance across the magnetizing reactance. The rms excitation characteristics and the loss curves of the transformer under transient conditions are obtained as in the circuit shown in the figures (6.1) . 6.3 True saturation characteristics curve: In stead of the rms saturation curve available from the manufacturer of the transformer the true saturation curve has been considered to represent the magnetic 49 characteristic of the transformer under study. An integrator is used as shown in the fig (3.2) for the determination of true saturation curve. As shown in the figure the nonlinear inductor is fed with a sinusoidal voltage which after integration yields flux linkage(λ).This flux linkage is then fed to the Y channel of a cathode ray oscilloscope(CRO).The different voltage signal proportional to corresponding inductor current is fed to the X channel of the CRO.The hysteresis loop of various shape and sizes are displayed on the screen of CRO as the input voltage to inductor is varied .The tips of the hysteresis loops corresponding to different voltages are then joined to give the i L versus λ characteristics. The curve obtained under laboratory test condition is shown in the figure (4.3) Experimental data for the true saturation curve: Table (6.1) Sl No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Flux linkage (λ) Wb-turn 0.126605 0.218423 0.308466 0.410176 0.511214 0.673511 0.731042 0.750456 0.7711 0.81042 0.86102 0.9004 1.0102 1.04484 1.0882 1.1505 1.17833 1.26212 1.35244 1.6452 Inductance current (iL) In Ampere 0.027 0.0584 0.1114 0.1512 0.26030 0.4703 0.56132 0.583402 0.6524 0.7688 0.934 1.05096 1.30425 1.4184 1.7824 2.118 2.521 3.682 5.6882 6.0242 50 The value of inductance is assumed to remain constant for the entire length of each segment. The value of the inductance for each segment remains same for two limiting values for current in each segment and it changes as the current value considered for the segment considered crosses the limiting value. 6.4. Transients of series ferroresonant circuit under study: The transients obtained with the help of following equation (6.5.1) (Appendix-I) .The computed response curve has been checked with the experimentally obtained curve. IL= A exp – (Rt/2Lk) Sin (ν t +Ө2) + [EmSin (wt +ф+Ө1)]/Z (6.5.1) The current is computed in small steps with the variation of time using the equation (6.5.1).If the current calculated in small steps on the kth linear segment of the magnetizing characteristic crosses either of the limiting values of the segment .It is always essential to find the exact instant at which this occurs (66) Let the limiting current value be I, and then the time is obtained by solving equation (6.5.1) as G (t) = [EmSin (wt +ф+Ө1)]/Z + A exp – (Rt/2Lk) Sin (ν t +Ө2) = I (6.5.2) The value of t in the above equation is solved using Newton-Raphson iteration method in the following ways: The function G'(t) = [w EmCos (wt +ф+Ө1)]/Z] + A exp – (Rt/2Lk) {ν Cos (ν t +Ө2) (R/2Lk) Sin (ν t +Ө2) (6.5.3) Initially the value of t is assumed as the time step just before the current crosses the limiting value t'. Then Δt = [I – G(t')]/G'(t) (6.5.4) The value of t is now modified as t=t' + Δt (6.5.5) With the above value taken as t', G (t') is again computed and another value of t is obtained by relation (6.5.3) and (6.5.4).This method is repeated till Δt is negligibly small. The final value of t then become the solution of equation (6.5.2) Finding out the solution: For kth segment of the characteristic, the current at small interval is computed as soon as it crosses any of the limiting value of current for the segment. The exact time at which it occurs is determined by the technique mentioned. The current and charge at this instant 51 becomes iL(0) and Q0 with k = k+1 or k-1 . The time t measured from this instant for calculation of next linear segment of magnetizing characteristic. 6.5. Intial charge of capacitor and switching angles The initial charge in the capacitor is obtained by using the relation Q= ∫ iLdt The value of iL is obtained by using equation (6.5.2) and the initial value of i L (0) and Q0 are taken as zero for the first linear segment. The initial charge for the segment is calculated by the integration of current (iL) in the time interval of first segment when it crosses the limiting value. The initial value of current for the second segment is the limiting value for the first segment. In this way all the linear segments of the characteristic are used for the computation of the initial charge in the capacitor. The phase angle of voltage on switching play one of the important effect of transformer core behavior under transient condition .For this purpose a triac circuit is used to determine the exact instant of switching in.The analysis is done for two switching angles zero and 90 degree. 52 [CRITICAL VOLTAGE AND CURRENT UNDER STEADY STATE] [R=1 OHM C = 12 MICROFARAD, VOTAGE PEAK=480 V, CURRENT PEAK = 750 MILLIVOLT] 53 CURRENT UNDER STEADY AND STATE [ R=1 OHM, C=12 MICROFARAD] 54 EFFECT OF INPUT TRANSIENT VOLTAGE TOP-200 V, MIDDLE-230 V, BOTTOM-260 V, R=1 OHM, C = 12 MICROFARAD,SWITCHING ANGLE=0 55 6.6. Effect of input voltage: The effect of input voltages namely 200 volts, 230 volts and 260 volts across the iron core inductor of the transformer under transient condition have been studied. The computed values are given in tables (6.1) and (6.2) respectively. The computed and experimental plots have been presented in figures (6.2).The curves found to show that the computed and experimental data found to be in close agreement. TRANSIENTS FOR 200 VOLTS AND ZERO DEGREE SWITCHING ANGLE CURRENT IN AMPERES 10 5 0 -5 1 5 9 13 17 21 25 29 33 37 41 45 49 53 -10 -15 TIME IN MILLISECONDS TRANSIENTS AT 230 VOLTS AND ZERO DEGREE SWITCHING ANLES CURRENT IN AMPERES 15 10 5 0 -5 1 5 9 13 17 21 25 29 33 37 41 45 49 53 -10 -15 TIME IN MILLISECONDS CURRENT IN AMPERES TRANSIENTS AT 260 VOLTS AND ZERO DEGREE SWITCHING ANGLE 15 10 5 0 -5 1 -10 -15 -20 6 11 16 21 26 31 36 41 46 51 TIME IN MILLISECONDS COMPUTED TRANSIENTS FOR SWITCHING ANGLE= 0 DEGREE FOR VOLTAGE 200V, 230 V AND 260 V 56 CURRENT IN AMPERES TRANSIENTS AT 200 VOLTS AND 90 DEGREE SWITCHING ANGLE 8 6 4 2 0 -2 -4 -6 -8 1 5 9 13 17 21 25 29 33 37 41 45 49 TIME IN MILLISECONDS CURRENT IN AMPERES TRANSIENTS AT 230 VOLTS AND 90 DEGREE SWITCHING ANGLES 10 5 0 1 5 9 13 17 21 25 29 33 37 41 45 49 53 -5 -10 TIME IN MILLISECONDS CURRENT IN AMPERES TRANSIENTS AT 260 VOLTS AND 90 DEGREE SWITCHING ANGLE 10 5 0 1 5 9 13 17 21 25 29 33 37 41 45 49 53 -5 -10 TIME IN MILLISECONDS EFFECT OF INPUT TRANSIENT VOLTAGE TOP-200 V, MIDDLE-230 V, BOTTOM-260 V, R=1 OHM, C = 12 MICROFARAD, SWITCHING ANGLE=90 57 EFFECT OF VARIATION OF CAPACITANCE TOP = 24 MIDDLE= 18 BOTTOM = 12 MICROFARADPEAK CURRENT = 30 A, 21 A AND 14.5 A 58 HYSTERESIS LOOP UNDER NORMAL CONDITION 59 6.7. Computed results. Table (6.2) Applied input voltage E0 in Volts 0 22.5 40.1 44.1 55.5 64.1 70.8 77.1 82.5 86.2 90.1 89.5 86.8 85.1 80.5 71.3 65.8 53.5 46.9 38.0 45.5 133.5 165 206 307 Voltage across nonlinear Inductor VL in volts 0 40 70 80 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 Current through nonlinear Inductor iLin Amperes 0 0.101 0.16 0.18 0.22 0.29 0.24 0.26 0.28 0.31 0.34 0.39 0.45 0.51 0.58 0.67 0.76 0.88 0.98 1.15 1.35 1.59 1.92 2.3 2.83 60 6.8 Experimental results. (R= 1 ohm C = 12 microfarad) Table (6.3) Input voltage (E0 ) In volts 0 20 30 40 50 60 70 80 90 100 104 104 110 120 130 140 150 160 180 200 230 260 230 200 180 160 140 120 100 70 50 46 46 40 30 20 0 Voltage nonlinear Inductor volts(VL) 0 24 37.5 52 61.5 81 96 109 126 142 148 280 282 285 285 286 287 291 293 295 298 301 298 295 293 291 286 285 278 270 262 254 58 52 38 25 0 across Current through Nonlinear inductor in (iL )In Amperes 0 0.025 0.05 0.08 0.1 0.125 0.14 0.156 0.18 0.226 0.25 1.9 1.95 1.95 1.98 1.985 2.02 2.1 2.16 2.26 2.52 3.16 2.85 2.62 2.43 2.36 2.02 1.98 1.86 1.64 1.36 1.26 0.1 0.08 0.06 0.03 0 61 6.9 Study of Transients: (A) Different input voltages and fixed values of R = 1 ohm, C = 12 ohm and Switching angle = 0 degree: Table (6.4) Time (t) in Current through nonlinear inductor ( iL) Millisecond Applied input Applied input voltage voltage (200 (230 volts) volts) 0 0 0 2 0.1 0.124 4 0.155 0.19 6 0.132 0.1604 8 0.038 0.038 10 -0.12 -0.136 12 -0.25 -0.294 14 -0.305 -0.371 16 -0.275 -0.332 18 -0.15 -0.185 20 0.035 0.036 22 0.205 0.318 24 0.836 1.0 26 -9.78 -11.71 28 -6.34 -4.68 30 3.94 5.3 32 8.26 10.45 34 0.025 0.072 36 -5.606 -7.34 38 -3.82 -4.62 40 2.31 3.25 42 6.04 8.24 44 -0.28 -0.584 46 -3.88 -5.12 48 -1.35 -1.682 50 3.44 4.52 52 3.82 4.88 54 -0.612 -0.972 56 -3.868 -5.02 58 -2.02 -2.45 60 1.7 2.38 62 2.1 2.68 64 -0.796 -1.18 66 -2.31 -3.05 68 -0.086 -0.064 Applied input voltage(260 volts) 0 0.13 0.201 0.431 0.495 0.295 -0.155 -0.691 -1.08 -1.12 -0.732 0.005 1.1 -13.85 -5.25 6.05 12.326 -0.002 -8.32 -5.12 3.81 9.92 -0.751 -5.76 -1.88 5.14 5.42 -1.16 -5.66 -2.68 2.78 3.04 -1.37 -3.48 -0.732 62 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 2.78 2.28 -0.85 -2.6 -1.12 1.05 0.904 -0.86 -1.27 0.556 2.18 1.42 -0.808 -1.74 -1.36 0.052 3.615 2.78 -1.14 -3.35 -1.285 1.76 1.152 -1.206 -1.676 0.732 2.81 1.718 -1.12 -2.214 -0.758 0.742 4.065 3.212 -1.424 -3.752 -1.372 1.735 1.306 -1.310 -1.92 0.808 3.121 1.882 -1.276 -2.462 0.782 0.892 (B) different input voltages and fixed values of R = 1 ohm, C = 15 ohm and Switching angle = 90 degree Table (6.5) Time (t) in Current through nonlinear inductor ( iL) Millisecond Applied input Applied input voltage Applied voltage (200 volts) (230 volts) inputvoltage(260 volts) 0 0 0 0 2 0.1 0.124 0.13 4 0.155 0.19 0.201 6 0.132 0.1604 0.431 8 0.038 0.038 0.495 10 -0.12 -0.136 0.295 12 -0.25 -0.294 -0.155 14 -0.305 -0.371 -0.691 16 -0.275 -0.332 -1.08 18 -0.15 -0.185 -1.12 20 0.035 0.036 -0.732 22 0.205 0.318 0.005 24 0.836 1.0 1.1 26 -5.78 -7.71 -8.85 28 -3.34 -4.68 -5.25 30 3.94 5.3 6.05 32 6.26 8.05 9.026 34 0.025 0.072 -0.002 36 -5.606 -7.34 -8.32 63 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 -3.82 2.31 4.04 -0.28 -3.88 -1.35 3.44 3.82 -0.612 -3.868 -2.02 1.7 2.1 -0.796 -2.31 -0.086 2.78 2.28 -0.85 -2.6 -1.12 1.05 0.904 -0.86 -1.27 0.556 2.18 1.42 -0.808 -1.74 -1.36 0.052 -4.62 3.25 5.24 -0.584 -5.12 -1.682 4.52 4.88 -0.972 -5.02 -2.45 2.38 2.68 -1.18 -3.05 -0.064 3.615 2.78 -1.14 -3.35 -1.285 1.76 1.152 -1.206 -1.676 0.732 2.81 1.718 -1.12 -2.214 -0.758 0.742 -5.12 3.81 5.92 -0.751 -5.76 -1.88 5.14 5.42 -1.16 -5.66 -2.68 2.78 3.04 -1.37 -3.48 -0.732 4.065 3.212 -1.424 -3.752 -1.372 1.735 1.306 -1.310 -1.92 0.808 3.121 1.882 -1.276 -2.462 0.782 0.892 7.10. Conclusions: Investigations of transients for study of transformer core behavior have been done in detail for a single phase series Ferro resonant circuit. The behaviors of the circuit under transient conditions have been analyzed both theoretically and experimentally. This present chapter gives a detail account of the results obtained theoretically and experimentally. A brief comparison of both the results of all the findings described in the previous chapters have been done in tabular form and also in graphical form for easy understanding and analysis of the problem and its solution suggested. The CRO reports are shown for necessary comparison with analytically computed curves. 64 CHAPTER 7 GENERAL CONCLUSIONS AND SUGGESTION FOR FUTURE WORK 7.1 General Conclusions: The analyses of magnetizing characteristics of a transformer for study of transformer core behavior under transient conditions have been studied in depth in the present thesis. The magnetization characteristic of a transformer with negligible iron loss is modelled by its magnetizing branch. A generalized technique has been developed to derive its true saturation characteristic in piecewise linearised segments .The suggested method to derive the instantaneous curve is accurate over any extended range of I.C, including very high voltages in te saturated air core region. The accuracy of the method has been improved by optimizing the number of segments representing the I.C over a desired range thus the computer aided method for deriving I.C with optimum number of segments from the r.m.s. saturation data yields an optimal true saturation characteristics with prescribed degree of accuracy. A new concept of r.m.s error has been introduced in the thesis for deriving magnetization and hysteresis loss characteristics of transformers. This has resulted in more accurate results when compared to average error approach. Moreover the method computation of I.C. does not involve any trial and error procedure whereas the method suggested by other earlier workers involve cut and trial process to obtain a point on the instantaneous curve. The true saturation characteristic has been represented by a two term fifth degree polynomial and it is shown that it can be predetermined using r.m.s. data available from the manufacturer.The methods suggested for predetermination of I.C are two point method unweighted least square method. The two point method is suitable where the computation for modeling should be simple and quick. This is a new approach for the predetermination of an I.C in an analytical form from the manufacturer's data in r.m.s form.By this method,the process of conversion from r.m.s curve to I.C. and I.C. to r.m.s. form is possible through two analytical equations where as the earlier workers suggested an analytical method of conversion. Out of various methods for predetermination of I.C, 65 the method of using multiple point data and weighted least square method yields more accurate results. Each of the methods suggested for predermination of I.C using a polynomial has also been applied to evaluate the resultants true saturation characteristic of two reactors in parallel or series. It has been found that the true saturation characteristic of individual reactors need only be available in one form ,namely, i=f1(λ) whereas the method suggested by Talukdar et al, requires these characteristics in two forms , i=f1(λ) and λ=f(i). A procedure is developed for quantitative determination of third harmonic flux linkage and consequent over voltage magnitudes on the secondary side of the Y/∆ transformer bank under certain internal fault conditions.The computed results validated by experiment establish the existence of over voltage phenomenon so that the distribution engineers in future to make necessary provisions for proper coordination of protective devices. Generally,it is adequate to model the transformer saturation characteristic by a single valued nonlinear inductance,neglecting the hysteresis phenomenon.However, for improved accuracy it is desirable to include hysteresis phenomenon.In this thesis the magnetization characteristic of a transformer including hysteresis has been represented in an analytical form containing two polynomial expressions one polynomial expression representing the true saturation part and the other representing the loss part of the magnetization characteristic. Each of the two polynomial expressions has been formed with two terms only. The data of r.m.s voltages versus magnetizing component of no load current are useful to evaluate the coefficient of polynomial expression representing the true saturation part of the magnetization characteristic. Similarly the data of r.m.s voltage versus the loss component of no load current is useful for finding the coefficients of the loss part of the magnetization characteristic. Both the data are obtained either from the manufacturer or a test on the transformer. Modelling of a transformer including hysteresis is desirable in transient simulation studies such as the inrush current drawn by a transformer possessing a residual flux when it is energized;the determination of residual flux remaining in a transformer when it is deenergised and examination of phenomena etc.For the purpose,the modeling 66 of hysteresis loop has been presented in the existing literature by either a differential equation or some mathematical expressions based on fourier series or arational function approximation.All these suggested methods require experimental hysteresis loops t for determination of magnetization characteristic where as the methods suggested in the thesis do not require the experimental hysteresis loop for its determination but require only the r.m.s data including no load loss. The expressions suggested for describing the hysteresis loop exhibits the hysteretic property of increasing the loop area with increase of frequency of operating voltage.All the expressions describing the hysteresis loop under various approximations of loss part have been used to derive the corresponding expressions for hysteresis energy loss. The present thesis is an in-depth investigation of transformer core behavior under transient conditions applied to series ferroresonant circuits in this study; a mathematical model was developed to analyze transient phenomena under different circuit parameters and for different switching angles. The mathematical model developed in the thesis for different transformer core losses is simple for computational purposes than other methods discussed by earlier workers in this area. The results obtained in the suggested method are found to agree well with the experimental findings. The new method is based on mathematical model based on piecewise linearization of magnetic characteristic of the iron core inductor. It was found that a voltage applied suddenly to the system shows more severe jump in the system parameters like current or voltage then that of input voltages applied gradually.In the later case the circuit attains ferroresonant conditions for particular input voltage which is a function of system resistance and capacitance.The initial input voltage for depends on the value of resistance ,capacitance and switching angle.This condition is achieved when the magnitude of suddenly applied voltage is more than the critical value corresponding to particular circuit condition.The ferroresonant conditions giving rise to very high system voltage and current occurs when the phase angle on switching in is zero degree.the transformer core loss in this condition is the minimum but at switching angle 90 degree the jumps are very less and the transformer core loss is maximum.An increase in the value of circuit capacitance requires a higher input voltage for the onset of under the transient condition.The peak value of current through the inductor increases with a 67 decrease in the value of circuit résistance. The effect of core loss by way of putting resistance in parallel to the inductor circuit gives better result than calculating the loss separately in to consideration. 7.2. Suggestions for future work: The present investigation can be potentially extendable to three phase ferroresonant circuits.The coreloss which is modeled by a constant resistance across the nonlinear reactor can be improved by considering the three nonlinear effects found in the iron cores viz saturation,hysteresis and eddy currents. The leakage reactance and resistance of primary winding so far neglected in this analysis can be taken into account for more correct investigation of the core behavior under transient conditions. The effect of residual flux on transients can be further improved by better modeling the hysteresis loss and of including dielectric loss of the capacitor. Inclusion of three terms in the polynomial expression for magnetizing saturation curve is so far not included in the investigation which can be done in future work.Multivalued modeling having the major and minor loops of magnetization extending the methods suggested can be taken in the further work. 68 REFERENCES 1. S.N.Talukdar, J.K.Dickson, R.C.Dugan, M.J.Sprinson and C.J.Lenda "on modeling transformer and reactor saturation characteristics for digital and analog studies" IEEE Trans.Power apparatus and systems, Vol.PAS-94, 1975, pp 612-621. 2. P.A.Abetti,"Transformer models for the determination of transient voltages,"AIEE Trans.Power Apparatus and systems No.6, June 1953, pp.468-475. 3. G.W.Swift,"Power transformer core behavior under transient conditions,'' IEEE Power meeting New York, Jan 31-Feb5, 1971. 4. L.O.Chua and K.A.Stromamos," Lumped circuit models for nonlinear inductors exhibiting hysteresis loops,"IEEE Trans.circuit theory .Vol.CT-17, 1970, pp..564-574. 5.Lamba,H.,Grinfeld,M.,McKee,S.,Simpson,R.:"Subharmonic ferrroresonance in an LCR circuit with hysteresis,IEEE Transaction on Magnetics,Vol.33,No.4,1997,pp.2495-2500. 6. R.Javora., M.Iwahara. S.Yamada.'Dynamic Hysteresis Loop and its Application to a Series Ferrroresonance Circuit." Journal of Electrical Engineering, Vol.48, 2000, pp.2425. 7. J.G.Santesmases, J.Ayala, and A.H.Cachero,"Analytical approximation to series ferroresonant circuit,"Proc.IEE, Vol.117, 1970, pp.234-240. 8. W.K.Macfadyan, RR.S.Simpson, R.D.Slater and W.S.Wood,"Representation of magnetization curves by exponential series,"Proc.IEE, Vol 120, 1973, pp.902-904. 9. G.F.T.Wedger,"Representation of magnetization of magnetization curves over extensive range by rational fraction approximations,"Ibid, Vol.116, 1969, pp.156-160. 10. E.P.Dick and W.Watson,"Transformer models for transient studies based on field measurements,"IEEE Trans.Vol.PAS-100, 1981 pp.409-4177. 11. G.W.Swift,"An analytical approach to ,"Ibid .PAS-87, 1969, pp.42-47. 12. Iwahara, M., Yamada, S.:'Characterized Hysteresis Model and a Magnetic Pulse Compression Circuit." Journal of Electrical Engineering, Vol.48, 1997, pp.24-25. 13. J.W.Teape, R.D.Slater, R.R.S.Simpson, and W.S.Wood,"Hysteresis effects in transformers, including ferrroresonance"IEE, Proc.Vol.123, Feb.1976. 14. Iravani, M.R. et al.;"Modelling and analysis guidelines for slow transients.III.The study of ".IEEE Trans. On Power Delivery Vol.15.Issue 1, Jan 2000 pp.255-265. 69 15. Li.H.; Fan, Y.; Shi.R."Chaos and ."Electrical and Computer Engg.2006, CCECE'06, Canadian Conference on .May 2006.pp.494-497. 16. Afshin Rezaei-Zare; Sanaye-Pasand, M.; Mohseni, H.; Farhangi, S.; Iravani, R.;"Analysis of Modes in Power Transformers Using Preisach –Type Hysteretic Magnetic Inductance." IEEE Trans. On Power delivery .Vol.22, Issue 2, April 2007 pp.919-929. 17. Rezaei-Zare, A.; IRavani,R.;Sanaye-Pasand.M.;Moheseni,H.;Farhangi,S.;"An Accurate Hysteresis Model for Analysis of a Transformer",IEEE Trans.on Power Delivery.Vol.23.Issue 3.July 2008 pp.1448-1456. 18. AfshinRezaei-Zare;Mohseni,H Sanaye-Pasand,M.;Farhangi,S.;Iravani,R"Performance of various magnetic core models in comparison with the laboratory test results of ferrroresonance test on a 33 kV voltage transformer.' Power Engineering Society General Meeting, 2006 IEEE 18-22 June 2006 . 19. I.A.Wright and K.Morsztyn," Sub harmonic oscillations in power systems-theory and practice,"Ibid, PAS-89, 1970, pp.1806-1814. 20. J.Rivas, J.M.Zamrro, E.Martin, and C.Pereira,"Simple approximation for magnetization curves and hysteresis loops,"IEEE Trans.Magn.Vol.MAG-17, 1981, pp.1498-1502. 21. S.Prusty and M.V.S.Rao,"New method for predetermination of true saturation characteristics of transformers and nonlinear reactors,"Proc.IEE, Vol.127.pt.c, 1980, pp.106-110. 22. S.Prusty and M.V.S.Rao,"A direct piece wise linearised approach to convert r.m.s. saturation characteristic to instantaneous saturation curve,"IEEE Trans.Magn.Vol.MAG16, 1980, pp.156-160. 23. S.Prusty and M.V.S.Rao,"A novel approach for predetermination of magnetization characteristics of transformers including hysteresis,"Ibid, Vol.MAG-20, 1984, pp.607612. 24. E.J.Dolan, D.A.Gilles and E.W.Kimbark," in transformer switched with an EHV line,"IEEE Trans., PAS-91, 1972, pp.1273-1280. 25. S.N.Bhadra,"A direct method to predict instanantaneous saturation curve from rms saturation curve,"IEEE Trans, Magn, Vol.MAG-18, 1982, pp.1867-1870. 70 26. S.N.Talukdar and J.R.Bailey,"Hysteresis models for system studies," IEEE Trans.Vol.PAS-95, 1976 pp.1429-1434. 27. A.Clerici,"Analog and digital simulation for transient over voltage determination,"Electra, no.22, May, 1972, pp.111-138. 28. R.J.Kavanagh,"An approximation to the harmonic response of saturation devices"'Proc.IEE. Vol.107, C, 1960, pp.127-133. 29. F.C.Trutt, E.A.Erdedyi and R.E.Hopkins,"Representation of the magnetization characteristics of the D.C. Machines for computer use,"Proc.IEEE, International power meeting, New York, 1967, pp.67-77. 30. D.Briansky,"Single analytical formula for the entire B/H curve," International J.Elec.Engg.Education, 5(2), 1967, pp.199-201. 31. E.C.Lister," on rural distribution system", IEEE Trans.Industry applications.Vol.IA9,No.1,Jan/Feb 1973, pp.105-111. 32. A.M.Sharaf,"Harmonic interference from distribution systems," IEEE Trans.1982, PAS-101.pp.2975-2981. 33. J.G.Frame, N.Mohan and T.Liu,"Hysteresis modeling in an electro magnetic transients," IEEE Trans.Vol.PAS-101, No.9 Sept.1982.pp.3403-3411. 34. A.R.Kelkar and S.G.Galgali,"Determination of transformer magnetizing characteristic from a Fourier analysis of the exciting current wave form,"Proc.IEE.,B(3)Vol.129,may 1982,pp.180-181. 35. J.Tellinen." A scalar model for magnetic hysteresis"IEEE Trans.Magn.Vol.34, No.4.1998. 36. B.Edoardo et al."Parameters affecting Ferrroresonance in LCR Electric Circuits." IEEE Trans.Magnetics, Vol.44 -6, pp.870-873, June2008. 37. H.Lamba., S.McKee. R.Simpson."The effect of Circuit parameters on Ferroresnant Solutions in an LCR Circuit."J.Phys.A:Math.Gen 31 No.34, pp.7065-7076, 28th Aug 1998. 38. G.Bertotti,"General properties of power losses in soft ferromagnetic materials"IEEE Trans.Magn.Vol.24, pp.621-630, Jan, 1988. 71 39. G.Bertotti, F.Florio and M.Pasquate,"Measurement and prediction of dynamic loop shapes and power losses in soft magnetic materials",IEEE Trans.Magn.Vol.29,pp.34963498,Nov.1993. 40. M.A.Coulson, characteristic R.D.Slater including and hysteresis R.R.S.Simpson,"Representation using Preisach's of magnetic theory,"Proc.IEE Vol.124, No.10.pp.895-898, 1977. 41. D.C.Jiles, and J.B Thoelke "Theaory of ferromagnetic hysteresis determination of model parameters from experimental hysteresis loop" IEEE. Trans. Magn.Vol.25, PP.3928-3930, 1988. 42. I.D Mayergoyz,"Mathematical model of hysteresis" IEEE, . Trans. Magn. Vol22, PP.603-608, 1986. 43."Mathematical model of hysteresis" New York Springer- Verlag, 1991. 44. Ismail A. Mohammed, A.R.Bakir, Al Hashemy and Mohd A Tarfik"A Fourier descriptor model of hysteresis loops in sinusoidal and distorted forms" IEEE.Trans. Magn. Vol.33, No.1, 1997. 45. M.K.Al Sherbiny,"Representation of the magnetization characteristic by sum exponential" IEEE. Magn. Vol. MAG-9, pp.60-61, 1973. 46. Torre, E.D.:"Magnetic Hysteresis, IEEE Press,New York,1999. 47. J.H. Hwang and W.Lord "Exponential Series for B-H curve modeling" Proc.IEEE. Vol-123, pp.559-560, June 1976. 48. C.T Zahn and R.Z Roskies"Fourier description for plane closed curves" IEEE. Tran's .Comput. Vol.C-21, pp269-281, 1972 49. R.N New berry, "Prediction of magnetism hysteresis loop for distorted wave forms".IEEE Elect. Power. Appl.VOL.2, No.2, pp.46-50, April, 1979. 50. C.Isoborn,"Ferroresonant flipflop" Electronics New York, Vol.25, No.4, April 1952, pp.121-123. 51. J.C West, and B.V Jayawant "A nonlinear oscillating motor" Proc Iee, 1962, Vol.109, PP.292-300. 52. SS Udpa, and W.lord "A fourier description model of hysteresis phenomena" IEEE .Trans.Magn.Col.MAG.21, pp.2370-2373, Nov.1985. 72 53. SS Udpa, "Finite element modeling of residual magnetic phenomena" M.S Thesis Colorado State University, 1980. 54. S.H Charp,"Magnetic hysteresis model". IEEE.Trans.Magn. Vol.MAG-110, No.4, 1974, pp.1091-1096. 55."A calculation survey on failures in large power transformer in service" Electra No.88, May, 1983. 56. F.De Leon, and A.Semlyn,"Complete transformer model for electromagnetic transients", presented at IEEE Winter Meetings, Feb, 1993. 57. K.H Carpenter,"A differential equation approach to minor loops in the jile-atherton hysteresis model" IEEE.Trans.Magn.Vol.27 No.6, 1991. 58. A.P.Dash, and G.R.Patel ,"Modelling two transformer in series or parallel for study." OPSBulletin, 1998. 59. G.R.Patel, and A.P.Dash,"Modelling transformer including hysteresis.' OPS Bulletin 2000. 60. A.P.Dash, and Pratima Rath,"Threshold Voltage." Condensed Matter Days 2005 ,Orissa,India 29-31 August 2005. 61. A.P.Dash."Digital Simulation of Magnetization Characteristics and Hysteresis Loss by Different Methods for use in Transformer Modelling.'INTERMAG2009, Sacramento, California USA,May 4-8,2009.(Accepted) 62. A.P.Dash, and Pratima Rath,"Analysis of Parallel Circuits considering Coreloss,"OPS Bulletin 2009(Communicated) 63. A.P.Dash and G.R.Patel,"Modelling transformer including hysteresis' OPS Bulletin 2000. 64. D.C Jiles and D.L Atherton,"Ferromagnetic hysteresis" IEEE.Trans.Magn. Vol.MAG-19, pp.2183-2185, Sept.1983. 65. M.Pardvi, Horvath and G.Verstesy,"Minor loop behaviour in classical preisach hysteresis systems", IEEE.Trans.Magn.1997. 66. P.K Mukherjee and S Ray." Computation of transient for ferrroresonance studies" J.Inst.Engg (India), Electr. Eng. Div.1978 59, pp.178-181. 67. S.Hassari,"Foundation of Mathematical Physics", BostonMA, Allyn and Bacon 1991, pp.567. 73 68. A.P.Dash, and Pratima Rath,"Computation of Over voltages due to third Harmonic flux linkage in transformer." (Paper communicated to 7th International Symposium on Hysteresis Modeling and Micromagnets, May 11-14, 2009, Gaithersburg, Maryland, USA) 69.N.Germay,S.Mastero and J.Vroman,"Review of Ferro resonance Phenomena in High voltage Power System and presentation of a Voltage Transformer model for Predetermining them. International Conference on Large High Voltage Electric systems.1974 Session (21-29 August) 70. J.R.Marti, and A.C.Soudack." in power system fundamental solutions "IEE Proc.C.1991, 138(4), pp.312-329. 71. S.Ray,"Analysis of sub harmonic oscillation in power system,a general approach"J.Inst.Engg(India)Electr.Engg.Div.1982(62)pp.230-236. 72. S.K.Chakravarthy, andC.V.Nayar,"Ferroresonant oscillations in capacitor voltage transformer", Proc.Inst.Electr.Engg.1995 Vol.142, pp.30-36. 73. A.P.Dash,"Effect of residual flux on switching transients," Journal of Sc&Tech., Sambalpur University. ********************************************************** APPENDIX Computation of current under transient condition 74 The equation (4.6.9) is a second order differential equation can be solved by use of Laplace transform method. The time response differential equation LkdiL/dt + RiL+ (1/C) ∫iLdt = Em Sin (wt+ф) (1) Taking the Laplace transform of equation (1) we get – LkSiL(S) LkiL(0) + RiL(S) + iL(S)/C.S+Q0/C.S ф)(S2+w2)]+[(S.EmSinф)/(S2+w2)] S2iL(S)-SiL(0) + (R/Lk) S iL(S) =[(w.EmCos (2) + [iL(S)]/[Lk Cosф]/[LK(S2+w2)]+[SEmSinф]/[Lk(S2+w2)] C]+Q0/(Lk.C) = [Emw S (3) Rearranging the equation (3) we get IL(S)[S2 +(R/Lk)S + 1/Lk.C]-S iL(0) + Q0/Lk.C = [Em w S Cos ф]/[Lk(S2 +w2)] + [ S2 EmSinф]/[Lk.(S2+w2)] (4) IL(S) = ([S iL(0)]/[S2+(R/Lk)S + 1/Lk.C])- Q0/Lk.C [S2 +(R/Lk)S + 1/Lk.C])+ [Em w S Cos ф]/[ LK(S2+[ R/Lk)S+1/Lk.C)( S2+w2)]+ [ S2 EmSinф] /[Lk.(S2+w2)] 1/Lk.C] S2 +(R/Lk)S + (5) The time domain equation of current is obtained by taking inverse Laplace of both side of the equation (5) Considering each term of the equation (5) inverse Laplace of (1) iL(S) = iL (2) [S iL(0)]/[S2+(R/Lk)S + 1/Lk.C] is breaked to [S iL(0)]/ [S2+(2 R/2Lk)S++[ 2 R/2Lk) +( 1/Lk.C)] (6) (7) 2 2 = [iL(0)].S/[(S+R/2Lk) +[( 1/Lk.C)-( R/2Lk) ] = [ iL(0)].S/[( S+a)2+b2] Where a= R/2Lk b= [(1/Lk.C)-(R2/4Lk2)] a2+b2=1/Lk.C =w02 (8) 75 Now inverse Laplace of equation (8) is = iL(0) [exp(-at).Cos(bt)-(a/b)exp(-at)Sin(bt)] (3) (9) –Q0/[ Lk.C(S2+( R/Lk)S+1/Lk.C)] = - (Q0/ Lk.C) [1/(S+a)2 +b2] (10) Inverse Laplace of equation (15) is = - (Q0/b Lk.C) exp (-at) Sin (bt) (11) (4) (Em w S Cosф)/(Lk(S2 +w2)(S2 + [R/Lk] S +1/Lk.C] = [(Em Cosф)/Lk ][w.S/(S2+ w2)[(S+a)2+b2]} (12) The partial fraction of equation (12) is = [(Em Cosф)/Lk][B0/( S2 +w2) +B1S/( S2 +w2)+C0/)[(S+a)2+b2] + C1S/)[(S+a)2+b2}] (13) The values of B0 , B0 , C0 ,C1 can be found out B0= 2 aw3/D (14) B1= -w (w2 –w02)/D (15) C0 = - (2aw w02)/D C1 = w (CD (16) (17) Where D= (C + 4 a2w2 Putting the values c in equation (13) =[(Em Cosф)/Lk][(2aw3)/D(S2 + w02)- w ((w2 –w02)S/D. (S2 +w02)+ (-2aww02)/(D[(Sa2)+b2])+[ w(w2 –w02)S]/D[(S+a)2+b2]] (18) Rearranging the equation (18) = [(Em Cosф)/Lk ][(2aw3)/D(S2+w02) - w(w2 –w02 )/D] (S/( S2 +w2))+[ w(w2 – w02)(S+a)]/D[(S+a)2+b2]] (19) Taking the inverse Laplace of equation (19) = (Em Cosф)/Lk ][( 2aw2/D)Sin (wt)-[w( w2 –w02)/D] Cos (wt) + [w(w2 – w02)/D]exp(-at) Cos (bt)[aw (w2 +w02) Db] exp (-at) Sin (bt)]] (20) (5)Laplace inverse of [S2Em Sinф]/[ Lk ( S2 +w2) (S2 +R/ Lk ).S + 1/Lk.C] = [(Em Sinф]/ Lk ][ S2/( S2 +w2).[( S+a )2)+b2]] (21) 76 Taking the partial fraction of equation (21) =[(Em Sinф]/ Lk ][B0/( S2 +w2) +B1S/( S2 +w2) +C0[( S+a )2)+b2]+C1S / [ ( S+a )2)+b2 ]] The value of B0 , B0 , C0 ,C1 can be found out as B0= w2(w2 –w02)/D (22) B1= 2aw2/D (23) C0 =-w0 2(w2 –w02)/D (24) C1= -2aw2/D (25) Putting the values of B0 , B0 , C0 ,C1 in equation (21) = [(Em Sinф]/ Lk] [ w(w2 –w02)/ D(S2 +w2) + 2aw2S/D(S2 +w2) - w0 2(w2 –w02)/D{( S+a )2)+b2} - 2aw2S2/D [( S+a )2)+b2]] (26) =[(Em Sinф]/ Lk] [ w(w2 –w02)/ D(S2 +w2) + 2aw2S/D(S2 +w2)- 2aw2(S+a)/D [( S+a )2)+b2}+ B {2aw2- w0 2(w2 –w02)/D b{(( S+a )2)+b2} (27) The inverse Laplace equation (27) is = [(Em Sinф]/ Lk] [ w(w2 –w02)Sin (wt)/D + (2aw2/D).Cos (wt)-( 2aw2/D)exp(-bt) Cos (bt)) +[2aw2- w0 2(w2 –w02)/D b}[ exp(-at) Sin (bt)]]] (28) Now adding the equations (9), (11), (20), (28) IL = IL(0)[exp Cos (bt) – (a/b)exp (-at) Sin (bt)] – [Q0/b Lk. C ][exp(-at) Sin(bt)] +[Em Cosф)/Lk ]. [(2aw2/D).Sin (wt)-{w/D} {(w2 –w02)}}Cos(wt)+ {w(w2 –w02)/D}exp(at)Cos (bt)-[aw/bD]( w2 –w02)exp(-at) Sin(bt)] +[(Em Sinф]/ Lk] [w(w2 –w02)Sin (wt)/D] Sin wt + [(2aw2/D).Cos (wt) +[2aw2(bt)] (29) w0 2(w2 –w02)/D b}[ exp(-at) Sin 77 The equation (29) can be solved as IL(1) = [(Em Sinф]/ Lk][{ 2aw2/D).Cos (wt)}Sin (wt)-(w/D)(w2 –w02)}}Cos(wt)+ {[Em Sinф]/ Lk] [w(w2 –w02)/D Sin(wt) + [(2aw2/D).Cos (wt)]] (30) = [[(Em / Lk].{ { 2aw2/D).Cos (wt)}Sin (wt)-(w/D)(w2 –w02)}}Cos ф.Cos(wt)+ w02(w2 –w02)/D}Sin(wt)Sinф+[2aw2/D].Cos (wt)}Sinф] =[ Em / Lk ][[ w(w2 –w02)/D)[ (31) Sin(wt).Sinф +(2aw2/D)[Cosф.Sin(wt)+Cos(wt).Sinф]] – (34) Where B SinӨ = -w (w2 –w02)/D (35) B Cos Ө= 2aw2/D (36) And B = SQRT [[-w (w2 –w02)/D]2 + [2aw2/D]2] = SQRT [w2(w2 –w02)2/D2 + [4a2 w4/D2] = (w/D) SQRT [((w2 –w02)2 + 4a2 w2] = (w/D) SQRT D = w/ SQRT D (37) Putting the values of D in equation (37) B= w/ SQRT [4a2 w2 + (w2 –w02)2] = (w/ SQRT [4R2/4 Lkw2) + (w2 –1/LkC)2] = w/ SQRT [R2w2./ Lk +(w2 –1/LkC)2] (wt).Cosф]] (32) = [Em / Lk ][[ -w(w2 –w02)/D)[ Cos(wt+ф) +( 2aw2/D). Sin (wt+ф) =( Em / Lk) B Sin (wt+ф+Ө) Cos (33) 78 = Lk / Z (38) Putting the values of B in equation (34) and solving we get = (Em / Z) [Sin (wt+ф+Ө)] (39) Now TanӨ= - [w (w2 –w02)/D] 2 + [2aw2/D] = - (w2 –w02)/2 aw (40) Putting the value of a and w0 , we have = (1/ LkC – w2) / R w/Lk (41) = (1/wC – wLk)/R (42) (b) The other parts can be solved by taking the rest of the terms IL(2) = IL(0)[exp Cos (bt) – (a/b)exp (-at) Sin (bt)] – [Q0/b Lk. C ][exp(-at) Sin(bt)] +[Em Cosф)/Lk ].[ w(w2 –w02)/D exp (-at) Cos (bt)]-[aw/bD]( w2 +w02 ) exp(-at) Sin (bt)] + [Em Sinф]/ Lk][(-2aw2/D) exp (-at) Cos (bt)]+{ 2aw2exp(-at) Sin(bt)] w0 2(w2 –w02)/D b}[ (43) = exp (-at) Sin (bt)[-(a/b) IL(0)- Q0/bLkC – [Em Cosф)/Lk ](a/b) w(w2 +w02 )/ D +[[ Em / Lk] Sinф{2a2 w2- w0 2(w2 –w02)/D b] + exp (-at) Cos (bt)]+{[ IL(0+ Em / Lk) Cosф (w/D) ((w2 –w02)-( 2aw2/D] Em Sinф]/ Lk] = exp (-at) [A Sin (bt) + Ө2] (44) (45) Where A Cos(Ө2) = [(-a/b) IL(0)[ - Q0/bLkC – (Em Cosф)/Lk) (a/b) (w2 +w02 )/ D +[[ Em/ Lk] Sinф{2a2 w2-w 2(w2 –w02)/D b] (46) And A SinӨ2 = [IL(0+ (Em / Lk) Cosф(w/D) ((w2 –w02)-( 2aw2/D) (Em/ Lk ) Sinф] (47) 79 The equation (46) and (47) are simplified further as A Sin Ө2 = IL(0+ (Em / Lk) Cosф(w/D) ((w2 –w02)-( 2aw2/D) (Em/ Lk ) Sinф] = IL(0)- (Em / Lk) Cosф(-w/D) (w2 –w02)-( 2aw2/D) (Em/ Lk ) Sinф] = IL(0)- (Em / Lk) [w S (-w/D) ((w2 –w02)+ Sinф ( 2aw2/D)] (48) Now Let us assume (-w/D) (w2 –w02) = Y SinӨ (49) And 2aw2/D = YCosӨ And Y = SQRT [(w2/D2) (w2 –w02)2 + [4a2 w4/D2] = (w/D) SQRT [(w2 –w02)2 + 4a2 w4] = (w/D) SQRT (D) (50) Putting the value of D Y = (w/D) SQRT (D) = Lk/Z (51) Now A SinӨ2 = IL(0)- (Em / Lk) (Lk/Z) Sin (Ө +ф) (52) Similarly, A Cos(Ө2) =[[(-a/b) IL(0)[ - Q0/bLkC - (Em / Lk).aw [(w2 +w02 )/ Db]Cosф+(Em/ Lk ) { 2aw2-( w02/Db).(w2 –w02) Sinф] = (-a/b) IL(0) + 1/ bLkC[-Q0- Em a C (w/D).( w2 +w02 )Cosф + Em C{2aw2-(w02(w2 –w02)}/Db Sinф]] =(-a/b) IL(0) - Q0/ bLkC – [E// bLkC][aCw(w2 +w02 )}/D Sinф]] Now again let us assume P CosӨ = (aCw/D) (w2 +w02 ) (55) (54) 80 P SinӨ = C {2a2w2-(w2–w02)}/D (56) And P= SQRT [{(aCw/D) (w2 +w02)}2 + {2a 2w2C-C w02 (w2–w02)}/D]2] = (C/D) SQRT {( w2–w02)2(a2 w2+ w04 ) + 4 a2 w2(a2 w2+ w04 )} =( C/D) SQRT [(a2 w2+ w04 ).D] =(C/SQRT D) SQRT [(a2 w2+ w04 ). (60) Now the equation (54) can be written as follows = (-a/b) IL(0) - Q0/ bLkC – Em / bLkC[P Cos (Ө+ф)] Substituting the value of P in (61) We get = (-a/b) IL(0) - Q0/ bLkC – Em / bLkC[(C/D) SQRT [(a2 w2+ w04 ). Cos (Ө+ф)) (62) On simplification and assumption of small resistance the first term of equation (62) can be neglected. = - Q0/ bLkC – (Em / bLkC)[ Cos (Ө+ф)/wZ] (63) = (- 1/ bLkC)[ Q0+ (Em / wZ)[ Cos (Ө+ф)] (64) Now the complete equation can be written as iL = iL(1) + iL (2) (65) iL = (Em / Z) Sin (wt +ф+Ө1) + exp –(Rt /2Lk) A Sin (bt +Ө2) (66) COMPUTER PROGRAMS 1. COMPUTATION FOR CURRENT OF SERIES FERRORESONANT CIRCUIT UNDER TRANSIENT CONDITION: 81 ********************************************************************** C R1-SERIES RESISTANCE C AL-NONLINEAR INDUCTANCE C C1-CAPACITANCE C E-INPUT APPLIED VOLTAGE C Q-INITIAL CAPACITOR CHARGE C S-INITIAL CURRENT C PHI-SWITCHING ANGLE C T-TIME C R2-LOSS RESISTANCE MODELLED PARALLEL TO C INDUCTOR WRITE(*,*)R1,AL1,C1,W,E,Q,S,T,TF,EPS,PHI READ(*,*)R1,AL1,C1,W,E,Q,S,T,TF,EPS,PHI R2=1470.0 AL=AL1+ (AL1*R1/R2) R=R1+AL1/ (C1*R2) C=C1 XL= (W*AL)-(1.0/ (W*C)) Z=SQRT(R*R+XL*XL) XL=-XL THETA1=ATAN (XL/R) V1=(1.0/(AL*C))-(R/(2.0*AL))**2 V=SQRT (V1) PHI2=PHI+THETA1 B=S-(E*SIN (PHI2))/Z D=(1.0/(V*AL*C))*(-Q-(E*COS(PHI2))/(W*Z)) 50 PHI1+0.314*T+PHI+THETA1 AI1= (E*SIN (PHI1))/Z F1= (-(R*T))/ (2.0*AL)) F2=F1/1000 82 F=EXP (F2) AI2=F*B*COS (.001*T*V)+F*D*SIN(.001*T*V) AI=AI1+AI2 VL=AI*XL WRITE (*,*) T, AI, VL T=T+EPS IF (T.GT.TF) GO TO 100 GO TO 50 100 STOP END COMPUTER PROGRAM –2 NEWTON-RAPHSON METHOD FOR DETERMINATION OF EXACT TIME C R1-SERIES RESISTANCE C AL1-NONLINEAR INDUCTANCE C C1-CAPACITANCE C E-INPUT VOLTAGE APPLIED SUDDENLY C Q-INITIAL CHARGE IN THE CAPACITOR C S-INITIAL CURRENT C PHI-SWITCHING ANGLE C G=LIMITING VALUE OF CURRENT WRITE(*,*)R1,AL1,C1,W,E,Q,S,T,G,EPS,PHI READ(*,*)R1,AL1,C1,W,E,Q,S,T,G,EPS,PHI,AI R2=1470.0 AL=AL1+ (AL1*R1/R2) R=R1+AL1/ (C1*R2) C=C1 XL= (W*AL)-(1.0/(W*C)) Z=SQRT(R*R+XL*XL) XL=-XL 83 THETA1=ATAN (XL1/R) V1=(1.0/(AL*C))-(R/(2.0*AL))**2 V=SQRT (V1) PHI2=PHI+THETA1 B=S-(E*SIN (PHI2))/Z D=(1.0/(V*AL*C))*(-Q-(E*COS(PHI2))/(W*Z)) 100 PHI1=0.314*T+PHI+THETA1 AI1= (E*SIN (PHI1))/Z F1= (-(R*T)/ (2.0*AL)) F2=F1/1000 F=EXP (F2) AI2=F*B*COS (.001*T*V) +F*D*SIN (.001*T*V) DI1= (W*E*COS (PHI1))/Z DI2= (F*V*COS)(.001*V*T)*D)-(F*V*SIN(.01*V*T)*B) DI3= ((R/(2.0*AL))*F)*(SIN(.001*V*T)D+COS(.001*V*T)*B) DI=DI1+DI2-DI3 DELT= (G-AI)/DI IF (ABS (G-AI).LE.EPS GOTO 50 T1=T+DELT T=T1 GOTO 100 WRITE (*.*) T, AI 50 STOP 51 END *************************************************************** COMPUTER PROGRAM -3 TO DERIVE I.C WITH OPTIMUM NO. OF SEGMENTS 84 C PIECEWISE IC OPTIMISATION DIM V(30),L(30),S(30),K(30),T(30).G(30),J(30),D(30) DIM P(30),Q(30),A(30),B(30),C(30),M(30),V(30),I(30) INPUT E5 FOR N=1 TO13 READ U (N) DATA 0,100,140,160,180,200,240,250,280,290,300 NEXT N FOR N=1 TO 13 READ M (N) DATA 0, 0.135, 0.215, 0.275, 0.374, 0.505, 0.68, 0.94, 1.125, 1.325 DATA 1.85, 2.25, 2.85 NEXT N V (1) =0 L (1) =0 J (1) =0 P (1) =0 T (1) =0 Q (1) =0 G (1) =0 R=2 N=2 330 340 360 420 500 S (N) = (M (N)-M (N-1))/ (U (N)-U (N-1)) V(R) =U (N) I(R) =M (N) GOSUB 650 GOSUB 780 IF R>2 THEN 420 R=R+1 N=N+1 GOTO 330 E1=V(R-1) + (1/2.0)*(V(R)-V(R-1)) V(R) =E1 GOSUB 650 GOSUB 870 E3=S (N)*(V(R)-V(R-1)) +I(R-1) E4= (E2-E3)/E3 IF ABS (E4) <E5 THEN 500 GOTO 550 V(R) =2.0*E1-V(R-1) 85 550 580 580 610 650 770 770 700 800 I(R) =S (N)*(V(R)-V(R-1)) +I(R-1) L(R) = (SQRT (2.0)*V(R))/ (2200.0/7.0) J(R) =K(R)*(L(R)-L(R-1)) +J(R-1) IF ABS (V(R)-U (N)) <1E-2 THEN 580 R=R+1 GO TO 340 V(R) =E1 I(R) =E3 GO TO 360 V(R) =E1 I(R) =E3 GO TO 360 N=N+1 IF N>13 THEN 610 R=R+1 GO TO 330 PRINT "NO OF SEGMENTS="(R-1) PRINT "ERROR TOLERANCE="E5 PRINT END.V.RMS*.*"SLOPE*,*LAMDA*,*I.CURRENT*,* FOR N=2 TO R PRINT V (H), K (H), L (H), J (H) NEXT H STOP L(R)=(SQRT(2.0)*V(R))/(2200.0/7.0) IF R>2 THEN 700 IF V(R) > U (N) THEN 700 K(R) = (SQRT (2.0)*I)) /L(R) PRINT K (R) GOTO 770 GOSUB 950 T (R) = (11.0/7.0) –P(R-1))) G (R) = - (1/2.0)* (SIN (2 * P(R-1))) G (R) =- COS (P(R-1)) D (R) = ((J(R-1)*2)*T(R) A5 = (((L (R) *2)/2.0)*(T(R)-Q(R)) A6= 2.0 *L(R) *L(R-1)* G(R)* ((L(R -1)) **2) * T(R)) A(R) =A5*A6 B(R )=-2.0 * (J(R-1)) * (L( R )*G( R )*L( R )* L (R-1)*T( R )) RETURN IF R>2 THEN 800 GOTO 860 F3=0 FOR H=2 TO (N-1) F4 = (K (H)*2)4A (H)*K (H) * B (H)*D (H) F3 = F3*F4 86 NEXT N C(R) =F3*D(R)-(11.0/7.0)*I(R) **2 K( R ) = (-B( R )*SQRT(B( R )*B(R )-( 4.D* A (R )*I( R))))/(2.0*A( R )) 860 RETURN 870 F5=0 FOR H=2 TO R F6= ((K (H) **2))*A (H) +K (H)*B (H) +D (H) F5=F5+F6 NEXT H E2=SQRT ((7.0/11.0)*F5) RETURN 950 FOR I =2 TO (R-1) P(X) =ATAN ((L(X)/L(R))/SQRT (1-((L(X)/L(R)) **2)))) T(X) = P(X)-P(X-1) G(X)=(1.0/2.0)*SIN(2.0*P(X))-(1.0/2.0)*SIN(2.0*P(X-1)) G(X) =COS (P(X))-COS (P(X-1) J(X) =K(X)*(L(X)-L(X-1)) +J(X-1) D(X) =J(X-1)*J(X-1)*T(X) A1= ((L(R)*L(R))/2.0)*(T(X)-Q(X)) A2=2.0*L(R)*L(X-1)*G(X) A3=L(X-1) * L(X-1)*T(X) A(X) =A1+A2+A3 B(X) =-2*J(X-1)*(L(R)*G(X) +L(X-1)*t(X)) NEXT X RETURN *************************************************************** 87