GEK-98000B-P Power/Vac Electrically Operated 15kV Ground
... the phase conductors or circuit parts before touching them. Where it could be reasonably anticipated that the conductors or circuit parts being deenergized could contact other exposed energized conductors or circuit parts, apply ground connecting devices rated for the available fault duty. B. Safet ...
... the phase conductors or circuit parts before touching them. Where it could be reasonably anticipated that the conductors or circuit parts being deenergized could contact other exposed energized conductors or circuit parts, apply ground connecting devices rated for the available fault duty. B. Safet ...
P3 10 Motor Effect
... To gain full marks in this question you should write your ideas in good English. Put them into a sensible order and use the correct scientific words. Some electrical circuits are protected by a circuit breaker. These switch the circuit off if a fault causes a larger than normal current to flow. The ...
... To gain full marks in this question you should write your ideas in good English. Put them into a sensible order and use the correct scientific words. Some electrical circuits are protected by a circuit breaker. These switch the circuit off if a fault causes a larger than normal current to flow. The ...
ADM1169 数据手册DataSheet 下载
... 4 selectable input attenuators allow supervision of supplies to 14.4 V on VH 6 V on VP1 to VP3 (VPx) 4 dual-function inputs, VX1 to VX4 (VXx) High impedance input to supply fault detector with thresholds between 0.573 V and 1.375 V General-purpose logic input 8 programmable driver outputs, PDO1 to P ...
... 4 selectable input attenuators allow supervision of supplies to 14.4 V on VH 6 V on VP1 to VP3 (VPx) 4 dual-function inputs, VX1 to VX4 (VXx) High impedance input to supply fault detector with thresholds between 0.573 V and 1.375 V General-purpose logic input 8 programmable driver outputs, PDO1 to P ...
Atmel ATA5279/ATA5279C Antenna Driver for Multiple Antennas Features DATASHEET
... The structure above can be found in each of the six channels of the Atmel® ATA5279. As soon as the diagnosis mode is engaged, all channels are operated in this way. On the channel that is actually selected, the setting of the switches can be changed with the Set Coil Current command and the status o ...
... The structure above can be found in each of the six channels of the Atmel® ATA5279. As soon as the diagnosis mode is engaged, all channels are operated in this way. On the channel that is actually selected, the setting of the switches can be changed with the Set Coil Current command and the status o ...
Aalborg Universitet tester
... The Non-Destructive Test (NDT) is a cost-effective solution used to test high power semiconductor devices at the edges of their Safe Operating Areas (SOA). The presence of the protection circuit allows preventing the failure of the Device Under Test (DUT) at the occurrence of any possible instable b ...
... The Non-Destructive Test (NDT) is a cost-effective solution used to test high power semiconductor devices at the edges of their Safe Operating Areas (SOA). The presence of the protection circuit allows preventing the failure of the Device Under Test (DUT) at the occurrence of any possible instable b ...
to the HiSat-15 Instruction Manual
... chips, broken skirts, flash burns) are poor predictors of the dielectric condition of these insulators. Such types of damage affect the flash over withstand capability of the insulator but do not usually affect its resistance value. The type of physical damage which does affect an insulator’s resist ...
... chips, broken skirts, flash burns) are poor predictors of the dielectric condition of these insulators. Such types of damage affect the flash over withstand capability of the insulator but do not usually affect its resistance value. The type of physical damage which does affect an insulator’s resist ...
File - ELECTRICAL ENGINEERING DEPT, DCE
... The controllability of current-flow through HVDC rectifiers and inverters, their application in connecting unsynchronized networks, and their applications in efficient submarine cables mean that HVDC cables are often used at national boundaries for the exchange of power (in North America, HVDC conne ...
... The controllability of current-flow through HVDC rectifiers and inverters, their application in connecting unsynchronized networks, and their applications in efficient submarine cables mean that HVDC cables are often used at national boundaries for the exchange of power (in North America, HVDC conne ...
Englische Musterspec. für 8DN9
... 12. All gas compartments shall be fitted with filter material which absorbs the residual and entering moisture inside the high-voltage enclosure. Filters in gas compartments with switching devices must also be capable to absorb the gas decomposition products resulting from the switching arc. 13. Sin ...
... 12. All gas compartments shall be fitted with filter material which absorbs the residual and entering moisture inside the high-voltage enclosure. Filters in gas compartments with switching devices must also be capable to absorb the gas decomposition products resulting from the switching arc. 13. Sin ...
Phase-shifting Transformer Modeling in PSS®E
... adjusting the phase angle of the voltages at the phase-shifting transformer terminals. Phase-shifting transformers are also known as phase angle regulating (PAR) transformers. Phase-shifting transformers built for transmission grids are generally a three-phase, two-terminal pair design. The terminal ...
... adjusting the phase angle of the voltages at the phase-shifting transformer terminals. Phase-shifting transformers are also known as phase angle regulating (PAR) transformers. Phase-shifting transformers built for transmission grids are generally a three-phase, two-terminal pair design. The terminal ...
AVTRON ACCel500 COMMON BUS DC INVERTERS
... factory before they are delivered to the customer. However, after unpacking the product, check that no sign of transportation damage is to be found on the product and that the delivery is complete (compare the type designation of the product to the code below; see Table 1-1). If the drive has been d ...
... factory before they are delivered to the customer. However, after unpacking the product, check that no sign of transportation damage is to be found on the product and that the delivery is complete (compare the type designation of the product to the code below; see Table 1-1). If the drive has been d ...
A Complete Electrical Hazard Classification
... of electrical equipment. Standards such as the National Electrical Code (NEC) [1] and those developed by Underwriters Laboratory (UL) strove to prevent fire and to protect the user against exposure to electric shock. Well known examples of design requirements to protect the user include the equipmen ...
... of electrical equipment. Standards such as the National Electrical Code (NEC) [1] and those developed by Underwriters Laboratory (UL) strove to prevent fire and to protect the user against exposure to electric shock. Well known examples of design requirements to protect the user include the equipmen ...
service and metering guide
... equipment and to the sides and back where access is required. Additional requirements are listed in CEC Rule 2-308 and 2-312; such as electrical rooms are not to be located in a bathroom, closet or stairway. In addition, a disconnect switch must be located in the same room, on the supply side, and a ...
... equipment and to the sides and back where access is required. Additional requirements are listed in CEC Rule 2-308 and 2-312; such as electrical rooms are not to be located in a bathroom, closet or stairway. In addition, a disconnect switch must be located in the same room, on the supply side, and a ...