• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
COLLEGE OF ENGINEERING INSTITUTION OF ENGINEERS
COLLEGE OF ENGINEERING INSTITUTION OF ENGINEERS

Optimal Design for Resonant Power Transformer
Optimal Design for Resonant Power Transformer

... A request because the working temperature is too high by skin effect. We use the extraordinary wire to make the two indent resonant transformer as figure 5. The 0.1mm isolation wire small then 0.2mm can pass class A request. The energy is unable to produce any conversion if the frequency is working ...
Winding Capacitance and Leakage Inductance
Winding Capacitance and Leakage Inductance

Swimming Pool Electrical Safety
Swimming Pool Electrical Safety

... Installation. Where the luminaire operates over the low voltage contact limit, the junction box location shall comply with (a) and (b). Where the luminaire operates at the low voltage contact limit or less, the junction box location shall be permitted to comply with (c). (a) Vertical Spacing. The ju ...
Microelectronic Circuit Design
Microelectronic Circuit Design

... Check of Results: Note that vTH=iNRth and this can be used to check the calculations: iNRth=(2.55 mS)vs(282 ) = 0.719vs, accurate within round-off error. While the two circuits are identical in terms of voltages and currents at the output terminals, there is one difference between the two circuits. ...
Single-Ended Signal Conditioning Circuit for
Single-Ended Signal Conditioning Circuit for

... Table 2 lists overcurrent conditions and their potential causes. When considering an IGBT overcurrent protection scheme, evaluate two important factors. The first factor is what type of overcurrent protection the system must provide and how the system can shut down. The second factor is the control ...
Microsoft Word - ATT-TP-76450_15
Microsoft Word - ATT-TP-76450_15

... and assemblies intended for installation in network equipment buildings, equipment areas within buildings, electronic equipment enclosures such as controlled environmental vaults, outside electronic equipment cabinets, and customer locations. 1.4 Pre-assembled versus Field Assembled Network Equipmen ...
7 CONTROL AND PROTECTION OF HYDRO ELECTRIC STATION
7 CONTROL AND PROTECTION OF HYDRO ELECTRIC STATION

... Microprocessor relaying has gained widespread acceptance among both utilities and consumers. The relay functions are the same as those in electromechanical and solid-state electronic relaying, but microprocessor relays have features that provide added benefits. Microprocessor relays may have some di ...
Dynamic Fine-Grain Leakage Reduction Using Leakage
Dynamic Fine-Grain Leakage Reduction Using Leakage

... energy to switch between active and inactive states. By sizing the sleep transistor [13], boosting the gate voltage for the sleep transistor [11], or forward-biasing the sleep transistor [16], the delay penalty can be reduced in exchange for greater sleep leakage currents and increased deactivation ...
code changes power point
code changes power point

... • (C)(1) 300 mm (12 in.) for surface-mounted incandescent or LED luminaires…or on the ceiling. • (C)(3) 150 mm (6 in.) for recessed incandescent or LED luminaires…or the ceiling. • (C)(5) Surface-mounted fluorescent or LED luminaires shall be permitted to be installed in the storage space where iden ...
Guide to Fuse Selection
Guide to Fuse Selection

... and vice versa. > Sufficient airflow and ventilation should be considered when designing fuses in the application. > Schurter fuseholder and fused module datasheets have power acceptance ratings which show how much heat dissipation it can withstand safely. > If a fuse dissipates more heat than the f ...
Using VRC_CTL to Control an External VDD_LV Supply on the
Using VRC_CTL to Control an External VDD_LV Supply on the

Liebert Series 610 UPS Installation Manual - 100-225kVA, 60Hz, Three Phase Multi-Module
Liebert Series 610 UPS Installation Manual - 100-225kVA, 60Hz, Three Phase Multi-Module

... This equipment contains several circuits that are energized with high voltage. Only test equipment designed for troubleshooting should be used. This is particularly true for oscilloscopes. Always check with an AC and DC voltmeter to ensure safety before making contact or using tools. Even when the p ...
This is a shot of 48 circuit boards available in the classroom for
This is a shot of 48 circuit boards available in the classroom for

Swimming Pool Electrical Safety
Swimming Pool Electrical Safety

... Installation. Where the luminaire operates over the low voltage contact limit, the junction box location shall comply with (a) and (b). Where the luminaire operates at the low voltage contact limit or less, the junction box location shall be permitted to comply with (c). (a) Vertical Spacing. The ju ...
Moeller software tools
Moeller software tools

... General information  The xSpider is intended primarily for designers, computational and checking engineers  Design of networks TN/TT/IT of various voltage systems up to 1000 V  Design of radial or meshed networks  Design of networks supplied from one or more different power sources  All calcua ...
Implementation and Applications of Current
Implementation and Applications of Current

... If a completely floating programable current source is needed, use the circuit shown in Figure 16. It is basically the same as the current source shown in Figure 12 except that R2 is driven by a MOSFET. Since no current flows in the gate of the MOSFET or the inputs of the op amp, all current that en ...
Moeller software tools - X-Spider
Moeller software tools - X-Spider

... General information  The xSpider is intended primarily for designers, computational and checking engineers  Design of networks TN/TT/IT of various voltage systems up to 1000 V  Design of radial or meshed networks  Design of networks supplied from one or more different power sources  All calcua ...
300 Watt Pure Sine Wave DC-AC Inverter PST-30S-12A PST-30S-24A
300 Watt Pure Sine Wave DC-AC Inverter PST-30S-12A PST-30S-24A

... ring or the like to metal and thus cause a severe burn. • If you need to remove a battery, always remove the ground terminal from the battery first. Make sure that all the accessories are off so that you do not cause a spark Page 2 ...
Definition of Selective Coordination
Definition of Selective Coordination

... documented and made available to those authorized to design, install, inspect, maintain, and operate the system.” New for elevators (620.62), emergency (700.28), legally required standby (701.27), and critical operations power systems (708.54) ...
PowlVac 5-15kV Metal-Clad Switchgear Guide
PowlVac 5-15kV Metal-Clad Switchgear Guide

... Control power and control circuit wiring shall be connected to the power circuit breaker by means of a 16 pin front connected umbilical cord and plug. This plug shall be mechanically interlocked. The plug shall not be removable while the circuit breaker is in the connected position. The circuit brea ...
Electrical Safety Awareness Training
Electrical Safety Awareness Training

... • Can not recognize or differentiate energized and de-energized electrical contacts. • Has general knowledge of electrical safety to aid in recognition of potentially unsafe conditions. Facilities Management UW-Eau Claire ...
MultyMass MMC2 - badger meter europa gmbh
MultyMass MMC2 - badger meter europa gmbh

... General information and notes for the reader Read these instructions carefully prior to installing and commissioning the device. These instructions are an important part of the product and must be kept for later use. These instructions are intended as an overview and do not contain detailed informat ...
Manual (Units installed prior to Nov 2006)
Manual (Units installed prior to Nov 2006)

... (c) any Product which has not been operated and maintained in accordance with normal practice and in conformity with recommendations and published specifications of company; and, (d) any Products, component parts or accessories manufactured by others but supplied by Company (any claims should be sub ...
dA Chapter 3: Electricity and Magnetism Duration: 10 days Day 1
dA Chapter 3: Electricity and Magnetism Duration: 10 days Day 1

... You have just made a magnet by using electricity. When you disconnected one end of the wire from the battery, the current did not flow anymore. The nail could no longer attract the pins. Its magnetic force was gone. An electromagnet can have magnetic force only when electric current is flowing throu ...
< 1 ... 25 26 27 28 29 30 31 32 33 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.