• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
examination branch question bank
examination branch question bank

Energy Measuring Unit EcoMonitorLight Series
Energy Measuring Unit EcoMonitorLight Series

... upper/lower limits monitoring, alarm output and pulse input/output, in addition to the Standard Model features  ② Standard Model: For customers who "want to start measuring energy in a simple and low-cost manner". ...
Grid-tie Transformerless Solar Inverter
Grid-tie Transformerless Solar Inverter

The Lineman`s and Cableman`s Field Manual
The Lineman`s and Cableman`s Field Manual

Negotiated Customer Connection Contract
Negotiated Customer Connection Contract

... The Customer must ensure that: 4.1.1 the electrical plant in its facility complies with the relevant Australian Standards as applicable at the time of first installation of that electrical plant in the facility; 4.1.2 circuit breakers provided to isolate the Customer’s facilities from Energex’s faci ...
GEM Plus - GE Industrial Solutions
GEM Plus - GE Industrial Solutions

DATA SHEET Tytan II D0-63-3/V
DATA SHEET Tytan II D0-63-3/V

Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS
Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS

... fault conditions and evaluate the above relay’s loadability at 0.85 per unit voltage and a power factor angle of 30 degrees. ...
High Speed Layout Design Guidelines This application note
High Speed Layout Design Guidelines This application note

Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS
Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS

... above, except for switch-on-tofault schemes, the beginning of the first calendar quarter following ninety (90) days after the date of approval by the Commission. For requirements R1 and R2 for transmission lines operated at 100 kV to 200 kV as identified by the ISO as critical to the reliability of ...
Section 3 GDT Telecom Applications Protection Examples
Section 3 GDT Telecom Applications Protection Examples

... Telecom equipment should be protected from overvoltage conditions using GDTs, MOVs, or silicon devices such as SIDACtors or TVS diodes. Gas Discharge Tubes / Surge Arresters are mostly used for Primary Protection against transients caused by lightning. Secondary Protection applications traditionally ...
Training Agenda
Training Agenda

Metal-Enclosed Switchgear
Metal-Enclosed Switchgear

... The Digitrip 520MCV relay includes an Arcflash Reduction Maintenance System™ (ARMS) feature that may be activated at the breaker or from remote. When activated, the ARMS feature lowers the available arc flash energy at the connected downstream device by faster clearing of the downstream fault The Di ...
EASA Proposed CM-ES-001
EASA Proposed CM-ES-001

... A means of indication should be provided to enable the cabin crew to identify which outlets are in use. If multiple de-powering switches are used in the design, consideration should be given to including a system status indicator at each switch location. This feature would allow cabin crew members t ...
Article 690 - Solar Photovoltaic (PV) Systems
Article 690 - Solar Photovoltaic (PV) Systems

lesson 1
lesson 1

... THE POWER RATINGS OF TRIMMING POTENTIOMETERS ARE USUALLY MORE THAN ADEQUATE FOR MOST VOLTAGE DIVIDER APPLICATIONS WHERE THE POWER IS DISSIPATED EVENLY OVER THE ENTIRE LENGTH OF THE ELEMENT UNDER ALL CIRCUMSTANCES. KEEP IN MIND, HOWEVER, THAT THE STATED POWER RATING IS FOR THE ENTIRE RESISTANCE ELEME ...
Electrical Hazards
Electrical Hazards

... Illumination (Over 600 Volts) • Adequate illumination must be provided for all working spaces around electrical equipment. • The lights and switches must be arranged so that persons making repairs or turning on lights wont contact live ports. ...
installation manual
installation manual

Liebert Series 610 UPS Installation Manual - 500-750kVA, 60Hz, Three Phase Single-Module
Liebert Series 610 UPS Installation Manual - 500-750kVA, 60Hz, Three Phase Single-Module

... This equipment contains several circuits that are energized with high voltage. Only test equipment designed for troubleshooting should be used. This is particularly true for oscilloscopes. Always check with an AC and DC voltmeter to ensure safety before making contact or using tools. Even when the p ...
User Manual
User Manual

... Working status is divided into 3 kinds: normal working status, faulty status, and termination status. 1. Normal Working Status There are two modes: standby status and running status for this stage. Under this mode, the system is running in normal status. Meanwhile tracking all functioning data to ke ...
PHASE-COMPARISON CARRIER-PILOT RELAYS
PHASE-COMPARISON CARRIER-PILOT RELAYS

LCM600 Series - Artesyn Embedded Technologies
LCM600 Series - Artesyn Embedded Technologies

medium-voltage switchgear
medium-voltage switchgear

Metal-layer capacitors in the 65nm CMOS process and the
Metal-layer capacitors in the 65nm CMOS process and the

... would be almost identical under the same RC time constant. For emphasizing the impact of gate leakage issue, only MOM capacitor was composed in the power-rail ESD clamp circuit to observe the gate leakage issue as compared to the thin-oxide MOS capacitor. Thus, two power-rail ESD clamp circuits with ...
simplest chaotic circuit
simplest chaotic circuit

... Fig. 6. In this figure, we compare experimental versus theoretical attractors. The top two sets of attractor plots y(t) (iL (t), current through the inductor) versus x(t) (vC (t), voltage across the capacitor). The axes scales for the experimental attractor on the top-left are 0.5 V/division. Hence f ...
< 1 ... 24 25 26 27 28 29 30 31 32 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report