• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
20130123 PER Presentation
20130123 PER Presentation

...  It is NERC’s policy and practice to obey the antitrust laws and to avoid all conduct that unreasonably restrains competition. This policy requires the avoidance of any conduct that violates, or that might appear to violate, the antitrust laws. Among other things, the antitrust laws forbid any agre ...
Memristor The Advancement in Fundamental Circuit Elements
Memristor The Advancement in Fundamental Circuit Elements

Untitled - Delmarva Power
Untitled - Delmarva Power

... Upper Marlboro, MD 20772 ...
BDTIC PrimeSTACK
BDTIC PrimeSTACK

... Each of these family members consists of standard production components. Like kit-set, required components are added or omitted. Further, PrimeSTACKs are available as standard and traction versions. If not mentioned otherwise, reference is made to the standard version hereafter. ...
Circuit Component SLAC for AXE 10
Circuit Component SLAC for AXE 10

a 1 pC Charge Injection, 100 pA Leakage CMOS ADG604
a 1 pC Charge Injection, 100 pA Leakage CMOS ADG604

... over the specified analog signal range. Source Leakage Current with the Switch “OFF” Drain Leakage Current with the Switch “OFF” Channel Leakage Current with the Switch “ON” Analog Voltage on Terminals D, S Maximum Input Voltage for Logic “0” Minimum Input Voltage for Logic “1” Input Current of the ...
ETPD: The Facts and The FAQs
ETPD: The Facts and The FAQs

ADG733 数据手册DataSheet下载
ADG733 数据手册DataSheet下载

... Active low device enable Analog Voltage on Terminals D and S Ohmic Resistance between D and S On Resistance Match between any Two Channels (i.e., RONmax and RONmin) Flatness is defined as the difference between the maximum and minimum value of on resistance as measured over the specified analog sign ...
Electrical Overstress EOS
Electrical Overstress EOS

... The damage caused by EOS is typically so extensive that the origin of the problem can not be determined. An initial small voltage perturbation can cascade into a large event and cause damage that overwhelms the original damage site. The analysis report will identify which package pins are damaged an ...
Liebert Series 610 UPS Installation Manual - 1000kVA, 60Hz, Three Phase Multi-Module
Liebert Series 610 UPS Installation Manual - 1000kVA, 60Hz, Three Phase Multi-Module

... This equipment contains several circuits that are energized with high voltage. Only test equipment designed for troubleshooting should be used. This is particularly true for oscilloscopes. Always check with an AC and DC voltmeter to ensure safety before making contact or using tools. Even when the p ...
Ans: b
Ans: b

... 3. The direction of conventional current is a. first from negative terminal to positive terminal and vice versa b. First from positive terminal to negative terminal and vice versa c. From negative terminal to positive terminal only d. From positive terminal to negative terminal only Ans: d 4. If the ...
Zero-current zero-voltage transition inverters with
Zero-current zero-voltage transition inverters with

17B Electromagnets
17B Electromagnets

Out-of-Step Protection for Generators
Out-of-Step Protection for Generators

... In general, the protection normally applied in the generator zone, such as differential relaying, time delay system backup etc., will not protect a generator during a loss of synchronism. The loss of excitation relay may provide some degree of protection but can not be relied on to detect generator ...
Fuse Characteristics, Terms and Consideration Factors
Fuse Characteristics, Terms and Consideration Factors

... within the fuse series. FUSEHOLDERS: In many applications, fuses are installed in fuseholders. These fuses and their associated fuseholders are not intended for operation as a “switch” for turning power “on” and “off “. INTERRUPTING RATING: Also known as breaking capacity or short circuit rating, th ...
ezCircuit examples
ezCircuit examples

Name
Name

... Gradually turn the paper until the long line matches the direction “North” as shown by the compass. Tape the paper down to the table. Remove the compass. d) Using a loop of tape, fasten the compass to the middle of the rectangle with “North” facing one short side. Slide this into the tube so that yo ...
ADG786 数据手册DataSheet下载
ADG786 数据手册DataSheet下载

... process that provides low power dissipation yet gives high switching speed, very low on resistance, high signal bandwidths and low leakage currents. On resistance is in the region of a few ohms, is closely matched between switches and very flat over the full signal range. These parts can operate equ ...
3. manual mode
3. manual mode

... COM: This is the Common terminal. The DC Voltage applied to this terminal would appear at the output terminals Cnn if output Current-Sourcing Transistor is turned ON. Cnn: These are the Bank On / Off command terminals. When a specific capacitor bank is to be turned on, it connects the Current-Sourci ...
GENERATOR PROTECTION
GENERATOR PROTECTION

... Types of Generator Ground Fault Damage  Following pictures show stator damage after an internal ground fault  This generator was high impedance grounded, with the fault current less than 10A  Some iron burning occurred, but the damage ...
Fuse Characteristics, Terms and
Fuse Characteristics, Terms and

Electrical Energy Systems (Power Applications of Electricity)
Electrical Energy Systems (Power Applications of Electricity)

... to set down into a document (especially circuit diagrams), and vita brevis, so as usual I have been quite selective in what I have chosen to include here. My emphasis has been on topics that are/were:  personally relevant and practical (such as household electrical configurations)  interesting or ...
PowerFlex 750-Series Power Jumpers Installation
PowerFlex 750-Series Power Jumpers Installation

... • AC fed ungrounded • Impedance grounded • B phase ground • DC fed from an active converter Connected ...
62-0388 Class 1000 Meter Installation Manual
62-0388 Class 1000 Meter Installation Manual

The Transfrormer
The Transfrormer

... the same direction in the core that forms the common magnetic path. For the same reason, terminals 2 and 4 are identical. If these two windings are linked by a common time-varying flux, voltages will be induced in these windings such that, if at a particular instant the potential of terminal 1 is po ...
< 1 ... 31 32 33 34 35 36 37 38 39 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report