Eaton 9E
... round hole terminal open. Then insert the wire into the round hole. Then pull out the screw driver. Connect the two wires of the cable to terminals 5 and 6 (for version 9E6Ki), 7 and 8 (for versions 9E10Ki, 9E10KiXL, 9E15Ki, 9E15KiXL, 9E20Ki, 9E20KiXL) to be able to remotely shut off the UPS. ...
... round hole terminal open. Then insert the wire into the round hole. Then pull out the screw driver. Connect the two wires of the cable to terminals 5 and 6 (for version 9E6Ki), 7 and 8 (for versions 9E10Ki, 9E10KiXL, 9E15Ki, 9E15KiXL, 9E20Ki, 9E20KiXL) to be able to remotely shut off the UPS. ...
WECC-0113 FACs Request to Retire Variances FAC
... circuits of a multiple-circuit tower line (covered by Category P7). As such, it made sense to apply the same performance criteria to both classes of contingencies. However, actual performance data for 230-kV and above transmission lines in the Western Interconnection indicate that the average outage ...
... circuits of a multiple-circuit tower line (covered by Category P7). As such, it made sense to apply the same performance criteria to both classes of contingencies. However, actual performance data for 230-kV and above transmission lines in the Western Interconnection indicate that the average outage ...
μ PD166020T1F Data Sheet
... • Built-in diagnostic function - Proportional load current sensing - Defined fault signal in case of abnormal load condition • Under voltage lock out • Reverse battery protection by self turn on of N-ch MOSFET • Small multi-chip package: JEDEC 5-pin TO-252 (MSL: 3, profile acc. J-STD-20C) • AEC Qual ...
... • Built-in diagnostic function - Proportional load current sensing - Defined fault signal in case of abnormal load condition • Under voltage lock out • Reverse battery protection by self turn on of N-ch MOSFET • Small multi-chip package: JEDEC 5-pin TO-252 (MSL: 3, profile acc. J-STD-20C) • AEC Qual ...
Third Rail Fuse Link Application Guide
... To ensure continuity of supply at junctions (points or crossovers), and for safety at stations, the third rail will be on the opposite side of the track from the platform. The third rail usually alternates between sides of the train as shown on Figure 2. To allow for this there are pick up shoes on ...
... To ensure continuity of supply at junctions (points or crossovers), and for safety at stations, the third rail will be on the opposite side of the track from the platform. The third rail usually alternates between sides of the train as shown on Figure 2. To allow for this there are pick up shoes on ...
Stakeholder Comment and Replies Matrix AESO AUTHORITATIVE DOCUMENT PROCESS Alberta Reliability Standard
... further clarity be added on R1.12. It is not clear which apparent impedance the AESO is referring to. Typically, if there is concern between line protection and line load capabilities, it is with the Zone 3 reach of the line protection. Is the AESO recommending that the zone reach causing concern be ...
... further clarity be added on R1.12. It is not clear which apparent impedance the AESO is referring to. Typically, if there is concern between line protection and line load capabilities, it is with the Zone 3 reach of the line protection. Is the AESO recommending that the zone reach causing concern be ...
When power is supplied by V or V , the
... companion host processor circuit and power for the smart card. The 73S8009C can operate from a single 2.7 V to 6.5 V source supply, or a combination of battery power (4.0 V to 6.5 V) and USB power (4.4 V to 5.5 V). The 73S8009C supports 5 V, 3 V, and 1.8 V smart cards. The smart card signals for RST ...
... companion host processor circuit and power for the smart card. The 73S8009C can operate from a single 2.7 V to 6.5 V source supply, or a combination of battery power (4.0 V to 6.5 V) and USB power (4.4 V to 5.5 V). The 73S8009C supports 5 V, 3 V, and 1.8 V smart cards. The smart card signals for RST ...
DRV8881 - Texas Instruments
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
Emergency Services Personnel
... • Short circuit: Electricity taking a short-cut, for example from an overhead line or any other electrical equipment to the ground, instead of flowing normally as intended. Sometimes the short-cut can involve a large flow of electric current that should automatically disconnect the electrical equip ...
... • Short circuit: Electricity taking a short-cut, for example from an overhead line or any other electrical equipment to the ground, instead of flowing normally as intended. Sometimes the short-cut can involve a large flow of electric current that should automatically disconnect the electrical equip ...
Electrical Safety Program
... Electric Shock and Burns. An electric shock occurs when electric current passes through the body. This can happen when touching an energized part. If the electric current passes across the chest or head, death can result. At high voltages, severe internal and external burns can result from current p ...
... Electric Shock and Burns. An electric shock occurs when electric current passes through the body. This can happen when touching an energized part. If the electric current passes across the chest or head, death can result. At high voltages, severe internal and external burns can result from current p ...
VEGABAR 81, 82 and 83
... Lower output voltage of the power supply unit under nominal load (e.g. with a sensor current of 20.5 mA or 22 mA in case of fault) Influence of additional instruments in the circuit (see load values in chapter "Technical data" of the operating instructions of the respective instrument) ...
... Lower output voltage of the power supply unit under nominal load (e.g. with a sensor current of 20.5 mA or 22 mA in case of fault) Influence of additional instruments in the circuit (see load values in chapter "Technical data" of the operating instructions of the respective instrument) ...
No Slide Title
... If the assumption is : all field devices take 20mA all are located at the remote end of the IS trunk typically, the number of devices which can be powered from a IIC power supply is 5 at the end of a 600m trunk The corresponding IIB power supply will supply 13 devices at the end of a 300m ...
... If the assumption is : all field devices take 20mA all are located at the remote end of the IS trunk typically, the number of devices which can be powered from a IIC power supply is 5 at the end of a 600m trunk The corresponding IIB power supply will supply 13 devices at the end of a 300m ...
Electricity 15
... These are not associated with DC shocks and explain why an AC supply at a given voltage is more dangerous than a DC supply of the same voltage. At a given voltage, say 100v, the DC supply is a constant 100v, whereas the AC supply actually peaks at much higher (approx. 140v) as when we are talking ab ...
... These are not associated with DC shocks and explain why an AC supply at a given voltage is more dangerous than a DC supply of the same voltage. At a given voltage, say 100v, the DC supply is a constant 100v, whereas the AC supply actually peaks at much higher (approx. 140v) as when we are talking ab ...
Phase Distance & Power Transformers
... Capacitive Voltage Transformers (CVTs) create certain problems for fast distance relays applied to systems with high Source Impedance Ratios (SIRs): > CVT-induced transient voltage components may assume large magnitudes (up to 30-40%) and last for a comparatively long time (up to about 2 cycles) > 6 ...
... Capacitive Voltage Transformers (CVTs) create certain problems for fast distance relays applied to systems with high Source Impedance Ratios (SIRs): > CVT-induced transient voltage components may assume large magnitudes (up to 30-40%) and last for a comparatively long time (up to about 2 cycles) > 6 ...
AP3156
... disable time TOFF(max), then the AP3156 will be turned off and enters the shutdown mode. Setting the SDI pin switching from Low to High will re-enable the AP3156 and leave the shutdown mode. If the SDI pin is held on for a time duration over TSEP, then an end of a sequence (EOS) occurs with a number ...
... disable time TOFF(max), then the AP3156 will be turned off and enters the shutdown mode. Setting the SDI pin switching from Low to High will re-enable the AP3156 and leave the shutdown mode. If the SDI pin is held on for a time duration over TSEP, then an end of a sequence (EOS) occurs with a number ...
Chapter 19 Rotary Transformer Design
... There are two basic problems not found in the normal transformer: (1) the inherent gap in a rotary transformer is one problem, and (2) the required spacing between primary and secondary that leads to large leakage inductance is the other. These problems, along with a square wave drive, are what lead ...
... There are two basic problems not found in the normal transformer: (1) the inherent gap in a rotary transformer is one problem, and (2) the required spacing between primary and secondary that leads to large leakage inductance is the other. These problems, along with a square wave drive, are what lead ...
Chapter 16: Electromagnetic Induction
... Whenever a magnetic field linked with a conductor changes, an induced e.m.f is generated in the conductor. The Magnitude of the induced e.m.f is directly proportional to the rate of change of magnetic field linking the conductor. Arrange the first three fingers of the right hand mutually perpendicul ...
... Whenever a magnetic field linked with a conductor changes, an induced e.m.f is generated in the conductor. The Magnitude of the induced e.m.f is directly proportional to the rate of change of magnetic field linking the conductor. Arrange the first three fingers of the right hand mutually perpendicul ...
AF22192201
... NMOS transistor placed in parallel to the pull-up sleep transistor connects VDD to the pull-up network. When in sleep mode, this NMOS transistor is the only source of VDD to the pull-up network since the sleep transistor is off. Similarly, to maintain a value of „0‟ in sleep mode, given that the „0‟ ...
... NMOS transistor placed in parallel to the pull-up sleep transistor connects VDD to the pull-up network. When in sleep mode, this NMOS transistor is the only source of VDD to the pull-up network since the sleep transistor is off. Similarly, to maintain a value of „0‟ in sleep mode, given that the „0‟ ...