the Millennium User Manual
... The manual and the conformity certificate are an integral part of the equipment and should always accompany the product in the event of a transfer to a new location or to a new owner. The user is responsible for the integrity of these documents, for their consultation and during the whole life cycle ...
... The manual and the conformity certificate are an integral part of the equipment and should always accompany the product in the event of a transfer to a new location or to a new owner. The user is responsible for the integrity of these documents, for their consultation and during the whole life cycle ...
nfpa_70e-dmms-short - IDEAL INDUSTRIES, INC.
... – When there is a possibility of inducted or stored energy present ground the phase conductors • When it could be possible that a de-energized circuit come in contact with a energized circuit use grounding connection devices rated for the possible available fault. • Refer to 120.1 for an approved gr ...
... – When there is a possibility of inducted or stored energy present ground the phase conductors • When it could be possible that a de-energized circuit come in contact with a energized circuit use grounding connection devices rated for the possible available fault. • Refer to 120.1 for an approved gr ...
Computer-8d -96 Computer-8d
... cover opening actions or elements removal may allow accessing dangerous parts. Therefore, the instrument must not be used until this is completely installed. ...
... cover opening actions or elements removal may allow accessing dangerous parts. Therefore, the instrument must not be used until this is completely installed. ...
Accurate Fault Location in Transmission Networks Using Modeling
... denoted as “sparse data”. Under this situation, many proposed algorithms for estimating fault location based on DFR measurements may fail to produce accurate results. This project is aimed at developing accurate fault location algorithms for situations where only sparse field data is available. The ...
... denoted as “sparse data”. Under this situation, many proposed algorithms for estimating fault location based on DFR measurements may fail to produce accurate results. This project is aimed at developing accurate fault location algorithms for situations where only sparse field data is available. The ...
METL 2441 - HCC Learning Web
... • In cases of cathodic interference, if conditions are suitable, galvanic anodes can be used at discharge points on the foreign line to safely return interfering currents. • They can also be used to provide protection to structures located near many other underground metallic structures. ...
... • In cases of cathodic interference, if conditions are suitable, galvanic anodes can be used at discharge points on the foreign line to safely return interfering currents. • They can also be used to provide protection to structures located near many other underground metallic structures. ...
Tesla coil - 50Webs.com
... switch the charge in the capacitor through the primary coil. A secondary coil supporting a metallic toroid or top load is coupled with the primary. How a Tesla coil works As the capacitor charges from the high voltage power supply, the potential across the static spark gap electrodes increases until ...
... switch the charge in the capacitor through the primary coil. A secondary coil supporting a metallic toroid or top load is coupled with the primary. How a Tesla coil works As the capacitor charges from the high voltage power supply, the potential across the static spark gap electrodes increases until ...
MP6507 - Monolithic Power System
... For this control method, the motor current is regulated by an internal constant off-time PWM current control circuit as the following: • Initially, a diagonal pair of MOSFETs turns on so current can flow through the motor winding. • The current increases in the motor winding, which is sensed by an e ...
... For this control method, the motor current is regulated by an internal constant off-time PWM current control circuit as the following: • Initially, a diagonal pair of MOSFETs turns on so current can flow through the motor winding. • The current increases in the motor winding, which is sensed by an e ...
being protected
... node 304 the second trigger gate (G2) will be forward biased and drain these charges to ground through the second gate resistor 312. When positive electrostatic charges accumulate at the node 304, a positive potential will be built up until the ?rst trigger gate (G1) is in reverse breakdown. This br ...
... node 304 the second trigger gate (G2) will be forward biased and drain these charges to ground through the second gate resistor 312. When positive electrostatic charges accumulate at the node 304, a positive potential will be built up until the ?rst trigger gate (G1) is in reverse breakdown. This br ...
STP 3 & 4 8.2 Offsite Power Systems
... The 345 kV transmission system from STP 3 & 4 to the ERCOT grid is designed so that any two of the 345 kV transmission circuits from STP 3 & 4 may be taken out of service and the full-load generation of STP 3 & 4 can still be transmitted to their respective load centers. The loss of any double-circu ...
... The 345 kV transmission system from STP 3 & 4 to the ERCOT grid is designed so that any two of the 345 kV transmission circuits from STP 3 & 4 may be taken out of service and the full-load generation of STP 3 & 4 can still be transmitted to their respective load centers. The loss of any double-circu ...
MAX5946 Dual PCI Express, Hot-Plug Controller General Description
... auxiliary input supply rises above its UVLO threshold. Upon a turn-on command, the MAX5946 enhances the external and internal MOSFETs slowly with a constant gate current to limit the power-supply inrush current. The MAX5946 actively limits the current of all outputs at all times and shuts down if an ...
... auxiliary input supply rises above its UVLO threshold. Upon a turn-on command, the MAX5946 enhances the external and internal MOSFETs slowly with a constant gate current to limit the power-supply inrush current. The MAX5946 actively limits the current of all outputs at all times and shuts down if an ...
Developing an equipment SCCR standard for manufacturers of
... according to their component short-circuit current ratings. How do components used in industrial control panels relate to a short-circuit event? When a short-circuit event occurs, overcurrent protective devices, such as circuit breakers and fuses, will operate and open the circuit. It is not enough ...
... according to their component short-circuit current ratings. How do components used in industrial control panels relate to a short-circuit event? When a short-circuit event occurs, overcurrent protective devices, such as circuit breakers and fuses, will operate and open the circuit. It is not enough ...
Annex I - Loughborough University
... has been made safe to work on, the safety precautions applied to ensure continued safety and the work which is to be carried out. c. PERMIT-TO-TEST – A permit to test specifies the high voltage apparatus which has been made safe for testing to proceed and the conditions under which the testing is to ...
... has been made safe to work on, the safety precautions applied to ensure continued safety and the work which is to be carried out. c. PERMIT-TO-TEST – A permit to test specifies the high voltage apparatus which has been made safe for testing to proceed and the conditions under which the testing is to ...
8.0 ELECTRIC POWER
... The U.S. EPR FSAR includes the following COL Item in Section 8.2.1.1: A COL applicant that references the U.S. EPR design certification will provide site -specific information regarding the offsite transmission system and connections to the station switchyard. This COL Item is addressed as follows: ...
... The U.S. EPR FSAR includes the following COL Item in Section 8.2.1.1: A COL applicant that references the U.S. EPR design certification will provide site -specific information regarding the offsite transmission system and connections to the station switchyard. This COL Item is addressed as follows: ...
Electrical Safety Rules
... Issue of an Access Permit ........................................................................................... 36 ...
... Issue of an Access Permit ........................................................................................... 36 ...
AP2161/ AP2171 Description Pin Assignments
... In the third condition, the load has been gradually increased beyond the recommended operating current. The current is permitted to rise until the current-limit threshold (ITRIG) is reached or until the thermal limit of the device is exceeded. The AP2161/AP2171 is capable of delivering current up to ...
... In the third condition, the load has been gradually increased beyond the recommended operating current. The current is permitted to rise until the current-limit threshold (ITRIG) is reached or until the thermal limit of the device is exceeded. The AP2161/AP2171 is capable of delivering current up to ...
MC33811, Solenoid Monitor Integrated Circuit
... via the serial input (SI) pin, and status information is received by the MCU via the serial output (SO) pin. The falling edge of CS enables the SO output and transfers status information into the SO buffer. Rising edge of the CS initiates the following operation: 1. Disables the SO driver (high-impe ...
... via the serial input (SI) pin, and status information is received by the MCU via the serial output (SO) pin. The falling edge of CS enables the SO output and transfers status information into the SO buffer. Rising edge of the CS initiates the following operation: 1. Disables the SO driver (high-impe ...
Liebert Series 610 UPS Installation Manual - 100-225kVA, 60Hz, Three Phase Single-Module
... This equipment contains several circuits that are energized with high voltage. Only test equipment designed for troubleshooting should be used. This is particularly true for oscilloscopes. Always check with an AC and DC voltmeter to ensure safety before making contact or using tools. Even when the p ...
... This equipment contains several circuits that are energized with high voltage. Only test equipment designed for troubleshooting should be used. This is particularly true for oscilloscopes. Always check with an AC and DC voltmeter to ensure safety before making contact or using tools. Even when the p ...