• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
PD166013T1J  Data Sheet INTELLIGENT POWER DEVICE
PD166013T1J Data Sheet INTELLIGENT POWER DEVICE

... Page 10 of 26 ...
Corcom EMI/RFI Filter Product Overview
Corcom EMI/RFI Filter Product Overview

book here
book here

R&D Lab Safety for Physicists
R&D Lab Safety for Physicists

... tapped pole transformer feeds a breaker panel) ...
Uses for TPS cables
Uses for TPS cables

... with a copper screen surrounding the actives that is intended to be the neutral conductor Screened cable—Circular TPS cables with copper braided screens are commonly used for the connections between induction motors and variable frequency drives. The screen is connected to earth but is not necessari ...
K2CU-F10A-FGS Datasheet
K2CU-F10A-FGS Datasheet

... time, a voltage is imposed on the power circuit of the K2CU-F. The current flowing to the heater wires is detected by the detector sections through each Current Transformer (CT) incorporated by the K2CU-F. The current signals transmitted by the two CTs are sent to the current-voltage converters, smo ...
MAX1997/MAX1998 Quintuple/Triple-Output TFT LCD Power Supplies with Fault Protection and VCOM Buffer
MAX1997/MAX1998 Quintuple/Triple-Output TFT LCD Power Supplies with Fault Protection and VCOM Buffer

... regulator with two linear-regulator controllers, input protection switch control, and flexible sequence programming. The MAX1997 contains two additional linearregulator controllers and a VCOM buffer. The MAX1997/ MAX1998 can operate from input supplies of 2.7V to 5.5V and feature multiple levels of ...
Fieldbus Device Couplers Simplify Upgrade at
Fieldbus Device Couplers Simplify Upgrade at

... As the vital link between the process control system and fieldbus devices such as valves or temperature and pressure transmitters, device couplers can be likened to the master link of a chain. Just as a chain is only as strong as its weakest link, so must device couplers excel at their appointed tas ...
Lockout-Tagout Plan - Suffolk County Community College
Lockout-Tagout Plan - Suffolk County Community College

... equipment or machinery, the authorized employee shall test for an energy free state with an electrical testing device (meter). Working on Live Electrical Equipment College Employees will not work on live equipment. Qualified employees must check for electrical de-energization of electrical circuits ...
Understanding And Applying The Nfpa 70e Tables Palmer Hickman
Understanding And Applying The Nfpa 70e Tables Palmer Hickman

Atmel LED Drivers MSL4163/MSL4164
Atmel LED Drivers MSL4163/MSL4164

Advice regarding High Frequency electronic luminaires
Advice regarding High Frequency electronic luminaires

... insulated, must be segregated in separate screened and earthed channels/conduits and must not be positioned parallel to each other within the luminaire due to radiated electrical interference. The exception to this is to use a digital bus system, which is non corruptible, with 500 V insulation sleev ...
ABS Diagnostics - Innovative Products of America
ABS Diagnostics - Innovative Products of America

appendix d: suggestion form, qa-90
appendix d: suggestion form, qa-90

... the connection between the seventh and the eighth wires in the cable. The cable may still be called NULL-modem, but it will not work with the QA-90. Refer to the PROSoft QA-90 Users Manual for more information. ...
CM1231-02SO 2, 4 and 8-Channel Low-Capacitance ESD Protection Array
CM1231-02SO 2, 4 and 8-Channel Low-Capacitance ESD Protection Array

... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor doe ...
2731-AQA Physics P3.3 SoW Keeping things moving
2731-AQA Physics P3.3 SoW Keeping things moving

FPF2223-FPF2225 Integrated Load Switch with Adjustable High Precision Current Limit FP F2
FPF2223-FPF2225 Integrated Load Switch with Adjustable High Precision Current Limit FP F2

... ON pin is still active. The FPF2224 do not have this auto-restart feature so the switch will remain off until the ON pin is cycled. For the FPF2225, a current limit condition will immediately pull the fault signal pin low and the part will remain in the constantcurrent mode until the switch current ...
Figure 1.1 A telephone system.
Figure 1.1 A telephone system.

... EE 1270: Introduction to Electric Circuits Overview of Electrical Engineering  Communication Systems  Generate, transmit and distribute information: radio, ...
Arc detecting relay system
Arc detecting relay system

... The arcing time is thus reduced to the mechanical opening time of the circuit breaker, reducing personal injury as well as damage to the installation. The relay is completely solid state with complete isolation between input and output. Thus the relay can operate on one pilot voltage and the circuit ...
High speed digital design
High speed digital design

Distance Protection 7SA6
Distance Protection 7SA6

Issues to Consider when Substituting Large Power Transformers in
Issues to Consider when Substituting Large Power Transformers in

... of UT (rated voltages, rated MVA, impedance, and over-excitation) by portraying graphically their effect under various operation conditions. While this method is mainly dedicated to a new plant project, it may be also used in case of a substitute transformer. A typical graph (Fig. 2) shows the chang ...
Modeling and Simulation of Transient Fault Response at
Modeling and Simulation of Transient Fault Response at

Technical performance requirements for the connection of large
Technical performance requirements for the connection of large

Guidelines for the Design of Critical Communications Circuits_current
Guidelines for the Design of Critical Communications Circuits_current

... Unless the communications equipment is substation-hardened, it is to have its own DC power system, supplied by a separate battery. Large transients can be induced on the substation battery DC bus during a fault resulting from the operation of substation equipment (opening/closing switches or breaker ...
< 1 ... 40 41 42 43 44 45 46 47 48 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.