• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
NEC Articles
NEC Articles

... 820.133 Installation of Coaxial Cables and Equipment. (A) Separation from Other Conductors. (1) In Raceways, Routing Assemblies, Cable Trays, Boxes, and Enclosures. (C) Electric Light, Power, Class 1, Non-Power-Limited Fire Alarm, and Medium-Power NetworkPowered Broadband Communications Circuits. Co ...
Active Elements for Analog Signal Processing: Classification
Active Elements for Analog Signal Processing: Classification

... under the code EL2717 [28]. In [29], the variable gain is implemented via transforming current Iz into voltage by means of resistors, and via back transformation of voltage into current by means of electronically gm-controlled OTA. The most recent solution is characterized by digital control of the ...
Research of Driving Circuit in Coaxial Induction
Research of Driving Circuit in Coaxial Induction

... interconnect from breech to muzzle in one phase. It could not only enhance the utilization ratio of the energy, but also provide the current to the stages with gradually narrowed pulse width. But disadvantage of this special circuit is very clear. First, it is only applicable for the asynchronous in ...
970 IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS—II: ANALOG AND DIGITAL SIGNAL...
970 IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS—II: ANALOG AND DIGITAL SIGNAL...

... [16] J. G. Reich, C Curve Fitting and Modeling for Scientists and Engineers. New York: McGraw-Hill, 1992. ...
APARTARRAYOS PDV_PVR
APARTARRAYOS PDV_PVR

WP016: Lightning and surge protection for wind turbines
WP016: Lightning and surge protection for wind turbines

... to distribute lightning currents and to prevent that the wind turbine is destroyed. Moreover, the earth-termination system must protect persons and animals against electric shock. In case of a lightning strike, the earth-termination system must discharge high lightning currents to the ground and dis ...
SABS STANDARDS DIVISION Amendment No. 8
SABS STANDARDS DIVISION Amendment No. 8

Study of the current±voltage characteristics in MOS capacitors with
Study of the current±voltage characteristics in MOS capacitors with

... and can be applied as a non-stacked EEPROM or ¯ash memory [1±10]. The memory e€ect of the Siimplanted SiO2 is believed to be due to a trap-like behavior of excess Si atoms [2, 6]. Recently it was reported that the Si-implanted MOS capacitor emits visible electroluminescence and is useful as a light ...
Trade of Electrician Motor Control COURSE NOTES
Trade of Electrician Motor Control COURSE NOTES

Overcurrent Protection for Phase and Earth Faults
Overcurrent Protection for Phase and Earth Faults

UNIT 5 - CPO Science
UNIT 5 - CPO Science

... visible because it usually flows inside solid metal wires. Electric current can carry energy and do work just as a current of water can. For example, a waterwheel turns when a current of water exerts a force on it (Figure 13.1). A waterwheel can be connected to a machine such as a loom for making cl ...
Overvoltage Protection Devices SENTRON Answers for infrastructure and cities. Configu-
Overvoltage Protection Devices SENTRON Answers for infrastructure and cities. Configu-

NEW TRIACS: IS THE SNUBBER CIRCUIT NECESSARY?
NEW TRIACS: IS THE SNUBBER CIRCUIT NECESSARY?

... The aid circuit makes up a resonant circuit with the load. At turn off it limits the slope of reapplied voltage dV/dt but generates an overvoltage VM. Its choice results of a compromise in order to respect (dV/dt)c and repetitive peak off state voltage VDRM triac specification.There are two possibil ...
MC33812, Multifunctional Ignition and Injector Driver
MC33812, Multifunctional Ignition and Injector Driver

NEW TRIACS: IS THE SNUBBER CIRCUIT NECESSARY?
NEW TRIACS: IS THE SNUBBER CIRCUIT NECESSARY?

... The aid circuit makes up a resonant circuit with the load. At turn off it limits the slope of reapplied voltage dV/dt but generates an overvoltage VM. Its choice results of a compromise in order to respect (dV/dt)c and repetitive peak off state voltage VDRM triac specification.There are two possibil ...
PassPoint PTDCM Door Control Module
PassPoint PTDCM Door Control Module

... outputs of the PassPoint PTDPSU power supply only. (Do not enable AC or Low Battery monitoring without first wiring the power supply.) DCM Relay Outputs In addition to card reader inputs, each DCM has two Form C, voltage-supervised output relays. These relays are used to operate electromagnetic door ...
What is Lightning - Academica-e
What is Lightning - Academica-e

... Probability distributions of the electrical parameters that are used to describe a lightning stroke have been produced using direct measurements of actual stroke to tall towers. This statistical date on lightning current parameters is used in the lightning protection standards of the IEC 62305. The ...
Lighting Surge Protection Modules Design and Installation Guide
Lighting Surge Protection Modules Design and Installation Guide

... disturbances in AC power lines, temporary over-voltages (TOVs) are longer-duration (milliseconds to minutes long) abnormal high voltages affecting the SPD module. TOVs can lead to short-circuited SPD modules and thermal runaway, potentially resulting in a catastrophic fire or explosion of the SPD. S ...
Coordinated Circuit Protection for USB Applications
Coordinated Circuit Protection for USB Applications

... ESD Protection Requirements The result of an imbalance of electrons between two objects separated by a dielectric is static electricity. This type of electrostatic discharge, or ESD, is a well-known phenomenon that can cause various types of failures in electronic systems. System failures can be gen ...
Common Mode Noise Reduction for an LLC Resonant
Common Mode Noise Reduction for an LLC Resonant

Short-Circuit Generator Set for AICHI ELECTRIC CO., LTD.
Short-Circuit Generator Set for AICHI ELECTRIC CO., LTD.

Commercial PV Using the Enphase M
Commercial PV Using the Enphase M

... communication domain. The microinverter subpanel contains multiple 20A circuit breakers, each feeding one microinverter output branch circuit. Power Line Communication: Power line communication (PLC) technology enables signal transmission over the same AC lines used for on-site power distribution. E ...
Protective Relaying Philosophy and Design Guidelines
Protective Relaying Philosophy and Design Guidelines

... Two independent schemes are required for ground fault protection with independent current or voltage sources and independently protected DC control circuits. At least one of the schemes is required to be designed to provide protection for 100% of the stator winding. The relays must be properly coord ...
Troubleshooting with Insulation Resistance Test
Troubleshooting with Insulation Resistance Test

... 2. Inspect cables and wires for proper grounding, cable support, and termination. Terminate those sections that are not properly terminated. 3. If cables and wires are properly terminated, verify that neutrals and grounds are properly terminated for operation of protective devices. 4. Perform an ins ...
intelligent - Middle Atlantic
intelligent - Middle Atlantic

< 1 ... 42 43 44 45 46 47 48 49 50 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.