• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
INTRINSIC SAFETY
INTRINSIC SAFETY

... dust or mist, and is limited to contact sensing applications. Fiber-optic loops are also a safe means of control because they are powered by light. When the light reaches the instrument however, it will probably need to be converted to electricity. In these cases, the electrical safety methods discu ...
Transient Voltage Suppressors (TVS Diode) Applications
Transient Voltage Suppressors (TVS Diode) Applications

... Repeatable transients are frequently caused by the operation of motors, generators, or the switching of reactive circuit components. Random transients, on the other hand, are often caused by Lightning and Electrostatic Discharge (ESD). Lightning and ESD generally occur unpredictably, and may require ...
ph and pv oem instruction manual
ph and pv oem instruction manual

... Preventive Maintenance (Inspection and Cleaning) – Periodic system inspections, cleaning, and connection checks are recommended to ensure reliable system performance. There is no defined schedule for preventive maintenance, as conditions will vary from installation to installation. Corrective Mainte ...
AC and DC Power and Ground Wiring
AC and DC Power and Ground Wiring

2-Channel PicoGuard XP® ESD Clamp Protection Array CM1231-02SO
2-Channel PicoGuard XP® ESD Clamp Protection Array CM1231-02SO

... This limits the speed that the ESD pulse can discharge through the single stage protection element. In the PicoGuard XP® architecture, the inductance elements are in series to the conduction path leading to the protected device. The elements actually help to limit the current and voltage striking th ...
Power Supply Installation
Power Supply Installation

F-Pickup 2,5 kW, 560 V DC - Conductix
F-Pickup 2,5 kW, 560 V DC - Conductix

... This symbol can be found in several places of the operating instructions where special care has to be taken due to voltage presence which is a potential danger to the life of people. Please observe these instructions and be careful in those cases. Please carry out all health and safety regulations t ...
Wire Antennas For Limited Space
Wire Antennas For Limited Space

13. Electrical network design - engineering site
13. Electrical network design - engineering site

DRQ-12/50-L48 Series
DRQ-12/50-L48 Series

... Input to output, continuous Input to baseplate, continuous Output to baseplate, continuous ...
Simplified Method for Using the NFPA 70E Tables?
Simplified Method for Using the NFPA 70E Tables?

Measuring instrument of the potentiometer type
Measuring instrument of the potentiometer type

... ment with either contact 2i or contact 22. deenergize the relay 26. Shunted across the switches 35 and 36 is a vari ‘The embodiment of the invention disclosed in 20 able resistance 43 and a condenser 44 in series, Figure 6 differs from those previously described which upon opening of either switch 3 ...
TE News_11_10.qxd:GAN 09_05_final.qxd
TE News_11_10.qxd:GAN 09_05_final.qxd

caution - Liebert
caution - Liebert

... This equipment contains several circuits that are energized with high voltage. Only test equipment designed for troubleshooting should be used. This is particularly true for oscilloscopes. Always check with an AC and DC voltmeter to ensure safety before making contact or using tools. Even when the p ...
Aalborg Universitet kA/1.1 kV Non-Destructive Testing Equipment
Aalborg Universitet kA/1.1 kV Non-Destructive Testing Equipment

... output with fault-tolerant control. However, short-circuit failure is critical to converters, since the uncontrolled highlevel short-circuit current may destroy and even explode the failed IGBT and/or other components in the system [5]. At present, 10 μs is a typical duration stated for short-circui ...
Tektronix AM503 current probe system, user-manual
Tektronix AM503 current probe system, user-manual

... Tektronix, Inc., P.O. Box 1000, Wilsonville, OR 97070–1000 TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. ...
Electrical measurements
Electrical measurements

... Moreover, we have not said anything about the concentration of charge carriers, which depends on materials, temperature and composition. While these are the interesting parameters for us as chemists, physicists or materials scientists, this course is not so much about that. Instead it is about the m ...
Unit 14 TRANSFORMERS
Unit 14 TRANSFORMERS

Download
Download

... ENGINEERING & EEE, VSSUT, Burla and the proposed lay out Plan indicating the location of each unit for necessary Technical Evaluation. The scope of Supply as mentioned in the schedule of requirements if not sufficient for full function of the materials should be intimated in writing with the technic ...
PD166017T1F  Data Sheet INTELLIGENT POWER DEVICE
PD166017T1F Data Sheet INTELLIGENT POWER DEVICE

... When an inductive load is switched off, the power MOS portion goes into avalanche behavior. Maximum allowable energy in avalanche behavior is specified in "Absolute Maximum Ratings" as EAS1. The energy dissipation for an inductive load switch-off single pulse in device (EAS1) is estimated by the fol ...
ADG601 数据手册DataSheet下载
ADG601 数据手册DataSheet下载

... Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. N ...
FTS 430/830-4 - Flash Technology
FTS 430/830-4 - Flash Technology

... While every effort has been made to ensure that the information in this manual is complete, accurate and up-to-date, Flash Technology Corporation of America assumes no liability for damages resulting from any errors or omissions in this manual, or from the use of the information contained herein. Fl ...
Design and construction of a numerical over current relay
Design and construction of a numerical over current relay

... in the power system. These undesirable conditions are short circuit, current leakage, ground short, over current and over voltage. With the increasing loads, voltages and short-circuit duty in distribution system, over current protection has become more important role today. The ability of protectio ...
Over Voltage Protection
Over Voltage Protection

... Over Voltages produced by transients or the system. These include: ...
Radial Chapter - Massachusetts Distributed Generation Collaborative
Radial Chapter - Massachusetts Distributed Generation Collaborative

... Note 1. On a typical radial distribution system circuit (“feeder”) the annual peak load is measured at the substation circuit breaker, which corresponds to the supply point of the circuit. A circuit may also be supplied from a tap on a higher-voltage line, sometimes called a subtransmission line. On ...
< 1 ... 30 31 32 33 34 35 36 37 38 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report