• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Electrical Aspects of Electrical Generation from Tidal Currents
Electrical Aspects of Electrical Generation from Tidal Currents

... in that they will only generate power when asked to do so. In the case of non fossil fuels used for generation under the NFFO or AER tariffs there is an exception made in that the supply authority is obliged to accept all the electricity, which is generated in this manner. The increased cost is spre ...
CIRCUIT FUNCTION AND BENEFITS
CIRCUIT FUNCTION AND BENEFITS

... through to the DAC output. Avoid crossover of digital and analog signals. Traces on opposite sides of the board must run at right angles to each other. This reduces the effects of feedthrough on the board. A microstrip technique is recommended, but not always possible with a double-sided board. In t ...
Sleep Sound3
Sleep Sound3

... designing housing for the electrical equipment, incorporating the base unit and receivers, and testing. ...
Ground and Short Circuit
Ground and Short Circuit

... Grounding and Short Circuit Additional rules for switchgears with nominal voltages over 1 kV For works on transformers, both sides are to be grounded and short ciruit, even if the nominal voltage on the LV side is under 1 kV. This rule is also valid for three or multiple winding transformers. Besid ...
MGA-85-A Evaluation Circuit Board Application Note
MGA-85-A Evaluation Circuit Board Application Note

resistance.
resistance.

...  Impedance is also measured in ohms. ...
High Efficiency Power Amplifier Product Instructions
High Efficiency Power Amplifier Product Instructions

... Do not install the product within the environment of extreme temperature or dust and mechanical vibration. This equipment shall be well ventilated and protected against dust, moisture, direct sunshine and violent during the use. It shall be kept away from radiating objects or heat sources and well v ...
HART 1401 - Basic Electricity for HVAC
HART 1401 - Basic Electricity for HVAC

... Course Goals/Objectives: ...
Switchgear & Protection
Switchgear & Protection

... VTs usually have range of voltage from 80% to 120 % and range of burden from 25 % to 100 %. In protection when voltage suppressed, accuracy measurement may be important during fault condition. ...
Lab 1 - UniMAP Portal
Lab 1 - UniMAP Portal

electricity and electronics
electricity and electronics

... The movement of electrons in a wire causes collisions and the increase of temperature of the wire. The heat produced by an electric current is called JOULE EFFECT. An example of application of this effect are RADIATORS and ...
Generator Stator Protection, under/over voltage, under /over
Generator Stator Protection, under/over voltage, under /over

Arc-EnErgy - InterNational Electrical Testing Association
Arc-EnErgy - InterNational Electrical Testing Association

A Constant-current Source - BYU Physics and Astronomy
A Constant-current Source - BYU Physics and Astronomy

Elec467 Power Machines & Transformers
Elec467 Power Machines & Transformers

... The Thermal overload relay operates somewhat like a thermocouple but uses different coefficients of expansion properties of two dissimilar metal to pull contacts apart when there is too much current causing the heater element to overheat. . ...
Series & Parallel Circuits PowerPoint
Series & Parallel Circuits PowerPoint

... If a portion of the series component goes down nothing that follows that portion will work as the circuit has been broken, however if the parallel components still have energy ...
CA 6292 - Chauvin Arnoux
CA 6292 - Chauvin Arnoux

... This means the C.A 6292 offers excellent measurement accuracy for low resistance values, thanks to its 0.1 μΩ resolution and its accuracy of approximately 1% for measurement. The test current can be adjusted up to 200 A, as required. The C.A 6292 can also record up to 8,000 measurement results. ...
File
File

Basic Electronics I
Basic Electronics I

...  Impedance is also measured in ohms. ...
Teachware developed for students of UWB power engineering study
Teachware developed for students of UWB power engineering study

... The developed software for the short-circuit analysis is called TeNeCo (according to the names of its authors). The computer program is based on the principle of superposition and the method of symmetrical components [1], [3]. There are several approximations that have been used to simplify the faul ...
dual regulated power supply
dual regulated power supply

275DAY4CHAPTER3OUTLETS Lecture Notes Page
275DAY4CHAPTER3OUTLETS Lecture Notes Page

... Branch Circuit, Individual. A branch circuit that supplies only one utilization equipment. Branch Circuit, Appliance. A branch circuit that supplies energy to one or more outlets to which appliances are to be connected Branch Circuit, General-Purpose. A branch circuit that supplies two or more recep ...
Amp Rating (Current Rating)
Amp Rating (Current Rating)

... A protective device must be able to withstand the destructive energy of shortcircuit currents. If a fault current exceeds a level beyond the capability of the protective device, the device may actually rupture, causing additional damage. Thus, it is important when applying a fuse or circuit breaker ...
Electrical Installations Level 2 - Pearson Schools and FE Colleges
Electrical Installations Level 2 - Pearson Schools and FE Colleges

... Circuits supplied at voltages below 50 V may be required to have circuit protection for functional reasons. Circuits supplied at 50 V and above are required to have circuit protection that complies with the requirements of BS 7671. For example, low voltage circuits (above 50 volts, but not exceeding ...
Low Voltage Power Panel
Low Voltage Power Panel

... EntellEon, the new low voltage power panel brought to you by GE’s Energy Connections business, offers innovative features and exceptional versatility to support the performance of the next industrial era. ...
< 1 ... 275 276 277 278 279 280 281 282 283 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report