• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Pendahuluan Mesin Elektrik / Mesin Elektrik Secara Am
Pendahuluan Mesin Elektrik / Mesin Elektrik Secara Am

... energy is conserved from one form to another in motors, generators and transformers. A magnetic field is a condition resulting from electric charges in motion. For convenience in visualization and analysis, magnetic fields are represented on diagrams by close loops. Theses loops, called magnetic flu ...
EE32828833
EE32828833

... controller sharing many similar concept with that of STATCOM used at transmission level. A ...
Lecture 12: Electromagnetic Induction
Lecture 12: Electromagnetic Induction

Active filters
Active filters

Section 4
Section 4

Session Eight:  Short Circuit Requirements and Selection of
Session Eight: Short Circuit Requirements and Selection of

Terms and Abbreviations
Terms and Abbreviations

... Analog signal - A signal that attains an infinite number of different amplitude levels. AO - Analog Output Apparent Power - The power value obtained by multiplying the current by the voltage (P = I X E). 9. Axial dimension - This term is used for the measurement of the coupler distance during the ge ...
AI13 Modular Trainer for Electrotecnics Technical Teaching Equipment
AI13 Modular Trainer for Electrotecnics Technical Teaching Equipment

... MUAD is the perfect link between the application/module and the PC. MUAD is a continuous data acquisition system with virtual instrumentation, that measures, analyzes and represents the parameters involved in the process. MUAD allows voltage and current acquisition and measurement, data processing, ...
IPN = 100 .. 400 A AC/DC Current Transducer DHR-C10
IPN = 100 .. 400 A AC/DC Current Transducer DHR-C10

Applications
Applications

Lightning and surge protection for maximum safety
Lightning and surge protection for maximum safety

... • Protection devices for multi-core systems • Installed widths of 8 to 17.5 mm • Extremely large frequency bandwidths of up to 100 MHz ...
Catalogue PDF (1,705 KB)
Catalogue PDF (1,705 KB)

... Dry air insulation In response to the increasing concern for the environment, ...
section 260573 - overcurrent protective device coordination study
section 260573 - overcurrent protective device coordination study

Circuit Note CN-0058
Circuit Note CN-0058

V TH - No-IP
V TH - No-IP

... Thevenin’s Theorem Case 2: If the network has dependent sources, turn off all independent sources. Do not turn off dependent sources because they are controlled by circuit variables.  Apply a voltage source vo and determine the resulting current, or apply a current source io and determine the resu ...
TR41.9.1-08-08-005_Draft proposed revisions to Defintions
TR41.9.1-08-08-005_Draft proposed revisions to Defintions

Ενότητα 9: Electric Meters
Ενότητα 9: Electric Meters

... III.1. Link the sentences below, making the second sentence in each pair a relative clause. Use relative pronouns, such as, who, which, where, whose. 1. Manganin is a metal. This metal has a comparatively high resistance. 2. Armoured cables are used in places. There is a risk of mechanical damage in ...
Assessment Task 1
Assessment Task 1

... Anti-static mats or straps ...
testing grounding systems - Wyoming Department of Workforce
testing grounding systems - Wyoming Department of Workforce

testing grounding systems
testing grounding systems

... grounding systems can prevent electrical accidents This all sounds so good that we made it the policy regarding 12028. ...
protecting rechargeable li-ion and li-polymer batteries
protecting rechargeable li-ion and li-polymer batteries

... A PolySwitch PPTC device placed in series with the battery helps provide a second level of protection in the event of a control circuit malfunctioning (Figure 1). Although the semiconductor circuitry is considered reliable, there are conditions under which failure of the primary protection may occur ...
A p p e n d i x   –... S a f e t y   P r... E l e c t r o n i c...
A p p e n d i x –... S a f e t y P r... E l e c t r o n i c...

... 1.1 Why is safety important? Attention and adherence to safety considerations is even more important in a power electronics laboratory than it’s required in any other undergraduate electrical engineering laboratories. Power electronic circuits can involve voltages of several hundred volts and curren ...
PolySwitch Resettable Devices Fundamentals
PolySwitch Resettable Devices Fundamentals

AN532 : Common Questions Concerning CMOS Analog Switches
AN532 : Common Questions Concerning CMOS Analog Switches

QA(13) - Series Miniature Circuit Breakers - CBI
QA(13) - Series Miniature Circuit Breakers - CBI

< 1 ... 184 185 186 187 188 189 190 191 192 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report