• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
A3918 - Allegro MicroSystems
A3918 - Allegro MicroSystems

... Brake Mode When driving DC motors, the A3918 goes into brake mode (turns on both sink drivers) when both of its inputs are high (IN1 and IN2). There is no protection during braking, so care must be taken to ensure that the peak current during braking does not exceed the absolute maximum current. Int ...
Fault Management Circuit
Fault Management Circuit

... the PRM to start up again, which restarts the VTM. If the fault condition still exists, the VTM shuts itself down again, bringing TM low and starting the process all over. If the fault condition has been cleared, the power supply runs normally. As long as the fault condition persists, the voltage on ...
guidelines for handling water-damaged electrical equipment
guidelines for handling water-damaged electrical equipment

Basic Connection for three phase transformer File
Basic Connection for three phase transformer File

Penang Branch
Penang Branch

Interphase Power Controllers - IEEE Canadian Review / La revue
Interphase Power Controllers - IEEE Canadian Review / La revue

... ne of the main reasons for developing the Interphase Power Controller (IPC) technology was to create new power flow controllers that would overcome the limitations on system operation caused by high short-circuit levels. In fact, excessive short-circuit levels constitute a widespread problem that ha ...
Lab 3
Lab 3

Testing Resistance Welding Transformers
Testing Resistance Welding Transformers

B.E 3/4 - II Semester
B.E 3/4 - II Semester

... relays, Protection of generator and transformer using percentage differential relays, Split phase, Inter turn protection, Overheating, Loss of excitation, Protection of generators, Protection of transformers against magnetizing inrush, Buchholz relay, Protection of earthing transformers, Generator t ...
Constructing an High Power, Low Cost LED - Microscopy-UK
Constructing an High Power, Low Cost LED - Microscopy-UK

On the selection and installation of surge protection devices in a TT
On the selection and installation of surge protection devices in a TT

Category 2 Parallel Operating Agreement
Category 2 Parallel Operating Agreement

Source Impedance - Controlled Power Company
Source Impedance - Controlled Power Company

Protective Relay Application Guide
Protective Relay Application Guide

... allows the operating time of upstream relays to be reduced thereby reducing the cable short-circuit withstand requirements. The grading interval may be reduced if required, for times less than about 1 sec, to 250 ms, using relays with high-stability timer circuits (which is the case with ITG 7000 or ...
Type 5411, 5413
Type 5411, 5413

... ▶▶ Correct transport, correct storage and installation as well as careful use and maintenance are essential for reliable and problem-free operation. ▶▶ Devices without a separate Ex type label may not be used in a potentially explosive area. ▶▶ Use the device only as intended. ...
INV375
INV375

... for mounting the INV375SILED securely to the wall. There is an additional round hole for a #10 screw in the cabinet. Code requires that an additional screw be used through this hole to prevent the unit from being inadvertently lifted up off the keyhole slots. Do not drill any holes in this unit. If ...
5-Motors
5-Motors

... when electric power companies began considering the switch to alternating current. Alternating current was perfect for the distribution of electric power over long distances, and it worked well with the Edison electric lamp, but no practical AC motor existed until the works of Galileo Ferraris in It ...
PS21A79 Dual-In-Line Package Intelligent Power Module>  MITSUBISHI SEMICONDUCTOR <
PS21A79 Dual-In-Line Package Intelligent Power Module> MITSUBISHI SEMICONDUCTOR <

... 7 :For sense resistor, the variation within 1%(including temperature characteristics), low inductance type is recommended. And the over 1/8W is recommended, but it is necessary to evaluate in your real system finally. 8 :To prevent erroneous operation, the wiring of A, B, C should be as short as pos ...
PowerPoint Lecture
PowerPoint Lecture

Knob and tube wiring in residential installations
Knob and tube wiring in residential installations

... GFCI receptacle or a GFCI dead front mounted in an outlet box next to the panel). Where this option is used, no bonding conductor is permitted between outlets unless that bond conductor is in turn connected to ground. GFCI protection of the receptacles does not provide a ground reference to the U-gr ...
switch - Steel Connect
switch - Steel Connect

... Standards • IS 13947 ...
CA‐NLH‐019  BDE to Western Avalon Line  Page 1 of 2 Q. 
CA‐NLH‐019  BDE to Western Avalon Line  Page 1 of 2 Q. 

... of having multiple transformers connected to the same high voltage bus and the  ...
No Harmony in Harmonics
No Harmony in Harmonics

Loose or corroded electrical connections
Loose or corroded electrical connections

... so applicable to the monitoring of electrical systems is that new electrical components begin to deteriorate as soon as they are installed. Whatever the loading on a circuit, vibration, fatigue and age cause the loosening of electrical connections, while environmental conditions can hasten their cor ...
Ground Loop Noise Opto
Ground Loop Noise Opto

< 1 ... 187 188 189 190 191 192 193 194 195 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report