• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Medium Voltage Switchgear
Medium Voltage Switchgear

... The iCB series comprises embedded pole type vacuum circuit breakers for medium voltage and indoor use. They are suitable for three phase AC operations for 12kV, 17.5kV and 24kV are used for the protection of the electrical equipment in various industries, mining, and especially for medium voltage di ...
Space: a Toolbox for the Simulation of Analog
Space: a Toolbox for the Simulation of Analog

... Simulink, could handle the simulation of systems and numerical circuits, but not of analog circuits. In this paper, we present a Matlab toolbox called Space that allows, under a user-friendly environment, the simulation of linear and nonlinear analog electronic circuits. The circuit is graphically s ...
Supplemental Correction Sheet for Solar Photovoltaic
Supplemental Correction Sheet for Solar Photovoltaic

... 4. Circuit conductors shall be sized to carry not less than the larger of the following: (LAEC 690.8(B)(2)) (a) 125% of the maximum currents calculated in 690.8(A) without any additional correction factors for conditions of use. (b) The maximum currents calculated in 690.8(A) after conditions of use ...
Electric Generators and Motors
Electric Generators and Motors

... and will produce a counter torque. This means the external applied torque must increase to keep the generator turning. ...
Annex to the Decision of the Council of the Eurasian Economic
Annex to the Decision of the Council of the Eurasian Economic

... activities, including transfer free of charge, placing on the market, leasing, hiring or rental, as well as use by consumers (users), being customers in the sphere of services and trading; compounding parts (components and constituent element) of low-voltage equipment, supplied by the manufacturer o ...
1. Introduction
1. Introduction

... be the same as on substation 138kV bus j, except for possible zero-sequence component blocking and positive/negative-phase shifts. The significance of the above paragraph is that for transmission faults, one monitor at either the substation 138kV bus or at the substation 12.47kV bus is adequate to p ...
STK534U3xx series  Application Note 1.  Product synopsis
STK534U3xx series Application Note 1. Product synopsis

AC Current Transducer AP-B420L I = 10 400 A I = 10 .. 400 A
AC Current Transducer AP-B420L I = 10 400 A I = 10 .. 400 A

... The transducer shall be used in electric/electronic equipment with respect to applicable standards and safety requirements and in accordance with all the related systems and components manufacturer’ operating instructions. Caution, Risk of electrical shock When operating the transducer, certain part ...
CURRENT TRANSFORMERS (CT) OPERATED METER CHANGES
CURRENT TRANSFORMERS (CT) OPERATED METER CHANGES

Multiple parameter Monitor and Control in Wind Mills
Multiple parameter Monitor and Control in Wind Mills

Delta Versus Wye Connected Capacitor Banks
Delta Versus Wye Connected Capacitor Banks

By Pete Luban One of the most-difficult problems to diagnose on a
By Pete Luban One of the most-difficult problems to diagnose on a

CP-250-60-208/240
CP-250-60-208/240

Advanced PV System Design and Installation
Advanced PV System Design and Installation

Tue., Mar. 22 notes - UA Atmospheric Sciences
Tue., Mar. 22 notes - UA Atmospheric Sciences

... The resistive element has a cylindrical shape and the measuring circuit is inside the cylinder where the magnetic field is zero (B fields from currents flowing in the right and left hand sides of the cylinder point in opposite directions and cancel). The measuring instrumentation is placed in a met ...
sitop pse200u
sitop pse200u

INSTALLATION & OPERATING MANUAL SCIMITAR SERIES 1RU RACK-MOUNT INVERTERS WWW.UNIPOWERCO.COM
INSTALLATION & OPERATING MANUAL SCIMITAR SERIES 1RU RACK-MOUNT INVERTERS WWW.UNIPOWERCO.COM

... 2.3.15 Please confirm that the AC input breaker is set to the OFF position before connecting/disconnecting the AC power. Do not touch the AC INPUT terminals other than with properly insulated tools so as to avoid electric shock. Ensure that the protective cover has been correctly fitted after inst ...
Analog and Digital Meters
Analog and Digital Meters

... performance or improper operation. Lack of voltage at a given point may indicate an open circuit or ground. On the other hand, low voltage or high voltage drop, may indicate a high resistance problem like a poor connection. Voltmeters must be connected in parallel with the device or circuit so that ...
Avoiding Electrical Shocks
Avoiding Electrical Shocks

... because of a mistake in installation, it turned out that the white wire was the "hot" wire - not the black one. The black wire was neutral. He began to strip the white wire using a wire stripper in his right hand. Electricity passed from the "hot" white wire to the stripper, then into his hand and t ...
modified coupled-inductor single-stage boost inverter
modified coupled-inductor single-stage boost inverter

... technique for the modified coupled-inductor single-stage boost inverter (CLSSBI) based grid-connected photovoltaic (PV) system. a)High efficiency single phase transformerless inverters by S.V.Araujo and P.Zacharias: This paper talks about the H-Bridge with a new AC bypass circuit consisting in diode ...
260553 Elec Identification
260553 Elec Identification

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... results have determined that the Fast Fourier Transform method provides good steady state and transient responses for active filters in unbalanced systems. Keywords: Current Compensation, Fast Fourier Transform, Harmonic and Reactive power compensation, Instantaneous Active and Reactive Power, Harmo ...
GP1S093HCZ0F Gap : 2mm Slit : 0.3mm Phototransistor Output
GP1S093HCZ0F Gap : 2mm Slit : 0.3mm Phototransistor Output

... and is copyrighted, with all rights reserved. Under the copyright laws, no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, in whole or in part, without the express written permission of SHARP. Express written permissio ...
Module 2 Unit 6, 7, 8
Module 2 Unit 6, 7, 8

... 27. What is the maximum allowable ampacity for a No.12 TW copper conductor in a cable according to the CEC? 25 A 28. What is the maximum allowable ampacity for a No.10 TW copper conductor in a cable according to the CEC? 30 A 29. What is the maximum allowable ampacity for a No.000 TW copper conducto ...
Loop Sectionalization Automation Scheme
Loop Sectionalization Automation Scheme

< 1 ... 190 191 192 193 194 195 196 197 198 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report