• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
7a- Curr Meas Apps
7a- Curr Meas Apps

HIS – Highly Integrated Switchgear up to 550 kV, 63 kA
HIS – Highly Integrated Switchgear up to 550 kV, 63 kA

LINEAR VARIABLE DIFFERENTIAL TRANSFORMER
LINEAR VARIABLE DIFFERENTIAL TRANSFORMER

Device Functions Numbers
Device Functions Numbers

... to describe the purpose of certain switchgear. A device function number, with suffix letters and a prefix where appropriate, identifies what the device is expected to accomplish. Figure 1 is a one-line diagram showing a 3-phase transformer arranged with an ac circuit breaker on the incoming power li ...
Cooper Bussmann introduces SurgePOD™ Heavy Duty and Pro Type 1 SPDs 2/7/13 Cooper Bussmann expands its line of surge protective devices (SPDs) to include new Type 1 UL 1449 3rd Edition Listed SurgePOD™ Heavy Duty and Pro models. Read more
Cooper Bussmann introduces SurgePOD™ Heavy Duty and Pro Type 1 SPDs 2/7/13 Cooper Bussmann expands its line of surge protective devices (SPDs) to include new Type 1 UL 1449 3rd Edition Listed SurgePOD™ Heavy Duty and Pro models. Read more

... NEMA 4X Style SPDs provide loadside and lineside protection for any application ST. LOUIS, MO, February 1, 2013 – Cooper Bussmann, the industry leader in critical circuit protection, power management and electrical safety, has expanded its line of surge protective devices (SPDs) to include new Surge ...
Rajasthan Technical University, Kota  COURSE - FILE
Rajasthan Technical University, Kota COURSE - FILE

... 1. A transmission line of inductance 0.1 H and resistance 5 short circuited at t = 0, at the far end of a transmission line and is supplied by an ac t+150πsource of voltage v = 100 sin (100 ). Write the expression for the short circuit current, i(t). Find the approximate value of the first current m ...
HX-CB loadbreak fuse cutout COOPER POWER SERIES Fusing Equipment
HX-CB loadbreak fuse cutout COOPER POWER SERIES Fusing Equipment

ECEN 3711 -- BJTs, the Curve Tracer, and a DTL Circuit -
ECEN 3711 -- BJTs, the Curve Tracer, and a DTL Circuit -

... *Notes: Add a 0.1μF capacitor between the 3.5 and 0 V lines near their source, but on your SK board. This is called a decoupling capacitor and will minimize transient signals in the power-supply lines. Take care how you wire your experimental circuit. Be sure that only power (0 and 3.5 V feeds) are ...
CONTENTS
CONTENTS

... made, provided that the requirements of NEC Section 250-51, are met. Such permitted alterations are: 1. Discontinue one or more, but not all, of the grounding connections; 2. Change the locations of the grounding connections; 3. Interrupt the continuity of the conductor or conductive path interconne ...
EMC filters 2-line filters SIFI-F for normal insertion loss
EMC filters 2-line filters SIFI-F for normal insertion loss

Loop Selective Direction Measurement for Distance Protection
Loop Selective Direction Measurement for Distance Protection

... Loop Selective Direction Measurement for Distance Protection Gustav Steynberg* and Gerhard Koch* Abstract - Distance relays achieve selective tripping by measurement of all short circuit fault conditions inside set reaches. The direction of the fault, forward or reverse is commonly determined with a ...
Dual-Feed Rear Output Circuit Breaker Panel
Dual-Feed Rear Output Circuit Breaker Panel

Introduction to Short Circuit Current Calculations
Introduction to Short Circuit Current Calculations

KD2004-CG10A
KD2004-CG10A

... 2) The use of the newly developed highly-durable conductive protective film has improved countermeasures against static electricity. 3) The VH and GND sections of the power circuitry have been strengthened so that heavier current can be applied. 4) Ultra small connectors, designed to conform with FF ...
Resonance In both series and parallel RLC circuits, resonance
Resonance In both series and parallel RLC circuits, resonance

... At resonance, since the capacitor and inductor currents are 180° out of phase, the net circuit current is zero. This means that theoretically no current is supplied to the circuit at resonance. Also, since Z = V/I, the impedance seen by the source is theoretically infinite. Practical tank circuit In ...
AND9441 - Current Limits in Electronic Fuses using Direct
AND9441 - Current Limits in Electronic Fuses using Direct

... power MOSFET known as a SENSEFET to control current in the load. All power MOSFETs are made up of thousands of parallel FETs or cells. In a SENSEFET a small percent of the FET cells have their sources separated from the sources of the remaining FET cells. The ratio of cells in the main and small sec ...
Review: To Investigate Impacts of Various Factors on the
Review: To Investigate Impacts of Various Factors on the

ac circuits
ac circuits

... • The principle of magnetic flux is exploited in an important electrical safety circuit • As long as the input and output currents are equal and opposite, there is zero flux in through the secondary. • If current flows through an alternate path to ground (e.g. through your body!!) the imbalance prod ...
ELM 200 Electric Circuits I
ELM 200 Electric Circuits I

HV3613741380
HV3613741380

... inverters are represented by vs, vL, vinj, and Vdc, respectively. The current on the source side, current drawn by the loads, neutral current on the source side, load neutral current, and current injected by the shunt APF are represented by is, il, isn, iln, and ish, ...
N - PembyPhysics
N - PembyPhysics

Circuits Unit 4(F) Year-pg1
Circuits Unit 4(F) Year-pg1

... • construct a circuit in which a switch turns a specific device on or off • explain how their switch works ...
B61089QDR, Dual port negative voltage tracking SLIC protector
B61089QDR, Dual port negative voltage tracking SLIC protector

... for two SLIC ports (T1/R1 & T2/R2) by shunting positive and negative surges to the ground reference. The negative surges are diverted to ground through the SCRs which are connected between the TIP/RING conductors and the ground reference. These SCRs have a transistor buffered gate that provides a lo ...


... (1) If control GND is connected with power GND by common broad pattern, it may cause malfunction by power GND fluctuation. It is recommended to connect control GND and power GND at only a point N1 (near the terminal of shunt resistor). (2) It is recommended to insert a Zener diode (24V/1W) between e ...
High Speed Fuses
High Speed Fuses

... equally across the PN junction. They have short-circuit energy withstand levels that are lower than conventional branch circuit fuse let-throughs, however, Type 2 protection can be achieved with properly selected high-speed fuses. Equipment that use insulated gate bipolar transistors (IGBT) high fre ...
< 1 ... 182 183 184 185 186 187 188 189 190 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report