• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Ripple: Refers to a low or medium frequency repeating oscillation on
Ripple: Refers to a low or medium frequency repeating oscillation on

... 5. Losses in a real switch switching an inductive circuit In an inductive circuit the circuit inductance will attempt to keep current flowing while the switch is opening. Inductive circuits must have some form of alternative path (usually a freewheel diode) to allow the inductor current to continue ...
CHAPTER 8 Transmission of power
CHAPTER 8 Transmission of power

... Development of the transformer meant that the AC voltage from the generator could be connected to a step-up transformer to increase the voltage and decrease the current, and so reduce energy loss in the transmission lines. However, at the other end of the transmission line, the high voltage would be ...
An equivalent circuit formulation for three-phase power
An equivalent circuit formulation for three-phase power

... test cases. The 4-bus Wye-Delta center-tapped case is considered as an extremely challenging case in the literature [7] because the transformer connection, also known as the “4wire delta” bank, is nontrivial to handle. Grounding the center tap shifts the secondary voltage reference to an unusual loc ...
AC Power Distribution 6-9-10
AC Power Distribution 6-9-10

... • The AC line to the load usually connected to an AC outlet is passed through a magnetic core. • If there is no fault, the current in the hot and neutral leads are the same so no magnetic field is produced in the magnetic core of a transformer. • If a high resistance path is created between the hot ...
Parallel operation of step transformers
Parallel operation of step transformers

... rule, to which a certain arbitrariness adheres. A safer and more parallel operation of transformers is guaranteed only if their performance, i.e. whose rated outputs can be exploited fully and without overloading an individual transformer. There are two conditions to be met for this: ...
Grid and DG connected mode
Grid and DG connected mode

... The steady state models developed, simulate the operation of synchronous generator and induction generator in the stand-alone and grid-connected ...
i-class Induction Heating
i-class Induction Heating

... And a 9-pin.-Sub-D-Interface to load up new Firmware. Optional an additional Interface (also after installation) can be installed. These interface-cards are available as Profibus, Interbus-S, DeviceNet, RS 232/485 and others. ...
PUB‐NLH‐547  Island Interconnected System Supply Issues and Power Outages  Page 1 of 8   
PUB‐NLH‐547  Island Interconnected System Supply Issues and Power Outages  Page 1 of 8   

Implementation of grid-connected photovoltaic system with power
Implementation of grid-connected photovoltaic system with power

three phase transformers three phase system basics
three phase transformers three phase system basics

... 1. System voltages are more stable in relation to unbalanced load 2. If one t/f is failed it may be used for low power level ie V-V connection 3. No distortion of flux ie 3rd harmonic current not flowing to the line wire ...
Measurement of Power in 3-Phase Circuit
Measurement of Power in 3-Phase Circuit

MDS-065APS24 B Datasheet
MDS-065APS24 B Datasheet

ECE112 - Lab 8
ECE112 - Lab 8

... The swizzle circuit It is possible to use some diodes oriented such that so that it makes no difference which way batteries are installed. In this experiment, we will use four diodes to allow a battery to power the LED circuit regardless of how the battery is connected by using the ”one-way” behavi ...
Simple Electrical Circuit
Simple Electrical Circuit

KE2417381744
KE2417381744

STI13005-H
STI13005-H

... Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notic ...
Advantages of Switching DC Regulators
Advantages of Switching DC Regulators

...  A regulator is often needed to take this unstable voltage source and convert it to a stable voltage  This has been achieved for many years using linear technology, a inexpensive, though highly inefficient method to convert and regulate voltage  Using switching technology, CUI’s V78 series is abl ...
DBPPCTF protection supplement insert 62211
DBPPCTF protection supplement insert 62211

... 345 kV to 100 kV Transformer Applications The transformer protection should be divided into two systems an Overall Differential protection scheme and a second system providing providing protection for other needs such as Internal Differential, Highside and Lowside Lead Differential, backup overcurre ...
Single phase earth faults_solutions using reclosers to meet the
Single phase earth faults_solutions using reclosers to meet the

... interrupter with an optimised magnetic actuator. The combination of these two components into the single solution of a “recloser” allows new capabilities which can be used to resolve a large number of problems the utilities are facing in their electrical networks today. As an example, one of the man ...
Application of SVCs by CenterPoint Energy to Address Voltage
Application of SVCs by CenterPoint Energy to Address Voltage

KB ELECTRONICS, INC. 12095 NW 39th Street, Coral Springs
KB ELECTRONICS, INC. 12095 NW 39th Street, Coral Springs

4 Basler Plug-n-Play Relay add Arc Flash Detection Innovative NCT
4 Basler Plug-n-Play Relay add Arc Flash Detection Innovative NCT

... test device and the CMC to allow testing of all functionality that the manufacturer provided in their control cable. Test Cables for devices from Cooper, G&W, SEL and S&C are available along with sample test plan(s) and instructions. ...
RPI-246
RPI-246

... otherwise dispose of the same, no express or implied right or license to practice or commercially exploit any intellectual property rights or other proprietary rights owned or controlled by ROHM CO., LTD. is granted to any such buyer. Products listed in this document are no antiradiation design. ...
Page 107
Page 107

The Potentiostat and the Voltage Clamp
The Potentiostat and the Voltage Clamp

< 1 ... 924 925 926 927 928 929 930 931 932 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.