Document
... but these are suitable for other applications such as medical equipment, transportation, HVAC, motion control, and many industrial tools [2]–[4]. A BLDC motor has three phase windings on the stator and permanent magnets on the rotor [5], [6]. The BLDC motor is also known as an electronically commuta ...
... but these are suitable for other applications such as medical equipment, transportation, HVAC, motion control, and many industrial tools [2]–[4]. A BLDC motor has three phase windings on the stator and permanent magnets on the rotor [5], [6]. The BLDC motor is also known as an electronically commuta ...
Series and Parallel Circuit Problems
... 1. Three resistors are connected in series to a 10 V battery. The first resistor is a 16 Ω resistor, the second is a 36 Ω resistor and the third is a 28 Ω resistor. a) Draw and label the circuit using the correct schematic symbols. b) Find the total (or equivalent) resistance of the circuit (RT). c) ...
... 1. Three resistors are connected in series to a 10 V battery. The first resistor is a 16 Ω resistor, the second is a 36 Ω resistor and the third is a 28 Ω resistor. a) Draw and label the circuit using the correct schematic symbols. b) Find the total (or equivalent) resistance of the circuit (RT). c) ...
Diesel Generator Set Model DGHD 60 Hz
... Separately Excited Permanent Magnet Generator (PMG) System - This option uses an integral PMG to supply power to the voltage regulator. A PMG system generally has better motor-starting performance, lower voltage dip upon load application, and better immunity from problems with harmonics in the main ...
... Separately Excited Permanent Magnet Generator (PMG) System - This option uses an integral PMG to supply power to the voltage regulator. A PMG system generally has better motor-starting performance, lower voltage dip upon load application, and better immunity from problems with harmonics in the main ...
AT-250 Voltage Variable Absorptive Attenuator 12 dB, DC - 2.0 GHz
... Low Intermodulation Products Low DC Power Consumption: 50 μW Single Voltage Control: 0 to -4 Volts Nanosecond Switching Speed Temperature Range: -40°C to +85°C SOIC-8 Plastic Package Tape and Reel Packaging Available ...
... Low Intermodulation Products Low DC Power Consumption: 50 μW Single Voltage Control: 0 to -4 Volts Nanosecond Switching Speed Temperature Range: -40°C to +85°C SOIC-8 Plastic Package Tape and Reel Packaging Available ...
higher tier revision questions
... 12) What happens to the resistance of a LDR, when the light intensity falling on the component increases? 1 mark Power, Energy, Charge 13) Calculate the power of a hair drier which, when connected to a 210V supply, has a current of 8A flowing through it. 2 marks 14) When a 1.5kW fire is connected to ...
... 12) What happens to the resistance of a LDR, when the light intensity falling on the component increases? 1 mark Power, Energy, Charge 13) Calculate the power of a hair drier which, when connected to a 210V supply, has a current of 8A flowing through it. 2 marks 14) When a 1.5kW fire is connected to ...
Understanding patent claims
... least one tap, and a capacitor in each case in parallel with the two subwindings." Claim 2: "A device according to claim 1, characterised in that the capacitances and the numbers of windings are selected such that oscillations arising upon deactivation of the switch have different resonant frequenci ...
... least one tap, and a capacitor in each case in parallel with the two subwindings." Claim 2: "A device according to claim 1, characterised in that the capacitances and the numbers of windings are selected such that oscillations arising upon deactivation of the switch have different resonant frequenci ...
Low-power LVDS for digital readout circuits
... topology and a low-voltage supply are used in the system to reduce the power consumption. The switchable current source, as explained in former sections, utilizes one PMOS current source and an NMOS sink which are controlled by the digital input pulse and the common-mode feedback respectively. The c ...
... topology and a low-voltage supply are used in the system to reduce the power consumption. The switchable current source, as explained in former sections, utilizes one PMOS current source and an NMOS sink which are controlled by the digital input pulse and the common-mode feedback respectively. The c ...
“IRobot” EE241 Introductory Electronics Laboratory SYED MOHSIN
... 1) SUMMARY:The project is basically a ROBOT that uses fundamental electronics and follows infrared radiations from its surroundings (an IR beacon or source will be placed manually at any specified position randomly where we would like our robot to follow) and hence it is programmed to move in a cert ...
... 1) SUMMARY:The project is basically a ROBOT that uses fundamental electronics and follows infrared radiations from its surroundings (an IR beacon or source will be placed manually at any specified position randomly where we would like our robot to follow) and hence it is programmed to move in a cert ...
one-phase static meters ze 110
... How to start communication The beginning of communication can be either direct (with address) or indirect. The address can have up to eight characters (it may also include ASCII characters) and it is stored in the meter memory and can be set or changed using configuration of the unit. If the address ...
... How to start communication The beginning of communication can be either direct (with address) or indirect. The address can have up to eight characters (it may also include ASCII characters) and it is stored in the meter memory and can be set or changed using configuration of the unit. If the address ...
FST3244 — 8-Bit Bus Switch Features Description
... The FST3244 switch provides eight-bits of high-speed, CMOS, TTL-compatible bus switching in a standard ’244 pin-out. The low on resistance allows inputs to be connected to outputs without adding propagation delay or generating additional ground bounce noise. ...
... The FST3244 switch provides eight-bits of high-speed, CMOS, TTL-compatible bus switching in a standard ’244 pin-out. The low on resistance allows inputs to be connected to outputs without adding propagation delay or generating additional ground bounce noise. ...
Power Factor improved by Variable Speed AC Drives
... the power factor and thus reducing losses in the supply cables and transformers. It also avoids the cost of investment in power-factor-correction equipment. This article explains the reason for the phenomena, which may result in the input current to the Variable speed AC Drive can be lower than the ...
... the power factor and thus reducing losses in the supply cables and transformers. It also avoids the cost of investment in power-factor-correction equipment. This article explains the reason for the phenomena, which may result in the input current to the Variable speed AC Drive can be lower than the ...
SERIES AND PARALLEL CIRCUIT LAB
... SERIES AND PARALLEL CIRCUIT LAB Purpose: To discover the difference between series and parallel circuits using the knowledge of current all ready gained. Also to become acquainted with the digital multi-meter as a diagnostic tool. ...
... SERIES AND PARALLEL CIRCUIT LAB Purpose: To discover the difference between series and parallel circuits using the knowledge of current all ready gained. Also to become acquainted with the digital multi-meter as a diagnostic tool. ...
MAX8536EVKIT
... the MOSFETs, asserts a logic low on the FAULT output, and latches off when an overvoltage fault condition is detected. An overvoltage fault condition is detected only if the voltage at VBUS+ exceeds this threshold and the forward-current condition is established. The forward-current condition is def ...
... the MOSFETs, asserts a logic low on the FAULT output, and latches off when an overvoltage fault condition is detected. An overvoltage fault condition is detected only if the voltage at VBUS+ exceeds this threshold and the forward-current condition is established. The forward-current condition is def ...
Electricity - Uses of Electromagnetism
... This a step-down transformer because there are less turns in the secondary coil than the primary coil. ...
... This a step-down transformer because there are less turns in the secondary coil than the primary coil. ...
Fault Analysis on Distribution Feeders With Distributed Generators
... Fig. 4(b) shows the initial current transients of the voltage controlled IIDG during the first few cycles of the fault. Since the current varies considerably during this period, DG needs to be represented in enough detail so that the controller’s response can be taken into account and the peak curre ...
... Fig. 4(b) shows the initial current transients of the voltage controlled IIDG during the first few cycles of the fault. Since the current varies considerably during this period, DG needs to be represented in enough detail so that the controller’s response can be taken into account and the peak curre ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.