FLM-420-O8I2-S Octo-output Interface Module with 2 Inputs
... The maximum switchable voltage of the semiconductor outputs is 30 V DC. The maximum switchable current is 700 mA for each of the ouputs (depending on the external power supply). The activation of the inputs IN 1 and 2 has to be carried out electrically isolated from LSN (e. g. with relay contact, pu ...
... The maximum switchable voltage of the semiconductor outputs is 30 V DC. The maximum switchable current is 700 mA for each of the ouputs (depending on the external power supply). The activation of the inputs IN 1 and 2 has to be carried out electrically isolated from LSN (e. g. with relay contact, pu ...
R-MAG®Medium Voltage Tank Vacuum Magnetic
... voltage compartment to observe the mechanical operations. A manual trip handle is provided on the outside of the cabinet. (see Observe the positionindicator located on the front of the actuator cover plate. If the panel is green, the breaker is open, and if the panel is red, t ...
... voltage compartment to observe the mechanical operations. A manual trip handle is provided on the outside of the cabinet. (see Observe the positionindicator located on the front of the actuator cover plate. If the panel is green, the breaker is open, and if the panel is red, t ...
Document - Schneider Electric Belgique
... Sling up the device using the lifting lugs and place it on the ground. Unhook the slings and remove the handling parts and their screws. NB: the rings and screws must be kept for future use. ...
... Sling up the device using the lifting lugs and place it on the ground. Unhook the slings and remove the handling parts and their screws. NB: the rings and screws must be kept for future use. ...
AD8033/AD8034 Low Cost, 80 MHz FastFET Op Amps Data Sheet
... amplifiers with FET inputs, offering ease of use and excellent performance. The AD8033 is a single amplifier and the AD8034 is a dual amplifier. The AD8033/AD8034 FastFET op amps in Analog Devices, Inc., proprietary XFCB process offer significant performance improvements over other low cost FET amps ...
... amplifiers with FET inputs, offering ease of use and excellent performance. The AD8033 is a single amplifier and the AD8034 is a dual amplifier. The AD8033/AD8034 FastFET op amps in Analog Devices, Inc., proprietary XFCB process offer significant performance improvements over other low cost FET amps ...
Film Capacitors - Power Factor Correction - MKK525-D-20
... The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in t ...
... The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in t ...
Pantograph disconnector type GW54, up to 550 kV Maximum
... the highest records of operation reliability. The worldwide experience, often under severe climatic conditions, is applied for continual product improvement. Applications A mechanical device for providing isolation of power equipment from the network, a disconnector is suitable for switching very sm ...
... the highest records of operation reliability. The worldwide experience, often under severe climatic conditions, is applied for continual product improvement. Applications A mechanical device for providing isolation of power equipment from the network, a disconnector is suitable for switching very sm ...
VISHAY H11B3 datasheet
... 1. Annex A, B and list of transitional substances of the Montreal Protocol and the London Amendments respectively. 2. Class I and II ozone depleting substances in the Clean Air Act Amendments of 1990 by the Environmental Protection Agency (EPA) in the USA 3. Council Decision 88/540/EEC and 91/690/EE ...
... 1. Annex A, B and list of transitional substances of the Montreal Protocol and the London Amendments respectively. 2. Class I and II ozone depleting substances in the Clean Air Act Amendments of 1990 by the Environmental Protection Agency (EPA) in the USA 3. Council Decision 88/540/EEC and 91/690/EE ...
MKK525-D-20-02 - B25673A5202A020
... The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in t ...
... The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in t ...
Film Capacitors - Power Factor Correction - MKK415-D-20
... The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in t ...
... The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in t ...
BD6164GUT
... just before starting up the step-up DCDC converter. This ensures that any LED activity is blocked when the battery voltage is too low. During boost up, the system is not able to accurately detect the battery voltage (no separate VBAT pin on the chip), so the UVLO is disabled. In case of an under vol ...
... just before starting up the step-up DCDC converter. This ensures that any LED activity is blocked when the battery voltage is too low. During boost up, the system is not able to accurately detect the battery voltage (no separate VBAT pin on the chip), so the UVLO is disabled. In case of an under vol ...
DESCRIPTION
... The K661 provides a full scale output of ±300 VDC at up to 3 milliamperes of current. The unit can be programmed for 50, 100, or 200 volts per 1000 RPM by a jumper on TB1. The K661 provides a high conversion speed for a very stable linear output. Because only the encoder or pulse generator is mounte ...
... The K661 provides a full scale output of ±300 VDC at up to 3 milliamperes of current. The unit can be programmed for 50, 100, or 200 volts per 1000 RPM by a jumper on TB1. The K661 provides a high conversion speed for a very stable linear output. Because only the encoder or pulse generator is mounte ...
An Efficient SQRT Architecture of Carry Select
... SSRG International Journal of Electronics and Communication Engineering (SSRG-IJECE) – volume1 issue8 Oct 2014 ...
... SSRG International Journal of Electronics and Communication Engineering (SSRG-IJECE) – volume1 issue8 Oct 2014 ...
question bank - SIETK ECE Dept
... 7. (a) A 550 V, 55 KVA single phase alternator has an effective resistance of 0.2Ω. A field current of 10A produces an armature current of short circuit and an emf of 450 V of open circuit. calculate i)synchronous impedance and reactance ii) full load regulation when the power factor is 0.8 lagging. ...
... 7. (a) A 550 V, 55 KVA single phase alternator has an effective resistance of 0.2Ω. A field current of 10A produces an armature current of short circuit and an emf of 450 V of open circuit. calculate i)synchronous impedance and reactance ii) full load regulation when the power factor is 0.8 lagging. ...
R5205CND
... scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk ...
... scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk ...
MMST4403 Features Mechanical Data
... express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. ...
... express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. ...
BDTIC www.BDTIC.com/infineon Solutions for Industrial Drives Electronic speed-control systems save energy and
... two-thirds of electrical energy consumed in industry and they are a central component of automation systems. There are two distinct groups in the industrial drive technology. The first group includes electrically driven machines requiring position control. This group includes, for example, machine t ...
... two-thirds of electrical energy consumed in industry and they are a central component of automation systems. There are two distinct groups in the industrial drive technology. The first group includes electrically driven machines requiring position control. This group includes, for example, machine t ...
Reverse Battery Protection
... Figure 1 shows an example of a solution using 45V rated Schottky diode(s). The total power losses as a function of the power rating of the load with the assumption of a battery voltage of 14V are shown. If the power losses at high output powers can not be handled by one diode, several devices have t ...
... Figure 1 shows an example of a solution using 45V rated Schottky diode(s). The total power losses as a function of the power rating of the load with the assumption of a battery voltage of 14V are shown. If the power losses at high output powers can not be handled by one diode, several devices have t ...
10 kW Contactless Power Transfer System for Rapid Charger of
... increases with increasing power. This overvoltage may lead to the problem of breakdown voltage of capacitor and the breakdown of winding insulation. To prevent such an overvoltage occurring, it is suggested that the primary winding and the series capacitor are split into two pieces or more respectiv ...
... increases with increasing power. This overvoltage may lead to the problem of breakdown voltage of capacitor and the breakdown of winding insulation. To prevent such an overvoltage occurring, it is suggested that the primary winding and the series capacitor are split into two pieces or more respectiv ...
MAX17019 High-Input-Voltage Quad
... MOSFET. The MAX17019 also includes output undervoltage, output overvoltage, and thermal-fault protection. ...
... MOSFET. The MAX17019 also includes output undervoltage, output overvoltage, and thermal-fault protection. ...
NOISE MEASUREMENTS OF THE POWER TRANSFORMERS
... of power transformers in ABS Minel Transformers factory in Ripanj, thus confirming high technological level and product’s quality, both in terms of transformation of electrical energy, and from the aspect of environmental protection. 1. INTRODUCTION High power transformers are installed on hydro pow ...
... of power transformers in ABS Minel Transformers factory in Ripanj, thus confirming high technological level and product’s quality, both in terms of transformation of electrical energy, and from the aspect of environmental protection. 1. INTRODUCTION High power transformers are installed on hydro pow ...
Power inverter
A power inverter, or inverter, is an electronic device or circuitry that changes direct current (DC) to alternating current (AC).The input voltage, output voltage and frequency, and overall power handling depend on the design of the specific device or circuitry. The inverter does not produce any power; the power is provided by the DC source.A power inverter can be entirely electronic or may be a combination of mechanical effects (such as a rotary apparatus) and electronic circuitry.Static inverters do not use moving parts in the conversion process.