• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
NVT2003/04/06 1. General description Bidirectional voltage-level translator for open-drain and
NVT2003/04/06 1. General description Bidirectional voltage-level translator for open-drain and

... push-pull applications. Bit widths ranging from 3-bit to 6-bit are offered for level translation application with transmission speeds < 33 MHz for an open-drain system with a 50 pF capacitance and a pull-up of 197 . When the An or Bn port is LOW, the clamp is in the ON-state and a low resistance co ...
l06055engf
l06055engf

... The braking torque indicated is a short-duration average torque (which varies with motor loss) when the motor alone is decelerated from 60Hz in the shortest time and is not a continuous regenerative torque. When the motor is decelerated from the frequency higher than the base frequency, the average ...
TAC I/NET - eschneider.pl
TAC I/NET - eschneider.pl

Laboratory Manual for Semiconductor Devices
Laboratory Manual for Semiconductor Devices

... shaft half way, for example, results in a 50/50 split of the resistance. In contrast, an audio taper pot would show a 10/90 split. Pots are also available in multi-gang, that is, several pots controlled by one common shaft. ...
Navy Electricity and Electronics Training Series
Navy Electricity and Electronics Training Series

ADM1276 数据手册DataSheet 下载
ADM1276 数据手册DataSheet 下载

... The ADM1276 is a hot swap controller that allows a circuit board to be removed from or inserted into a live backplane. It also features current and voltage readback via an integrated 12-bit analog-todigital converter (ADC), accessed using a PMBus™ interface. The load current is measured using an int ...
Laboratory Manual
Laboratory Manual

... shaft half way, for example, results in a 50/50 split of the resistance. In contrast, an audio taper pot would show a 10/90 split. Pots are also available in multi-gang, that is, several pots controlled by one common shaft. ...
Laboratory Manual - Mohawk Valley Community College
Laboratory Manual - Mohawk Valley Community College

... shaft half way, for example, results in a 50/50 split of the resistance. In contrast, an audio taper pot would show a 10/90 split. Pots are also available in multi-gang, that is, several pots controlled by one common shaft. ...
Current Controlled Driver for 24-V DC Solenoid
Current Controlled Driver for 24-V DC Solenoid

BDTIC www.BDTIC.com/infineon  Power Management and Multimarket
BDTIC www.BDTIC.com/infineon Power Management and Multimarket

... 1) IC gets deactivated once the supply voltage drops below VS, UV, off and gets operative once supply voltage rises above VS, UV, on. 2) Reset timer starts after supply voltage exceeds the lower limit of the supply voltage. Output stage gets enabled once reset timer expires. 3) Once the over current ...
Avionics Guide
Avionics Guide

... N-channel MOSFET. Included on the substrate with the listed features are a highperformance voltage error amplifier that provides tight voltage regulation accuracy under transient conditions, an undervoltage-lockout circuit to prevent start-up until the input voltage reaches 5.5 V, an internally set ...
Important notice Dear Customer, On 7 February 2017 the former
Important notice Dear Customer, On 7 February 2017 the former

... The 74ALVCH162827 20-bit buffers provide high performance bus interface buffering for wide data/address paths or buses carrying parity. They have NAND Output Enables (nOE1, nOE2) for maximum control flexibility. The 74ALVCH162827 is designed with 30Ω series resistance in both the pull-up and pull-do ...
Manual.
Manual.

MAX9312/MAX9314 Dual 1:5 Differential LVPECL/LVECL/HSTL Clock and Data Drivers General Description
MAX9312/MAX9314 Dual 1:5 Differential LVPECL/LVECL/HSTL Clock and Data Drivers General Description

... The MAX9312/MAX9314 are low-skew, dual 1-to-5 differential drivers designed for clock and data distribution. For interfacing to differential HSTL and LVPECL signals, these devices operate over a +2.25V to +3.8V supply range, allowing high-performance clock or data distribution in systems with a nomi ...
ECE2120 Prelabs
ECE2120 Prelabs

RS Series AC and DC Power Source User Manual
RS Series AC and DC Power Source User Manual

... Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis. Similarly, other power ground lines including those to application and maintenance equipment must be grounded properly for both personnel and equipment safety. Always ensure that facility AC inpu ...
RS Series AC and DC Power Source User Manual
RS Series AC and DC Power Source User Manual

... Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis. Similarly, other power ground lines including those to application and maintenance equipment must be grounded properly for both personnel and equipment safety. Always ensure that facility AC inpu ...
NVT2008; NVT2010 1. General description Bidirectional voltage-level translator for open-drain and
NVT2008; NVT2010 1. General description Bidirectional voltage-level translator for open-drain and

... between 1.0 V and 5 V without the need for a direction pin in open-drain or push-pull applications. Bit widths of 8-bit to 10-bit are offered for level translation application with transmission speeds < 33 MHz for an open-drain system with a 50 pF capacitance and a pull-up of 197 . When the An or B ...
Safety Manual Eagle Quantum Premier SIL 2 Rated Fire &amp; Gas System ®
Safety Manual Eagle Quantum Premier SIL 2 Rated Fire & Gas System ®

... taken to use the Det-Tronics Eagle Quantum Premier® (EQP) Safety System in safety-related applications. The actions that are described can be either technical or procedural. For example, a procedural action would be the need to maintain password protection of configuration programs, so that non-appr ...
AD9863
AD9863

LT1991 - Precision, 100µA Gain Selectable Amplifier
LT1991 - Precision, 100µA Gain Selectable Amplifier

... Strain Gauge Amplifiers Differential to Single-Ended Conversion ...
document
document

... TOF, PET, or FLIM applications. We employ a two-stage architecture, wherein the first stage operates as a coarse TDC (first TDC), the time residue is amplified by a time difference amplifier (TDA), then it is converted by the second-stage TDC (second TDC). The advantage of the two-stage TDC is not only ...
WT1800 Precision Power Analyzer Getting Started Guide User’s
WT1800 Precision Power Analyzer Getting Started Guide User’s

... Power meters can measure large voltages and currents directly. If you use a voltage transformer or a current transformer together with this power meter, you can measure even larger voltages or currents. When you are measuring a large voltage or current, the power capacity of the item under measureme ...
MAX9322 LVECL/LVPECL 1:15 Differential Divide-by-1/Divide-by-2 Clock Driver General Description
MAX9322 LVECL/LVPECL 1:15 Differential Divide-by-1/Divide-by-2 Clock Driver General Description

... reproduces or divides one of two differential input clocks at 15 differential outputs. An input multiplexer selects from one of two input clocks with input switching frequency in excess of 1.0GHz. The 15 outputs are arranged in four banks with 2, 3, 4, and 6 outputs, respectively. Each output bank i ...
31_InstructorSolutionsWin
31_InstructorSolutionsWin

... EVALUATE: The instantaneous potential differences across all the circuit elements always add up to the value of the source voltage at that instant. In this case (resonance), the potentials across the inductor and capacitor have the same magnitude but are 180° out of phase, so they add to zero, leavi ...
< 1 ... 12 13 14 15 16 17 18 19 20 ... 661 >

Integrating ADC



An integrating ADC is a type of analog-to-digital converter that converts an unknown input voltage into a digital representation through the use of an integrator. In its most basic implementation, the unknown input voltage is applied to the input of the integrator and allowed to ramp for a fixed time period (the run-up period). Then a known reference voltage of opposite polarity is applied to the integrator and is allowed to ramp until the integrator output returns to zero (the run-down period). The input voltage is computed as a function of the reference voltage, the constant run-up time period, and the measured run-down time period. The run-down time measurement is usually made in units of the converter's clock, so longer integration times allow for higher resolutions. Likewise, the speed of the converter can be improved by sacrificing resolution.Converters of this type can achieve high resolution, but often do so at the expense of speed. For this reason, these converters are not found in audio or signal processing applications. Their use is typically limited to digital voltmeters and other instruments requiring highly accurate measurements.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report