ADC Successive Approximation Register
... rate. Enter the conversion rate in samples per second. Converting one sample takes 19 SAR ADC clock cycles. Clock Frequency This text box is a read-only (always grayed out) area that displays the required clock rate for the selected operating conditions: resolution and conversion rate. It is updated ...
... rate. Enter the conversion rate in samples per second. Converting one sample takes 19 SAR ADC clock cycles. Clock Frequency This text box is a read-only (always grayed out) area that displays the required clock rate for the selected operating conditions: resolution and conversion rate. It is updated ...
Uninterruptible Power Supply User’s manual EVO DSP TT
... The equipment may only be installed and commissioned by authorized technical persons. When the UPS is brought from a cold place to a warmer place, humidity in the air may cause condensation in the UPS. In this case, allow UPS to stand for two hours in the warmer place before beginning with the i ...
... The equipment may only be installed and commissioned by authorized technical persons. When the UPS is brought from a cold place to a warmer place, humidity in the air may cause condensation in the UPS. In this case, allow UPS to stand for two hours in the warmer place before beginning with the i ...
WT310E/WT310EH/WT332E/WT333E Digital Power Meter User’s Manual IM WT310E-01EN
... Symbols and Conventions Used in Procedural Explanations The contents of the procedural explanations are indicated using the following symbols. ...
... Symbols and Conventions Used in Procedural Explanations The contents of the procedural explanations are indicated using the following symbols. ...
M-3410A-INSTRUCTION BOOK - Chipkin Automation Systems
... The two programmable output relays, each with a contact are rated as per ANSI/IEEE C37.90-1989 for tripping: make 30 A for 0.2 seconds. Available hardware configurations include two normally open (Option B1), one normally open and one normally closed (Option B2), or two normally closed (Option B3) c ...
... The two programmable output relays, each with a contact are rated as per ANSI/IEEE C37.90-1989 for tripping: make 30 A for 0.2 seconds. Available hardware configurations include two normally open (Option B1), one normally open and one normally closed (Option B2), or two normally closed (Option B3) c ...
Power Factor Correction Handbook
... Designing power supplies in a global energy efficiency context Designing power supplies has always been a challenging task. But just as many of the traditional problems have been solved, emerging regulatory standards governing efficiency levels are about to start the cycle over again. The first phas ...
... Designing power supplies in a global energy efficiency context Designing power supplies has always been a challenging task. But just as many of the traditional problems have been solved, emerging regulatory standards governing efficiency levels are about to start the cycle over again. The first phas ...
Operator`s Manual
... and clear of all liens or other encumbrances. The refund will be equal to the actual purchase price, not including interest, insurance, closing costs, and other finance charges less a reasonable depreciation on the product from the date of original purchase. Warranty work can only be performed at ou ...
... and clear of all liens or other encumbrances. The refund will be equal to the actual purchase price, not including interest, insurance, closing costs, and other finance charges less a reasonable depreciation on the product from the date of original purchase. Warranty work can only be performed at ou ...
CHAPTER 2 Harmonic Analysis of Star-Delta Inverter
... I would like to sincerely thank to Assist. Prof. Dr. Özgür ÖZERDEM for his invaluable supervision, support and encouragement through this work. I would like especially to express my sincere thanks to Prof. Dr. Sezai DİNÇER and Assoc. Prof. Dr. Murat FAHRİOĞLU for their updates and corrections on thi ...
... I would like to sincerely thank to Assist. Prof. Dr. Özgür ÖZERDEM for his invaluable supervision, support and encouragement through this work. I would like especially to express my sincere thanks to Prof. Dr. Sezai DİNÇER and Assoc. Prof. Dr. Murat FAHRİOĞLU for their updates and corrections on thi ...
44. controlled switching of high voltage sf6 circuit breaker
... conventional approach is to design the system components, such as capacitor banks, transformers, and circuit breakers, to withstand the voltage and current transients associated with frequent occurrence of worst case switching phenomena.This is a new method which is becoming popular day by day for t ...
... conventional approach is to design the system components, such as capacitor banks, transformers, and circuit breakers, to withstand the voltage and current transients associated with frequent occurrence of worst case switching phenomena.This is a new method which is becoming popular day by day for t ...
CD4067 CD4097
... When switching from one address to another, some of the ON periods of the channels of the multiplexers will overlap momentarily, which may be objectionable in certain applications. Also when a channel is turned on or off by an address input, there is a momentary conductive path from the channel to V ...
... When switching from one address to another, some of the ON periods of the channels of the multiplexers will overlap momentarily, which may be objectionable in certain applications. Also when a channel is turned on or off by an address input, there is a momentary conductive path from the channel to V ...
WT310/WT310HC/WT330 Digital Power Meter User’s Manual IM WT310-01EN
... WT310HC/WT330 features, except for the communication interface features, and how to use them. Provided as a printed manual. This manual explains the handling precautions and basic operations of the WT310/WT310HC/WT330 and provides an overview of its features. This manual explains the WT310/WT310HC/W ...
... WT310HC/WT330 features, except for the communication interface features, and how to use them. Provided as a printed manual. This manual explains the handling precautions and basic operations of the WT310/WT310HC/WT330 and provides an overview of its features. This manual explains the WT310/WT310HC/W ...
Electronics Switches Terry Sturtevant April 6, 2011
... In a logic circuit, you usually want a switch to connect you to one of two things; VCC or ground. AN UNCONNECTED INPUT IS NOT AUTOMATICALLY GROUNDED!!!! ...
... In a logic circuit, you usually want a switch to connect you to one of two things; VCC or ground. AN UNCONNECTED INPUT IS NOT AUTOMATICALLY GROUNDED!!!! ...
Integrating ADC
An integrating ADC is a type of analog-to-digital converter that converts an unknown input voltage into a digital representation through the use of an integrator. In its most basic implementation, the unknown input voltage is applied to the input of the integrator and allowed to ramp for a fixed time period (the run-up period). Then a known reference voltage of opposite polarity is applied to the integrator and is allowed to ramp until the integrator output returns to zero (the run-down period). The input voltage is computed as a function of the reference voltage, the constant run-up time period, and the measured run-down time period. The run-down time measurement is usually made in units of the converter's clock, so longer integration times allow for higher resolutions. Likewise, the speed of the converter can be improved by sacrificing resolution.Converters of this type can achieve high resolution, but often do so at the expense of speed. For this reason, these converters are not found in audio or signal processing applications. Their use is typically limited to digital voltmeters and other instruments requiring highly accurate measurements.