dual full-bridge pwm motor driver
... load current peak will be slightly higher than the trip point (especially for low-inductance loads) because of the internal logic and switching delays. This delay (t d ) is typically 2 µs. After turn-off, the motor current decays, circulating through the ground-clamp diode and sink transistor. The s ...
... load current peak will be slightly higher than the trip point (especially for low-inductance loads) because of the internal logic and switching delays. This delay (t d ) is typically 2 µs. After turn-off, the motor current decays, circulating through the ground-clamp diode and sink transistor. The s ...
minimum position actuator interface
... controlled by DC voltage, with any generic Energy Management System. Typical applications include minimum position adjustment, actuators ‘sequencing’ and boosting of analog output driving capacity. The board may be manufactured for a non-standard voltage levels and used for input/output voltage re-s ...
... controlled by DC voltage, with any generic Energy Management System. Typical applications include minimum position adjustment, actuators ‘sequencing’ and boosting of analog output driving capacity. The board may be manufactured for a non-standard voltage levels and used for input/output voltage re-s ...
X-Ray Main Disconnect Panel - Bevco Imaging Suite Controls
... loss. The system incorporates a brief delay before re‐energizing to allow for the incoming power to stabilize, reducing the potential for damage to sensitive electronic devices typically encountered when switching to generator power. Room Lighting and "In‐Use" Warning Light Control option. Ful ...
... loss. The system incorporates a brief delay before re‐energizing to allow for the incoming power to stabilize, reducing the potential for damage to sensitive electronic devices typically encountered when switching to generator power. Room Lighting and "In‐Use" Warning Light Control option. Ful ...
500-775 HCMU Datasheet.indd
... High Current Management Unit Moog’s High Current Management Unit (HCMU) is a 28V, high output current, smart power controller. An extremely efficient power drive design is capable of delivering in excess of 36kW (steady-state) of output power with greater than 99% unit efficiency. Utilizing Moog’s h ...
... High Current Management Unit Moog’s High Current Management Unit (HCMU) is a 28V, high output current, smart power controller. An extremely efficient power drive design is capable of delivering in excess of 36kW (steady-state) of output power with greater than 99% unit efficiency. Utilizing Moog’s h ...
PPT
... • Output is a function of the inputs only • Similar to a pure function in mathematics, y=f(x). No way to store information, no side effects • If we change X, Y will change immediately (after a short delay) • Very important: This is not like a function call! f is active and doing what it does continu ...
... • Output is a function of the inputs only • Similar to a pure function in mathematics, y=f(x). No way to store information, no side effects • If we change X, Y will change immediately (after a short delay) • Very important: This is not like a function call! f is active and doing what it does continu ...
Maxstar 150 S
... Adaptive Hot Start™ for Stick arc starts, automatically increases the output amperage at the start of a weld should the start require it. Prevents the electrode from sticking and creating an inclusion. ...
... Adaptive Hot Start™ for Stick arc starts, automatically increases the output amperage at the start of a weld should the start require it. Prevents the electrode from sticking and creating an inclusion. ...
AV100-750 - Europower Components Ltd
... Overall Accuracy @ VPN , TA = + 25°C Overall Accuracy @ VPN , TA = - 25 .. + 70°C Overall Accuracy @ VPN , TA = - 40 .. + 85°C Linearity @ TA = 25°C Offset current @ VP = 0, TA = 25°C Response time @ 10 % of VPmax Frequency bandwidth (- 3 dB) ...
... Overall Accuracy @ VPN , TA = + 25°C Overall Accuracy @ VPN , TA = - 25 .. + 70°C Overall Accuracy @ VPN , TA = - 40 .. + 85°C Linearity @ TA = 25°C Offset current @ VP = 0, TA = 25°C Response time @ 10 % of VPmax Frequency bandwidth (- 3 dB) ...
STRMH International Future Energy Challenge ‘07
... operation Interact with user interface to produce desired operation ...
... operation Interact with user interface to produce desired operation ...
Ch04
... Pulse compression in the conversion, using a matched filter, of a relative long coded pulse to one of short time duration, excellent resolution, and equivalent high intensity and sensitivity. A match filter maximizes the signal-to-noise ratio (SNR) of the returning signal. The longer the coded pulse ...
... Pulse compression in the conversion, using a matched filter, of a relative long coded pulse to one of short time duration, excellent resolution, and equivalent high intensity and sensitivity. A match filter maximizes the signal-to-noise ratio (SNR) of the returning signal. The longer the coded pulse ...
Unit 2 PowerPoint Slides
... •Each switch is either on or off at any given time. •Unlike manual switches that require a person to switch them, we need automatic switches that can be turned on or off by the voltage level (HIGH or LOW) present at the switch’s control input. ...
... •Each switch is either on or off at any given time. •Unlike manual switches that require a person to switch them, we need automatic switches that can be turned on or off by the voltage level (HIGH or LOW) present at the switch’s control input. ...
MAXIMUM POWER TRANSFER THEOREM
... In many electrical and electronic applications, we are interested in the amount of power received by a particular load (speaker, electric motor, antenna) Electric systems are a source of power and a load connected to that source Sources – Amplifiers, generators, power supplies All linearly construct ...
... In many electrical and electronic applications, we are interested in the amount of power received by a particular load (speaker, electric motor, antenna) Electric systems are a source of power and a load connected to that source Sources – Amplifiers, generators, power supplies All linearly construct ...
Fuzzy Controlled Cascaded H-Bridge Multilevel Inverter
... faults could also inflict power quality (PQ) problems. PQ problem is defined as any manifested problem in voltage current or leading to frequency deviations that result in failure or mal operation of customer equipment. Voltage sags and swells are among the many PQ problems the industrial processes ...
... faults could also inflict power quality (PQ) problems. PQ problem is defined as any manifested problem in voltage current or leading to frequency deviations that result in failure or mal operation of customer equipment. Voltage sags and swells are among the many PQ problems the industrial processes ...
Lecture 36
... of duty cycle, 2 transistors • Here, the controller duty cycle Dc is defined as the duty cycle that would be chosen by a conventional PWM chip. ...
... of duty cycle, 2 transistors • Here, the controller duty cycle Dc is defined as the duty cycle that would be chosen by a conventional PWM chip. ...
Arduino, PWM, MOSFETs and Motors
... temperature, but begins to spin as you heat the thermistor. Adjust the gain so that the motor response is not too extreme. See if you can get the motor to run at a near steady state where the heat added to the thermistor is dissipated by the air the motor fans on it. Show the final result to one of ...
... temperature, but begins to spin as you heat the thermistor. Adjust the gain so that the motor response is not too extreme. See if you can get the motor to run at a near steady state where the heat added to the thermistor is dissipated by the air the motor fans on it. Show the final result to one of ...
CPC 1822 Specifications - San Jose State University
... included in the circuit setup. The buffer copies the voltage reading from the sensor and forces current to the copied output voltage. To improve noise at the output, a RC low-pass filter is implemented in conjunction with an op-amp, capacitor and resistor. The capacitor would have a fixed capacitanc ...
... included in the circuit setup. The buffer copies the voltage reading from the sensor and forces current to the copied output voltage. To improve noise at the output, a RC low-pass filter is implemented in conjunction with an op-amp, capacitor and resistor. The capacitor would have a fixed capacitanc ...
Transient signals
... Way - number of conducting positions, three or more. Open - off position, contacts not conducting. Closed - on position, contacts conducting, there may be several on positions. ...
... Way - number of conducting positions, three or more. Open - off position, contacts not conducting. Closed - on position, contacts conducting, there may be several on positions. ...
1.1 Digital vs. analog sensors
... the characteristic (light, temperature, etc.) that they measure. Meters are then used to measure the resulting voltage or current. That voltage or current signal can then be converted into a meaningful num ...
... the characteristic (light, temperature, etc.) that they measure. Meters are then used to measure the resulting voltage or current. That voltage or current signal can then be converted into a meaningful num ...
International Journal of Science, Engineering and Technology
... resources that recently has become broader in nowadays technology. The electricity generations of photo voltaic (PV) panels are strongly related with insolation and temperature. The insolation and temperature are not stable, since the electricity generations of the PV panels are not stable. In PV sy ...
... resources that recently has become broader in nowadays technology. The electricity generations of photo voltaic (PV) panels are strongly related with insolation and temperature. The insolation and temperature are not stable, since the electricity generations of the PV panels are not stable. In PV sy ...
Multichannel Waveform Generator
... current into pFET gate when on • IN is either high or low voltage resulting in passing current or open ...
... current into pFET gate when on • IN is either high or low voltage resulting in passing current or open ...
[2] block diagram of dstatcom
... low efficiency and if the voltage supplied is above the rated windings get damaged. Hence in order to provide reliable uniform, power modern method of mitigation is use of STATCOM. A battery energy system is used to supply the reactive power which is connected shunt with capacitor bank. The STATCOMs ...
... low efficiency and if the voltage supplied is above the rated windings get damaged. Hence in order to provide reliable uniform, power modern method of mitigation is use of STATCOM. A battery energy system is used to supply the reactive power which is connected shunt with capacitor bank. The STATCOMs ...
Pulse-width modulation
Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.