RA07H4452M 数据资料DataSheet下载
... critical communications elements would include transmitters for base station applications and fixed station applications that operate with long term continuous transmission and a higher on-off frequency during transmitting, especially for systems that may have a high impact to society. 3.RA series p ...
... critical communications elements would include transmitters for base station applications and fixed station applications that operate with long term continuous transmission and a higher on-off frequency during transmitting, especially for systems that may have a high impact to society. 3.RA series p ...
a new topological method for determination of the equivalent
... We obtain the same value of sensitivity using the both procedures, but the second procedure it is more complicated. The numerical value of sensitivity proves a smaller increase, 23 .2% , of sensitivity compared to a parameter ...
... We obtain the same value of sensitivity using the both procedures, but the second procedure it is more complicated. The numerical value of sensitivity proves a smaller increase, 23 .2% , of sensitivity compared to a parameter ...
the fourth state - Automotive Test Solutions
... The “Time to Tail” shows the time the transformer had to discharge the energy and how much energy was still remaining in the transformer. In this case the burn time is only .6ms and the energy remaining in the transformer is only -1.5k volts. With only .6ms of time to discharge the energy that was ...
... The “Time to Tail” shows the time the transformer had to discharge the energy and how much energy was still remaining in the transformer. In this case the burn time is only .6ms and the energy remaining in the transformer is only -1.5k volts. With only .6ms of time to discharge the energy that was ...
PM150/PM240 Installation manual
... Input, output and case are galvanically separated from each other. You can thus choose how you want the system connected. The input is protected against reverse polarity by a parallel diode at the input on models with input code A, B, 24 and 48. This diode, however, is only intended to blow an exter ...
... Input, output and case are galvanically separated from each other. You can thus choose how you want the system connected. The input is protected against reverse polarity by a parallel diode at the input on models with input code A, B, 24 and 48. This diode, however, is only intended to blow an exter ...
4.5V TO 18V INPUT 10 PIN SYNCHRONOUS
... COMP pin and determines the short circuit protection threshold voltage, by placing 400 mV on the COMP pin for approximately 1 ms. During this time, the current is measured and compared against internal thresholds to select the short circuit protection threshold. After this, the COMP pin is brought l ...
... COMP pin and determines the short circuit protection threshold voltage, by placing 400 mV on the COMP pin for approximately 1 ms. During this time, the current is measured and compared against internal thresholds to select the short circuit protection threshold. After this, the COMP pin is brought l ...
ISL9K460P3 8 A, 600 V, STEALTH II Diode —
... The ISL9K460P3 is a STEALTH™ dual diode optimized for low loss performance in high frequency hard switched applications. The STEALTH™ family exhibits low reverse recovery current (Irr) and exceptionally soft recovery under typical operating conditions. This device is intended for use as a free wheel ...
... The ISL9K460P3 is a STEALTH™ dual diode optimized for low loss performance in high frequency hard switched applications. The STEALTH™ family exhibits low reverse recovery current (Irr) and exceptionally soft recovery under typical operating conditions. This device is intended for use as a free wheel ...
MP174 - Monolithic Power System
... Start-Up and Under-Voltage Lockout The internal high-voltage regulator self-supplies the IC from the Drain pin. When VCC voltage reaches 5.6V, the IC starts switching and the internal high voltage regulator turns off. The internal high-voltage regulator turns on to charge the external VCC capacitor ...
... Start-Up and Under-Voltage Lockout The internal high-voltage regulator self-supplies the IC from the Drain pin. When VCC voltage reaches 5.6V, the IC starts switching and the internal high voltage regulator turns off. The internal high-voltage regulator turns on to charge the external VCC capacitor ...
SDM20U40 Features Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
ppt
... Mesh: A loop that does not enclose any other loops Branch: A circuit path that contains two nodes Loop: A path with starting node=last node; can contain many meshes EE 1270 Introduction to Electric Circuits ...
... Mesh: A loop that does not enclose any other loops Branch: A circuit path that contains two nodes Loop: A path with starting node=last node; can contain many meshes EE 1270 Introduction to Electric Circuits ...
AD629 数据手册DataSheet 下载
... from mixed-signal components, such as ADCs, should return through a low impedance analog ground plane. Digital ground lines of mixed-signal converters should also be connected to the analog ground plane. Typically, analog and digital grounds should be separated; however, it is also a requirement to ...
... from mixed-signal components, such as ADCs, should return through a low impedance analog ground plane. Digital ground lines of mixed-signal converters should also be connected to the analog ground plane. Typically, analog and digital grounds should be separated; however, it is also a requirement to ...
Lab06_La_Juan
... device. The device shows a variant number. Therefore the recorded data is an estimate or average of the fluctuation quantity. The device used in the experiment also contributed to errors. Each device has a deviation, so it adds to the affects of the result of the experiment. In the experiment, there ...
... device. The device shows a variant number. Therefore the recorded data is an estimate or average of the fluctuation quantity. The device used in the experiment also contributed to errors. Each device has a deviation, so it adds to the affects of the result of the experiment. In the experiment, there ...
P85060
... patented sync protocol, Wheelock DSM sync modules, Wheelock power supplies, or SAFEPATH family of products. The Strobe Appliances are UL Listed under Standard 1971 (Signaling Devices for the Hearing Impaired) for indoor Fire Protection Service. They are listed for indoor use only. Cooper Notificatio ...
... patented sync protocol, Wheelock DSM sync modules, Wheelock power supplies, or SAFEPATH family of products. The Strobe Appliances are UL Listed under Standard 1971 (Signaling Devices for the Hearing Impaired) for indoor Fire Protection Service. They are listed for indoor use only. Cooper Notificatio ...
TPS6217x 3-V to 17-V, 0.5-A Step-Down
... The TPS6217x synchronous step-down DC-DC converters are based on DCS-Control™ (Direct Control with Seamless transition into power save mode), an advanced regulation topology, that combines the advantages of hysteretic, voltage mode and current mode control including an AC loop directly associated to ...
... The TPS6217x synchronous step-down DC-DC converters are based on DCS-Control™ (Direct Control with Seamless transition into power save mode), an advanced regulation topology, that combines the advantages of hysteretic, voltage mode and current mode control including an AC loop directly associated to ...
DATA SHEET PBSS5540Z 40 V low V PNP transistor
... The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any lice ...
... The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any lice ...
MAX258 500mA, Push-Pull Transformer Driver for Isolated Power Supplies General Description
... Transformer selection for the MAX258 can be simplified by the use of the ET product. The ET product relates the maximum allowable magnetic flux density in a transformer core to the voltage across a winding and switching period. Inductor magnetizing current in the primary winding changes linearly wit ...
... Transformer selection for the MAX258 can be simplified by the use of the ET product. The ET product relates the maximum allowable magnetic flux density in a transformer core to the voltage across a winding and switching period. Inductor magnetizing current in the primary winding changes linearly wit ...
数据资料缩写本 DS28EL25 DeepCover安全认证器, 带有1-Wire SHA-256和4Kb用户EEPROM
... Note 1: Limits are 100% production tested at TA = +25°C and/or TA = +85°C. Limits over the operating temperature range and relevant supply voltage range are guaranteed by design and characterization. Typical values are not guaranteed. Note 2: System requirement. Note 3: Maximum allowable pullup r ...
... Note 1: Limits are 100% production tested at TA = +25°C and/or TA = +85°C. Limits over the operating temperature range and relevant supply voltage range are guaranteed by design and characterization. Typical values are not guaranteed. Note 2: System requirement. Note 3: Maximum allowable pullup r ...
Surge protector
A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".