• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Design optimizations of phase noise, power consumption and
Design optimizations of phase noise, power consumption and

Principles of Electrical Grounding
Principles of Electrical Grounding

PR570TRN
PR570TRN

... 1 Do not use an isolation transformer for this test. Plug the completely reassembled unit directly into the ac outlet. 2 Connect a 1.5K, 10W resistor paralleled by an .015uF capacitor between each exposed metal cabinet part and a good earth ground such as a water pipe, as shown above. 3 Use an ac vo ...
Insulation condition assessment of medium voltage power
Insulation condition assessment of medium voltage power

... spectrum analyser ...
The control of VSC-HVDC and its use for large industrial power
The control of VSC-HVDC and its use for large industrial power

... The thesis deals with the control of VSC-HVDC, the use of VSC-HVDC in a passive industrial system and the system design with different dc voltage levels. The objective of the work is to assess the potential and limitation of the use of dc distribution in industrial power systems. A model of a VSC ba ...
CHAPTER 3:  SiGe MONOLITHIC TECHNOLOGIES
CHAPTER 3: SiGe MONOLITHIC TECHNOLOGIES

... 3.7.1 Inductor and RF-line layout considerations To ensure enough resistance between the spiral and the substrate contacts surrounding it for decoupling, all contacts must be placed at least 80 μm from the spiral. If not the simulation results obtained with the ideal AC ground connection are no long ...
ILCT6/MCT6
ILCT6/MCT6

... 2. Regularly and continuously improve the performance of our products, processes, distribution and operating systems with respect to their impact on the health and safety of our employees and the public, as well as their impact on the environment. It is particular concern to control or eliminate rel ...
3.3-V/5-V Multichannel RS-232 Line Driver/Receiver (Rev. D
3.3-V/5-V Multichannel RS-232 Line Driver/Receiver (Rev. D

AN162 : Power On Conditions for the X9258
AN162 : Power On Conditions for the X9258

2SP0325T Preliminary Description & Application Manual
2SP0325T Preliminary Description & Application Manual

Diagram of circuit
Diagram of circuit

... - It has the same property as the diode that it allows current to pass through in one direction only. - It uses much less electricity than an ordinary light bulb. - The color of the LED will depend on the type of material (semi-conductor) used to make it. ...
computemp 255 binary thermometer kit
computemp 255 binary thermometer kit

... voltage range we are able to work with. The outputs of the counter can’t actually achieve 5 volts with the LEDs on the output, but really close at 4.67V. We then figure what the voltage will be across R38 when all outputs of the counter are at 4.67V and we will have the maximum output of our DAC. In ...
LPS 3 web - ChemCenters
LPS 3 web - ChemCenters

... LPS 3 Heavy-Duty Rust Inhibitor is a specially formulated long term corrosion inhibitor which will protect metal parts stored indoors for up to two years. When applied it forms a soft, transparent, waxy film which acts as an effective barrier sealing out moisture, air, acid, alkali fumes and other c ...
NEMA 4X, PWM DC Control
NEMA 4X, PWM DC Control

... battery is being connected to the drive. Another advantage of using the contactor is that it serves as an additional safety device to protect against a run away condition, some cases of reverse polarity battery connection, and excessive charging voltages. Once the drive is enabled, the coil output w ...
PAH-28/12.5-D48NB-C Datasheet
PAH-28/12.5-D48NB-C Datasheet

... Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied nor recommended. Output Current ...
TPS55383 数据资料 dataSheet 下载
TPS55383 数据资料 dataSheet 下载

... supporting 3-A output applications that operate from a 4.5-V to 28-V input supply voltage, and require output voltages between 0.8 V and 90% of the input voltage. With an internally-determined operating frequency and soft start time, these converters provide many features with a minimum of external ...
Motor Parameters Application Note
Motor Parameters Application Note

... current values. There are many different ways to report these values (for example, peak of sine or RMS of sine) and the results can be very confusing or misleading if the correct formulation is not known. The relationships derived so far use peak of sine (that is, amplitude) values. The equipment ma ...
Secondary-Side Controller with Current Share and Housekeeping ADM1041A
Secondary-Side Controller with Current Share and Housekeeping ADM1041A

... rectifier fails and causes a short. This eliminates the risk of bringing down the load voltage that is supplied by the redundant configuration of other power supplies. In the case of a short, a reverse voltage is generated across the OrFET. This reverse voltage is detected by the ADM1041A and the Or ...
Using the i.MX28 Power Management Unit and Battery Charger
Using the i.MX28 Power Management Unit and Battery Charger

... the VDD5V voltage with an internal bias voltage. The threshold value for a valid 5-V status is configured in the software, and the default value is 4.4 V on the Linux BSP. Additionally, the VBUSVALID method can be configured to generate an interrupt signal when the 5-V supply is removed or inserted. ...
DC fans - specials - ebm
DC fans - specials - ebm

Tender for COEWET-Tech II Rev 201.
Tender for COEWET-Tech II Rev 201.

... Part B of the Bid will be commercial bid that shall comprise the cost details, in format given in Annexure 5. Total cost of the item and accessories required for effective functioning of the equipment / item, including the control system, printer, packaging & forwarding, taxes etc. shall be duly fil ...
ignitions
ignitions

... Do not mount the unit where it will be exposed to water and ensure the two bottom drain slots are unobstructed. If you have an earlier unit without drain slots mount with connector end low. Select a location away from excessive heat and provide a cooling air supply where necessary. If there is a lik ...
HMC336MS8G / 336MS8GE
HMC336MS8G / 336MS8GE

... 100 pF Capacitor, 0402 Pkg. ...
repetitive current controller for grid
repetitive current controller for grid

... When the references Id∗ and Iq∗ are all equal to 0, the generated voltage should be equal to the grid voltage, i.e., the inverter should be synchronised with the grid and the circuit breaker could be closed at any time if needed. In order to achieve this, the grid voltages (uga , ugb and ugc ) are f ...
Zero-current zero-voltage transition inverters with
Zero-current zero-voltage transition inverters with

... in Fig. 5c presents a lower current stress as the turn-on and turn-off process of the main devices take less time. Furthermore, as the load current varies in a sinusoidal way, the auxiliary switch conduction interval and stress are also proportional to a sinusoidal shape. Table 1 presents a comparat ...
< 1 ... 228 229 230 231 232 233 234 235 236 ... 1356 >

Stray voltage



Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report