Competition Electronics, Inc Turbo35
... concerned. In any case, always try to connect the sense leads as close to the actual cell contacts as possible, and try to assure that current through the sense leads does not travel through any more connections than is necessary. ...
... concerned. In any case, always try to connect the sense leads as close to the actual cell contacts as possible, and try to assure that current through the sense leads does not travel through any more connections than is necessary. ...
TPA1517 数据资料 dataSheet 下载
... The TPA1517 is a stereo audio power amplifier that contains two identical amplifiers capable of delivering 6 W per channel of continuous average power into a 4-Ω load at 10% THD+N or 5 W per channel at 1% THD+N. The gain of each channel is fixed at 20 dB. The amplifier features a mute/standby functi ...
... The TPA1517 is a stereo audio power amplifier that contains two identical amplifiers capable of delivering 6 W per channel of continuous average power into a 4-Ω load at 10% THD+N or 5 W per channel at 1% THD+N. The gain of each channel is fixed at 20 dB. The amplifier features a mute/standby functi ...
RF3705 数据资料DataSheet下载
... Digital control input for PA enable and disable (see Operating Modes truth table). Coupler output. This pin must be grounded. Coupler input used for cascading couplers in series. Terminate this pin with a 50 resistor if not connected to another coupler. RF output internally matched to 50 and DC ...
... Digital control input for PA enable and disable (see Operating Modes truth table). Coupler output. This pin must be grounded. Coupler input used for cascading couplers in series. Terminate this pin with a 50 resistor if not connected to another coupler. RF output internally matched to 50 and DC ...
AD8065-6 145MHz, 5-24V RRO.pdf
... Despite the low cost, the amplifiers provide excellent overall performance. The differential gain and phase errors of 0.02% and 0.02°, respectively, along with 0.1 dB flatness out to 7 MHz, make these amplifiers ideal for video applications. Additionally, they offer a high slew rate of 180 V/μs, exc ...
... Despite the low cost, the amplifiers provide excellent overall performance. The differential gain and phase errors of 0.02% and 0.02°, respectively, along with 0.1 dB flatness out to 7 MHz, make these amplifiers ideal for video applications. Additionally, they offer a high slew rate of 180 V/μs, exc ...
Estimating Electric Motor Life Using Motor Circuit Analysis
... Comparative tests: Assumes that phases do not fail at same rate ...
... Comparative tests: Assumes that phases do not fail at same rate ...
SP3220E 数据资料DataSheet下载
... was active at 1000kbps and loaded with an RS-232 receiver in parallel with 250pF capacitors. A solid RS-232 data transmission rate of 250kbps provides compatibility with many designs in personal computer peripherals and LAN applications. ...
... was active at 1000kbps and loaded with an RS-232 receiver in parallel with 250pF capacitors. A solid RS-232 data transmission rate of 250kbps provides compatibility with many designs in personal computer peripherals and LAN applications. ...
AP3107Z Description Pin Assignments
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
BD2200GUL, BD2201GUL
... safety measures including but not limited to fail-safe design against the physical injury, damage to any property, which a failure or malfunction of our Products may cause. The following are examples of safety measures: [a] Installation of protection circuits or other protective devices to improve s ...
... safety measures including but not limited to fail-safe design against the physical injury, damage to any property, which a failure or malfunction of our Products may cause. The following are examples of safety measures: [a] Installation of protection circuits or other protective devices to improve s ...
CMOS - EST
... sufficiently below their source voltage, and because they can pull the drain all the way to Vdd. Thus, if both a p-type and n-type transistor have their gates connected to the same input, the p-type MOSFET will be on when the n-type MOSFET is off, and vice-versa. Example: NAND gate NAND gate in CMOS ...
... sufficiently below their source voltage, and because they can pull the drain all the way to Vdd. Thus, if both a p-type and n-type transistor have their gates connected to the same input, the p-type MOSFET will be on when the n-type MOSFET is off, and vice-versa. Example: NAND gate NAND gate in CMOS ...
Electronically Commutated Motors
... CAUTION: Sheet metal parts, screws, clips and similar items inherently have sharp edges, and it is necessary that the installer and service personnel exercise caution. CAUTION: Surface temperatures of motor may reach temperatures which can cause discomfort or injury to personnel accidentally coming ...
... CAUTION: Sheet metal parts, screws, clips and similar items inherently have sharp edges, and it is necessary that the installer and service personnel exercise caution. CAUTION: Surface temperatures of motor may reach temperatures which can cause discomfort or injury to personnel accidentally coming ...
Scan Tool Test Procedures - Genisys Electronic Diagnostic Scan
... • The purpose of this test is to use bi-directional testing to check the electrical and mechanical condition of a devise. • This test determines which circuit is at fault or if there is a mechanical error. • Use a DVOM along with your scan tool for this test. • The Power feed must be checked first a ...
... • The purpose of this test is to use bi-directional testing to check the electrical and mechanical condition of a devise. • This test determines which circuit is at fault or if there is a mechanical error. • Use a DVOM along with your scan tool for this test. • The Power feed must be checked first a ...
LF412-N 数据资料 dataSheet 下载
... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
A new ZVT PWM DC-DC converter
... converter during most of the time. However, the on and off states of the PWM operation have a minimum time duration because of the operation features of the snubber components [2], [8]. In the conventional ZVT-PWM converter [2], the main switch is perfectly turned on under ZVS and near ZCS by ZVT wi ...
... converter during most of the time. However, the on and off states of the PWM operation have a minimum time duration because of the operation features of the snubber components [2], [8]. In the conventional ZVT-PWM converter [2], the main switch is perfectly turned on under ZVS and near ZCS by ZVT wi ...
NorMax® - Norelco Oy
... Fused load-break switch has holders for medium voltage fuses. Overcurrent blows the fuse and causes the load-break switch to trip. The fused load-break switch is equipped with two earthing switches that ground both sides of the fuse. Changing the fuse is therefore always safe for user. ...
... Fused load-break switch has holders for medium voltage fuses. Overcurrent blows the fuse and causes the load-break switch to trip. The fused load-break switch is equipped with two earthing switches that ground both sides of the fuse. Changing the fuse is therefore always safe for user. ...
Portable Appliance Testing - Health and Safety Directorate
... coordinator or tutor as appropriate. Further guidance can be sought from the Health and Safety Directorate (HSD). Obtain guidance from HSD if electrical equipment is not fitted with standard UK plugs (3 pin, BS 1363). 5. Arrangements Frequency of Portable Appliance Testing Not every electrical ite ...
... coordinator or tutor as appropriate. Further guidance can be sought from the Health and Safety Directorate (HSD). Obtain guidance from HSD if electrical equipment is not fitted with standard UK plugs (3 pin, BS 1363). 5. Arrangements Frequency of Portable Appliance Testing Not every electrical ite ...
XL250-3,5,6 Product Specification
... A no-load condition will not damage the supply or cause a hazardous condition. The power supply will remain stable and operate normally after application of a load. The output voltage regulation may diminish to ±5%. The Power Good logic output will indicate normal operation when the supply is unload ...
... A no-load condition will not damage the supply or cause a hazardous condition. The power supply will remain stable and operate normally after application of a load. The output voltage regulation may diminish to ±5%. The Power Good logic output will indicate normal operation when the supply is unload ...
1. WHAT IS METER
... Korba end SEM is used as master frequency meter. Actual energy is calculated by a software as per configured fictitious meter. Daily Output MWh pertaining to drawal/injection/IR exchange is created. Daily Regional output file for the week period is created. Regional loss is calculated after processi ...
... Korba end SEM is used as master frequency meter. Actual energy is calculated by a software as per configured fictitious meter. Daily Output MWh pertaining to drawal/injection/IR exchange is created. Daily Regional output file for the week period is created. Regional loss is calculated after processi ...
Atmel LED Drivers MSL3163 and MSL3164
... a 1 MHz I2C serial interface. Both interfaces support video frame-by-frame LED string intensity control for up to 16 interconnected devices to allow active area dimming. The devices include an advanced PWM engine that easily synchronizes to a video signal, and per-string phase adjustment to reduce u ...
... a 1 MHz I2C serial interface. Both interfaces support video frame-by-frame LED string intensity control for up to 16 interconnected devices to allow active area dimming. The devices include an advanced PWM engine that easily synchronizes to a video signal, and per-string phase adjustment to reduce u ...
171032401 - Katalog.we
... The connection of the RON resistor to VIN results into an additional compensation of varying VIN values, (VIN feedforward) so the switching frequency will remain almost constant even during VIN transients. A load current transient (low to high current) allows the off-time to immediately transition t ...
... The connection of the RON resistor to VIN results into an additional compensation of varying VIN values, (VIN feedforward) so the switching frequency will remain almost constant even during VIN transients. A load current transient (low to high current) allows the off-time to immediately transition t ...
attention all bidders
... 830 * 716 Richard Arrington Jr Blvd N, Birmingham, Alabama. Bids will be accepted until 5:00 P.M. central time (standard or daylight savings time, as applicable) on August 2, 2007. Bids submitted after this date and time will not be considered. Bids will be publicly opened at 2:00 P.M. on August 3, ...
... 830 * 716 Richard Arrington Jr Blvd N, Birmingham, Alabama. Bids will be accepted until 5:00 P.M. central time (standard or daylight savings time, as applicable) on August 2, 2007. Bids submitted after this date and time will not be considered. Bids will be publicly opened at 2:00 P.M. on August 3, ...
Stray voltage
Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.