• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Brushed DC Motor Fundamentals
Brushed DC Motor Fundamentals

... section allow the controller to pulse width modulate the voltage supplied to a BDC motor. In terms of power consumption, this method of speed control is a far more efficient way to vary the speed of a BDC motor compared to traditional analog control methods. Traditional analog control required the a ...
William States Lee III Nuclear Station FSAR, Chapter 8 CHAPTER 8 ELECTRIC POWER
William States Lee III Nuclear Station FSAR, Chapter 8 CHAPTER 8 ELECTRIC POWER

... The 230 kV switchyard is connected to four transmission lines and the 525 kV switchyard is connected to two transmission lines. No single transmission line to either switchyard is designated as the preferred circuit, but each line has sufficient capacity and capability from the transmission network ...
HIN202, HIN206, HIN207, HIN208, HIN211, HIN213 Datasheet
HIN202, HIN206, HIN207, HIN208, HIN211, HIN213 Datasheet

... generate +10V and -10V. The nominal clock frequency is 125kHz. During phase one of the clock, capacitor C1 is charged to VCC . During phase two, the voltage on C1 is added to VCC , producing a signal across C3 equal to twice VCC . During phase two, C2 is also charged to 2VCC , and then during phase ...
Chapter 3 Special-Purpose Diodes
Chapter 3 Special-Purpose Diodes

ee2257 control system laboratory 0 0 3 2
ee2257 control system laboratory 0 0 3 2

... difference. This result in exciting currents i1 and i2 that are phase displaced by 90o and have equal rms values. These currents give rise to a rotating magnetic field of constant magnitude. The direction of rotation depends on the phase relationship of the two currents (or voltages). The exciting c ...
Electrical Alarm Contact for Thermometers and
Electrical Alarm Contact for Thermometers and

FR3610401047
FR3610401047

... negative half cycles of the sinusoidal ac input voltage (vi), respectively. N channel MOSFETs is utilized to realize the switches S1 and S2. It can be noted that the MOSFETs are subjected to reverse voltage by the ac output of the microgenerator. To block the reverse conduction, the forward voltage ...
SKY65126-21 800-900 MHz High Linearity 2 W Power Amplifier
SKY65126-21 800-900 MHz High Linearity 2 W Power Amplifier

Section 5: System Arrangements
Section 5: System Arrangements

... Composite systems The above system arrangements are the basic building blocks of power distribution system topologies, but are rarely used alone for a given system. To increase system reliability it is usually necessary to combine two or more of these arrangements. For example, one commonly-used ar ...
CA650002EN 600 A 15 kV Class BT-TAP
CA650002EN 600 A 15 kV Class BT-TAP

... submersible and meets the requirements of IEEE Std 386™-2006 standard –– “Separable Insulated Connector Systems”. The 200 A, three-phase rated loadbreak interface provides a means for obtaining a direct conductor test, visible ground and provides a convenient location for an Eaton's Cooper Power ser ...
An efficient method to include equality constraints in branch current
An efficient method to include equality constraints in branch current

... operation and topology. For instance, a priori information exploitable by DSSE includes also the identification of the so-called ‘zero injections’, that is of the nodes that are surely known to have no power consumption or generation. Zero injections are frequent in a distribution grid, in particula ...
10-Bit, 12-Channel Output Decimating LCD Driver AD8386
10-Bit, 12-Channel Output Decimating LCD Driver AD8386

... cause a shift in the parametric performance due to a change in the stresses exerted on the die by the package. Exceeding a junction temperature of 175°C for an extended period can result in device failure. ...
Operating and Service Instructions - AT10.1 Group II
Operating and Service Instructions - AT10.1 Group II

... °C are acceptable. Storage should not exceed two (2) years due to the limited shelf life of the dc filter capacitors when they are not in service. 1.2. REPORTING SHIPPING DAMAGE Upon delivery of the AT10.1 (or related products) if you discover any damage or shortage, make notation on all copies of d ...
Section [26 24 13] [16441]
Section [26 24 13] [16441]

... 98 percent conductivity, equipped with pressure connectors for feeder and branch circuit ground conductors. For busway feeders, extend insulated equipment grounding cable to busway ground connection and support cable at intervals in vertical run. 3. Bus Composition: Plated [copper] [aluminum]. Plati ...
MAX253 Transformer Driver for Isolated RS-485 Interface _______________General Description
MAX253 Transformer Driver for Isolated RS-485 Interface _______________General Description

... or 600mW with a 3.3V supply. Figure 6 shows a typical 5V to isolated 5V application circuit that delivers up to 200mA of isolated 5V power. In Figure 7, the MAX253 is configured to operate from a 3.3V supply, deriving a “boost” VCC for the MAX253 by connecting diodes to both ends of the transformer ...
Date_umn_0130M_15283 - University of Minnesota
Date_umn_0130M_15283 - University of Minnesota

... Last but not the least; I would like to thank my parents for their love and support. Without them none of this would have ever been possible. ...
RSDA-660-75-100 Datasheet
RSDA-660-75-100 Datasheet

Aalborg Universitet
Aalborg Universitet

Pdf
Pdf

Dayton Permanent Magnet DC Voltage Type Gearmolors
Dayton Permanent Magnet DC Voltage Type Gearmolors

... installed to minimize the entry of dirt and moisture. During continual operation, the surface temperature of the gearmotor may become hot. For most gearmotors when operated at rated load and voltage, this condition is usually normal. To verify if condition is normal, check gear­ motor current and vo ...
Sensorless Control for a Switched Reluctance Wind Generator
Sensorless Control for a Switched Reluctance Wind Generator

... The general principle for sensorless control methods relies on the magnetic characteristics of the SRM that vary with the rotor position. The measured variables are typically the phase voltages and the phase currents. The estimated variable is the inductance or the flux linkage. From them, the rotor ...
THE ULTIMATE BATTERY CHARGING STATION
THE ULTIMATE BATTERY CHARGING STATION

STGW25H120DF2
STGW25H120DF2

... 10 µs short-circuit withstand time at TJ = 150 °C ...
MO-201 Electric Power Distribution Systems
MO-201 Electric Power Distribution Systems

select program
select program

< 1 ... 223 224 225 226 227 228 229 230 231 ... 1356 >

Stray voltage



Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report